MRI Phillip W Patton, Ph.D..

Slides:



Advertisements
Similar presentations
Pulse Timing parameters & Weighting
Advertisements

Fund BioImag : Echo formation and spatial encoding 1.What makes the magnetic resonance signal spatially dependent ? 2.How is the position of.
Fund BioImag : Echo formation and spatial encoding 1.What makes the magnetic resonance signal spatially dependent ? 2.How is the position of.
Principles of the MRI Signal Contrast Mechanisms MR Image Formation John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University.
Magnetic Resonance Imaging
Imaging Sequences part I
Richard Wise FMRI Director +44(0)
BE 581 Lecture 3- Intro to MRI.
PHYSICS OF MAGNETIC RESONANCE
Magnetic Resonance Imaging - MRI
MR Sequences and Techniques
MR TRACKING METHODS Dr. Dan Gamliel, Dept. of Medical Physics,
Fysisk institutt - Rikshospitalet 1 Source: Courtesy of Warner Bros Science or black magic? Chap.12 (3) Medical imaging systems: MRI.
The importance of MRI, a few numbers  MRI units worldwide in 2003  75 millions scans per year performed  Constant need for over 1000 MRI technologists.
1 NMR Instrumentation Modern Pulsed Fourier Transform NMR Spectrometer with superconducting magnet Why? Superconducting Magnet Computer Electronics Console.
Chapter 14: Artifacts Mark D. Herbst, MD, PhD. Artifact Something on the image that does not represent something in the patient –Many causes Equipment.
Parameters and Trade-offs
Magnetic Resonance Imaging
Topics spatial encoding - part 2. Slice Selection  z y x 0 imaging plane    z gradient.
Basic Principles MRI related to Neuroimaging Xiaoping Hu Department of Biomedical Engineering Emory University/Georgia Tech
ELEG 479 Lecture #9 Magnetic Resonance (MR) Imaging
Basics of Magnetic Resonance Imaging
Dynamic Effects in NMR. The timescale in nmr is fairly long; processes occurring at frequencies of the order of chemical shift differences will tend to.
Magnetic Resonance Imaging Basic principles of MRI This lecture was taken from “Simply Physics” Click here to link to this site.
Resonance condition. Pulse A coil of wire placed around the X axis will provide a magnetic field along the X axis when a direct current is passed through.
Magnetic Resonance Imaging Mary Holleboom ENGR 302 May 7, 2002.
Tissue Contrast intrinsic factors –relative quantity of protons tissue proton density –relaxation properties of tissues T1 & T2 relaxation secondary factors.
MRI: an Introduction By Mohammad Ali Ahmadi Pajouh Amirkabir University of Technology Biomedical Eng. Dep.
Magnetic Resonance Imaging
Magnetic Resonance Imaging Astounding. The MRI magnet and patient table The operator’s console.
What are we measuring in fMRI? Caroline Catmur Jack Kelly.
Magnetic Resonance Imaging 4
Principles of MRI Physics and Engineering
Principles of Magnetic Resonance
The comparison of MRI imaging In 3.0 T & 1.5T By a.r.shoaie.
Magnetic Resonance Imaging
Prof. Dr. Moustafa. M. Mohamed Dr. Eng. Safa Ahmed El-Askary
Seminar October, 2008 j. brnjas-kraljević. Imaging (MRI)  tomography technique  tomography technique – the volume image is built up by images of thin.
Chapter 4 Mark D. Herbst, M.D., Ph.D.. Magnetization MRI depends on magnetization of tissues Temporary magnetization occurs when the hydrogen nuclei are.
RT 4912 Review (A) Rex T. Christensen MHA RT (R) (MR) (CT) (ARRT) CIIP.
Basic Concept of MRI Chun Yuan. Magnetic Moment Magnetic dipole and magnetic moment Nuclei with an odd number of protons or neutrons have a net magnetic.
Quiz In a 2D spin warp or FT MR scan, aliasing should only occur
Rad T 265 MRI Lecture. No Magnetic Field = No Net Magnetization Protons align with a magnetic field…
Nuclear Magnetic Resonance I Magnetization properties Generation and detection of signals.
1 Introduction to Magnetic Resonance Imaging درس مقدمه ای بر فیزیک پزشکی Sahand University of Technology Faculty of Electrical Engineering M. Shamsi.
MRI Physics Dr Mohamed El Safwany, MD.. MRI Magnetic Resonance Imaging Magnetic Resonance Imaging.
Basic MRI Chapter 1 Lecture. Introduction MRI uses radio waves and a magnetic field to make images MRI uses radio waves and a magnetic field to make images.
MRI Physics: Spatial Encoding Anna Beaumont FRCR Part I Physics.
RT 4912 Review (C) Rex T. Christensen MHA RT (R) (MR) (CT) (ARRT) CIIP.
Spinning Nucleus Produces Magnetic Moment
Magnetic Resonance Learning Objectives
Charged particle. Moving charge = current Associated magnetic field - B.
 This depends on a property of nuclei called spin.  Gyroscope: Principle: As long as its disc remains spinning rapidly the direction of the spin axis.
MAGNETIC RESONANCE IMAGING by PRADEEP V.EPAKAYAL. Mem.no L.
بسم الله الرحمن الرحيم Dr. Maged Ali Hegazy Assistant Professor Alazhar University.
Chap.12 (3) Medical imaging
FMRI data acquisition.
(Instrument part) Thanundon Kongnok M
Sunday Case of the Day Physics
Where Mt is the magnetization at time = t, the time after the 90o pulse, Mmax is the maximum magnetization at full recovery. At a time = one T1, the signal.
Bioengineering 280A Principles of Biomedical Imaging Fall Quarter 2005 MRI Lecture 5 Thomas Liu, BE280A, UCSD, Fall 2005.
MRI Pulse Sequences: IR, EPI, PC, 2D and 3D
MRI ARTEFACTS PG Student : Dr Aditi Shah PG Guide: Dr Rajendra Chavan
Introduction to MR Robert Frost
(4)ELECTRONIC SUPPORT SYSTEM
Superconducting Magnets
The echo time (TE) The echo time (TE) refers to the time between the application of the radiofrequency excitation pulse and the peak of the signal induced.
T2 Relaxation Time T2 relaxation time is defined as the time needed to dephase up to 37% of the original value. T2 relaxation refers to the progressive.
MRI: 造影原理.
Introduction to MR Robert Frost
Presentation transcript:

MRI Phillip W Patton, Ph.D.

RAPHEX General Question 2001 D43: In MRI, the RF frequency is dependent on the: A. Diameter of the body part being imaged. B. Magnetic field strength. C. Pulse Sequence. D. RF coil. E. Relaxation time.

RAPHEX Answer to 2001 Question D43 B. The frequency used in MRI depends on the product of the magnetic field strength and the gyromagnetic ratio of the element being imaged. Since most MRI is of hydrogen atoms, the frequency depends only on the magnetic field strength.

RAPHEX General Question 2001 D46: Gradient fields in MRI are principally used to: A. Maintain a uniform magnetic field in the field of view. B. Eliminate perturbations in the magnetic field due to site location. C. Shorten T1 to reduce scan time. D. Provide spatial localization. E. Measure the spin coupling.

RAPHEX Answer to 2001 Question D46 D. Gradient fields are used to modify the magnetic field so that resonance will be slightly different at different points in the volume of interest. It is then possible to localize these points.

RAPHEX General Question 2002 D51:A higher intensity MRI signal is produced by: A. Long T1, long T2. B. Long T1, short T2. C. Short T1, long T2. D. Short T1, short T2.

RAPHEX Answer to 2002 Question D51 C. The MRI signal strength depends on the value of the magnetization vector along the constant field (z) axis, which is then tipped into the x-y plane to produce the MRI signal. A short T1 implies a rapid return of the magnetization to the z axis following excitation by the RF field. A long T2 implies a long dephasing time for the individual nuclei involved in producing the magnetization. Both these effects will lead to a large value of magnetization and a large MRI signal.

RAPHEX General Question 2003 D53:For hydrogen imaging in a 1.0 T MRI unit, the frequency of the RF signal is about ________ . A. 40 Hz B. 40 kHz C. 40 MHz D. 400 MHz E. 4 GHz

RAPHEX Answer to 2003 Question D53 C. The frequency for hydrogen is 42 MHz x magnetic field strength in tesla.

Raphex 2001 Diagnostic Questions D43. In MRI, the RF frequency is dependent on the: A. Diameter of the body part being imaged B. Magnetic field strength C. Pulse sequence D. Relaxation time E. RF coil

RAPHEX Answer to 2001 Question D43 B. The frequency used in MRI depends on the product of the magnetic field strength and the gyromagnetic ratio of the element being imaged. Since MRI is mainly of hydrogen atoms, the frequency depends only on the magnetic field strength.

Raphex 2001 Diagnostic Questions D46. Gradient fields in MRI are principally used to: A. Eliminate perturbations in the magnetic field due to site location B. Maintain a uniform magnetic field in the field of view C. Measure the spin coupling D. Provide spatial localization E. Shorten T1 to reduce scan time

RAPHEX Answer to 2001 Question D46 D. Gradient fields are used to modify the magnetic field so that resonance will be slightly different at different points in the volume of interest.

Raphex 2000 Diagnostic Questions D48. In MRI images, motion during the scans results in ghost images which appear in the ______ direction. A. Amplitude B. Frequency encoding C. Phase encoding D. Relaxation E. Slice thickness

RAPHEX Answer to 2000 Question D48 B. Motion usually appears as a series of ghost images of reduced intensity displaced in phase encoded direction.

Raphex 2001 Diagnostic Questions D50. Which of the following does NOT generally affect the total exam time of an MRI study? A. # of acquisitions B. # of frequency encoding steps C. # of phase encoding steps D. # of pulse sequences in the study E. TR

RAPHEX Answer to 2001 Question D50 A. frequency encoding steps are determined only by the resolution setting of the ADC.

Raphex 2003 Diagnostic Questions D54. In MRI the signal-to-noise ratio can be increased by all of the following except: A. Switching from a volume to a surface coil B. Increasing the number of acquisitions C. Increasing the static magnetic field strength D. Decreasing the slice thickness E. Increasing TR

RAPHEX Answer to 2003 Question D54

Raphex 2001 Diagnostic Questions D45. Superconducting magnets, compared to resistive magnets: A. Are less expensive B. Are more easily turned off C. Do not require liquid helium D. Have higher field strength

RAPHEX Answer to 2001 Question D45 D. Superconducting magnets have field strengths of 0.3 – 10 T, while resistive magnets have strengths below 0.2 T.

Raphex 2003 Diagnostic Questions D57-D59. Match the following MRI terms. (Answers may be used more than once.) A. Gradient fields B. RF C. Shim coils D. T1 E. T2 D57. Used to adjust magnetic field uniformity D58. Used to localize MR signal D59. Used to tip the net magnetization of spins

Raphex 2003 Diagnostic Answers D57-D59. Match the following MRI terms. (Answers may be used more than once.) A. Gradient fields B. RF C. Shim coils D. T1 E. T2 D57. Used to adjust magnetic field uniformity C D58. Used to localize MR signal A D59. Used to tip the net magnetization of spins B

Raphex 2000 Diagnostic Questions D49. Patients who have MRI scans should be screened to eliminate those who have: A. Internal steel fragments B. Metallic prostheses C. Pacemakers D. Surgical clips E. All of the above

RAPHEX Answer to 2000 Question D49 E. Pacemakers can be affected an cause the pulse rate to change dramatically. Some surgical clips are magnetic and can move causing bleeding. Metallic prostheses can heat due to the RF pulses distorting the images. Steel workers with small fragments in their eyes have lost vision during an MRI scan.

Raphex 2002 Diagnostic Questions D57. All of the following are MRI artifacts except: A. Chemical shift B. Ring C. Susceptibility D. Wrap-around E. Zipper

RAPHEX Answer to 2002 Question D57 B. Bounce point artifact refers to a zero signal that can occur with certain inversion recovery pulse sequences. Chemical shift is a displacement difference between lipids and water. Zipper is a series of “dropouts” due to RF problems. Wrap-around represents aliasing due to the FOV being smaller than the object size.