Use of diagonals and consoles when building 2014-06 Altrad Balliauw – all sites (Look out for site-specific rules!) Floor length Diagonal length Single.

Slides:



Advertisements
Similar presentations
Fixed and mobile scaffolds
Advertisements

Roof Framing A Quick Primer
SHEAR FORCE & BENDING MOMENT
Load Paths and Tributary Area Examples
2.2 STRUCTURAL ELEMENT BEAM
2.2 STRUCTURAL ELEMENT Reinforced Concrete Slabs
CE A434 – Timber Design Structural Behavior.
Evaluate area for vertical shore placement and determine length for header and sole. Header and sole will utilize 12” O.H. for outside vertical posts and.
Drawings and calculations Belgium Scaffolding of higher than 24 metres (highest work floor), unless the manufacturer of the scaffolding equipment used.
WALL FRAMING Section 6 of AS 1684 relates to the regulations governing timber wall construction.
Structural Collapse: Shoring
Medians, Altitudes and Perpendicular Bisectors
A 10-m long steel wire (cross – section 1cm 2. Young's modulus 2 x N/m 2 ) is subjected to a load of N. How much will the wire stretch under.
BFC (Mechanics of Materials) Chapter 2: Shear Force and Bending Moment
Reinforced Concrete Design II
Beams Shear & Moment Diagrams E. Evans 2/9/06. Beams Members that are slender and support loads applied perpendicular to their longitudinal axis. Span,
Trapezoids and Kites Section 8.5.
Copyright 2006 The National Association of Certified Home Inspectors
KS Connected Rate of Change The chain rule can be used to solve problem involving rates of change. Example 1 The length of the side of a square is increasing.
Introduction of Open Web Steel Joist, Deck and Composite Steel Joist
What is good for small mechanisms is very good for very big ones. Above is the major reciprocating parts of a rally engine. At top right is the force applied.
Roofs By Denis Gifford.
BEAM SPIGOTS connected to one DeltaBeam. DOUBLE GUARDRAIL connected to the DeltaBeam.
Distributed loads Loads are not always point loads Sometimes there are uniformly distributed loads on structures.
Ways to Prove that Quadrilaterals are Parallelograms
…what you should have learned…. Investigation #1: Midpoints of Triangle Sides - Length x y ‘x’ is half the length of ‘y’ ‘y’ is twice the length of ‘x’
2182 D - Timber Framing Code Wall Bracing Class Exercise 1.
JLAB CLAS12 Torus Structure The cold mass is composed of 6 coils, each inside a coil case, joined together at the inner radius by a hub and at the outer.
Geometry Section 8.5 Use Properties of Trapezoids and Kites.
A Load Rating of a 3 Span Continuous Deck-to- Through Truss Bridge in Br|R AASHTOWare BrDR 2013 User Group Meeting A Load Rating of a 3 Span Continuous.
MICROSCOPE DESIGN. beam expander and objective Why do we need a beam expander? What facts about the laser do we need to know? How much expansion do we.
Algebra 1 Chapter 3 Section Solving Inequalities With Variables on Both Sides Some inequalities have variable terms on both sides of the inequality.
Lecture 15 - Timber Wall Framing Example
Torsional Resistance of Standard Steel Shapes
A simply supported beam of span 8 m carries two concentrated loads of 32 kN and 48 kN at 3m and 6 m from left support. Calculate the deflection at the.
BASICS OF UK DETAILING. BS Codes : 1) Design code: BS8110 2) Detailing codes: BS8666 BS4449.
BEAMS: Beams are structural members that can carry transverse loads which produce bending moments & shear force. Girders: Main load carrying members into.
Research at Northwestern University: End-bearing Micropiles in Dolomite.
SECTION 11.2 Areas of Parallelograms, Triangles, and Rhombuses.

Calculations D. Smargianaki 29/04/2015 LBNF. Outline D. Smargianaki(CERN) 2 29/04/2015 Comparison between Single Beam & Beam with Spliced connections.
Lattice Multiplication. Step 1 1)Draw a set of 2 by 2 boxes. 46 x 79 2) Cut the boxes in half diagonally. 3) Place the numbers on the outside of the boxes.
The reading is 7.38 mm. The reading is 7.72 mm.
Section 6-5 Trapezoids and Kites. Trapezoid A quadrilateral with exactly one pair of parallel sides.
SECTION 8 - RACKING (BRACING) AND SHEAR FORCES STUDENT HANDOUT
Midsegment Theorem and Coordinate Proofs
Outline Introduction Test section details Axial load test results
BASIC VOCATIONAL STRENGTH Stress Description
Trapezoids and Kites Section 7.5.
Container specifications
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg
- BEAM Sinusoidal Web Beam
Bridges.
CENTROIDS AND CENTRES OF GRAVITY
Closing up of work floor
2.2 STRUCTURAL ELEMENT Reinforced Concrete Slabs
Chapter 6: Normal Distributions
5 × 7 = × 7 = 70 9 × 7 = CONNECTIONS IN 7 × TABLE
5 × 8 = 40 4 × 8 = 32 9 × 8 = CONNECTIONS IN 8 × TABLE
4 × 6 = 24 8 × 6 = 48 7 × 6 = CONNECTIONS IN 6 × TABLE
5 × 6 = 30 2 × 6 = 12 7 × 6 = CONNECTIONS IN 6 × TABLE
Helium collector structural analysis
10 × 8 = 80 5 × 8 = 40 6 × 8 = CONNECTIONS IN 8 × TABLE MULTIPLICATION.
3 × 12 = 36 6 × 12 = 72 7 × 12 = CONNECTIONS IN 12 × TABLE
Revision.
The Bunker Steel Structure – Structural Analysis
Identify Pairs of Lines and Angles
5 × 12 = × 12 = × 12 = CONNECTIONS IN 12 × TABLE MULTIPLICATION.
5 × 9 = 45 6 × 9 = 54 7 × 9 = CONNECTIONS IN 9 × TABLE
3 × 7 = 21 6 × 7 = 42 7 × 7 = CONNECTIONS IN 7 × TABLE
Presentation transcript:

Use of diagonals and consoles when building Altrad Balliauw – all sites (Look out for site-specific rules!) Floor length Diagonal length Single building Number of diagonals for floor load 150 kg/m² Number of diagonals for floor load 200 kg/m² Number of diagonals for floor load 300 kg/m² NP = not possible This also applies if there are several levels lying one above the other, whereby only 1 floor at a time may be loaded with the useful payload and a second level may only have half the payload. Building may not jeopardise the stability of the scaffolding, and may never take place on mobile scaffolding The number of diagonals must always be placed on both sides of the development. Floor0.73 m1.09 m1.57 m2.07 m2.57 m3.07 m Diagonal 0.73 m m m m m m Floor0.73 m1.09 m1.57 m2.07 m2.57 m3.07 m Diagonal 0.73 m m m m m m 1122NP Floor0.73 m1.09 m1.57 m2.07 m2.57 m3.07 m Diagonal 0.73 m m m m m m

Multiple buildings Number of diagonals for floor load 150 kg/m² Number of diagonals for floor load 200 kg/m² Number of diagonals for floor load 300 kg/m² NP = not possible This also applies if there are several levels lying one above the other, whereby only 1 floor at a time may be loaded with the useful payload and a second level may only have half the payload. Building may not jeopardise the stability of the scaffolding, and may never take place on mobile scaffolding The specified number of diagonals must always be placed on 2 sections located next to each other, on the outside the numbers of the single buildings are used. Use of diagonals and consoles when building Altrad Balliauw – all sites (Look out for site-specific rules!) Floor0.73 m1.09 m1.57 m2.07 m2.57 m3.07 m Diagonal 0.73 m m m m m 11222NP 3.07 m 1122NP Floor0.73 m1.09 m1.57 m2.07 m2.57 m3.07 m Diagonal 0.73 m m m m m 1122NP 3.07 m 122NP Floor0.73 m1.09 m1.57 m2.07 m2.57 m3.07 m Diagonal 0.73 m m m m 1122NP 2.57 m 122NP 3.07 m 22NP

Consoles Console 0.39 m Console 0.73 m Load class in accordance with EN Use of diagonals and consoles when building Altrad Balliauw – all sites (Look out for site-specific rules!) Load classEvenly distributed load kN/m2 Pressure load kN (500mmX500mm) Pressure load kN (200mmX200mm) Span L(m)Admissible load q[kN/m]*Load class (EN ) kN/m kN/m kN/m26 Span L(m)Admissible load q[kN/m]*Load class (EN ) kN/m kN/m kN/m24

Consoles Console 1.09 m without extra connection between the struts Console 1.09 m with connection between the struts using a beam Load class in accordance with EN Use of diagonals and consoles when building Altrad Balliauw – all sites (Look out for site-specific rules!) Load classEvenly distributed load kN/m2 Pressure load kN (500mmX500mm) Pressure load kN (200mmX200mm) Span L(m)Admissible load q[kN/m]*Load class (EN ) kN/m kN/m kN/m23 Span L(m)Admissible load q[kN/m]*Load class (EN ) kN/m kN/m kN/m24