Philips End Tidal CO2 Monitoring.

Slides:



Advertisements
Similar presentations
How To Install RAM In Laptop Installing Larger RAM is the easiest way speed up your laptop computer. This Post will guide you about installing laptop computers.
Advertisements

Module 3 Configuring Hardware on a Computer Running Windows XP Professional.
Power Module – Setup Before using the Power Module (PM) to power the HeartMate II or XVE LVAS and optional Display Module or System Monitor, prepare the.
lyoungblood ******** This is a standard login screen to gain access to the NoteShare program. Click the “OK” button to continue.
Components: Sansa Clip Mp3, earbuds, USB cable, Quick Start Guide.
Optional, Advanced EMT Capnography/ End-tidal CO 2 Monitoring.
CO2 Physiology.
Oxygen Administration. BLOOD GASES  To measure the lungs ability to exchange O2 and carbon dioxide efficiently.  Test arterial blood for concentrations.
Respiratory Calculations
Practical Nursing Diploma Program - Semester 2 Lab Oxygen therapy, Incentive Spirometry, Pulse Oximetry &Sputum Collection.
O2 Administration: Oxygen Therapy and Pulse Oximetry Gail M. Maier, PhD., R.N. Associate Director The Ohio State University Wexner Medical Center.
Boussignac CPAP System
Oxygen Administration R/C MERT Medic Assistant Lesson V.
Module A-2 Oxygen Therapy. Assembling Oxygen System Nasal Cannula Nonrebreather Mask.
At Your Service Dining Directions. Navigation:  Go to the Request Meals button on TV Main Menu  Use the Arrow keys to move up, down, left or right 
NUR 232: PROCEDURAL GUIDELINE 25-1: CLOSED (IN-LINE) SUCTION.
McKesson Upgrade - ER 11/12 What is ER 11/12? ER is “Enterprise Release” and 11/12 is the software version. This release will upgrade many parts of the.
Drawing Blood From a Hickman Catheter
Flight 60 The Most Versatile Autonomous Ventilator 1 Confidential.
IT&S information technology and services (Run as Slide Show) Laptop Encryption – Password Change (Run as Slide Show)  As a user of an encrypted laptop.
E | W | E | W | NHS e-Referral Service Referring Roles Issued: 3 June.
What Kind of Tube is This?!
CAREERSOURCE GC BOARD AND CENTER SETUP FOR USE WITH IPHONE, IPAD, AND SELECT IPODS.
CareConnection’s PowerNote. Accessing PowerNote – Step 1.
Usage Guidelines Throughout this template you will find tip-boxes to the left of the slides. To remove this box from the final presentation, simply click.
Setting up the NICO monitor to measure pulmonary dead space fraction (V d /V t )
Welcome to the Sinclair Community College Online Employment Applicant Tutorial.
Oxygen Therapy Equipment.
Mosby items and derived items © 2007, 2004 by Mosby, Inc., an affiliate of Elsevier Inc. Airway Management and Ventilation Team Work Chapter 6.
O FFICE OF S CIENCE & R ESEARCH OSR O FFICE OF S CIENCE & R ESEARCH OSR Welcome to the Research Navigator Institutional Biosafety Committee (IBC) Learning.
Know your Os? How much Oxygen is the patient on? How much does the patient need? How’s this mask work? Is this thing hooked up right?
Oxygenation And Ventilation
Developed By Dari Calamia Southeastern Louisiana University College of Nursing and Health Sciences School of Nursing Spring 2014.
Module 2: Adding Hardware to Windows XP Professional Clients.
Module 3: Configuring Hardware on a Computer Running Windows XP Professional.
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
Presented By: Diana Gedamke, BSN, RN, CCRN Marion College - Fond du Lac Masters of Nursing Student.
LSM780 Live Cell Turn On/Turn Off Instructions Kim Peifley 07/13/15.
Using Stress Analyzer for Tensile Testing © 2012 Project Lead The Way, Inc.Principles Of Engineering.
Prepared by Dr. Irene Roco
Carbon Dioxide Monitoring
Information for students 2009 School Certificate Online Computing Skills Test including special examination provisions.
Instructional E-Classroom Instructional Guide Seneca College, Audio-Visual Services.
Capnography: Current and Future Use by EMS Presented by: Tim Ludwig EMT-P.
Student will be able to explain the various methods of oxygen administration and the role of the NA. Student will be able to list the safety precautions.
EPICOLLECT Maggie Ortiz, EERI. EpiCollect Tutorial  This is a short tutorial prepared by EERI to walk you through creating an entry using EpiCollect.
Photo Story. How to use Photo Story Photo Story 3 can be located in the Accessories folder on school computers. You will need to have your pictures already.
Capnography The EMS Version By: Ryan Felish. Why Capnography? Capnography – the measurement of carbon dioxide (CO2) in exhaled breath. Capnography provides.
Montgomery County Fire Rescue Medical Ambulance Bus 20 Patient Capacity.
Replacing the Main Monitor 1.Open Lower Main Door, and turn off machine power 2.Open the upper main door 3.Disconnect the video and power plugs from the.
E | W | E | W | NHS e-Referral Service Referring Roles Issued: 27 th.
Thermistor Temp. (°C) Thermometer Temp. (°C) Thermistor Temp. vs. Thermometer Temp. Figure 1. Salter Labs ThermiSense ® [3] Figure 2. Thermistors measuring.
Capnography: Defined and Clinical Applications
No ventilation –yet full oxygenation: Key point 1
Recording with the Sony NSCGC-1
MDX-R3 INSTALLATION PROCESS NON-ADJUSTABLE CONCRETE POOLS
Device Specifications Sleep Disordered Breathing
Troubleshoot HP Laptop Charging Problem
Conscious Sedation March, 2012.
Alarm Sound Tutorial.
Using Stress Analyzer for Tensile Testing
Pulse Oximetry.
Effect of citrate anticoagulation on CO2 extraction during low flow extracorporeal veno-venous CO2 removal therapy. P Morimont, S Habran, R Hubert, T Desaive,
End Tidal CO2 (EtCO2) and Capnography
Lesson Seven: Customizing Columns in Patient Lists
Assessment of Airflow in Sleep Studies by Oronasal CO2 Detection
To modify a requisition, enter the requisition number and click OK or press enter. You can enter sign to return to the last requisition you were.
SpO2 at baseline, pre- and post-intubation.
Insulin Multi-Dose Vial (MDV) for Multi-Patient Use
Presentation transcript:

Philips End Tidal CO2 Monitoring

We now have the ability to perform end tidal CO2 monitoring using the bedside Philips monitors. There are 2 different microstream products in the service center which will allow you to either monitor the non-intubated patient using a nasal cannula Or an intubated patient using an in-line attachment.

2 modules available… Locked up in T3 Philips monitor module (brick) with ETCO2 outlet (behind sliding segment)

Microstream CapnoLine that has nasal cannula with CO2 detector. Nasal prongs with projection piece that extends over mouth To flowmeter and module Microstream CapnoLine that has nasal cannula with CO2 detector.

Philips in-line adaptor for use with intubated patients

These are chargeable items! Both the microstream cannula for non-intubated patients and inline adapter for intubated patients are located in the service center. These are chargeable items!

View of Philips monitor with standard module in place View of Philips monitor with standard module in place. The ETCO2 module cannot be piggybacked onto this as shown here.

Remove standard module and slide ETCO2 module onto it and attach to monitor.

Slide door down and screw microstream catheter into outlet Slide door down and screw microstream catheter into outlet. The CO2 information will automatically display on screen.

CO2 display

This illustrates microstream connected to module and O2 line connected to flowmeter.

While using nasal cannula, if you have to go above 5 liters, change to a mask. It is ok to place an oxygen mask over the nasal cannula, but you must remove the cannula from the oxygen source and only connect the mask to O2. Normal CO2 levels are 35-45. Pre-set limits are 30 and 50. You may have to adjust accordingly if patient has a different baseline. This is a “plug n play” device. You only need to attach to the module and no calibration is required. Please give the monitor a minute or so to detect the CO2 level.

The CO2 readings do not equal the results you would obtain from an arterial CO2 measurement, therefore you are monitoring for trends in the CO2 readings. Please remember to charge for the microstream items you use! Please return the CO2 module to T3 when you are finished so it can be easily located! ETCO2 monitoring is REQUIRED if you are performing deep sedation in the ED. (See new policy on deep sedation that was disseminated in March2011 policy updates!) Please ask the physician if there is any question if CO2 monitoring is indicated.