Redox Mechanisms of Rohypnol and Mogadon and Their Exploitation in an Assay Using Dual Electrode ECD Following HPLC K.C. Honeychurch, H. Li, S. Pericleous,

Slides:



Advertisements
Similar presentations
Gas Chromatography & Gas-Liquid Chromatography
Advertisements

Liquid chromatography coupled with Mass spectroscopy
Synthesis and Characterization of Water-Soluble Nanoparticles John R. Renehan, Joseph A. Giesen, April D. Dale, Laura A. Logan, and Deon T. Miles Department.
Screening of a Sulfonamides Library by Supercritical Fluid Chromatography Coupled to Mass Spectrometry (SFC-MS). Preliminary properties-retention study.
Mobile phase is a gas! Stationary phase could be anything but a gas
By Timina Olive Kayaviri Supervisor : Dr. Amugune
ANALYTIC METHODS II. PART Jana Švarcová.  Chromatography  Electrophoresis  Potentiometry  Titration  Spectrophotometry.
Ionic Liquids: A New Class of Sensing Materials Linlin Zhao Bioanalytical Chem, Spring 2007, UConn.
Supercritical Fluid Chromatography and Extraction
Figure 1. Influence of sample solvent on peak shape. The sample is dissolved in buffer with (a) 0%, (b) 30%, (c) 50%, and (d) 70% acetonitrile. Sample.
Development of an Automated, Pyridine Free Method for Aerosol Cyanide Compounds and Hydrogen Cyanide. An Alternative to NIOSH LeRoy Dobson, Chemist.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 15 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
HPLC Systems. Column Chromatography HPLC Modes HPLC – System Components.
Novel Redox Behaviour of the 1,4-Benzodiazepine Lorazepam and Its Analytical Application Kevin C. Honeychurch 1, Ai Teng Chong 2, Khalil Elamin 1 and John.
Melissa Eubanks Chem 4101 December 9,  Silicones are widely used in the personal care and cosmetics industry  Persistence in environment  Decamethylcyclopentasiloxane.
Melissa Eubanks Chem 4101 December 9,  Silicones are widely used in the personal care and cosmetics industry  Studies suggest D 4 potentially.
ELECTROCHEMICAL DETECTION OF BIOFILMS Maria Irene Montenegro Isabel Alexandra Pinho Maria João Vieira.
Chromatographic detectors for Liquid Chromatography.
Lecture 21 HPLC-2 Instrumentation. Column Injector Detector Chromatograph Data Processing.
Investigation of Oxidative and Conjugative Metabolism Reactions with Liquid Chromatography / Accurate Mass High Resolution Mass Spectrometry Maciej Bromirski.
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
Prabh Jassal SUPA Che113 Forensics Ms. Tolentino.
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC). When particles of small diameter (microns) are used as a stationery phase support, the technique is called.
The Redox Behaviour of Diazepam (Valium®) using a Disposable Screen- Printed Sensor and Its Determination in Drinks using a Novel Adsorptive Stripping.
High Performance Liquid Chromatography
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Organic Chemistry I - Lab
Chapter 33 Supercritical-Fluid Chromatography
GC Advantages 1. Very Large N (Very Long Columns) 2. No Packing Material (A=0) 3. Simple Mobile Phase (Compressed Gas) 4. Universal Detectors (FID) 5.
Preliminary Experiments: To obtain a range of redox potentials between -180 and -425 mV, varying concentrations of DTT (between 0.10 and 2.5 mM) were used.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
Aquious Halide Concentration Determination via Leucigenin Quenching and Indirect CE Christopher Hampton, Dr. Eamonn F. Healy, Chemistry Department, St.
NOVEL NON-CONDUCTING FILMSFOR INTERFERENCE-FREE ELECTROCHEMICAL SENSORS M. BADEA a, A. CURULLI b*, G. PALLESCHI a, S. KACIULIS c, A. MEZZI c a Università.
Unique Selling Points (USP) Decade II Antec BV Zoeterwoude, The Netherlands 1.
Created with MindGenius Business 2005® Capillary Electrophoresis Capillary Electrophoresis Advantages Only needs nL sample High speed and resolution, virtually.
Analytical Separations
HPLC – High Performance Liquid Chromatography
Introduction  High-performance liquid chromatography (HPLC) is a form of liquid chromatography.liquid chromatography  The main purpose is to separate.
Chapter 29 Supercritical Fluid Chromatography and Extraction.
Paul Hagey, Eamonn F. Healy, St. Edward’s University,
Stability Indicating Assays for Dose Formulation Stability Testing Teresa Fuller GSK.
Biochemical instrumental analysis - 11 Dr. Maha Al-Sedik 2015 CLS 332.
Supplementary Fig. S2 Elution profiles of amino acid derivatives in a UPLC system. The enzyme (1 μg) was incubated with 10 mM D -amino acid (2.5 mM D -Tyr)
HPLC.
Electrochemical Detection in HPLC 1 ALEXYS™ - HPLC/ECD  Applications  Neuroscience  Pharma  Clinical analysis  Food & Beverages  Environmental.
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Determination of metformin in urine (by Liquid Chromatography LC)
Gaining New insights into Pharmaceutical Stability using High Resolution MS with on-Line Electrochemical Reaction Cell Mark R Taylor 1 *, G. John Langley.
J.Heřt. -synonyms: solid core particles, Fused-core particles -Most recent available particle size is 1.7  m (core 1.25  m, layer 0.23  m)
ELECTROCHEMICAL DETERMINATION OF URANIUM IN SALINE SOLUTIONS Matthew Kirby, 1 Pascal Salaun, 2 Jonathan Watson, 1 and Dominik Weiss. 1 1 Department of.
Gas Chromatography Gas Chromatography Effendy De Lux Putra.
Forensic Toxicology Use Only Analysis of ETG, ETS using the Thermo Scientific Exactive Mass Spectrometer Kent Johnson Fortes lab, Portland Oregon.
University of Koblenz-Landau, Germany
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Rabeay Hassan and Ursula Bilitewski
Protein Film Voltammetry: Cyt P450s
Chem. 133 – 5/11 Lecture.
Synthesis and Characterization of ZnO-CdS Core-Shell Nanohybrids by Thermal Decomposition Method and Studies on Their Charge Transfer Characteristics Rama.
Supercritical Fluid Chromatography and Extraction
What is chromatography?
Chromatography Daheeya Alenazi.
Pharmaceutical Analytical Techniques
Liquid Chromatography - Method Development and Validation
Levofloxacin structural formula
GAS CHROMATOGRAPHY.
Transferring LC-UV to LC-MS.
Electrochemical Synthesis of Metabolites, Degradants, Reference Materials ASMS 2018 San Diego, CA, USA.
Fig. 6. HPLC analysis of RP key components
Presentation transcript:

Redox Mechanisms of Rohypnol and Mogadon and Their Exploitation in an Assay Using Dual Electrode ECD Following HPLC K.C. Honeychurch, H. Li, S. Pericleous, M. Antoniou, A. Abed and J.P. Hart

Talk Outline Importance of the 1,4-benzodiazepine class of drugs Cyclic voltammetric behaviour of Flunitrazepam (Rohypnol), and Nitrazepam (Mogadon) Possible mechanism for their voltammetric behaviour Optimisation of Liquid Chromatographic Separation and dual electrode detection conditions

Importance of the 1,4-benzodiazepine class of drugs Widely used and prescribed drugs for sleeping and anxiety related disorders. Reviews have highlighted the forensic importance of this class of compounds. – DFSA – robberies Concern has also focused on the effects of such compounds in the environment. – Levels in drinking water. – pregnant women and children. – Aquatic environment – chronic effects seen at sub-µg/l. Gas chromatography requires derivatization Immunoassays show cross reactivity. Consequently, need for new rapid sensitive methods

Nitrazepam Flunitrazepam

Cyclic Voltammetric Behaviour

Cyclic voltammograms obtained in the presence (solid line) and absence (dotted line) of 1 mM flunitrazepam in 50 % 0.2 M pH 2 phosphate buffer-50 % acetone. Scan rate 50 mV/s, starting and end potential 0.0 V. (a) initial switching potential +2.0 V, second switching potential ‑ 2.0 V. (b) initial switching potential ‑ 2.0 V, second switching potential +2.0 V. (c) i p versus pH and (d) Ep versus pH. i p α v ½ (a) (b) (c) (d) Honeychurch et al. Anal. Methods, 2012, 4, R1 R2 O1 O2 O1 R2 R1

Honeychurch et al, Anal. Chem. 2006, 78,

High-Performance Liquid Chromatography Coupled with Dual Electrochemical Detection (LC-DED) “Generator” and “Detector” Cells “Generator” cell- analyte is electrochemically converted to a product that can be then more readily electrochemically determined at the “Detector” cell. Advantages - lower working potentials: lower background currents less interferences - oxygen – no degassing, number of common other interferences not seen.

HPLC generator detector chart recorder 3 mm diameter GCE Rheodyne injector Thermostatically controlled Column Faraday cage

minutes 4X10 ‑ 5 AUFS pH 6.6 pH 2.7 pH 2.3 Effect of mobile phase pH on peak separation. 50 % acetone, 50 % 100 mM phosphate buffer, 0.8 mL/min, UV detection λ = 380 nm. C 18 column pKa 1.8 flunitrazepam pKa 3.2 nitrazepam Optimisation of Chromatographic Conditions N F

Hydrodynamic Voltammetry GeneratorDetector

Conclusions We have demonstrated the cyclic voltammetric behaviour of flunitrazepam and nitrazepam. We have the shown the possibility to determine these drugs by LC-DED. Future work will focus on accessing the analytical performance of the LC-DED method.

Acknowledgements We are grateful to the University of the West of England and HEFCE for financial support. Gwen M. Davidson, Emma Brown and Jonathan Toner are thanked for their work with some preliminary studies. Alison Halliday, Paul Bowdler and Mervyn Lewis are thanked for their technical assistance. Kevin C. Honeychurch, Ai Teng Chong, Khalil Elamin and John P. Hart, Novel electrode reactions of diazepam, flunitrazepam and lorazepam and their exploitation in a new redox mode LC-DED assay for serum, Anal. Methods, 2012, 4, Kevin C. Honeychurch, Gemma C. Smith, and John P. Hart, Voltammetric Behavior of Nitrazepam and Its Determination in Serum Using Liquid Chromatography with Redox Mode Dual-Electrode Detection, Anal. Chem. 2006, 78, Thank You References