NetSure™ RDB Series.

Slides:



Advertisements
Similar presentations
Cisco 6500 E-Series Chassis Up-grade
Advertisements

Isolation Verification Control Mining - Marine - Transit – Solutions LIVE Distributed By Locksafe Industrial Safety Equipment.
EMerge Browser Managed Security Platform Module 2 Hardware install.
BPS12 Battery Power Supply. December 2003 Page 2 Better Than Standard UPS systems Longer battery life –unique charging scheme DC power output –instead.
MineralScan Lite Installation Guidelines Digital Control Lab, LLC NW 6 th Street, Suite F Gainesville, FL Main Unit power 90 – 240 VAC 50/60.
Safety Photo of the Week Power Taps Collider-Accelerator Department Take 5 for Safety.
Power distribution box XD1 top DTTF_Crate XD2 middle DTTF_Crate XD3 bottom DTTF_Crate Connection to DTTF_Crate through cable USE H07 ZZ-F 3G1,5 RACK S1D01.
Office and Home Electrical Wiring and Safety Session 10.
© 2011 Ericson Manufacturing, Willoughby, Ohio
Make the most of your energy Make the most of your energy SM Add application photo in this area PowerLogic ® Branch Circuit Power Meter for data center.
CCTV SYSTEMS CAMERA POWER SUPPLIES.
Dealer Certification Section 2: Building the Network Physical Planning & Documentation Power Sources & Distribution Voltage Drop Calculations Copyright.
Figure 1: The GT-1000 Solar PV Technology Panel
1 PBX installation considerations BASIC TELECOMMUNICATIONS.
INTRUSION ALARM TECHNOLOGY
June 2008 R&D Center / BCS HW Team Introduction to iPECS P5 Hardware.
By Carlin Bright. Electricity The flow of electrons in a conductor.
A* candidate for the power supply Wiener MPOD-LV crate w/ remote control only (except for local on/off switch) Type “EC LV” Front or rear connections (reverse.
Low Voltage Power Requirement of TOF FEEs. Maximum tray. Low Noise:  Periodic and Random Distortion (PARD) < few mV RMS Floating.
Two Minute Drill #8 Copyright 2005 Ted "Smitty" Smith Practice Code Look Up.
ELECTRICITY. Electric Current  Currents are the rate that electricity flows thru a wire  2 types of currents:  Alternating Current (AC) electricity.
1 INTRUSION ALARM TECHNOLOGY POWER SUPPLIES. 2 INTRUSION ALARM TECHNOLOGY Security systems shall have a primary power source and a secondary power source.
EXAMPLE ELECTRICAL DESIGN OF A SMALL OFFICE
The New FTC Platform (Connecting your legacy hardware)
Printed 10/7/2011 SCOUT, REV5, WIRING KIT, GUIDE SONAR Connector: JST Length: 6.5 inches 28AWG Start: BreakFly End: Sonar 0, 1 FEMALE Connector: JST.
1/12 Ⅱ. N700E#0(comparison table) Items N700E N700E (Upgrade) Intelligent Input5ch6ch Analog Input1ch (V/I)2ch (V, I) Analog Output1ch Digital Output1ch.
Controls and Electrical Preferred Technologies Steve Pavis PH-DT-DI CERN Advel Power Supplies and ABB Circuit Breakers.
SGI Confidential Power Bay. SGI Confidential Power Bay Front View AC OK LED DC OK LED Alarm LED Release Latch Power Bay 1 Power Bay 0 Power.
Serial vs. Parallel Connections. Serial Connections Serial connections are positive-to-negative in a chain.
> Micropack System Concept January – Slide 2 Building blocks – Single position power core >Stand alone unit AC Input, L, N, PE, 1,5mm 2 DC Output,
First, let’s review the structure and use of a breadboard.
NFS System Components & Installation.
Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution Engineering Technology Division.
PR570 POWERITE II TRAINING Dedicated to Success in Electronic Servicing for 50 Years.
Sageon Power Module Distribution Sageon Rack Trim Pieces.
New product introduction:
9/18/2003Safety Review Electronics Electronics design LV, HV power supply Fusing Heat.
Copyright ©2014 , JAE Electronics, Inc. Confidential DW Series Overview JAE May 2014 Battery Connectors for Power Storage.
Cat Electric Power Compact Diesel – Next Generation Product Launch
Introduction to IP Cameras Over Coax. Replacing Analog Cameras With IP Cameras Over Coax Analog Camera RG59U Coaxial Cable 18/2 Power Cable Low Voltage.
© 2005 Avaya Inc. All rights reserved. Avaya – Proprietary & Confidential. For Limited Internal Distribution. The information contained in this document.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
FLATPACK Rev.5 September 2002 Updated versions may be available.
1 Sensors and Switches... WHAT’S IN THE BOX? 2 Sensors and Switches... SENSORS, CORDSETS & PROX SWITCHES.
CERN Giovanna Lehmann, Xavier Pons
Delta’s Contribution for OCP Solution 2014
Avaya ePDU Andy McDonald August 2008
G3 Metered Outlet and EATS30 Launch
Avaya VA Line-interactive UPS
RF Retrofit Kit installation guide
D Sequencer – Insertable
Lighting Branch Circuit and Small-Appliance Circuits for Kitchen
V7 UPS Sales Training.
GROUND-FAULT GROUND-CHECK MONITOR
UPS Connectivity Options: PPDM ( )
Guardian – X482-R Oasis – X1180-R Hybrid – X1180/X482.
NI Data Acquisition (DAQ) Wiring and Connections
Avaya ePDU Andy McDonald August 2008
Avaya Online UPS Options
Reader Swap out Guide.
PLC Front Panel.
EPRI Truck & Bus Meeting SAE Medium and Heavy Duty Vehicle
Door Heat Exchanger: Specification
Honeywell Fire Systems Group RFX SLC L1: Det.159 Mod. 159 SLC L2: Det.159 Mod. 159 SLC L3 ~ L10 EIA 485 EIA 232 RDP Up to 32 Noti-Fire-Net Onyxworks.
Presentation transcript:

NetSure™ RDB Series

NetSure™ RDB Series 48V Plug-n-Play Rack Distribution Designed to feed up to 8.6kW from 200A breaker Zero U, rear mount Plug-n-play connectors for tool-less add/move/change Includes ground plug Breaker trip notification Universal mounting – can be mounted on the left or right in both top and bottom cable applications Model options by application: 1-2U Rack Mount Devices 6 or 15 outlet (L6 or L15) versions Larger Rack Mount Devices 6 outlet (M6) version Blade Chassis and High Power Devices 2 or 3 outlet (H2 or H3) versions

Rack Distribution Concept DC Power System IT Rack IT Rack 20A Load 20A Load Zero U Power Strip 20A Load A side B side Output Breakers A side B side Quick Connect Plug What does distribution in the rack look like? By locating power conversion very close to the point of use, no more than a 4/0 cable is required to carry each of the (22) 8.5kW max branch circuits within 60’ of the DC UPS, minimizing the amount of copper required. Take for example racks full of blade servers, each requiring (3) 70A breakers per side. WE have developed a series of rack distribution units to easily provide this secondary distribution with quick connect plugs. Typical 4/0 Cables No conduit req’d in cable tray Rack Mount Server Example (15) 20A inputs / side Blade Server Example (3) 70A inputs / side

Available Models

NetSure™ RDB L6 NetSure™ RDB Model Outlets Power Rating Part Number Per Outlet Per PDU Max Watts Max Amps1 Max kW L6 6 420 10 2.5 60 547692 630 15 3.8 90 547693 840 20 5.0 120 547499 1 Max Amps rated at end of battery discharge (42V) 2 PDU power rating limited to 200A, 8.4 kW each All NetSure™ RDB Series PDUs are designed for up to 200A input

NetSure™ RDB L15 NetSure™ RDB Model Outlets Power Rating Part Number Per Outlet Per PDU Max Watts Max Amps1 Max kW L15 15 420 10 6.3 150 547694 630 8.42 2002 547695 840 20 547615 1 Max Amps rated at end of battery discharge (42V) 2 PDU power rating limited to 200A, 8.4 kW each All NetSure™ RDB Series PDUs are designed for up to 200A input

NetSure™ RDB M6 NetSure™ RDB Model Outlets Power Rating Part Number Per Outlet Per PDU Max Watts Max Amps1 Max kW M6 6 1,050 25 6.3 150 547696 1,260 30 7.6 180 547697 1,470 35 8.42 2002 547503 1 Max Amps rated at end of battery discharge (42V) 2 PDU power rating limited to 200A, 8.4 kW each All NetSure™ RDB Series PDUs are designed for up to 200A input

NetSure™ RDB H2 NetSure™ RDB Model Outlets Power Rating Part Number Per Outlet Per PDU Max Watts Max Amps1 Max kW H2 2 3,360 80 6.7 160 547500 1 Max Amps rated at end of battery discharge (42V) 2 PDU power rating limited to 200A, 8.4 kW each All NetSure™ RDB Series PDUs are designed for up to 200A input

NetSure™ RDB H3 NetSure™ RDB Model Outlets Power Rating Part Number Per Outlet Per PDU Max Watts Max Amps1 Max kW H3 3 2,100 50 6.3 150 547698 2,520 60 7.6 180 547699 2,940 70 8.42 2002 547501 1 Max Amps rated at end of battery discharge (42V) 2 PDU power rating limited to 200A, 8.4 kW each All NetSure™ RDB Series PDUs are designed for up to 200A input

Output Cables Quick connect to PDU Un-terminated to IT equipment 2 Models: 547613: Power Cord for H2, H3 Models - 4' Long 547595: Power Cord for L6, L15, M6 Models - 6' Long

Breaker Trip Alarm Scheme Alarm scheme for NetSure™ RDB Series -48 VDC signal provided to indicate a breaker has tripped Signal can be “daisy-chained” to connect to multiple power strips Alarm signal can be connected to NetSure™ controller, or to other monitoring system that accepts -48 VDC signal 2 position removable terminal block provides a simple customer connection point for alarm signal requiring only a stripped wire

PDU Rack Mounting Bracket Mounts in rear of IT rack Includes bracket and hardware to mount to one side of rack Left side or right side mounting P/N: 547665

Mating Input Quick Connect Kits Provides mating connector to input of NetSure™ RDB Series Installs on cables from NetSure™ DC Power System Includes mating SB350 housing and two contacts 4 kits to accommodate 1/0 through 4/0 wire QTY: 1 per distribution strip depending on input wire size KIT P/N Wire Size 547668 1/0 AWG 547669 2/0 AWG 547670 3/0 AWG 547671 4/0 AWG