SPRINKLER PROTECTION IN ATRIUM SPACES, IS DELUGE AN OPTION?

Slides:



Advertisements
Similar presentations
Fire-fighting & Rescue in Buildings with Engineered Solutions Roy Wilsher Director Community Protection & Chief Fire Officer.
Advertisements

Fire Protection Systems
Basics of Fire Sprinkler Design
Risk Assessment for Cultural Institutions: Fire Testing vs Computer Modeling Frederick W. Mowrer, Ph.D., P.E. Department of Fire Protection Engineering.
Compressed Gas Cylinder Safety
Sprinkler Protection of Non-Storage Occupancies with High Ceiling Clearance 20 May, 2014 Peter Thomas.
Fire Precautionary Arrangements Presented by Mick Leadbetter Fire Safety Adviser.
Buildings and Structures 2 Fixed Installations Aim To provide students with information to allow them to recognise the types of fixed fire protection.
1 Lincolnshire Fire & Rescue Training Centre FIXED INSTALLATIONS DRY AND WET RISERS COMPETENCE STATEMENT 373.
Unit 3 Fire Suppression Section 1 Detection and Alarm Systems.
© Siemens Industry, Inc Confidential / Drive Your Business Forward Ignite the Power of New Products and Partnerships Siemens Fire Partner Summit.
Belfast Dublin Edinburgh London. Evacuation Modelling in Design Jeremy Gardner Jeremy Gardner Associates.
N.F.P.A. 13R Justin Bohlmann FIR-204.
London, 21 May 2014 Alan Brinson A European Residential Sprinkler System Design, Installation and Maintenance Standard.
Why In-Rack Sprinklers?
IBC 2006 Chapter 5 Building Height and Areas After determining occupancies, the code analysis determines what height and areas are allowable for the occupancy.
Automatic Sprinkler System. Importance of Sprinklers First line of protection – small fires Enhanced protection Business protection – less interruption.
AUTOMATIC SPRINKLERS.
3-1 NFIRS 3 Structure Fire Module. 3-2 ObjectivesObjectives The participants will be able to: –describe when the Structure Fire Module is to be used.
Enclosure Fire Dynamics
WATER FOR FIRE PROTECTION (Chapter 26) Basic factors of fire – Rapid oxidation of combustible materials – A combination of oxygen, fuel, and heat is required.
Enclosure Fire Dynamics
Chapter 9. Please read chapter 9.  Please review, know and understand the terms related to fire protection page 284.  Know the Classifications of.
 Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.
Automatic Sprinkler Systems
Computer & Telecom Rooms. 2 Business or building protection ? BUSINESS PROTECTION  Smoke is the problem  Small and Medium Size (
Updates to NFPA 13 What’s New in the 2013 Edition Kenneth E. Isman, P.E., F.S.F.P.E. For the European Fire Sprinkler Network’s Fire Sprinkler International.
NFPA 13: Installation of Sprinkler Systems
Module C Sprinkler systems (4-20)
Research Affecting the Design and Use of Water-Based Fire Suppression Systems Russell P. Fleming, P.E. IFSA Technical Director.
Eurocode 1: Actions on structures – Part 1–2: General actions – Actions on structures exposed to fire Part of the One Stop Shop program Annex E (informative)
Unit 8: Portable Fire Extinguishers & Smoke Control Management Systems
Kidde Engineered Fire Suppression System 25 bar Equipment Hardware Engineered for use with 3M™ Novec™ 1230 Fire Protection Fluid.
Technology in Architecture Lecture 12 Electrical Equipment Electrical Power Management Fire Protection Systems Lecture 12 Electrical Equipment Electrical.
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
Atrium Fire Protection
PREVENTING FROZEN PIPES Efficiently and Thoroughly ©2012 TEMTROL deltaT Inc. - distribute freely unedited.
CLIC CES Webex 12 Nov Summary: – Set of fire safety measures defined in CERN Safety Report – Proposed Structure for CLIC/ILC Fire Safety Report Fabio.
Introduction to the ASD Suppression Actuation Threshold (ASAT) Calculator July _03_ASAT Calculator Sales and Marketing Introduction Presentation.
Prof. Kyriakos Papaioannou ARISTOTLE UNIVERSITY GREECE 7th Intern. Sprinkler Conference-Copenhagen 24-25/6/
Fire Protection Systems Chapter 6. Fire Protection Systems Most of the time you will work with an electrical engineer or fire-protection designer to coordinate.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
ADS / PHX SERIES SYSTEMS DESIGN
Fire safety in wooden constructions Trustful solutions?
1 System Design. 2 Primary Detection Secondary Detection Standards Pipe Design.
Chapter 6 ID 234 Building Codes Fire Suppression.
ME444 ENGINEERING PIPING SYSTEM DESIGN
Fire Detector Placement
Hot /Cold Aisle Containment  Traditional Data Center/Telco designs are changing significantly!
Technology in Architecture Lecture 18 Fire & Life Safety Fire Protection Systems Lecture 18 Fire & Life Safety Fire Protection Systems.
Fundamental Concepts for Design of Special Hazard and Fire Alarm Systems Chapter 1.
PAST STATE  The high intensity of the solar radiation through the roof increases the warming-up in the hall over 30 °C = 86 °F  The high internal temperature.
Hot Work Permit Osan AB Fire Emergency Services.
FM Global Warehouse Fires & Pre-Fire Planning Gary Keith Vice President Engineering Standards Manager.
Fire Blocking Requirements For All Buildings;
Technology in Architecture
Borbotech BV • Tel.: +31(0) • •
Fire Alarm Systems for Emergency Operations of Elevators
Wilson Hall Fire Protection Features
Fire Sprinkler Systems. Types of Fire Sprinkler Systems.
AUTOMATIC SPRINKLERS.
Total Fitness Gym By Student Architect Jhonatan Rubio
NFPA13-Fire Sprinkler System
Graduation Project – 2 Mini-Mall
NFIRS 3 Structure Fire Module
18 Salvage and Overhaul.
Interactive Source: Fire Statistics Great Britain,
Presentation transcript:

SPRINKLER PROTECTION IN ATRIUM SPACES, IS DELUGE AN OPTION? Ing. J.C. (Johan) Hoogeweg DGMR, Netherlands Fire Sprinkler International 2014

Introduction: Objective: To give an insight in the daily practice of a fire engineer regarding High atrium spaces and sprinklers. Fire Sprinkler International 2014

The problem? (1) Architect: Users: Empty atrium / no fire load Larger and higher (>40 m) Users: no limits in usage: Seating area’s (Car) exhibition Service desks Shops Libraries Stages Fire Sprinkler International 2014

The problem? (2) Dutch building code: Fire compartiments (FC) max 1.000 m2, 60 minutes rating between FC’s: Atrium is > 1.000 m2 Atrium is open with the surrounding floors (no walls/glass) Atrium wall is glass (60 minutes rating around 400-600 €/m2) In the past a atrium without fire compartments was acceptable if: Slow growing fire (max 25 m2 after 30 minutes) Smoke and heat venting However this is no longer generally accepted by the fire brigade Option: Sprinkler to control the fire Fire Sprinkler International 2014

Sprinkler code limits Code Max hight remark EN 12845 12 meters Discussion if this is acceptable (will K80 sprinklers control a fire?) FM global 30 meters Wet systems only Limited ceiling slope Lot of fire damage (fire and smoke) due to late activation Test reports are ‘secret’. NFPA 13 15,3 meters Discussion if this is acceptable Fire Sprinkler International 2014

Deluge Concept (1) Concept: 100% based on existing sprinkler technology Apply water over the total area of the protected space Density the same as sprinkler code (depends on hazard) System activated by fire detection system Sidewall sprinklers or sprinklers under the ceiling Fire Sprinkler International 2014

Will it work (example case)? Aspect Real fire test Deluge concept Hazard EN 12845: OH1 Density 5 mm/min Design Area 72 m2 Total atrium (>72 m2) Ceiling height 8 meters 31 meters Activation Sprinkler head Fire detection system First sprinkler / system activated 18:34 [min:sec]* < 5 minutes Fire size Large Smaller than sprinkler Fire controle YES * source: VdS office OH1 fire test Fire Sprinkler International 2014

Activation ASD Activation by fire detection system reliable detection (false detection  water!) Always ‘double knock’ system Smoke detection and flame detection (all directions) Fire size: 0.25 m2 Foam Flame detection Fire Sprinkler International 2014

Safegards It’s a complex systems, accidental activation of the system is possible! To prevent unwanted activation: ‘Double knock’ fire detection Delay in activation of the system (manual override) Sample: Max. delay time [4:00] Detection time flame detection Detection time smoke detection [3:00] Activation time sprinkler (calculated/fire test) [7:00] time Fire Sprinkler International 2014

Sprinkler heads Sprinkler heads: (EC) sidewall sprinklers (EC) pendent/upright sprinklers Listed/approved for risk (VdS/LPC/UL/CE) Glass bulb removed, after pressure test Fire Sprinkler International 2014

Design Area (1) Design area: Location 1: total atrium Location 2: normal design area sprinkler (e.g. EN 12845 OH 72 m2) Location 3: Normal sprinklers + Deluge protection? Fire Sprinkler International 2014

Design Area - Zoned systems Limit water demand en water Damage Fire in zone A: A+B activated Fire in zone B: B+C+D activated Advanced flame detection required (if possible) Not possible in square or round atriums More valves and piping required Fire Sprinkler International 2014

Water management In case of activation, water damage could be a issue: Water in elevator shafts/server rooms/storage  € € € € € € € Keep in mind: Water drains Barriers (2/3 cm is enough) Fire Sprinkler International 2014

Deluge cases Building Police Academy, Apeldoorn Curved ceiling Outside FM 3-26 / FM 2-0 scope Hirsch building, store 8 meter atrium Architect: no sprinklers under glass roof Rijksmuseum, Amsterdam Protection of restaurant seating area Existing roof structure Eneco HQ Rotterdam Atrium height: 25 m Pre FM 3-26 K360 Hilton Schiphol Atrium height: 42m

Case 1: Hilton Amsterdam Airport (1) Fire Sprinkler International 2014

Case 1: Hilton Amsterdam Airport (2) Ceiling height: 42 meters 676 m2 (26*26 meters) ‘no limits’ parking cars exhibitions stages Seating area’s Sprinkler code: NFPA 13 Ordinary hazard group 2 Fire Sprinkler International 2014

Case 1: Hilton Amsterdam Airport (3) Sprinkler design: Sidewall sprinklers only Design area sprinkler: 4,9 * 7,3 m No coverage in the centre of the atrium Fire Sprinkler International 2014

Case 1: Hilton Amsterdam Airport (4) Solution: Sprinkler column

Case 1: Hilton Amsterdam Airport (5) Design area atrium: 3 columns 24 sidewall sprinklers Fire Sprinkler International 2014

Case 1: Hilton Amsterdam Airport (6) Design area -atrium: 24 sidewall sprinklers 291 l/min/sprinkler Water demand: 24 sprinklers * 291 l/min * 60 minutes *1.2 (hydraulic imbalance) = 503 m3 Fire Sprinkler International 2014

Case 2: Eneco World, Rotterdam Position of flame detection Ceiling level: 25-35 m Horeca area Event area Sprinkler heads: Sidewall sprinklers In the koffee corner Position of sprinkler heads Fire Sprinkler International 2014

Conclusion Is deluge THE solution: NO Will deluge control a fire: same a sprinkler (maybe better) Water damage: YES Fire and smoke damage: Small Is deluge A solution: in some cases? Fire Sprinkler International 2014

Questions, discussions? jho@dgmr.nl Fire Sprinkler International 2014