Siemens Building Technologies Building Technologies Variable Frequency Drives Harmonics Overview.

Slides:



Advertisements
Similar presentations
“Power Factor” In Transmission System
Advertisements

Variable Frequency Drives Bypass Options
Copyright© Voltimum Experts – not to be reproduced without prior consent of Voltimum UK Voltimum Expert Topic – Power Harmonics.
Mike Thornton National Sales Manager
QUALITY AND TECHNOLOGY
Chapter 4 DC to AC Conversion (INVERTER)
Who is Stellar Tech?  Stellar Tech Energy Services is a wholly owned Canadian company  Manufacturer of WellMax Datalogger / Controller  Specializing.
VARIABLE SPEED DRIVES HARMONIC EFFECTS & EFFECT OF USE WITH LONG CABLES (100 – 300m) Electric Motors & Drives ….OUR VISION, YOUR SOLUTION ……. TOGETHER.
2010 ASHRAE Rocky Mountain Chapter VFD Fundamentals April 16, 2010 Jeff Miller - ABB © ABB Month DD, YYYY | Slide 1 1.
© Copyright 2008 ABB. All rights reserved /29/2008 Results-Driven Roadshow Cincinnati, 2008 Common Cures for Harmonics Larry Stanley RSE,Nashville,TN.
Variable Frequency Drives VFD Basics
POWER ELECTRONICS Instructor: Eng.Moayed N. EL Mobaied The Islamic University of Gaza Faculty of Engineering Electrical Engineering Department بسم الله.
LP33 Series UPS kVA 400Vac/CE
ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives.
EXPERIMENTAL STUDY AND COMPARATIVE ANALYSIS OF TRANSFORMER HARMONIC BEHAVIOUR UNDER LINEAR AND NONLINEAR LOAD CONDITIONS.
Application Types Variable Torque Constant Torque.
PSI Pump Systems Inc. 1(800) PSI Pump Systems Inc. 1(800) Variable Frequency Drives Presented by PSI Pump Systems Inc. “ Your Solutions.
Dry type transformers Zaragoza Traction application
Fundamentals of Power Electronics 1 Chapter 19: Resonant Conversion Chapter 19 Resonant Conversion Introduction 19.1Sinusoidal analysis of resonant converters.
Fundamentals of Power Electronics 1 Chapter 19: Resonant Conversion Upcoming Assignments Preparation for Lecture 2: Read Section 19.1, Sinusoidal analysis.
Power Electronics Chapter 6 AC to AC Converters ( AC Controllers and Frequency Converters )
Active Power in 1~AC mains Apparent / Reactive / Active Power ~ L ~ C ~ R pure resistor R : phase shift = 0° active power 1 pure reactance L : phase shift.
SPEED CONTROL OF THREE PHASE INDUCTION MOTOR WITH ENERGY SAVING
7154/7156 Variable Speed Drives
POWER SUPPILES LECTURE 20.
PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
Power Electronics Lecture-11 Inverters Dr. Imtiaz Hussain
Chapter 4 AC to AC Converters
Considerations for Selecting VFD’s Quentin Nesbitt, PE Agricultural Engineer Idaho Power Company.
150W Inverter - an optimal Presenter: Dr Gawie van der Merwe design in solar home systems.
ET3380 Principles and Methods of Electric Power Conversion David Morrisson MS,MBA Week 1.
1 EE462L, Fall 2011 Motor Drives and Other Applications.
What is a Harmonic The typical definition for a harmonic is
7154 VFD Presentation #2 May 2002 Paul Weingartner.
Alternating Current Chapter 12. Generating AC (12-1)
Variable Frequency Drives and Irrigation Pumps Stefanie Aschmann Bozeman, MT 11/30/11 1.
Voltimum Expert Topic – Power Harmonics. What are Harmonics? They are waveforms with frequencies that are multiples of the fundamental frequency (Typically.
8-1 School of Electrical Systems Engineering ABD RAHIM 2008 EET421 Power Electronic Drives - DC to AC converter / Inverter Abdul Rahim Abdul Razak.
EE1301/POWER ELECTRONICS AC voltage controller and cycloconverter
ECE 7800: Renewable Energy Systems Topic 2: Fundamentals of Electric Power Spring 2010 © Pritpal Singh, 2010.
7/08/2002PP.AFD.07 Harmonic Quality1 of 49 Yaskawa Electric America Harmonic Currents, Voltages and Your Building Power System.
VARIABLE FREQUENCY DRIVES FOR ID FANS By M.PRASHANTH REDDY 08C01A1029 N.G.PRATHYUSHA 08C01A1033 Under The guidance of P.Sampurna lakshmi.
Electricity Power/Energy Basics: In US household electricity is 120 volts AC – 60 cycles (therefore most appliances and electronic equipment require this.
7/15/2002PP.AFD.081 of 28 Power Quality Considerations When Applying Adjustable Frequency Drives Explanations and Various Countermeasures.
(SWTCHED - MODE POWER SUPPLY)
Chapter 9 CAPACITOR.
Function Generators. FUNCTION GENERATORS Function generators, which are very important and versatile instruments. provide a variety of output waveforms.
CLOSED LOOP SPEED CONTROL OF DC MOTOR WITH PWM TECHNIQUE
 2008 Kaeser Compressors, Inc., USA (V4.1) SFC Product Introduction “Specifications are subject to change without notice” 1 SFC Sigma Frequency Controlled.
Power Quality Issues Power Electronics Group.
Yaskawa Training Café Yaskawa Training Café – Through the Combined Efforts of Drives Engineering and Technical Training Services Welcome n To make this.
REVIEW OF CFL AND ITS HARMONIC IMPACT ON ELECTRICAL DISTRIBUTION SYSTEM Guide: Mr. Rijo Rajan, prepared by: Merin Lukose Lecturer, S7 EEE EEE department.
Energy Efficient Motors and Variable Speed Drives
Effects of Harmonics on Capacitors Electrical System
Yaskawa Electric America on Variable Torque Loads
IMPEDENCE - SOURCE INVERTER FOR MOTOR DRIVES
SPOC Automation and BECI- who are we?
Power System Harmonics
Five level diode clapmed inverter
Power Electronic Drives - DC to AC converter / Inverter
Robicon Perfect Harmony.
Amplifiers Classes Electronics-II
Amplifiers Classes Electronics-II
AC voltage controller and cycloconverter
Electronic Fundamental Muhammad Zahid
Dr. Unnikrishnan P.C. Professor, EEE
AC Drives Dr. Adel A. El-Samahy Department of Electrical Engineering University of Helwan.
INVERTERS. What is an Inverter? A static device that converts DC power into AC power at desired output voltage and frequency is called an Inverter. Applications.
Presentation transcript:

Siemens Building Technologies Building Technologies Variable Frequency Drives Harmonics Overview

Siemens Building Technologies Building Technologies Harmonics Overview What causes harmonics ? Non-linear load devices create harmonics when they convert ac to dc, dc to dc, dc to ac, and ac to ac. This can produce high levels of harmonic voltage and current distortion.

Siemens Building Technologies Building Technologies Harmonics Overview Harmonics operate at a frequency that is a multiple of the fundamental Harmonics operate at a magnitude that is inversely proportional to the magnitude of the fundamental In other words... the higher the harmonic order, the less effect it has on the waveform. In most cases, harmonic analysis is limited to the 13th harmonic.

Siemens Building Technologies Building Technologies Frequency is defined as the number of times a given waveform repeats itself every second. Example: the typical household line current impresses 115 volts AC, 60 times per second. Repeated 60 times every second 166 msec 1 cycle 0 Harmonics Overview

Siemens Building Technologies Building Technologies Harmonic currents operate at the same time as the fundamental, but at faster rates Harmonic currents are additive, producing a “distorted” sine wave. Fundamental = 60Hz 5th Harmonic = 300Hz Harmonics Overview

Siemens Building Technologies Building Technologies Harmonic Currents are currents that flow at the same time as a fundamental current, 60Hz frequency, but at multiples of the fundamental. For a typical 6 pulse inverter, these multiples are: –Fundamental = 60 Hz –5th Harmonic = 60 x 5 = 300 Hz –7th Harmonic = 60 x 7 = 420 Hz –11th Harmonic = 60 x 11 = 660 Hz –13th Harmonic = 60 x 13 = 780 Hz –17th Harmonic = 60 x 17 = 1,020 Hz Harmonics Overview

Siemens Building Technologies Building Technologies A harmonic current operates in “harmony” with the fundamental but faster; i.e. the 5th harmonic of the 60 Hz fundamental repeats itself 300 (60 x 5) times per second. Repeated 300 times every second 30 msec 1 cycle 0 Harmonics Overview

Siemens Building Technologies Building Technologies Harmonics Overview Harmonics have several harmful side effects: Can interfere with electronic equipment and people –through radiated (RFI) interference through the air –emitted (EMI) interference over power and control wires. Can cause an increase in supplied power (KVA) over what is really needed (kW or HP) –Entire AC supply line must be sized accordingly –End user transformers, switchgear, wires, contactors, and fuses have to be bigger. –The power company generator Can cause Poor Power

Siemens Building Technologies Building Technologies Poor Power... Reduces the Load Carrying Capacity of Your Electrical System! Transformers & wiring are sized by current capacity. If additional current is required due to low power factor, capacity for work producing current is displaced. Everything in your building is oversized to make up for poor power factor. Harmonics Overview

Siemens Building Technologies Building Technologies Harmonics – DC Capacitance Link V Rectifier D C Link Inverter Single or Three Phase Power C + - Current C A DC capacitance link provides voltage to the inverter between the peaks of the mains voltage waveform. Current only flows from the mains into the DC link when the mains voltage exceeds that of the capacitor. Current only flows when the mains voltage is near its peak, as shown. The larger the DC link capacitor, the shorter the period of current flow, and the higher the peak current.

Siemens Building Technologies Building Technologies Harmonic - Current Wave Form Ideal current wave but not attainable with a 6-pulse drive What the current wave form looks like with a 6-pulse drive Approaching a perfect current wave

Siemens Building Technologies Building Technologies Typical Drive Input Current Waveform I RMS = 75A Power = 12kW (x3) If current is sinusoidal Only 52A is required for the Same power. MM4 45kW Line Current Waveform (low impedance mains)

Siemens Building Technologies Building Technologies SED2 Typical Waveform I RMS = 53A Power = 12kW (x3) If current is sinusoidal Only 52A is required for the same power. SED2 11kW Line Current Waveform

Siemens Building Technologies Building Technologies DC Link Design Results 15HP Typical VFD Line Current Harmonics Spectrum 15 HP SED2 Line Current Harmonics Spectrum Meter deflection

Siemens Building Technologies Building Technologies Harmonics Competitive Analysis How do other VFD manufacturers address Harmonics? Some build in DC link chokes –This adds cost, weight and current losses Some offer line reactors –Rarely built-in to VFD - often offered as a separate option –Commonly mounted in bypass cabinet, or supplied in its own enclosure –Adds cost, weight and can cause nuisance tripping of drive on undervoltage Some build special 12 and 18 pulse drives –Extremely expense and not practical for most application under 100HP Some just ignore the problem

Siemens Building Technologies Building Technologies Harmonics - The SED2 Advantage SED2 is specifically designed for HVAC applications –Fans and pumps with variable torque load characteristics Sophisticated Siemens control technology enables the SED2 to significantly reduce current harmonics by dramatically reducing the size (capacitance) of the DC link. In lieu of large (high uF) electrolytic capacitors used in most VFDs, SED2 uses much lower value (low uF) plastic capacitors. Typical 15Hp VFD: DC link capacitance of 1000uF SED2 15HP VFD: DC link capacitance of 20uF

Siemens Building Technologies Building Technologies Siemens SED2 VFD Advantages Low harmonics design Small enclosure size Many standard features Reduces operating cost Low power losses/high efficiency Minimal effect on customer power Wide power range – from ½ to 125 HP