Reprogram the DAGR and Maps Installation Lesson Title Reprogram the DAGR and Maps Installation Lesson Number Motivator: Reprogramming the DAGR with the latest software keeps DAGR operation fully functional and up-to-date with the latest technology. 113-012 LP 12
LESSON OBJECTIVES Reprogram and install maps into the DAGR receiver. Boot-up Personal Computer Equipment Connections Loading Software Verification Self-test Remove and Reset Hardware Remove Reprogramming Software From PC Inform students of the lesson objectives: Action: Reprogram the DAGR and Maps Installation. Condition: Given a DAGR receiver, DAGR accessories necessary to operate the DAGR, and a DAGR Operator and Maintenance Manual or pocket guide. Standard: Reprogrammed the DAGR and installed a map into the DAGR in accordance with the DAGR Operator and Maintenance Manual. Safety Requirements: An initial introduction to the safety requirements associated with handling lithium batteries and basic warnings and cautions identified in DAGR manuals will be addressed so personnel know proper use, handling and storage requirements for the DAGR. Risk Assessment Level: The Risk Assessment for this lesson is low. Environmental Considerations: None. Instructional Lead-in: Inform the students of the Enabling Learning Objective requirements. LP 12
TOPIC OVERVIEW Introduction Operations Purpose Required Equipment Reprogram DAGR Enabling Learning Objective: ACTION: Reprogram the DAGR CONDITION: Given a DAGR receiver, DAGR accessories necessary to operate the DAGR, and a DAGR Operator Maintenance Manual or pocket guide. STANDARD: Reprogrammed the DAGR in accordance with the DAGR Operator and Maintenance Manual. LP 12
REPROGRAM THE DAGR Reprogramming the DAGR All user and stored data is erased Waypoints Routes Satellite Almanac Data User Setup Information Reprogramming instructions are used to reprogram software residing in the DAGR. All user and satellite data stored in the DAGR is erased during the reprogramming process. This includes any waypoints and routes, satellite almanac data, and user setup information. Be sure to save any critical data prior to reprogramming. Crypto keys are not erased during reprogramming. LP 12
REPROGRAM THE DAGR Ref para 17.2.2 Required Equipment • PC reprogramming software Refer to RDIT website http://www.sed.monmouth.army.mil/RDIT • DAGR software Refer to RDIT website http://www.sed.monmouth.army.mil/RDIT • External AC power cable NSN 6130-01-521-3157 • DAGR to PC data cable NSN 5995-01-521-3198 • IBM compatible personal computer with minimum specifications as follows: Pentium II with 166-MHz processor 5.5-Mb RAM for 1 port, up to 65-Mb for 16 ports, Hard drive with 7-Mb free space Microsoft windows 95, 98, NT, or XP RS-232 serial port (COM1 to COM16) (9-pin version) The following equipment is needed for reprogramming the DAGR: • PC reprogramming software Refer to RDIT website http://www.sed.monmouth.army.mil/RDIT • DAGR software Refer to RDIT website http://www.sed.monmouth.army.mil/RDIT • External AC power cable NSN 6130-01-521-3157 • DAGR to PC data cable NSN 5995-01-521-3198 • IBM compatible personal computer with minimum specifications as follows: Pentium II with 166-MHz processor, 5.5-Mb RAM for 1 port, up to 65-Mb for 16 ports, Hard drive with 7-Mb free space, Microsoft windows 95, 98, NT, or XP (The personal computer should meet or exceed the minimum specifications of the installed version of Microsoft Windows.) RS-232 serial port (with up to 16 Comports) (9-pin version). Additional ports may be added to the personal computer at anytime after the multiple receiver programming software is installed . * On some computers, the only available communication port may be used for a serial mouse. In this case, the mouse must be disabled. LP 12
CHECK ON LEARNING While reprogramming the DAGR what is erased? All user and satellite data stored in the DAGR. What is the minimum free hard drive space? 7 Mb 1. While reprogramming the DAGR what is erased? (Answer: All user and satellite data stored in the DAGR. page 17-1 para 17.2.1) 2. What is the minimum free hard dive space? (Answer: 7-Mb. page 17-1 para 17.2.2.1) LP 12
REPROGRAM THE DAGR Ref para 17.2.3.1 Installing Reprogramming Software Note Disable Screen Saver Perform DAGR Commanded self-test Insert the disk containing the reprogramming software into the drive of the PC (Refer to the Technical Manual for Software Number). b. Copy the Multi_RPG.zip file to C:\, then extract all files directly to C:\. NOTE: Disable the screen saver program active in Windows to guard against possible unexpected errors in reprogramming. For example, open Display Properties either by right clicking on your desktop and then selecting PROPERTIES; or by going through the control panel and when the Display Properties window is displayed, select NONE for the screen saver. Perform a DAGR commanded self-test to ensure the unit is fully operable prior to reprogramming. Any DAGR failing self-test must be returned to Rockwell Collins for warranty repair. Paragraph 17.2.3.1 LP 12
REPROGRAM THE DAGR c. A folder named Multi_RPG was loaded from the zip file into the C: drive. The folder contains two files named SHELLAPP.EXE and RPG.EXE. The only file remaining to interact with is SHELLAPP.EXE. Insert the disk containing DAGR software into the drive of the PC. LP 12
REPROGRAM THE DAGR e. Copy the following files into C:\Multi_RPG: • 31_multi_rpg.cfg • load.abs • yellow_main.abs • red_main.abs f. The reprogramming software is now installed. LP 12
REPROGRAM THE DAGR Ref para 17.2.3.2 Equipment Connections Note If External Power is used Connect one end of the external AC power cable to J4 power connector of the DAGR, and the other end to any 110 VAC outlet. b. Connect the DAGR to PC data cable between J2 data interface connector of the DAGR and the serial port of the PC. NOTE: If external power is being used as primary power for the DAGR, perform steps a and b of this procedure. If internal primary batteries are being used, perform step b only. Paragraph 17.2.3.2 LP 12
REPROGRAM THE DAGR Ref para 17.2.4.1 Reprogramming the DAGR Note Do not remove power Prior to proceeding, ensure reprogramming software is installed in the personal computer procedure and equipment connections have been performed. b. Power the DAGR on. c. Click the START button on the task bar of the monitor, then select RUN. Reprogramming includes loading software and verifying the software part number was correctly loaded. Also, a commanded self-test is recommended after reprogramming and verification is complete. NOTE: Do not remove power to the DAGR while reprogramming is in progress or reprogramming must be started over. Paragraph 17.2.4.1 LP 12
REPROGRAM THE DAGR d. Type C:\Multi_RPG\SHELLAPP at the prompt. Push the Enter key. e. On the SHELLAPP application select browse, then open the desired configuration (.cfg) file from the Multi_RPG folder needed to reprogram the DAGR . LP 12
REPROGRAM THE DAGR f. Select the comport to be used for reprogramming by clicking on the desired comport check box. Up to sixteen comports can be utilized for reprogramming up to sixteen DAGR receivers. All comports can be selected or deselected by clicking on Select All or Clear All, respectively. Refer to your personal computer manual to configure additional ports. LP 12
REPROGRAM THE DAGR g. Select the appropriate comport baud rate (not to exceed 115200) from the drop down list. h. Click on the Start All Selected button at the bottom of the screen. The screen momentarily displays an additional window. LP 12
REPROGRAM THE DAGR i. The status window for the selected comport displays “Power Cycle The Unit”. j. Power cycle the DAGR (power the DAGR off, then on). Reprogramming is started, the DAGR display remains blank, for approximately 20 seconds, and the status window on the personal computer changes color. LP 12
REPROGRAM THE DAGR Note: - Additional yellow status window k. When the status window is yellow, user action is required. Follow instructions of the status window. Note: - Additional yellow status window Note: Additional yellow status window may appear and require repeating this step. LP 12
REPROGRAM THE DAGR l. Wait for the reprogramming process to be completed. This process normally requires three to six minutes. The comport status field is green indicating reprogramming in process for the comport link type displayed . m. When reprogramming is completed, the comport status window is blue in color and displays Finished. n. Power the DAGR off and disconnect all external cables. LP 12
CHECK ON LEARNING What connector do you use on the DAGR to connect it to the PC? J2 What do you type in the RUN Prompt on your PC? C:\Multi_RPG\SHELLAPP 1. What connector do you use on the DAGR to connect it to the PC? (Answer: J2. page 17-1 para 17.3.2) 2. What do you type in the RUN Prompt on your PC? (Answer: C:\Multi_RPG\SHELLAPP. page 17-3 para 17.4.1 c) LP 12
REPROGRAM THE DAGR Ref para 17.2.4.2 Verification Note Power the DAGR on. b. Observe the software part number shown in the start-up display message. Verify the software part number shown matches the software part number that was loaded from the loading software procedure, step a, of this lesson step activity . Note Repeat Power On Procedure This verifies the correct software part number was loaded into the DAGR. NOTE: If needed, repeat the power-on procedure to view the software part number. The software part number can also be accessed from the About page of the DAGR (from the main menu, highlight System, push ENTER, highlight About, push ENTER). Compare software version displayed to software version printed on the reprogramming disk. Paragraph 17.2.4.2 LP 12
REPROGRAM THE DAGR Ref para 17.2.4.3 Commanded Self-test To Ensure DAGR is Ready for Use If Unit Fails Self-test return to Rockwell Collins The commanded self-test is done to ensure the DAGR is ready for use. Any unit that fails the self-test should be returned to Rockwell Collins for repair. Perform the commanded self-test (push and hold POS key, push MENU key, highlight Select Op Mode, push ENTER, highlight TEST, push ENTER). Paragraph 17.2.4.3 LP 12
REPROGRAM THE DAGR Ref para 17.2.5.1 Remove and Reset Hardware Close the MULTI RPG window to shut down the reprogramming software. b. Re-enable screen saver on the PC. c. Re-enable the mouse if it was used for the reprogramming COM port on the PC. d. Disconnect reprogramming cable from PC. If applicable, disconnect power cable used for the DAGR. Paragraph 17.2.5.1 LP 12
REPROGRAM THE DAGR Ref para 17.2.5.2 Remove Reprogramming Software from PC a. Click the START button on the task bar, then select RUN . b. Type EXPLORER at the prompt. c. Go to C:\Multi_RPG, or wherever you stored the program. d. Highlight the C:\Multi_RPG folder by right clicking on it, then click Delete. e. A prompt asks for confirmation prior to deleting, click Yes. Paragraph 17.2.5.2 LP 12
TOPIC SUMMARY Purpose Required Equipment Reprogram DAGR LP 12 During this lesson you have learned to reprogram the DAGR and verify the software was installed correctly. Also, the DAGR must successfully pass a self-test before using in the field. Transition Next Lesson: Now that we know the steps necessary to perform reprogramming of the DAGR, we will learn how to load maps into the DAGR in the next learning step activity. LP 12
TOPIC OVERVIEW Introduction Operations Purpose Required Equipment Installed Maps Enabling Learning Objectives: ACTION: Load a Map into the DAGR. . CONDITION: Given a DAGR receiver, DAGR accessories necessary to operate the DAGR, and a DAGR Operator and Maintenance Manual or pocket guide. STANDARD: Loaded a Map into the DAGR in accordance with the DAGR Operator and Maintenance Manual. LP 12
MAPS INSTALLATION Purpose All user and stored data is erased LP 12 These instructions are used to install maps residing in the DAGR for units covered by this manual. All user and satellite data stored in the DAGR is erased during the maps installation process. This includes any waypoints and routes, satellite almanac data, and user setup information. Be sure to save any critical data prior to maps installation. Crypto keys are not erased during maps installation. LP 12
MAPS INSTALLATION Ref para 17.3.2 Required Equipment • PC Maps installation software PN 984–2517–XXX • Maps Data File Varies with map • External AC power cable NSN 6130-01-521-3157 • DAGR to PC data cable NSN 5995-01-521-3198 • IBM compatible personal computer with minimum specifications as follows: Pentium II with 166-MHz processor 5-Mb RAM Hard drive with 33-Mb free space Microsoft windows 98, NT, 2000, or XP. The personal computer should meet or exceed the minimum specifications of the installed version of Microsoft Windows. RS-232 serial port (COM1 to COM4) (9-pin version) The following equipment is needed for DAGR maps installation: • PC Maps installation software PN 984–2517–XXX • Maps Data File Varies with map • External AC power cable NSN 6130-01-521-3157 • DAGR to PC data cable NSN 5995-01-521-3198 • IBM compatible personal computer with minimum specifications as follows: Pentium II with 166-MHz processor, 5-Mb RAM, Hard drive with 33-Mb free space for map installation software and map data files, Microsoft windows 98, NT, 2000, or XP. (The personal computer should meet or exceed the minimum specifications of the installed version of Microsoft Windows.) RS-232 serial port (COM1 to COM4) (9-pin version). On some computers, the only available communication port may be used for a serial mouse. In this case, the mouse must be disabled. LP 12
CHECK ON LEARNING While installing MAPS what is erased? All user and satellite data stored in the DAGR. What is the minimum free hard dive space? 33 Mb 1. While installing MAPS what is erased? (Answer: All user and satellite data stored in the DAGR. para 17.3.1) 2. What is the minimum free hard dive space? (Answer: 33-Mb. para 17.3.2.1) LP 12
MAPS INSTALLATION Ref para 17.3.3.1 Installing Maps Installation Software Caution Write Access Note Screen Saver Program Insert the disk containing the Maps installation software into the PC CD-ROM drive. b. Right click on the Start task bar, move the mouse pointer over Explore on the list, then left click. . Caution: Ensure you have write access to a personal computer drive (e.g., desktop or drive C) before starting the installation of Maps installation software into the personal computer. If necessary, contact your system administrator to obtain write access. Note: Disable the screen saver program active in Windows to guard against possible unexpected errors during maps installation. To accomplish, open Display Properties either by right clicking on your desktop and then selecting PROPERTIES; or by going through the control panel and when the Display Properties window comes up, select NONE for the screen saver. Paragraph 17.3.3.1 LP 12
MAPS INSTALLATION c. Locate the CD-ROM drive in the Explore window, move the mouse pointer over it, then left click. d. Move the mouse pointer over the MAPSRPG.exe file, then right click . e. Scroll down to the Copy tab, then left click . f. Move the mouse pointer from the window to the desktop, then right click. LP 12
MAPS INSTALLATION g. Move the mouse pointer over Paste, then left click. h. Verify the MAPSRPG.exe file has been copied to your desktop. If it has been copied, remove the Maps installation software CD from the CD-ROM drive. If it has not been copied, repeat steps a through h. d. Move the mouse pointer over the MAPSRPG.exe file, then right click . LP 12
MAPS INSTALLATION Ref para 17.3.3.2 Equipment Connections Note External Power Used Connect one end of the external AC power cable to J4 power connector of the DAGR, and the other end to any 110 VAC outlet. b. Connect the DAGR to PC data cable between J2 data interface connector of the DAGR and the serial port of the PC. NOTE: If external power is being used as primary power for the DAGR, perform steps a and b of this procedure. If internal primary batteries are being used, perform step b only. Paragraph 17.3.3.2 LP 12
MAPS INSTALLATION Ref para 17.3.4.1 Loading Maps Note Do not remove power Ensure DAGR power is off. Ensure the Maps installation software is installed in the personal computer and equipment connections have been performed . Insert the applicable disk containing the DAGR maps data file into the PC CD-ROM drive. Maps installation includes loading maps and also verification the maps were correctly loaded. NOTE: • Do not remove power to the DAGR while maps installation is in progress or maps installation must be started over. • During the following procedure, if the File Not Found prompt appears, select CANCEL to ignore it. Paragraph 17.3.4.1 LP 12
MAPS INSTALLATION Note d. START the Maps installation software by double clicking on MAPSRPG.exe located on the desktop . Note Cancel to ignore e. On the Maps installation screen, double left click inside the Program file text (located next to Program). A window appears to aid the user in finding the file to load. Left click on the drop down menu, then select the CD-ROM drive NOTE: While performing the following step, if a no disk message appears, select Cancel to ignore it. LP 12
MAPS INSTALLATION Note - Red Indicator f. Select the desired ".abs" file on the CD, then left click the Open tab. The file is now inserted into the program file text box (e.g., D:\CedarRapidslg.abs) . g. Power the DAGR on by pushing the PWR key once. On the PC, a red indicator periodically blinks next to “Rx” in the communications box of the MAPSRPG screen. Note - Red Indicator - COM Port NOTE: • The blinking red indicator (blinking approximately every six seconds) indicates the maps installation setup is working. If the red indicator is not blinking, select a different COM port from the COM port drop down menu. • If a working COM port on the PC cannot be found, try using another PC or another DAGR. The MAPSRPG will verify the existence of the DAGR maps files.) LP 12
MAPS INSTALLATION h. Power off the DAGR by pushing and holding the PWR key . i. Select the Setup pull down menu from the Maps installation screen, then left click on Communication Card/No Baud Mult/Divsor. j. From the Setup pull down menu, left click on Bootstrap Baud/19.2K (odd parity). k. From the Setup pull down menu, left click on Transfer Baud/115.2K (odd parity). l. Left click on the GO button of the Maps installation screen. LP 12
MAPS INSTALLATION Note - Display remains blank m. Turn the DAGR on when prompted pushing the PWR key. Note - Display remains blank n. During Maps installation, the labeled process indicators turn red to indicate that the process is active and turn another color (typically blue or green) when the process is complete. o. Maps installation takes approximately 1-30 minutes to complete (depending upon size of the map file). NOTE: After the DAGR is powered on, it is normal for the DAGR display to remain blank during Maps installation. Observe the PC Maps installation screen, not the DAGR during the Maps installation. LP 12
MAPS INSTALLATION p. When Maps installation is complete and prompted by the program. q. When prompted, power off the DAGR by pushing and holding the PWR key. r. To load another map into the DAGR, repeat steps a through q. s. Disconnect the DAGR to PC cable from the DAGR J2 connector. LP 12
CHECK ON LEARNING What connector do you use on the DAGR to connect it to the PC? J2 What do you type in the RUN Prompt on your PC? C:/MAPSRPG/MAPSRPG.EXE 1. What connector do you use on the DAGR to connect it to the PC? (Answer: J2. page 17-9 para 17.3.3.2) 2. What do you type in the RUN Prompt on your PC? (Answer: C:/MAPSRPG/MAPSRPG.EXE. page 17-10 para 17.3.4.1 d) LP 12
MAPS INSTALLATION Ref para 17.3.4.2 Verification Power the DAGR on by pushing the PWR key . b. Clear all popup messages using the ENTER key. c. When the SV Sky View page is displayed, push and release the PAGE or QUIT key until the MAP page is displayed. d. Push the MENU key to display the MAP page menu. e. Use the up or down cursor control keys to highlight Select Map. This procedure is performed on the DAGR to verify the maps were loaded into the DAGR. Paragraph 17.3.4.2 LP 12
MAPS INSTALLATION f. Push the ENTER key to select a map. g. Highlight desired map name to view, then push the ENTER key. h. The selected map is displayed on the DAGR. i. Repeat steps d. through h. to view other individual maps loaded. This procedure is performed on the DAGR to verify the maps were loaded into the DAGR. Paragraph 17.3.4.2 LP 12
MAPS INSTALLATION Ref para 17.3.5.1 Remove and Reset Hardware Remove the disk containing Maps data file from the CD-ROM drive. On the PC, select File/Exit to shut down the Maps installation software . Re-enable screen saver on the PC. d. Re-enable the mouse if it was previously disabled for the Maps installation COM port on the PC. Paragraph 17.3.5.1 LP 12
MAPS INSTALLATION e. Disconnect the DAGR to PC data cable from PC. f. If applicable, disconnect AC power cable used for the DAGR. Paragraph 17.3.5.1 LP 12
MAPS INSTALLATION Ref para 17.3.5.2 Remove Maps Installation Software from PC a. On the PC desktop, place the mouse pointer over MAPSRPG.exe, then right click. . b. Move the mouse pointer over Delete, then left click. c. Confirm file deletion by placing the mouse pointer over Yes, then left click. d. Verify MAPSRPG.exe is removed from the desktop . Paragraph 17.3.5.2 LP 12
MAPS INSTALLATION e. On the PC desktop, place the mouse pointer over RPG.ini, then right click . f. Move the mouse pointer over Delete, then left click. g. Confirm file deletion by placing the mouse pointer over Yes, then left click. h. Verify RPG.ini is removed from the desktop Paragraph 17.3.5.2 LP 12
TOPIC SUMMARY Purpose Required Equipment Installed Maps LP 12 During this topic, you learned how to reprogram and install maps into the DAGR unit. Transition Next Lesson: Now that we know the steps necessary to reprogram and install maps into the DAGR unit, we will conduct a practical exercise. LP 12
Practical Exercise Reprogram the DAGR. Load a Map into the DAGR. LP 12
LESSON SUMMARY You have now learned how to reprogram and install maps into the DAGR receiver. Boot-up Personal Computer Equipment Connections Loading Software Verification Self-test Remove and Reset Hardware Remove Reprogramming Software From PC Inform students of the lesson objectives: Action: Reprogram the DAGR and Maps Installation. Condition: Given a DAGR receiver, DAGR accessories necessary to operate the DAGR, and a DAGR Operator and Maintenance Manual or pocket guide. Standard: Reprogrammed the DAGR and installed a map into the DAGR in accordance with the DAGR Operator and Maintenance Manual. During this lesson you have learned to install software and maps into the DAGR, and verify the software and maps were installed correctly. Transition Next Lesson: Now that we know the steps necessary to perform Maps Installation, we will learn how to clear the DAGR. LP 12