0.1 pg/mL: Mean = 3.87 SD = 0.249 %CV = 6.4% Mean LoD = 17 fg/mL Curve 1, LoD = 0.012 pg/mL Curve 2, LoD = 0.018 pg/mL Curve 3, LoD = 0.026 pg/mL.

Slides:



Advertisements
Similar presentations
Research Techniques Made Simple: Enzyme Immunoassay and ELISA
Advertisements

Convenient biomarker assessment of mild to severe sports-related traumatic brain injury represents a desirable goal as an adjunct for assessing severity.
AACB NSW/ACT QC Subcommittee TnT hs Survey Results Methods Results Introduction Persephone Giannopoulos¹ and representatives of the AACB NSW/ACT QC Subcommittee.
Development of Assays for Use in Patient Response Measurement in Phase 0 Trials Robert Kinders Ralph Parchment Pharmacodynamic Assay Development and Implementation.
ELISA Enzyme Linked Immunosorbent Assay. Definitions  Antibodies (also known as immunoglobulins abbreviated Ig) are gamma globulin proteins that are.
1 Lecture: Forensic Serology - Immunoassays Antibody/Antigen reaction provides the means of generating a measurable result. “Immuno” refers to an immune.
Immune Testing.
L MACKAY, N CRINIS, Q LAM, R SCOTT
Summary 1 l The Analytical Problem l Data Handling.
Introduction to Immunoassays
Quality Assurance.
Enzyme-linked Immunosorbent Assay
Antigens & Antibodies: reactions, detection, and applications.
Method Comparison A method comparison is done when: A lab is considering performing an assay they have not performed previously or Performing an assay.
The effect of TCDD on cytokine production during the progression of insulitis in NOD mice Tuan Pham Dr. Nancy Kerkvliet Environmental and Molecular Toxicology.
Quality Assurance.
Validation: concept, & considerations
Simoa Accelerator Laboratory
Performance Characteristics of the FARRZYME™ High Avidity Anti-dsDNA IgG Antibody ELISA Brenda B. Suh-Lailam 1, Tyson R. Chiaro 1, K. Wayne Davis 1, Andrew.
Principles of ELISA. Immunoassay Immunochemical reactions form the basis of a diverse range of sensitive and specific clinical assays. In a typical immunochemical.
Analytical Goals. Valid data are essential in making medical decisions, the most important concepts used in judging analytical performance :- 1)Analytical.
Analytical considerations
ELISA (aka Enzyme-Linked Immunosorbent Assay) Professor C. Roth 125:315: BME Measurements and Analysis Laboratory Spring 2003.
Enzyme Linked Immunosorbent Assay (ELISA). ELISA Enzyme Linked Immunosorbent Assay (ELISA) Term Was Coined By Engvall and Pearlmann in 1971 Different.
How Does ELISA Work? By: Ian Lin, Marko Cavar, Justin Chiu & Lily Hou Sep 15, PHM142 Fall.
Enzyme-Linked Immunosorbent Assay [ELISA] BCH 462[practical] Lab#5.
Quality Control Lecture 5
© Copyright 2009 by the American Association for Clinical Chemistry Quantification of Galactose-1-Phosphate Uridyltransferase Enzyme Activity by Liquid.
BNPCV APCCB BIOLOGICAL VARIATION FOR N-TERMINAL PRO-BNP Jones GRD 1, Bennett A 2,3, Boscato L 1, Macdonald P 2, Brien J 3. Departments of Chemical.
1 Immunoassay Testing Forensic Toxicology. 2 Introduction Antibody/Antigen reaction provides the means of generating a measurable result. “Immuno” refers.
Quality Assurance How do you know your results are correct? How confident are you?
5. Quality Assurance and Calibration Quality assurance is We do to get the right answer for our purpose. Have Sufficient accuracy and precision to support.
BioChip Ventures Division a 3-Dimensional Microarray Substrate.
Evaluation of the Presage™ ST2 ELISA Jun Lu 1, David G. Grenache 1,2 1 ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT 2 Department.
© Copyright 2009 by the American Association for Clinical Chemistry γ′ Fibrinogen: Evaluation of a New Assay for Study of Associations with Cardiovascular.
Author: Cheng-Chi Wang, Chi-Huey Wong
Reading Report: A unified approach for assessing agreement for continuous and categorical data Yingdong Feng.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Limit of detection, limit of quantification and limit of blank Elvar Theodorsson.
Magnetically Promoted Rapid Immunoreactions Using Functionalized Fluorescent Magnetic Beads Satoshi Sakamoto and Co Department of Biological Information.
Industrial Technology Institute Test Method Validation & Verification H.P.P.S.Somasiri Principal Research Scientist / SDD-QAD /QM Industrial Technology.
Chapter 1: Introduction Analytical Chemistry Analytical Chemistry Qualitative analysis Qualitative analysis Quantitative analysis Quantitative analysis.
Quality Control Internal QC External QC. -Monitors a test's method precision and analytical bias. -Preparation of quality control samples and their interpretation.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
ELISA Enzyme-linked Immunosorbant Assay Detects the presence of minutes quantities of either an antibody or an antigen Important diagnostic tool in many.
 Remember Chemistry panel Quality Control:-  In a medical laboratory, it is a statistical process used to monitor and evaluate the analytical process.
Dengue fever caused by dengue virus (DENV), a member of Flaviviridae leads to large global disease burden. Detection of immunoglobulin M (IgM) and nucleic.
BioPlex 2200 HIV Ag-Ab Assay
Enzyme Linked Immunosorbent Assay
Protein quantitation I: Overview (Week 5). Fractionation Digestion LC-MS Lysis MS Sample i Protein j Peptide k Proteomic Bioinformatics – Quantitation.
Diagnostic clinical chemistry
The Detection of expressed IL-32 in the Human Stomach Cancer using an ELISA and Immunostaining. Seo, Eun-Hee October 6, 2008 Lab of Cell Biol& ImmunoBiochem.
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
A Sandwich DNA Model for Rapid and Sensitive Detection of NSCLC Utilizing the Magnetic Modulation Biosensing System Saar Ashri The Open University Optical.
Estimated Glomerular Filtration Rate and Albuminuria Are Associated with Biomarkers of Cardiac Injury in a Population-Based Cohort Study: The Maastricht.
Enzyme Linked Immunosorbent Assay (ELISA)
Immunoassays are tests that take advantage of the specificity of antibodies to their protein epitotes. Qualitative example: pregnancy test kits, HIV.
Absorbance: Enzyme Linked Immunosorbent Assays (ELISA)
Application of Design of Experiments using JMP to Develop a Universal
Abstract Methods Objectives Conclusions Results
Enzyme Linked Immunosorbent Assay
Enzyme-Linked Immunosorbent Assay [ELISA]
Practical clinical chemistry
Choice of Methods and Instruments
Introduction To Medical Technology
Satish Pradhan Dnyanasadhana College, Thane. Department of Chemistry S
Raised serum cardiac troponin I concentrations predict hospital mortality in intensive care unit patients†  T. Reynolds, M. Cecconi, P. Collinson, A.
▪Internal quality control:
Enzyme Linked  Immuno sorbent  Assay  
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Presentation transcript:

0.1 pg/mL: Mean = 3.87 SD = %CV = 6.4% Mean LoD = 17 fg/mL Curve 1, LoD = pg/mL Curve 2, LoD = pg/mL Curve 3, LoD = pg/mL Curve 4, LoD = pg/mL Prototype digital immunoassay for troponin I with subfemtomolar sensitivity L. Chang 1, P. Patel 1, L. Song 1, Y. Chen 1, D. Hanlon 1, K. Minnehan 1, M. Gardel 1, B. Pink 1, L. York 1, S. Sullivan 1, R. Meyer 1, B. Flaherty 1, J. Christopher 1, D. H. Wilson 1, M. J. Conrad 2, P. Jarolim 2 1 Quanterix Corporation, Lexington, MA 2 Brigham and Women’s Hospital, Harvard Medical School, Boston, MA INTRODUCTION RESULTS CONCLUSIONS METHODOLOGY High-sensitivity cardiac troponin I (cTnI) measurement offers a promising new tool for early detection and monitoring of cardiovascular disease. The ability to reliably assign TnI values to all normal subjects tested represents a newly desired assay capability in many applications. We report preliminary analytical data from a prototype Single Molecule Array (Simoa, or digital immunoassay) for serum TnI that is capable of 2─3 logs greater sensitivity than the clinically used cTn assays and 1─2 logs greater sensitivity than the latest high-sensitivity troponin assays, most of which are not yet commercially available. The Simoa assay used reagents similar to those for conventional ELISAs. Tnl-specific capture antibody was immobilized on paramagnetic beads, and de- tection antibody was biotinylated. Sandwich immuno- complexes were formed by incubating TnI antigen and antibodies together and then labeling with streptavidin-conjugated beta-galactosidase. Beads with the labeled immunocomplexes were isolated and sealed in individual microwells of the array containing fluorescent substrate. Well arrays were imaged with a CCD camera. Enzyme-labeled beads that converted substrate into fluorescent product over time were considered to be “on” for purposes of digital counting. The entire range of signal was determined using imaging analysis software to determine the Average Enzyme per Bead (AEB), the unit of measurement of Simoa. A standard curve relating the AEB output to TnI concentration was used to determine the sample concentration. The digital Tnl immunoassay was evaluated for recovery, linearity, precision, analytical sensitivity, and ability to measure cTnI in normal serum samples. Discrimination of normal subjects from those with mild to moderate heart failure was also preliminarily assessed. Fig. 2. Analytical LoD estimate for TnI assay. A mean LoD of 17 fg/mL (SD, 6.9) was estimated from 4 calibration runs performed on different days with 2 reagent lots. The mean signal-to-background ratio at the lowest dose is 3.87 (SD, 0.24), indicating excellent curve shape at the low end. Fig. 1. Dose-response of Simoa over 3 logs of spiked TnI in human serum. Each data point represents the mean of 3 replicates. The insert highlights the low end of the curve obtained with digital quantification. The line shows linear fitting with an R 2 > 0.999, from which the 3SD estimated LoD was 17.8 fg/mL. AEB TnI (pg/mL) Fig. 3. Linearity by mixing high and low TnI samples. Admixtures were prepared per CLSI EP6-A using a high TnI sample (76.9 pg/mL) and a low TnI sample (2.58pg/mL). Data fit a linear model (R2 = 0.989), with an average deviation from linearity of 11%. Fig. 4. Test of TnI in normal control and heart failure samples. Serum samples from 46 control individuals and 34 mild/moderate heart failure patients (New York Heart Association classes II and III) were tested. cTnI values from the 46 normal control samples ranged from 0.13 to pg/mL, with a mean, median, and 75 percentile of 1.92, 1.05, and 2.36 pg/mL, respectively. Total imprecision from a normal serum sample tested on 4 separate runs was 9.5% CV with a mean cTnI of 1.45 pg/mL. cTnI values from 34 mild to moderate heart failure patients ranged from 2.27 to 388 pg/mL, with a median of pg/mL. Findings for the cohort of heart failure samples were significantly elevated relative to those of the normals (p =0.0067). Table 1. Analysis of control and heart failure patients The assay reliably quantified cTnI in normal individuals, with an LoD well below the lowest normal sample tested. These data suggest the assay could represent an advance in sensitivity relative to current high-sensitivity cTnI methods and could be a new enabling tool for high definition cTnI measurement. Rissin DM, et al. (2010) Single-molecule enzyme- linked immunosorbent assay detects serum proteins at subfemtomolar concentrations. Nature Biotech 28: Rissin DM, et al. (2011) Simultaneous detection of single molecules and singulated ensembles of molecules enables immunoassays with broad dynamic range. Anal Chem 83: Chang L, et al. (2012) Single molecule enzyme-linked immunosorbent assays: Theoretical considerations. J Immun Meth. 378: P Corresponding author: Dr. Lei Chang Quanterix Corporation 113 Hartwell Avenue, Lexington, MA 02421, USA Tel: REFERENCES TnI value ng/LCtrlHF Number of values4634 Minimum % Percentile Median % Percentile Maximum Mean Std. deviation Std. error Lower 95% CI Upper 95% CI P value Expected troponin (pg/mL) Observed troponin (pg/mL) Y = M0 + M1*x +... M8*x 8 + M9*x 9 M0─ M M2─ M e-5 R2R Y = M0 + M1*X M0─ M R2R TnI (pg/mL) ControlHF TnI (pg/mL) 3SD LoD = 17.8 fg/mL Signal : background