Orion Corporation 2.2.20101Pyry Välitalo SSL Presentation A case example: Building a population pharmacokinetic model for theophylline using NONMEM program.

Slides:



Advertisements
Similar presentations
An introduction to population kinetics Didier Concordet NATIONAL VETERINARY SCHOOL Toulouse.
Advertisements

Computational Statistics. Basic ideas  Predict values that are hard to measure irl, by using co-variables (other properties from the same measurement.
The Multiple Regression Model.
Irwin/McGraw-Hill © Andrew F. Siegel, 1997 and l Chapter 12 l Multiple Regression: Predicting One Factor from Several Others.
STA305 week 31 Assessing Model Adequacy A number of assumptions were made about the model, and these need to be verified in order to use the model for.
Pyry Välitalo Nonlinear mixed effects models in pharmacokinetic modeling Lecture notes.
The material in this part of the presentation is prepared using
Background and Objectives Methods and Materials Results Conclusions References Increased computing power gives us the possibility of building more complex.
Some Terms Y =  o +  1 X Regression of Y on X Regress Y on X X called independent variable or predictor variable or covariate or factor Which factors.
Section 4.2 Fitting Curves and Surfaces by Least Squares.
Common Factor Analysis “World View” of PC vs. CF Choosing between PC and CF PAF -- most common kind of CF Communality & Communality Estimation Common Factor.
1 Validation and Verification of Simulation Models.
Pharmacokinetics of Drug Absorption
Inferences About Process Quality
Role and Place of Statistical Data Analysis and very simple applications Simplified diagram of a scientific research When you know the system: Estimation.
Stat 112: Lecture 9 Notes Homework 3: Due next Thursday
1 CHAPTER M4 Cost Behavior © 2007 Pearson Custom Publishing.
Chemometrics Method comparison
Elec471 Embedded Computer Systems Chapter 4, Probability and Statistics By Prof. Tim Johnson, PE Wentworth Institute of Technology Boston, MA Theory and.
Laplace transformation
Statistical Methods For Engineers ChE 477 (UO Lab) Larry Baxter & Stan Harding Brigham Young University.
ANCOVA Lecture 9 Andrew Ainsworth. What is ANCOVA?
Christoffer W Tornoe Oct Population PK Model Building 1 Q & A on Session 1 What is naïve pooled analysis? –Definition –One advantage/disadvantage.
Inference for regression - Simple linear regression
3 CHAPTER Cost Behavior 3-1.
STATISTICS: BASICS Aswath Damodaran 1. 2 The role of statistics Aswath Damodaran 2  When you are given lots of data, and especially when that data is.
Gokaraju Rangaraju College of Pharmacy
INTRAVENOUS INFUSION.
Analysis of Zidovudine pharmacokinetics to determine whether there is a genetic component to the variability and to determine the bioequivalence of seven.
1 1 Slide © 2012 Cengage Learning. All Rights Reserved. May not be scanned, copied or duplicated, or posted to a publicly accessible website, in whole.
Section 8.1 Estimating  When  is Known In this section, we develop techniques for estimating the population mean μ using sample data. We assume that.
Two bootstrapping routines for obtaining uncertainty measurement around the nonparametric distribution obtained in NONMEM VI Paul G. Baverel 1, Radojka.
12a - 1 © 2000 Prentice-Hall, Inc. Statistics Multiple Regression and Model Building Chapter 12 part I.
+ Chapter 12: Inference for Regression Inference for Linear Regression.
MULTIPLE TRIANGLE MODELLING ( or MPTF ) APPLICATIONS MULTIPLE LINES OF BUSINESS- DIVERSIFICATION? MULTIPLE SEGMENTS –MEDICAL VERSUS INDEMNITY –SAME LINE,
1 Chapter 3 Multiple Linear Regression Multiple Regression Models Suppose that the yield in pounds of conversion in a chemical process depends.
Multiple Regression The Basics. Multiple Regression (MR) Predicting one DV from a set of predictors, the DV should be interval/ratio or at least assumed.
The Examination of Residuals. Examination of Residuals The fitting of models to data is done using an iterative approach. The first step is to fit a simple.
University of Warwick, Department of Sociology, 2014/15 SO 201: SSAASS (Surveys and Statistics) (Richard Lampard) Week 7 Logistic Regression I.
Wolverine Pharmacometrics Corporation Between Subject Random Effect Transformations with NONMEM VI Bill Frame 09/11/2009.
Lecture 8 Simple Linear Regression (cont.). Section Objectives: Statistical model for linear regression Data for simple linear regression Estimation.
Statistical Methods II&III: Confidence Intervals ChE 477 (UO Lab) Lecture 5 Larry Baxter, William Hecker, & Ron Terry Brigham Young University.
PHARMACOKINETIC MODELS
This material is approved for public release. Distribution is limited by the Software Engineering Institute to attendees. Sponsored by the U.S. Department.
Introduction to PK/PD Modeling for Statisticians Part 1
Issues in Estimation Data Generating Process:
Population Pharmacokinetic Characteristics of Levosulpiride and Terbinafine in Healthy Male Korean Volunteers Yong-Bok Lee College of Pharmacy and Institute.
1-Compartment Oral Dosing 400 mg of moxifloxacin is administered orally to Mr BB, a 68 yr old male who weighs 75 kg. Blood samples were drawn following.
Chapter 7. Control Charts for Attributes
Slide 1 winBUGS Oct2001 NOVARTISNOVARTIS WinBugs with some PK examples Peter Blood CP-Bios Novartis Horsham Research Centre.
Sampling Design and Analysis MTH 494 Lecture-22 Ossam Chohan Assistant Professor CIIT Abbottabad.
28. Multiple regression The Practice of Statistics in the Life Sciences Second Edition.
June 30, 2008Stat Lecture 16 - Regression1 Inference for relationships between variables Statistics Lecture 16.
Sampling Design and Analysis MTH 494 Lecture-21 Ossam Chohan Assistant Professor CIIT Abbottabad.
1.Andersson, T, et al. Clin Pharmacokinet 2001;40: Hassan-Alin, M, et al. Eur J Clin Pharmacol 2000;56: Population Pharmacokinetic Modelling.
Time Plasma Conc (hr) (mg/L) Below limit of detection 1 Compartment IV Analysis & Renal Elimination 500 mg of tobramycin.
Lecture 7: Bivariate Statistics. 2 Properties of Standard Deviation Variance is just the square of the S.D. If a constant is added to all scores, it has.
Analysis of financial data Anders Lundquist Spring 2010.
5. Evaluation of measuring tools: reliability Psychometrics. 2011/12. Group A (English)
Regression. Why Regression? Everything we’ve done in this class has been regression: When you have categorical IVs and continuous DVs, the ANOVA framework.
Pharmacometrics research group Department of Pharmaceutical Biosciences Uppsala University Approximations of the population Fisher information matrix-
Stats Methods at IC Lecture 3: Regression.
12 Inferential Analysis.
Estimating with PROBE II
Background and Objectives
Statistical Methods For Engineers
ANALYSIS OF POPULATION KINETIC DATA
Short Subject Presentation Unbounded Likelihoods with NM6
12 Inferential Analysis.
Presentation transcript:

Orion Corporation Pyry Välitalo SSL Presentation A case example: Building a population pharmacokinetic model for theophylline using NONMEM program. Pyry Välitalo Orion Pharma

Orion Corporation Population pharmacokinetics: Pharmacokinetics using nonlinear mixed-effects models Rather than model each individuals’ response separately, combine all the data in one model. The differences between individuals are described with random effects. Benefit: Possible to use data that would not be adequate for individual PK modeling (e.g. sparse sampling). Benefit: More data per model yields more power. –One model for each individual versus one model for all data Benefit: Easier to ”locate” sources of between-subject variability? Pyry Välitalo SSL Presentation

Orion Corporation The NONMEM program NONMEM itself is a very general nonlinear mixed-effects regression program, but it comes with packages: –PREDPP is a package of subroutines for most common problems. –NM-TRAN makes NONMEM input and output more user- friendly. Main difference compared to SAS: Designed spesifically to be used in population pharmacokinetics/pharmacodynamics. –Not as general as SAS. –Lots of ”canned solutions” to typical pharmacokinetic problems Pyry Välitalo SSL Presentation

Orion Corporation Some nomenclature Fixed effects: Theta, θ. Mostly used to describe the structural model (e.g. clearance) and covariate relationships (e.g. effect of sex on clearance) –In general statistical nomenclature:  Random effects: Eta, η. The standard deviation of the random effects is ω. In population pharmacokinetics, random effects are most commonly used to describe between-subject variability. –In general statistical nomenclature: b i Residual variability: Epsilon, ε. The standard deviation of the residual variability is σ. –The general statistical nomenclature is similar? Pyry Välitalo SSL Presentation

Orion Corporation Pyry Välitalo SSL Presentation The dataset (theophylline): Part of the data used in: Upton RA, Thiercelin JF, Guentert TW, Wallace SM, Powell JR, Sansom L, Riegelman S. Intraindividual variability in theophylline pharmacokinetics: statistical verification in 39 of 60 healthy young adults. J Pharmacokinet Biopharm Apr;10(2): The dataset comes with NONMEM software.

Orion Corporation The dataset 12 individuals given a single dose of 3-6 mg/kg of oral theophylline. 10 concentration measurements from 25 hours –A total of 120 observations One continuous covariate: Weight Pyry Välitalo SSL Presentation

Orion Corporation ADVAN2 subroutine: The subroutine to be used throughout this example. ADVAN2 subroutine is used throughout the example. This subroutine defines an absorption compartment and a central compartment. ADVAN2 requires the following to be specified: –KA (absorption rate constant) –K (elimination rate constant) –How the observations are scaled (i.e. how do the drug amounts relate to concentrations)? –How the observation and individual prediction relate to each other, i.e. what type of residual error is used? –Everything else is optional Pyry Välitalo SSL Presentation

Orion Corporation Oral pharmacokinetic data and ADVAN2 subroutine In its most basic form: At t=0 A(1)=Dose and A(2)=0 dA(1)/dt=-KA*A(1)KA dA(2)/dt=KA*A(1)-K*A(2) K Define e.g. that –KA=THETA(1) * EXP(ETA(1)) –K=THETA(2) * EXP(ETA(2)) –V=THETA(3) * EXP(ETA(3)) ;Volume of distribution –Y=A(2)/V + EPS(1);observation is the predicted ;concentration plus residual error Pyry Välitalo SSL Presentation Central(2) Depot(1)

Orion Corporation Run1: ”The zero model” This control stream came with the dataset, and likely originates from year 1982: $SUBROUTINES ADVAN2 KA=THETA(1)+ETA(1);absorption rate constant K=THETA(2)+ETA(2);elimination rate constant CL=THETA(3)*WT+ETA(3);clearance is scaled by weight SC=CL/K/WT;scaling of concentration observations is done ;by calculating V=CL/K and scaling by weight ;because dose is weight-adjusted. $THETA (.1,3,5) (.008,.08,.5) (.004,.04,.9);Fixed effects estimates $OMEGA BLOCK(3) ;Random effects variance-covariance $ERROR Y=F+EPS(1);additive error model $SIGMA.4;Residual error variance estimate $EST MAXEVAL=450 PRINT=5;First Order method Pyry Välitalo SSL Presentation

Orion Corporation Run1 results: The parameter estimates make sense. The parameter omega(K) near zero. High relative standard errors on some random effects: –Omega(Ka): 87% –Covariance(Ka-CL): 370% –Covariance(Ka-K): 270% –Omega(K): 51% Pyry Välitalo SSL Presentation

Orion Corporation Run1 results: Plasma concentrations and predictions Pyry Välitalo SSL Presentation

Orion Corporation Final model: Run20 (back-up slides include the steps taken in model-building process) $SUBROUTINES ADVAN2 $PK D1=THETA(6)*EXP(ETA(3)) KA=THETA(1)*EXP(ETA(1)) V=THETA(2)*EXP(ETA(2)*THETA(5)) *WT/70 CL=THETA(3)*EXP(ETA(2)) *WT/70 K=CL/V S2=V $ERROR IPRED=F IRES=DV-IPRED W=THETA(4) ;add error absorption phase W2=THETA(7) ;add error postabs phase IWRES=IRES/W IF(TIME.GT.2) IWRES=IRES/W2 Y=IPRED+W*EPS(1) IF(TIME.GT.2) Y=IPRED+W2*EPS(1) $THETA (.1,2) (0,33) (0,3) (0,1) (0,.5) (0,.3) (0,.3) $OMEGA $SIGMA 1 FIX $EST METHOD=1 INTER MAXEVAL=9999 PRINT=5 $COV Pyry Välitalo SSL Presentation

Orion Corporation Aspects of the improved model: Residual error model $SUBROUTINES ADVAN2 $PK D1=THETA(6)*EXP(ETA(3)) KA=THETA(1)*EXP(ETA(1)) V=THETA(2)*EXP(ETA(2)*THETA(5)) *WT/70 CL=THETA(3)*EXP(ETA(2)) *WT/70 K=CL/V S2=V $ERROR IPRED=F IRES=DV-IPRED W=THETA(4) ;additive error defined with fixed effect. THETA(4) equals sd of res.var. W2=THETA(7) ;additive error defined with fixed effect. THETA(7) equals sd of res.var. IWRES=IRES/W;IWRES are weighted with standard deviation of residual variability IF(TIME.GT.2) IWRES=IRES/W2 ;for post-absorption period Y=IPRED+W*EPS(1) ;multiply by W because sd of residual variability is fixed to 1. IF(TIME.GT.2) Y=IPRED+W2*EPS(1) ;for post-absorption period $THETA (.1,2) (0,33) (0,3) (0,1) (0,.5) (0,.3) (0,.3) $OMEGA $SIGMA 1 FIX;Variance of EPS(1) values is fixed to 1. $EST METHOD=1 INTER MAXEVAL=9999 PRINT=5 $COV Pyry Välitalo SSL Presentation

Orion Corporation Benefits of coding residual error model this way: We can obtain IWRES values as per definition: IWRES = (observation – IPRED)/σ (e.g. Karlsson & Savic 2005) –This is used to standardize the IWRES, so that they should have a standard deviation of 1 (and mean of 0). Sometimes, using a fixed effect makes the model more stable than estimating a lot of random effects. Regarding the use of separate residual errors for absorption and post-absorption phases: This makes sense because the absorption phase typically has more ”noise” than post- absorption phase (and IV data is yet more reliable). –Has been proposed in some articles, e.g. Karlsson MO, Beal SL, Sheiner LB. J Pharmacokinet Biopharm Dec;23(6): Chan PL, Weatherley B, McFadyen L. Br J Clin Pharmacol Apr;65 Suppl 1: Pyry Välitalo SSL Presentation

Orion Corporation Aspects of the improved model: Distribution of random effects, estimation method, implementing weight as a covariate $SUBROUTINES ADVAN2;This is a predefined subroutine for 1-compartment model ;with first order absorption $PK D1=THETA(6)*EXP(ETA(3)) ;log-normal distribution KA=THETA(1)*EXP(ETA(1));log-normal distribution V=THETA(2)*EXP(ETA(2)*THETA(5)) *WT/70;log-normal distribution, linear scaling by weight CL=THETA(3)*EXP(ETA(2)) *WT/70;log-normal distribution, linear scaling by weight K=CL/V S2=V $ERROR IPRED=F IRES=DV-IPRED W=THETA(4) ;add error W2=THETA(7) ;add err postabs IWRES=IRES/W IF(TIME.GT.2) IWRES=IRES/W2 Y=IPRED+W*EPS(1) IF(TIME.GT.2) Y=IPRED+W2*EPS(1) $THETA (.1,2) (0,33) (0,3) (0,1) (0,.5) (0,.3) (0,.3) $OMEGA $SIGMA 1 FIX $EST METHOD=1 INTER MAXEVAL=9999 PRINT=5;method is First Order Conditional Estimation with $COV;Interaction Pyry Välitalo SSL Presentation

Orion Corporation The practical difference between First Order and First Order Conditional Estimation First Order (FO) method expands around ETA=0 –Thus, the parameters are estimated for the mean response and the estimation could be described POPULATION AVERAGE. First Order Conditional Estimation (FOCE) expands around the expected values of each random effect. –Thus, the parameters are estimated for the ”median” subject and the estimation could be described SUBJECT SPESIFIC. (On top of that, FOCE-I takes into account the interaction between random effects and residual error) Pyry Välitalo SSL Presentation

Orion Corporation Implementing bodyweight in the model Linear scaling of both clearance and volume of distribution by bodyweight. Current trend, at least for pediatrics: linear scaling for volume of distribution, nonlinear scaling for clearance (estimate an exponent for nonlinear scaling). –Probably not applicable to obese patients, etc. Weight range in this data 55-86kg (median 70kg). –Probably not wide enough range to estimate nonlinearity Pyry Välitalo SSL Presentation

Orion Corporation Aspects of the improved model: Absorption model $SUBROUTINES ADVAN2 $PK D1=THETA(6)*EXP(ETA(3));D1=duration of a hypothetical infusion into the depot ;compartment KA=THETA(1)*EXP(ETA(1)) V=THETA(2)*EXP(ETA(2)*THETA(5)) *WT/70 CL=THETA(3)*EXP(ETA(2)) *WT/70 K=CL/V S2=V $ERROR IPRED=F IRES=DV-IPRED W=THETA(4) ; add error W2=THETA(7) ;add err postabs IWRES=IRES/W IF(TIME.GT.2) IWRES=IRES/W2 Y=IPRED+W*EPS(1) IF(TIME.GT.2) Y=IPRED+W2*EPS(1) $THETA (.1,2) (0,33) (0,3) (0,1) (0,.5) (0,.3) (0,.3) $OMEGA $SIGMA 1 FIX $EST METHOD=1 INTER MAXEVAL=9999 PRINT=5 $COV Pyry Välitalo SSL Presentation

Orion Corporation The absorption model: Mixed 0- and 1st- order absorption. If (time<D1) dA(1)/dt=Dose/D1 –KA*A(1) If (time>D1) dA(1)/dt=–KA*A(1) A lagtime model was also tried but the mixed 0- and 1st-order absorption proved better with the following benefits: –Describes the data better (lower OFV) –Would make it possible to use proportional error model? –Not as ”radical” a change point as lagtime: possibly more stable than using lagtime? Probably better still: Transit compartmental absorption (was not tried in this case because of time limitations). –Savic RM, Jonker DM, Kerbusch T, Karlsson MO. J Pharmacokinet Pharmacodyn Oct;34(5): Epub 2007 Jul Pyry Välitalo SSL Presentation

Orion Corporation What was the additional effort worth? Compared to the original run we have: –More complicated absorption model. –More complicated residual error model. –(No random effect for elimination rate constant). What did we benefit from this? –A better absorption model may also result in more accurate estimates of V/F and CL/F. –Since different magnitudes of residual error are identified for absorption and post-absorption phases, the model has better simulation properties. –The model overall describes the data better (lower residual error) Pyry Välitalo SSL Presentation

Orion Corporation Original model parameter estimates versus final model parameter estimates: ParameterRun3Run20 OFV111 (6 parameters)1.84 (10 parameters) KA (1/h)1.6 (0.20)2.8 (0.26) V=CL/K (l)32 (0.045)34 (0.038) CL (l/h)2.7 (0.079)2.7 (0.074) Omega(KA)0.65 (0.53)0.90 (0.44) Omega(CL)0.17 (0.30)0.27 (0.56) Sigma (mg/l)0.71 (0.13)0.66 (0.15) / 0.30 (0.11) Pyry Välitalo SSL Presentation *the numbers in parenthesis are relative standard errors

Orion Corporation Take-home messages If you have problems making the model converge: –Realize that non-continuous functions may be hard to integrate (e.g. lagtime for absorption) –Use the appropriate residual error model. –(In NONMEM: start with a simple model and build ”from ground up”) Pyry Välitalo SSL Presentation

Orion Corporation Resources NONMEM. Currently the ”golden standard” in population pharmacokinetic modeling. Requires license. – Xpose: An R package that helps in deciphering the output of NONMEM. Free. – R: A program needed by Xpose to operate. Free. – Census. A helpful program for keeping record of NONMEM runs. Free. – PsN (Perl-speaks-Nonmem). A collection of helpful Perl scripts for NONMEM that make life easier in a lot of ways. Free. MONOLIX. Another population pharmacokinetic program. Free. –Advantages: Shorter runtimes than in NONMEM, provides graphical output by itself. –Disadvantages: Currently not as flexible as NONMEM. May be hard to make sense of the error messages encountered. – Pyry Välitalo SSL Presentation

Orion Corporation (Back-up slides) Run2: ”Modernize” the original run Dataset modifications: Input the exact dose that was given to each patient rather than a weight-scaled dose. Input weight as a covariate for every observation. Rather than model additive random effects, model exponential random effects: THETA(1)+ETA(1) becomes THETA(1)*EXP(ETA(1)) –Because log-normal distributions very typical in pharmacokinetics Pyry Välitalo SSL Presentation

Orion Corporation (Back-up slides) Run2: ”Modernize” the original run Take away covariance matrix for now, but leave all the random effects parameters. –In NONMEM, unnecessary covariance structures can slow down the estimation and add to model instability. Instead of First Order (FO) estimation method, use First Order Conditional Estimation with Interaction (FOCE-I) method: In $ESTIMATION block, ”METHOD=1 INTER” line is added –First Order method would expand around ETA=0 (Fixed effects estimated to describe Population Average) –First Order Conditional Estimation with Interaction expands around η=E(η). Thus, the fixed effects describe a typical subject rather than population average (Subject Spesific approximation) Pyry Välitalo SSL Presentation

Orion Corporation (Back-up slides) Run2 results: OFV Parameter estimate is near its lower boundary: omega(K) Left: individual time-concentration plots Pyry Välitalo SSL Presentation Right: Individual random effects KA versus CL. No linear correlation seems to be present; thus, KA- CL covariance is not implemented.

Orion Corporation (Back-up slides) Forward some runs: Run3: Remove random effect on K –OFV , large standard error found for omega(KA) Run4: Based on run3. Remove random effect on KA –OFV Even though there is difficulty estimating the random effect, it seems to be an important part of the model. Run5: Based on run3. Implement additive+proportional error. –OFV , large standard error found for omega(KA) Run6: Based on run3. Implement proportional residual error. –OFV , fairly large standard error found for omega(KA) SUMMARY of this slide: The random effect of K (the elimination rate) is not essential to the model. The additive+proportional residual error might improve the model a bit. However, more efforts will be spent on the residual error model later on; that’s why additive+proportional residual error is discontinued Author/Department

Orion Corporation (Back-up slides) Run7: Based on run3. Estimate KA, V and CL instead of KA, K and CL: BEFORE (run3): KA=THETA(1)*EXP(ETA(1)) K=THETA(2) CL=THETA(3)*EXP(ETA(2)) V=CL/K AFTER MODIFICATION (run7): KA=THETA(1)*EXP(ETA(1)) V=THETA(2)*EXP(ETA(2)) CL=THETA(3)*EXP(ETA(2)) K=CL/V In run3, it was found that a random effect is not needed for K. Since K=CL/V, in run7 the same random effect is included for both V and CL. Results identical to run3 (OFV ) Author/Department

Orion Corporation (Back-up slides) Runs 8-9: Still testing the random effects: Run8: Take away random effect on V –OFV Standard errors for parameter estimates increase somewhat. Run9: Based on run7. Include a separate random effect for V and implement covariance for CL and V. –dOFV -5.4 –According to the results, the correlation between the two random effects would be absolute, although the magnitude of these random effects differs. -> Something fishy about the dataset? –r= covariance (ETA(CL)-ETA(V) ) (variance(ETA(CL))*variance(ETA(V)) Pyry Välitalo SSL Presentation

Orion Corporation (Back-up slides) The covariance between var(CL) and var(V)? Run10: Reparameterize run9: Use the same random effect for both CL and V but scale with a fixed effect. –OFV Results practically identical to run9. The code in run9: V=THETA(2)*EXP(ETA(3)) ;separate random effect for each CL=THETA(3)*EXP(ETA(2));parameter. $OMEGA BLOCK(2) ;var(CL), covar(CL,V), var(V) And the code in run10: V=THETA(2)*EXP(ETA(2)*THETA(5)) ;scale by theta(5) CL=THETA(3)*EXP(ETA(2)) $OMEGA.2 ;var(CL), used also for V Pyry Välitalo SSL Presentation

Orion Corporation (Back-up slides) Theophylline absorption modeling: Run11: Based on run10: Lagtime on absorption? (+1 parameter) –OFV Improvement on some individual plots. Run12: Based on run11: Lagtime for absorption with random effect? (+1 parameter) –OFV Some difficulties to make this run work. A likely reason for difficulties is that it is hard to integrate at time=lagtime, as absorption starts instantaneously. How to implement lagtime in a model? Write ALAG1=THETA(n) ;this would estimate lagtime for compartment Pyry Välitalo SSL Presentation

Orion Corporation (Back-up slides) Theophylline absorption modeling Run13: Mixed 0- and 1st-order absorption –OFV Run14: Based on run13. Mixed 0- and 1st-order absorption; a random effect is included for 0-order absorption rate. – The standard error of var(KA) becomes lower. This seems the most reasonable solution. How to implement mixed 0- and 1st-order absorption? Add a column ”RATE” into the datafile and set it to -2 for every instance when AMT>0 (else ”.”). Write in the modelfile: D1=THETA(n) ;this would estimate the duration of a hypothetical ;infusion into the absorption compartment Pyry Välitalo SSL Presentation

Orion Corporation (Back-up slides) Absorption phase and residual errors? Oral dosing data is usually considered more ”noisy” than intravenous dosing data. One reason for this is that despite the best absorption modeling efforts, drug absorption from GI tract can be erratic and/or unpredictable. –Thus, more variability can usually be observed in the absorption phase than in post-absorption phase. There are instances* when a time-dependent residual error has been assigned to differentiate between absorption phase and post-absorption phase, e.g. IF(T.LE.2) Y=IPRED+EPS(1) ;absorption phase, additive error IF(T.GT.2) Y=IPRED+EPS(2) ;post-abs phase, additive error *For example: Karlsson MO, Beal SL, Sheiner LB. J Pharmacokinet Biopharm Dec;23(6): Chan PL, Weatherley B, McFadyen L. Br J Clin Pharmacol Apr;65 Suppl 1: Pyry Välitalo SSL Presentation

Orion Corporation (Back-up slides): Runs 15-16: Test using different residual errors for absorption and post-absorption phases Run15: Based on run10. Try setting the absorption-phase residual error to before 2 hours and post-absorption phase residual error to after 2 hours. –Success: OFV , the residual error of post-absorption phase drops to one-half of what it was previously. Run16: Based on run15. Try using proportional residual error for post-absorption phase. –OFV Does not improve the model Pyry Välitalo SSL Presentation

Orion Corporation (Back-up slides): Combine the time-dependent residual error model with absorption model. Implement weight as a covariate. Run17: Based on run14. Combine mixed 0- and 1st-order absorption and time-dependent residual error –OFV Run18: Based on run17. Check if a random effect is still needed in the 0-order absorption rate. –OFV and the standard error of omega(KA) increases. Runs 19-22: Try different ways of scaling the volume of distribution and clearance by weight. –Run20 with linear scaling seems to work best Conclusion: Run20 shall be the final model Pyry Välitalo SSL Presentation