Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation - 2001.07.23, JBM page 1 T/TE2 Thermostatic Expansion Valves.

Slides:



Advertisements
Similar presentations
Water Source Heat Pump Systems
Advertisements

Service Section Technical Training.
Refrigeration Basics 101 By: Eric Nelson.
Modern Refrigeration and Air Conditioning
Mobile Air Conditioning
Thermostats, Pressure Switches, and Other Electric Control Devices
Liquid Level Control Control Valves Pressure Control Temperature
HEAT PUMPS.
Refrigerators.
Basic Refrigeration Cycle
Tennessee Technology Center Center at Pulaski. Superheat & Sub-cooling A Technician’s Guide to HVACR Diagnostics.
COMMERCIAL REFRIGERATION
Metering Devices North Seattle Community College HVAC Program
Refrigeration Components
HVACR312 - Refrigeration Metering Devices.
EXPANSION VALVE SYSTEM
Section 5: Commercial Refrigeration
Unit 12 Oil Heat Components
Product Introduction.
Evaporators For Air Conditioning
SYSTEM COMPONENTS CHAPTER 5page 91C & 93 L. OBJECTIVES l IDENTIFY AND COMPARE THE STATE OF REFRIGERANT IN EACH SECTION OF A/C SYSTEM. l EXPLAIN PURPOSE.
Heating and Air-Conditioning
Air-Source Heat Pumps I North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed. Airsource Heat Pump 1.
Perfect solution for large building
Air Conditioning Metering Devices.
The Refrigeration Process
High Pressure Motor Valve. High Pressure: 1” & 2” Screwed connection rated to 4000 psi standard. Can be rated up to 6000 psi. Motor: One that imparts.
Flex Cam – Training This shows one version of a complete FlexCam system including Power Unit HCP and Compact Cam CC for piercing operation.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
Large Tonnage Chiller AC Screw. Content Mechanical System Key Components Control Logic Application 2.
Introduction to Energy Management
Floatless Liquid Level Controllers. No float! Large connection opening is not necessary. No worry about inside clearance.
Valves In Industry (Part 1)
TITLE OF THE PROJECT:- AUTOMOBILE AIR CONDITIONING AIM OF THE PROJECT:- TO STUDY ABOUT AIR CONDITIONING SYSTEM OF AN AUTOMOBILE PRESENTED BY: INAMUL.
© 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 5 August 2014.
7 A/C System Components, Operation, and Service.
AIR CONDITIONING (COOLING)
James McIntyre VRF Training Manager V5 Key Components.
Teknologi dan Rekayasa Air Condition System Component.
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
Pressure Regulators KVR + NRD Presentation , Jbm - Page 1.
TXV Devices.
Automotive Heating And Air Conditioning
. Level 3 Air Conditioning Inspections for Buildings
Introduction to Electronic Fuel Systems
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
Top Quality Stop Valves Manufactured by Maniks
High Quality and Cost effective regulating Valve Manufactured by Maniks
High Quality Regulating Valve Launched by Maniks
Refrigeration Basics By: Mohamed Iqbal Pallipurath.
Environmental Thermal Engineering
Valves.
High Performance Regulating Valve Manufactured by Maniks
Regulating Valve for Refrigeration Systems Manufactured by Maniks
Emerson TX7 Series Thermostatic Expansion Valve.
1 Mobile Air Conditioning Basic A/C Operation. 2 System Components All systems contain six major components: Compressor to circulate the refrigerant Condenser.
Refrigeration and Air conditioning
By: JAGDEEP SANGWAN Refrigeration Basics 101.
Refrigeration and Air Conditioning
Refrigeration and Air Conditioning
 R2 Four Basic Components of a Refrigeration System #4 Metering Devices.
Presentation transcript:

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 1 T/TE2 Thermostatic Expansion Valves

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 2 T/TE 2 Thermostatic Expansion Valves The T2 thermostatic expansion valve family is the most universal and adaptable in the world: Wide capacity range Wide temperature range All new and old standard refrigerants With MOP and without MOP

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 3 Danfoss T&TE 2 Thermostatic Expansion Valves for Liquid Injection into Evaporators Type T/TE 2 from 0.2 to 4.5 TR nominal capacity with 8 orifices

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 4 Multi room installation

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 5 T2 system pipe diagram

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 6 T/TE 2 Thermostatic Expansion Valve The T/TE 2 will control and maintain the amount of refrigerant to be injected into the Evaporator. It does this by keeping the Superheat Constant where the sensor is mounted on the suction line (In a constant load scenario)

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 7 T/TE 2 Body Types T 2, Internal Equalizing, two connections Inlet ¼” or 3/8” flare or solder Outlet ½” flare or solder TE 2, External Equalizing, three connections Inlet ¼” or 3/8” flare or solder Outlet ½” flare or solder Equalizing ¼” flare or solder T/TE 2, All Normal Refrigerants

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 8 Ranges: N, -40/+10°C N, -40/+10°C, MOP +15°C NM, -40/-5°C, MOP 0°C NL, -40/-15°C, MOP -10°C B, -60/-25°C B, -60/-25°C, MOP -20°C Standard program: R22 R12 R134a R502 R404A/R507 NOT: R410A Special program: R23 + various R407C REFRIGERANTS & RANGES

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 9 T/TE 2 THERMOSTATIC EXPANSION VALVES

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 10 Type :T2 / TE2 RefrigerantsCFC / HCFC / HFC Media temp. o C ,Range N ,Range NM ,Range NL ,Range B Max. bulb o C100 installed MWP / PB bar34 Max. test pressure37 TECHNICAL DATA

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 11 T/TE 2 Cut-away Model

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 12 Label

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 13 Function of the T/TE 2 The TEV will try to keep a constant superheat at a constant load situation If there is a change in load the TEV will open more at increasing load and open less at decreasing load, and again try to keep a constant superheat The opening degree is decided by a balance between the opening force and the closing forces Pressure in the Power element is the opening force (Sensor temperature) Pressure from the refrigerant is a closing force Pressure from the spring is the other closing force

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 14 Compressor not running. TEV closed. 4.7 bar bulb pressure 0.7 bar spring 4.7 bar 4°C 4.7 bar evaporator pressure Valve in equilibrium 4°C 4.7 bar R22

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 15 Thermostatic expansion valve is now operating at constant superheat bar bulb pressure 0.7 bar spring 3.8 bar - 1,05°C 3.1 bar evaporator pressure Valve constant opening degree -6°C 3.1 bar R

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 16 Thermostatic expansion valve operating at slightly reduced load bar bulb pressure 0.7 bar spring 3.79 bar -1.1°C 3.1 bar evaporator pressure Valve closing little -6°C 3.1 bar R

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 17 Thermostatic expansion valve operating at increased load bar bulb pressure 0.7 bar spring 3.85 bar ° C 3.1 bar evaporator pressure Valve opening -6°C 3.1 bar R

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 18 The compressor is stopped, TEV positively closed. 4.7 bar bulb pressure 0.7 bar spring 4.7 bar 4°C 4.7 bar evaporator pressure Valve closed during standstill 4°C 4.7 bar R

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 19 Superheat Valve Capacity Reserve Capacity Rated Capacity Full Open Capacity SS OS OPS Capacity / superheat relationship

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 20 Adjusting the T/TE 2 In most cases it is not necessary to adjust the T/TE 2 If you have the experience, to improve the system performance by adjusting the valve, please do so

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 21 Adjusting the TEV

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 22 Adjusting the TEV

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 23 Changing the Orifice

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 24 Changing the Orifice, solder version

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 25 Using the T/TE 2 Why ? When ? How ? Where ? Recommendations !

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 26 WHY ? To be able to accurately inject the amount of refrigerant required into the evaporator.

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 27 WHEN ? Every time there is a refrigeration system there should be one TEV for each evaporator (If not another means of throttle device is used)

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 28 HOW ? By mounting the TEV in the refrigeration circuit with any necessary adjustment

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 29 Where ? Always at the inlet of the evaporator

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 30 Adjust if you want to optimize evaporator performance Adjust if the TEV is hunting Recommendations !

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 31 SIZING THE T/TE2 The Catalogue Way The Electronic Way

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 32 The Sales Features Hot Stamped Brass Body Metal to metal push pin/guide Stainless steel bulb Stainless steel capillary Stainless steel capsule and diaphragm Laser welding Laser engraving Double contact bulb Eight interchangeable orifices Stainless steel seat and cone Generous inlet filter Six charge versions (Range/MOP) Automated production (ISO 9002)

Refrigeration and Air Conditioning Expect more from us T-TE 2 Product Presentation , JBM page 33 The Competition Primary : - AlcoTI(E) (T2 Copy) - EgelhofTEW (T2 Copy) - FlicaTMV (T2 Copy) - SporlanQ Secondary : - FAS (T2 Copy) - Parker - Saginomiya - Fuji Koki - Teddington TED (T2 Copy)