Concept V2.5 Lesson 11 Objectives: After completing this lesson, the learner will be able to: Define the configuration rules associated with the Quantum Controller. Perform the configuration using Concept software. Create an I/O map using the appropriate configuration software. Establish special drop characteristics and I/O module setup Connect to a Quantum controller. Download a configuration and I/O map to a Quantum controller.
Concept V2.5
User Logic Concept V2.5 I/O Mapping to State Ram State-RAM DDI... DDO... AVI... AVO... 3x 4x HW I/O MapRanges 1x 0x 1:1 - 1:32 0:1 - 0:32 3:1 - 3:8 4:1 - 4:4 1:1 0:1 3:1 4:1 Field Devices
Concept V2.5 I/O Map Overview Screen
Concept V2.5
Select the required Module
Concept V2.5 Module Addressing
Concept V2.5 Module Parameters
Concept V2.5 Module Parameters (Analog Input Module) Select required ranges
Concept V2.5 Module Parameters Help Screen
Concept V2.5 Module Parameters (Analog Output Module) Select required output behavior on Timeout
Concept V2.5 Module Parameters (Discrete Output Module) Enter required output behavior on Timeout
Concept V2.5 Connecting to a Quantum PLC
Concept V2.5 Download and Start a Program
Concept V2.5 PLC Simulation Two PLC simulators Used for online testing of the IEC user program (FBD, SFC, LD, IL, and ST) without any hardware. SIM (16 Bit) Simulates a Quantum PLC connected via Modbus Plus. This simulator is available under Windows 3.1, Windows for Workgroups 3.11, Windows 95 and Windows NT. Concept PLCSIM32 (32 Bit) Simulates a PLC connected via TCP/IP, includes simulation of signal states in I/O modules. Up to 5 programming units can be connected to the simulated Quantum at the same time (via a TCP/IP Ethernet connection). This simulator is only available under Windows 95/98 and Windows NT.
Concept V2.5 The 16 Bit Simulator File Location
Concept V2.5 The 32 Bit Simulator File Location
Concept V2.5 The 16 Bit Simulator
Starting the 32 Bit Simulator Simulators
Concept V Bit Simulator Initial Quantum Startup Nothing in Memory
Select CPU Type Concept V2.5 Connect to IEC Simulator(32 Bit) From IEC Simulator: Select required CPU type Download configuration and program
Select CPU Type Left Mouse Button: Select 16 bit input group Left Mouse Button: Select 16 bit output group Left Mouse Button: Select register address Right Mouse Button: Select value range, format CPU Status Left Mouse Button: Change values of Input, Output, Register addresses Concept V2.5 Components of PLCSIM32
Right Mouse Button: Change format Left Mouse Button: Change values Concept V2.5 More Components of PLCSIM32
Concept V2.5 Hidden Slide End of lesson