Screening of a Sulfonamides Library by Supercritical Fluid Chromatography Coupled to Mass Spectrometry (SFC-MS). Preliminary properties-retention study.

Slides:



Advertisements
Similar presentations
Introduction to Chromatography
Advertisements

Gas Chromatography Vaporization of sample Gas-solid
Gas Chromatography There an be many parts to a gas chromatography system but the basic components include: An injection system. A column (controllable.
1 HPLC Lecture Mobile Phase Selection in Partition Chromatography Optimization of the mobile phase composition and polarity is vital for obtaining.
Reversed Phase HPLC Mechanisms Nicholas H. Snow Department of Chemistry Seton Hall University South Orange, NJ 07079
DR ZIAD W JARADAT PROTEIN BIOTECHNOLOGY BT 452 Chapter 3 HIGH PERFORMANCE LIQUID CHROMATOGRAPHY.
Chapter 32 HIGH-PERRORMANCE LIQUID CHROMATOGRAPHY High-performance liquid chromatography (HPLC) is the most versatile and widely used type of elution chromatography.
The geometry of capillary columns is fairly simple, consisting of length, internal diameter, and stationary phase thickness. Nevertheless, there are endless.
Chromatography CHEMISTRY Chromatography Chromatography is a technique for separating species based on physical or chemical properties. Usually.
Chromatography.
Analyte Ionization Lecture 3 Yuri Kazakevich Seton Hall University
Chem. 31 – 4/8 Lecture. Announcements I Exam 2 – Monday –Covering Ch. 6 (topics since exam 1), 7, 8-1, 17, and parts of 22 (up to and including retention.
Chem. 133 – 5/5 Lecture. Announcements Lab Report 2.4 due Thursday – can turn in today for reduction of late penalties Term Project Progress Report –
1 Introduction HPLC Process Lecture 1 Yuri Kazakevich Seton Hall University.
Using Chromatography to Select Effective Biomineral Growth Modifiers Tissa J. Thomas and Ryan E. Sours Department of Chemistry, Towson University, Towson,
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Introduction to High Performance Liquid Chromatography.
Created with MindGenius Business 2005® Performance parameters (Advanced) Theoretical Plate Model Performance parameters (Advanced) Theoretical Plate Model.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
Supercritical Fluid Chromatography SFC Chromatographic Fundamentals Practical Verification of SFC Theoretical Description of SFC / Scale-up SFC on a Preparative.
Method conditions Excellent resolution and fast run times 2 x OligoPore, 4.6 x 250 mm columns gave excellent oligomeric resolution for the PS 580 sample.
GC Advantages 1. Very Large N (Very Long Columns) 2. No Packing Material (A=0) 3. Simple Mobile Phase (Compressed Gas) 4. Universal Detectors (FID) 5.
High Performance Liquid Chromatography Instrumentation.
INTRODUCTION TO CHROMATOGRAPY
Identifying Applicability Domains for Quantitative Structure Property Relationships Mordechai Shacham a, Neima Brauner b Georgi St. Cholakov c and Roumiana.
Accuracy Based Generation of Thermodynamic Properties for Light Water in RELAP5-3D 2010 IRUG Meeting Cliff Davis.
CAN YOUR HPLC COLUMN DO THIS ?. Type B SILICA TYPE-C SILICA 
By- Bhavya, Harsh, Harshvardhan, Namrata, Ronit and Vidhatri
High Performance Liquid Chromatography. The chromatogram is a record of detector output Vs time as the analyte passes through the chromatography.
1 HPLC Lecture Displacement pumps Displacement pumps, on the other hand, is composed of a one directional motor driven plunger that pushes the mobile.
The Chromatogram  Terms:  Retention time  Peak area  Peak width (at half height, at base)  Peak height  Void time/volume  Adjusted retention time.
HPLC.
Why HPLC? Almost universal applicability Remarkable precision Highly commercially available (competition)
1 Prediction of Phase Equilibrium Related Properties by Correlations Based on Similarity of Molecular Structures N. Brauner a, M. Shacham b, R.P. Stateva.
Chem. 133 – 5/3 Lecture. Announcements Lab – Term Project Progress Report Due Today – Last Assignments: Term Project Poster and Peer Review Grading (Friday,
Instrumental Analysis (I) HPLC Tutorial 8. Graded presentation Students in groups of 4-5 individuals are asked to prepare a presentation (weight=5% of.
Instrumental Analysis (I)  HPLC Tutorial #7 PHCMt561 – 5 th Sem. Pharm.
3M Drug Delivery Systems 3 Introduction A family of hydrofluoroalkane-compatible excipients based on oligomeric lactic acid (OLA) has been proposed for.
3M Drug Delivery Systems 3 Maggi G. Tebrake a Monica Dolci b, and Roger M. Smith b a) 3M Healthcare Limited, Morley Street, Loughborough, Leics LE11 1EP.
Maggi Tebrake– Early Pharmaceutics & Technology, 3M Health Care Ltd, Loughborough Lindsey Gunby– Industrial Placement Student (EP&T ), 3M Health.
New Hydrogen-Bonding Stationary Phases for Liquid Chromatography.
Experiments in Analytical Chemistry
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
and Identification by Thin-Layer Chromatography
Biochemical instrumental analysis - 9 Dr. Maha Al-Sedik 2016 CLS 332.
High Performance Liquid Chromatography. What is HPLC ? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube.
Chem. 133 – 5/2 Lecture.
Chem. 133 – 4/27 Lecture.
High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography HPLC
Chem. 31 – 11/1 Lecture.
HPLC.
A guide for A level students KNOCKHARDY PUBLISHING
HPLC.
Chromatographic separation - classifying analytical separations; column chromatography, planar chromatography - gas chromatography; introduction, application.
An Introduction to Chromatographic Separations
High Performance Liquid Chromatography
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
High Performance Liquid Chromatography
Principle of separation of different components:
CHROMATOGRAPHY Chromatography : It is a physical method of separation in which the components to be separated are distributed between two phases, one.
High-Performance Liquid Chromatography
Global Discovery Chemistry, 11 August 2017
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
Transferring LC-UV to LC-MS.
CHROMATOGRAPHY.
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
High-Performance Liquid Chromatography
Presentation transcript:

Screening of a Sulfonamides Library by Supercritical Fluid Chromatography Coupled to Mass Spectrometry (SFC-MS). Preliminary properties-retention study. SFC User Meeting Cambridge 31 st May – 2 nd June 2006 Amaury Cazenave Gassiot Dr. G. John Langley

SFC User Meeting - Cambridge OUTLINE  Introduction  SOTLIB Library  Isocratic study  Retention models in chromatography  Polycratic study - Looking for linear relationships - Correlating data with physico-chemical properties  Conclusion and future work

SFC User Meeting - Cambridge INTRODUCTION  SFC-MS appears more and more as a technique complementary to HPLC for high throughput analysis  Importance of knowing which technique is more suitable for a specific type of analytes  Possibility of outlining a set of properties-based rules allowing prediction of the retention of a given compound by SFC ?  To investigate those questions: design of a small library of sulfonamides compounds to be screened by SFC

SFC User Meeting - Cambridge SOTLIB LIBRARY: NEUTRAL SET  Coupling of 4 sulfonyl chlorides with 3 amines  All compounds synthesized and analysed by SFC

SFC User Meeting - Cambridge SOTLIB LIBRARY: BASIC SET  Coupling of 4 sulfonyl chlorides with 5 amines  All compounds synthesized and analysed by SFC

SFC User Meeting - Cambridge ISOCRATIC STUDY: NEUTRAL SET (I)  Screening of the library using isocratic elution  Neutral set studied on: - 2-ethyl-pyridyl column 4.6x250mm - cyano column 4.6x250mm - diol column 4.6x250mm - bare silica column 4.6x250mm  Chromatographic Conditions: - mobile phase: 20% v/v MeOH in CO 2 - flow: 4mL.min -1 - temperature: 35°C - outlet pressure: 100 bars - injection volume: 4mL (~0.5mg.mL -1 )

SFC User Meeting - Cambridge ISOCRATIC STUDY: NEUTRAL SET (II)  Retention time related to structure of compounds  2-ethyl-pyridyl (2-EP) and cyano columns: tR tR  tR tR   On 2-EP phase: co-elution of 2 compounds, despite distinct physico-chemical properties.

SFC User Meeting - Cambridge  Different trend observed on diol and silica phases: benzimidazole derivatives eluted the latest  On bare silica column: compounds 3 and 9 co-eluting tR tR  tR tR  ISOCRATIC STUDY: NEUTRAL SET (III)

SFC User Meeting - Cambridge COLUMN COMPARISON  Compounds not more retained by a particular column  Same interactions between compounds and all four columns ?  Retention mechanism mainly due to free silanol groups ?  Method: isocratic 20% MeOH, 4mL/min, 35°C, 100 bars

SFC User Meeting - Cambridge  Screening of the library using isocratic elution  Basic set studied on: - 2-EP column 4.6x250mm - cyano column 4.6x250mm - diol column 4.6x250mm  Chromatographic Conditions: - modifier: MeOH + 0.1% v/v DEA - mobile phase: 20% v/v modifier in CO 2 - flow: 4mL.min -1 - temperature: 35°C - outlet pressure: 100 bars - injection volume: 4mL (~0.5mg.mL -1 ) ISOCRATIC STUDY: BASIC SET (I)

SFC User Meeting - Cambridge  Retention time related to structure of compounds  BUT: only with regards to sulfonyl part  Same trend as observed for neutrals: tR tR  ISOCRATIC STUDY: BASIC SET (II)  Diol columns: 4 compounds not eluted:

SFC User Meeting - Cambridge COLUMN COMPARISON  More differences than observed with neutral set  However retention close on all columns for most of the compounds  Retention mechanism mainly due to free silanol groups ?  Isocratic elution, 20% MeOH+0.1%DEA, 4mL/min, 35°C, 100 bars

SFC User Meeting - Cambridge LIMITS OF THE ISOCRATIC APPROACH  No simple correlation highlighted between physico-chemical properties and t R on the silica column  Is the isocratic approach right?  Indeed: methanol composition (20%) chosen arbitrarily  So, why 20% and not 30% ?  Retention time: the most obvious parameter, but is it the most appropriate ?

SFC User Meeting - Cambridge  More than the retention time, the capacity ratio k is a convenient way to normalize the retention of an analyte:  Most successful models of retention developed by Snyder 1 and Soczewinski 2, in reverse phase systems like ODS/H 2 O+MeOH:  In normal phase system, strong deviation observed, but linear correlation can be found in log-log coordinate system: 1.Snyder, L. R., Principles of Adsorption chromatography. First ed.; M. Dekker: New York, Soczewinski, E., Mechanistic molecular model of liquid-solid chromatography - Retention-eluent composition relationships. Journal of Chromatography A 2002, 965, (1-2), RETENTION MODEL IN CHROMATOGRAPHY (I)

SFC User Meeting - Cambridge  Regression analysis: calculation of intercept log k w and slope  log k w : standardised parameter more reliable than arbitrary isocratic log k  Start of “polycratic” study, aim: calculation of intercept “log k 0 ” and slope S RETENTION MODEL IN CHROMATOGRAPHY (II) log k = S x  + log k w

SFC User Meeting - Cambridge  Requirement: keep log k within a range of “practical interest” as defined by Schoenmaker et al. 1 : 0 < log k < 1  Getting the retention factor within the range: - slow eluting compounds: no difficulties since increasing  allows to elute them soon enough - fast eluting compounds: decreasing  doesn’t systematically allow sufficient increase in retention to comply with requirement  Consequence: some compounds to be removed from study  Analyses carried out three times, plotting of mean values « POLYCRATIC » STUDY 1.Schoenmaker et al. Journal of Chromatography 1979, 185,

SFC User Meeting - Cambridge EP COLUMN  10 compounds within k range  plot  vs. log k: R 2 > 0.98  log k 0 and S calculated for the 10 compounds

SFC User Meeting - Cambridge  7 compounds within k range  plot  vs. log k: R 2 > 0.99  log k 0 and S calculated for the 7 compounds SILICA COLUMN

SFC User Meeting - Cambridge  11 compounds within k range  plot  vs. log k: R 2 > 0.99 (except compound 6 at R 2 =0.92)  log k 0 and S calculated for the 11 compounds CYANO COLUMN

SFC User Meeting - Cambridge  8 compounds within k range  plot  vs. log k: R 2 > 0.97  log k 0 and S calculated for the 8 compounds DIOL COLUMN

SFC User Meeting - Cambridge CORRELATING DATA WITH COMPOUNDS PROPERTIES (I)  On none of the columns, log k 0 and S could be correlated with lipophilicity constants of the analytes (log P [ACD and Spartan], log D at pH 7.4) nor with pKa values.  However, other properties of the neutral set compounds calculated with Spartan, e.g.: - total dipole moment  - surface area A - volume V - electronic charges on single atoms  Multiple regression analysis performed to correlate properties with retention characteristics log k 0 and S

SFC User Meeting - Cambridge  On 2-EP column: when regressing log k 0 vs. , A and  min : log k 0 =  A –  min – R=0.95 when regressing S vs. , A and  min : S =  - 1.6x10 -5 A  min – R=0.90 exp log k 0 vs predicted log k 0 R=0.95 exp S vs predicted S R=0.90 CORRELATING DATA WITH COMPOUNDS PROPERTIES (II)

SFC User Meeting - Cambridge  On cyano column: when regressing log k 0 vs. , A and  min : log k 0 =  A –  min – 1.25 R=0.94 when regressing S vs. , A and  min : S =  - 2.2x10 -5 A  min – R=0.84 exp log k 0 vs predicted log k 0 R=0.93 exp S vs predicted S R=0.80 CORRELATING DATA WITH COMPOUNDS PROPERTIES (III)

SFC User Meeting - Cambridge  On diol column: when regressing log k 0 vs. , A and  min : log k 0 =  A –  min – R=0.97 when regressing S vs. , A and  min : S =  - 1.1x10 -5 A  min – R=0.95 exp log k 0 vs predicted log k 0 R=0.97 exp S vs predicted S R=0.95 CORRELATING DATA WITH COMPOUNDS PROPERTIES (IV)

SFC User Meeting - Cambridge  On silica column: when regressing log k 0 vs. , A and  min : log k 0 =  A –  min – R=0.99 when regressing S vs. , A and  min : S =  - 7.7x10 -5 A  min – R=0.84 exp log k 0 vs predicted log k 0 R=0.99 exp S vs predicted S R=0.84 CORRELATING DATA WITH COMPOUNDS PROPERTIES (V)

SFC User Meeting - Cambridge  Isocratic approach: highlighting of trends in retention  Polycratic study: CONCLUSION (I) - supposed better characterization of the retention - no correlation of log k 0 or S with lipophilicity constants or pKa - study of 12 neutral sulfonamides on 2-EP, cyano, diol and bare silica stationary phases - linearity found for log k = log k 0 + S x ϕ R 2 >0.97

SFC User Meeting - Cambridge CONCLUSION (II)  Correlating retention characteristics and molecular descriptors - Retention characteristics log k 0 and S correlated with total dipole moment μ, surface area A and atomic charge on the most negatively charged atom δ min - Encouraging results for log k0 which are correlated with molecular descriptors with R > 0.94 on all four stationary phases - Less promising results for S, especially on cyano and silica columns (R = 0.84). - Results to be considered with care, since obtained on small set of structurally similar compounds.

SFC User Meeting - Cambridge FUTURE WORK  Analysis of a set of 20 basic sulfonamides currently under way  Study to be extended to compounds of different structures  Recalculation of molecular descriptors by more powerful algorithms under way  Regression analysis using other descriptors has to be undertaken in an attempt to highlight better correlation (experimental log P to be measured)

SFC User Meeting - Cambridge ACKNOWLEDGEMENTS