BIOPOTENTIAL AMPLIFIERS

Slides:



Advertisements
Similar presentations
Lecture 2 Operational Amplifiers
Advertisements

1.6 Op-Amp Basics High input impedance Low output impedance Made using difference amplifiers having 2 inputs and at least 1 output 1 Note: Terminals for.
Operational Amplifiers
Operational Amplifiers 1. Copyright  2004 by Oxford University Press, Inc. Microelectronic Circuits - Fifth Edition Sedra/Smith2 Figure 2.1 Circuit symbol.
CHAPTER 3: SPECIAL PURPOSE OP-AMP CIRCUITS
Lecture 4: Signal Conditioning
INTRODUCTION With this chapter, we begin the discussion of the basic op-amp that forms the cornerstone for linear applications; that is, the signal is.
ECG Biopotential Amplifier ASHLEY MULCHRONE ZEXI LIU.
CHAPTER 1: INTRODUCTION TO OPERATIONAL AMPLIFIERS
Ref:080114HKNOperational Amplifier1 Lecture 1 Op-Amp Introduction of Operation Amplifier (Op- Amp) Analysis of ideal Op-Amp applications Comparison of.
Operational Amplifier
Operational Amplifiers
1 ECE 3336 Introduction to Circuits & Electronics MORE on Operational Amplifiers Spring 2015, TUE&TH 5:30-7:00 pm Dr. Wanda Wosik Set #14.
Chapter 13: Operational Amplifiers
Example Problem You are measuring the EEG of a patient and accidently choose two different types of electrodes for EEG lead. One of them has a source impedance.
Lecture II: Linear Applications of Opamp
Introduction to Op Amps
Announcements Assignment 3 due now, or by tomorrow 5pm in my mailbox Assignment 4 posted, due next week –Thursday in class, or Friday 5pm in my mailbox.
Chapter 8 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Introduction to Op Amp Circuits ELEC 121. April 2004ELEC 121 Op Amps2 Basic Op-Amp The op-amp is a differential amplifier with a very high open loop gain.
Analog Electronics Lecture 5.
Analogue Electronics II EMT 212/4
Chapter 8 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Inverting Amplifier. Introduction An inverting amplifier is a type of electrical circuit that reverses the flow of current passing through it. This reversal.
1 ECG Signal Make-up. 2 Biopotential Requirements n High Input Impedance –Minimum loading of the signal being measured –Minimum 10M  n Input circuit.
© 2012 Pearson Education. Upper Saddle River, NJ, All rights reserved. Electronic Devices, 9th edition Thomas L. Floyd Electronic Devices Ninth.
Lecture 1 Op-Amp Introduction of Operation Amplifier (Op- Amp) Analysis of ideal Op-Amp applications Comparison of ideal and non-ideal Op-Amp Non-ideal.
Microelectronic Circuits, Sixth Edition Sedra/Smith Copyright © 2010 by Oxford University Press, Inc. C H A P T E R 02 Operational Amplifiers.
Biopotential Amplifier Speaker: Sun Shih-Yu 3/20, 2006.
ECE 342 – Jose Schutt-Aine 1 ECE 342 Solid-State Devices & Circuits 18. Operational Amplifiers Jose E. Schutt-Aine Electrical & Computer Engineering University.
Module 4 Operational Amplifier
OPERATIONAL AMPLIFIERS. BASIC OP-AMP Symbol and Terminals A standard operational amplifier (op-amp) has; V out is the output voltage, V+ is the non-inverting.
Biomedical Instrumentation I
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
Chapter 30 Operational Amplifiers. 2 Introduction Characteristics –High input impedance –Low output impedance –High open-loop gain –Two inputs –One output.
Operational Amplifiers Op Amps – a useful building block K. El-Ayat 11.
Amplifiers. BASIC AMPLIFIER CONCEPTS Ideally, an amplifier produces an output signal with identical waveshape as the input signal, but with a larger.
Applications of OP-AMP. Introduction Operational amplifier using IC's is inexpensive, versatile and easy to use. For this reason they are used not only.
OP-AMPs Op Amp is short for operational amplifier. An operational amplifier is modeled as a voltage controlled voltage source. An operational amplifier.
OPERATIONAL AMPLIFIERS + - Presented by D.Satishkumar Asst. Professor, Electrical & Electronics Engineering
Differential voltage-gain device that amplifies the difference between the voltages existing at its two input terminal. An instrumentation (or instrumentational)
AUDIO OSCILLATORS An audio oscillator is useful for testing equipment that operates in the audio-frequency range. Such instruments always produce a sine-wave.
Module 2 Operational Amplifier Basics
ARUN MUCHHALA ENGINEERING COLLEGE- DHARI [ ] ANALOG ELECTRONICS Prajapati Omprakash rd ELECTRICAL DEPARTMENT ANALOG ELECTRONICS.
Operational Amplifiers Chapter 10 Boylestad Electronic Devices and Circuit Theory.
Operational Amplifier
BIOPOTENTIAL AMPLIFIERS
BIOELECTRONICS 1 Lec7: CHAPTER 3 Bio-Amplifiers By
Biomedical Instruments Design Biopotential Amplifiers
Operational Amplifiers
Electronic Devices Ninth Edition Floyd Chapter 14.
BIOELECTRONICS 1 Lec 9: Op Amp Applications By
Chapter 10: Operational Amplifiers
Operational Amplifier
Analogue Electronics Circuit II EKT 214/4
Analogue Electronic 2 EMT 212
Medical electronics II
Electronic Circuit-II
Industrial Electronics
Lesson 11: Transducer Electrical Interfaces
Amplifiers: A Bio amplifier is an electrophysiological device, a variation of the instrumentation amplifier, used to gather and increase the signal integrity.
Operational Amplifier (Op-Amp)-μA741
Biomedical Instruments Design Biopotential Amplifiers 1.
Biopotential amplifiers
Passive Components Rayat Shikshan Sanstha’s
Medical electronics II
Fundamentals of Electric Circuits Chapter 5
Passive Components Rayat Shikshan Sanstha’s
Electronic Circuit-II
Chapter 5 Operational Amplifiers
Presentation transcript:

BIOPOTENTIAL AMPLIFIERS By: Engr. Hinesh Kumar Lecturer

Biopotential Amplifier Amplifiers used to process biopotentials are called biopotential amplifier. Biopotential Signals (e.g., ECG, EMG, EEG, EOG, … etc.) The basic function of biopotential amplifier is to increase the amplitude of a weak electric signal of biological origin. Biopotential amplifiers typically process voltages, but in some cases they also process currents. The frequency response of typical bioelectric amplifiers may be from dc (or near dc, i.e., 0.05 Hz) up to 100 kHz.

Cont… Some biopotential amplifiers are ac-coupled, while some are dc-coupled. The dc-coupling is required where input signals are clearly dc or changes very slowly. At frequencies as low as 0.05Hz, the ac-coupling should be used instead of dc-coupling. This is to overcome the electrode offset potential. Also, the skin-electrode interface generates dc offsets. The gain of biopotential amplifiers can be low, medium or high (x10, x100, x1000, x10000).

Low Gain Biopotential Amplifier Gain factors x1 and x10. The unity-gain amplifier is mainly for isolation, buffering and possibly impedance transformation between signal source and readout device. Used for measurement of action potentials and other relatively high-amplitude bioelectric events.

Medium Gain Biopotential Amplifier Gain factors x100 and x1000. Used for recording of ECG waveforms and muscles potentials (EMG), etc.

High Gain Biopotential Amplifier Gain factors over x1000. Used in very sensitive measurement such as recording of brain potentials (EEG).

Typical Biopotential Amplifier Requirements The basic requirements that a biopotential amplifier has to satisfy are: Biopotential amplifiers should have high input impedance i.e., greater than 10 MΩ. Safety: the amplifier should protect the organism being studied. Careful design to prevent macro and micro shocks. Isolation and protection circuitry to limit the current through the electrode to safe level. Output impedance of the amplifier should be low to drive any external load with minimal distortion

Cont… Gain of the amplifier is greater than x1000 as biopotentials are typically less than a millivolt. Most biopotential amplifiers are differential amplifier as signals are recorded using a bipolar electrodes which are symmetrically located. High Common Mode Rejection Ratio (CMMR): biopotentials ride on a large offset signals or noise. Rapid calibration of the amplifier in laboratory conditions. Adjustable Gains: Often the change in scale is automatic Therefore calibration of the equipment is very important

Cont…. The physiological process to be monitored should not be influenced in any way by the amplifier. The measured signal should not be distorted. The amplifier should provide the best possible separation of signal and interferences. The amplifier has to offer protection of the patient from any hazard of electrical shock. The amplifier itself has to be protected against damages that might result from high input voltages as they occur during the application of defibrillators or electrosurgical instrumentation

Operational Amplifier Circuit Model of Operational Amplifier

Operational Amplifiers Dual Power Supply Configuration for Operational Amplifiers

Operational Amplifiers Dual Power Supply Connections for Operational Amplifiers

Operational Amplifiers Typical Signal Voltage Sources for Operational Amplifiers

Operational Amplifiers There are many circuit configurations using op amps as the active device, but only three basic classes of voltage amplifiers exist: Inverting Amplifier Non-inverting Amplifier Unity Gain Non-inverting Amplifier

Inverting Amplifier Inverting amplifier consists of an op-amp, an input resistor (R1), and a feedback resistor (R2). The noninverting input is grounded in this circuit. The point A, the junction of the two resistors and the operational amplifier's inverting input, is properly called the summing junction, or summation node.

Cont… Derivation

Cont… The quantity R2/R1 gives us the magnitude of the voltage gain for this amplifier configuration, and the minus sign tells us that a 180-deeree phase inversion takes place. The voltage amplification or gain expression is represented by the symbol Av The equation is also frequently seen in two alternative but equivalent form.

Example Calculate the gain of an inverting amplifier if the feedback resistor (i,e., R2) is 120 kΩ. and the input resistor (R1) is 5.6 k Ω Solution Av= -R2/R1 Av= -(120 k Ω / 5.6 k Ω) Av= 21

Non-inverting Amplifier In the non-inverting amplifier input voltage is applied directly to the non inverting input terminal of the operational amplifier . Feedback resistor R2, and input resistor R1, are the same as in the inverting follower, except that the other end of R1, is grounded.

Cont… Derivation

Example Calculate the voltage gain of a “non-inverting amplifier if R2, = 10 k Ω and R1, = 2.2 k Ω. Solution At high gains, the gains of the inverting and non-inverting amplifier are very nearly equal but, at low gains, a difference is noted.

Unity Gain Non-inverting Amplifier In the unity Gain non-inverting amplifier the resistor network is not used in this circuit, and the output is connected directly to the inverting input, resulting in 100%. Av= R2/R1+1 Av= 0+1 Av= 1

Multiple Input Circuits More than one input network may be used in an op- amp network, and the output voltage represents the summation of the respective input currents. Three input networks are used in this circuit, and there are three input sources: E1, through E3.

Example Find the output voltage in a circuit, such as one in fig, if R1, = R2, = R3, = 10 k Ω , R4 = 22 k Ω, E1, = 100 mV, E2, = 500 mV, and E3, = 75 mV. Solution:

Differential Amplifier A differential amplifier produces an output voltage that is proportional to the difference between the voltage applied to the two input terminals. The voltage gain for the differential signals is the same as for the inverting followers, provided the ratio equality of R2/R1 = R4/R3 is maintained. Differential amplifiers are useful because it rejects common voltages while amplifying the differential signal of interest.

Instrumentation Amplifier This circuit uses three operational amplifiers, A1, through A3,. The two input amplifiers (i.e., A1, and A2,) are connected in the non-inverting amplifier configuration, while the third amplifier is connected in the simple dc differential amplifier. Simplify circuit analysis by setting the gain of A3, equal to unity (i.e.. R4, = R5, = R6, = R7,). let us assume E1, is applied to the non-inverting input of amplifier A1, and that E2, is applied to the non-inverting input of amplifier A2. Additionally, E3 is the output of A2,, and E4 is the output of A1,. Voltages E1, and E2 are also shown at the inverting inputs of A1 and A2.

Cont…. There are two contributing sources to E3, and E4. In the case of E3: If we set R2=R3

Cont….. The gain of instrumentation Amplifier is