JBT FoodTech PED 97/23 EC EN 378 Staffan Sundsten 2013-11-06.

Slides:



Advertisements
Similar presentations
1 HCFC Phase –out in Air Conditioning Sector Background, Challenges and Progress Sidi Menad SI AHMED 17 TH October 2012.
Advertisements

REFRIGERATION Refrigeration may be defined as the process of removing heat from a substance under controlled conditions and reducing and maintaining the.
CCNA1 v3 Module 9 v3 A+ CORE JEOPARDY K. Martin CCNA1 v3 Module 9 RouterModesWANEncapsulationWANServicesRouterBasicsRouterCommands RouterModesWANEncapsulationWANServicesRouterBasicsRouterCommands.
Iglu Cold Systems Winning with Co2. Iglu Cold Systems is one of an exclusive group of companies to have invested in the development of a complete range.
Presentation on Building a Robust Refrigeration System By P. Sudhir Kumar Frick India Limited.
6 Introduction to Refrigerants. 6 Introduction to Refrigerants.
SECTION 4 ELECTRIC MOTORS UNIT 9
Comparison between American and European Pressure Vessel Rules
New Refrigerants Question Time Introductory Comments Ray Gluckman Director, Climate Change SKM Enviros April 26 th 2012, RAC, London.
R22 Phase Out Presentation To inform our customers of the single most important changes to the air conditioning industry in modern.
System and Component Efficiency with Refrigerant R410a A. T. Setiawan 1, A. Olsson 2, H. Hager 2 1 Department of Energy Technology, Div. Of Applied Thermodynamics.
REFRIGERATION & AIR CONDITIONING DIVISION Hydrocarbons for Domestic Appliances Dr.-Ing. Jürgen Süss VP R&D Brussels, October 2009.
Overall issues for adequate design for high-ambient temperature operation by: Samir Hamed Petra Engineering Ind. Co. Rtoc member.
ISAT Module III: Building Energy Efficiency
EGR 334 Thermodynamics Chapter 10:
Refrigerant Management
Section 2: Safety, Tools and Equipment, and Shop Practices
S3: Module D Physikalisch-Technische Bundesanstalt Session 3: Conformity Assessment Module D Peter Ulbig, Harry Stolz Belgrade, 31 October.
Dr Daniel Colbourne 36th Meeting of the Open-ended Working Group of the Parties to the Montreal Protocol – Side Event UNEP.
U D T Workshop on the Pressure Equipment Directive, Warsaw June 2004 INTERFACES BETWEEN NATIONAL LEGISLATION AND DIRECTIVE 97/23/EC SYSTEM OF ENSURING.
Overview of EU Regulations affecting the use of Fluorinated Greenhouse Gases Tim G.A. Vink Director Regulatory Affairs, Compliance & QA Honeywell Fluorine.
Session 5 Overarching and cross-cutting issues on technical aspects of HFC management.
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
Mahendra Senevirathne Project Coordinator National Ozone Unit Sri Lanka 17 September
Refrigeration Plant & Components. Type of Refrigeration System  Most common type: vapour compression refrigeration system – liquid refrigerant throttled.
Refrigerants. Background 1850’s – 1870’s: ammonia, ammonia/water, CO 2 Early 1900’s: SO 2, methyl chloride used for domestic refrigerators 1930’s: halocarbon.
GRPE GRPE CGH 2 Experts (A sub-group of the GRPE Informal Group “Hydrogen/Fuel Cell”) JASIC Presentation At The GRPE CGH 2 Experts Meeting.
WEL COME TO COE RAC SECTOR ITI UTTARSANDA. ADVANCE MODULE :-I Advance Module in Domestic, Commercial Refrigeration and Air Conditioning.
Ozone Depletion Reducing the manufacture and release of halogenated organic chemicals.
In the 1970’s, scientists discovered the dangerous impact that CFC’s have in the Earth’s atmosphere. They were destroying the ozone layer which protects.
CFC Phaseout Implications for Commercial Cooling Presented by Marie Broadwell US Environmental Protection Agency, Region IX (415)
PED and Swedish regulations
05/01/20161 Benny Hoff TÜV NORD Sweden AB AFS 2005:3 Inspection of pressure equipment.
Esbe Rotary Motorized valves The ESBE Rotary Motorized valves (mixing valves and actuators) are used to control heating and cooling in buildings. We offer.
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
SAFETY AND INFRASTRUCTURE REQUIREMENTS FOR TEL-2 INSTALLATION IN THE LAB Paolo Magagnin (BE-BI-ML) 24 – April
- Generals for PED matters - Definition of pressure vessel and classes - Who is who according to PED - Definition of pressure vessel + codes for XFEL -
00 Heat pumps by Kenneth Hoffmann. Why NH 3 Heat pump? NH 3 Heat Pump sizes Case stories CO 2 Heat Pump NH 3 Heat Pump applications NH 3 Heat Pump sizes.
Basic Refrigeration. Star Refrigeration Wednesday 12 September 2007.
Anhydrous Ammonia (NH 3 ) as a Refrigerant An Overview.
Contract: EIE/07/069/SI Duration: October 2007 – March 2010Version: July 7, 2009 Ventilation for buildings Energy performance of buildings Guidelines.
REFRIGERATION SYSTEMS Er. Gagandeep kaur Associate Prof., Electrical Engg. PTU Giani Zail Singh Campus, Bathinda. Id:
Crab Cavity Technical Coordination meeting:
The application of the PED on the design codes for cryogenic equipment and future developments foreseen in this field Paris, 06/09/2016 l Hervé BARTHELEMY.
Refrigeration & air conditioning
.. Level 3 Air Conditioning Inspections for Buildings
Refrigeration and Heat Pump Systems
Strategy for conformity of non-standard cryogenic equipment
Introduction to Food Engineering
Commercial Refrigeration Trends and challenges for RECS
EET 422 EMC & COMPLIANCE ENGINEERING
. Level 3 Air Conditioning Inspections for Buildings
High Quality Ammonia purifier for Refrigeration Plants | Maniks
THIRD ANNUAL CO3OL WORKSHOP
Third Party Activities for FH1 Project
Experience in Conformity Assessment of Products and Services  for Russian NPPs and Overseas Nuclear Power Plant New Builds Yury Meltsov Aug
High Performance Regulating Valve Manufactured by Maniks
Regulating Valve for Refrigeration Systems Manufactured by Maniks
Maniks Desuperheater a High Performance Energy Saving Product
Refrigeration Service Sector for energy saving, safety and the environment protection: Key activities for Art.5 Countries Paris - January, Madi.
Refrigeration Systems Regulation, Standards and Guidance
Refrigerants.
Pressure Equipment Workshop September 2007 – Day 1
Refrigeration Systems Regulation, Standards and Guidance
Mattias Skafar Head of Quality Division
Quality Regulation for Mechanical Equipment RESSQ – Mech
INTERFACES BETWEEN NATIONAL LEGISLATION AND DIRECTIVE 97/23/EC
Workshop on the Pressure Equipment Directive, Riga,
ODS AND ALTERNATIVES IN RAC SECTOR
A presentation On “ REFRIGERANTS ”
Presentation transcript:

JBT FoodTech PED 97/23 EC EN 378 Staffan Sundsten

2 CE-marking…why?  Before all countries had there local regulations…  Easier product trade in europe and worldwide  Safer products both for environmental and humans  CE-mark secures manufactor taking full responsibility regarding european directives CE = “Conformité Européenne” wich means fulfills CE-directives CE-directives = European Law

Refrigeration directives…  Pressure Equipment Directive - 97/23 EC (PED)  Machine directive /42 EC (MD)  Low Voltage directive /95/EC (LVD)  Electromagnetical directive /108/EG  EN = C-standard Design according to this standard means 3 Directives Fulfilled!

Pressure Equipment Directive (PED 97/23 EC) The pressure equipment is classified according to 4 categories (I-IV) The categories are determined by: –Pressure (max pressure the equipment is made for) –Volume (for pipes: diameter) –Content (medium) The category is set with the help of nine (9) different diagrams

Diagram 1- Pressure vessels, Ps= Max allowed pressure in bar that the supplier state that the pressure vessel are designed after.

Diagram 7. Pipes, DN = The nominal size of the pipe.

Pressure Equipment Directive (PED 97/23 EC) The category give a so called Module according to the table below. The Module gives the extent of the control required. Category ICategory IICategory IIICategory IV Module AModule A1 Module D1 Module E1 Module B1 + D Module B1 + F Module B+ E Module B + C1 Module H Module B + D Module B + F Module G Module H1

Pressure Equipment Directive (PED 97/23 EC) technical file… Module G:  General description assembly (system overview)  Flowchart  List of used standards  Design calculation  Declarations of conformity  Risk assessment PED/MD  Technical file installation (WPQ,PQR, NDT….)

Design standard refrigeration systems world wide  European refrigeration standard: EN 378  American refrigeration standard: ISO/CD 5149  Australian refrigeration standard: AS/NZS

To fulfill directives there are harmonized standards… 10  EN 378:2008 Refrigeration systems and heat pumps…  EN Safety and environmental requirements.  EN Design, construction, testing, marking and documentation.  EN Installation site and personal protection.  EN Operation, maintenance, repair and recovery.

Other important standards related to EN 378-2…  EN Refrigeration system (design capacity safety relief valves/lines)  EN14276 (general requirements of pressure vessels/pipes refrigeration)  EN (industrial piping…welding and materials)  EN (design pressure vessels)  EN (Approved Low temperature materials)… 11

What do we sell?  Modules/units  Plant  Assembly JBT delivers units and separate declaration of conformities JBT delivers a complete unit but the customer is responsible for integration and an accredited notified body approves installation. CE certificates on sub units. JBT delivers a complete assembly– JBT is integrator and supplies CE certificate on system

Who is the integrator and responsible for the approval? There are three different players in the project that can take on the roll as an integrator:  Refrigeration contractor - The company installing piping and the other equipment.  JBT – In this case JBT delivers a complete refrigeration system with subunits from several different suppliers, including piping.  The customer – In this case the customer is building the system himself with internal resources. 13

14 Important to buy components as part assemblies and decide who is integrator! Compressor Pack Condensor LVS Pipes Vessels

Final approval - JBT declaration of conformity - Certificate from notified body Approval process with notified body… 15 Design and documentation according to EN Design & documentation communicated - Design -Declaration of conformity - Calculations safety relief line&pipes - Risk analysis etc Pressure test & 1 st inspection Approval installation refrigeration system -operators manual - Manufactor plate - Technical file installation company Approval technical file

16 Declaration of Conformity according to 97/23 EC… should contain:  Name and address manufacture  Description of pressure equipment/Assembly  Module and Category  Harmonized standards used  References of other applied directives  Name and address of notified body  Sign from authorized represented manufacture  Certificate examination  See example of JBT-declaration…

17 See example of JBT-declaration… Word document

Learnings approval process  Declaration of conformity according to PED 97/23  Safety relief valves (calculations, pressure protocol, design etc)  To check that over flow valves are safety valve approved  Minimum Pipe thickness to be calculated all projects  Risk assessment according to MD 2006/42 and PED 97/23 all projects where JBT Foodtech is integrator.  To assure that installation company have welders certificate that covers pipe sizes 18

Some remarks from inspections with notified body… 19 Remark: Overflow valve not approved as safety valve! Action: Change valve and repipe. Remark: Safety valve flanges not approved! Action: Change flanges

Second hand Pressure equipment 20  PED 97/23 EC The application of and compliance with the Directive is mandatory from 29 May Equipment manufactured before :  Fulfill directive 89/655 EC (minimum directive for working equipment ) or to fulfill local rules  Need to check with local notified body the demand of: - Documentation - Risk assessment

21 SOME REFRIGERANTS AND ITS IMPACT ON ENVIRONMENT AND HUMAN SAFETY

22 NATURAL REFRIGERANTS Natural refrigerants are the answer for high capacity and high efficiency operation. Air - R 729 Water - R 718 Ammonia - R 717 Carbon dioxide - R 744 Hydrocarbons, such as propane - R 290 and isobutane - R 600a

NH 3 – Ammonia - Because of the characteristic smell, ammonia it is the only refrigerant in the world that warns long before it is dangerous and gives persons chance to move away. - Ammonia is toxic when inhaling, corrosive to the eyes, respiratory, skin and flammable at certain conditions. - Therefor it has to be treated with care and all ammonia systems must be designed with safety in mind. - At the same time, unlike most refrigerants, Ammonia has a characteristic smell that can be detected by humans at very low concentrations which give a warning signal if having leakage. - Already at around ppm you will feel very uncomfortable. 23

Energy efficiency Ammonia is one of the most energy-efficient applications, the application range from high to low temperature. Normally flowing ammonia system is 15-20% more energy efficient than a DX R404A counterpart. Environment Ammonia is the most environmentally friendly refrigerant. It belongs to the group of so-called "natural" refrigerants, and it has both GWP (Global Warming Potential) and ODP (ozone depletion potential) of zero Smaller pipe sizes Both vapour and liquid ammonia requires smaller diameter than most chemical refrigerants. 24

Better heat transfer Ammonia has better heat transfer properties than the majority of chemical refrigerants and therefore allows devices with a smaller heat transfer area used. These properties also favours the thermodynamic efficiency of the system and reduces the operational costs of the system. Refrigerant cost In many countries, the cost of ammonia (per kg) significantly lower than the cost of HFC Safety As described earlier, Ammonia is toxic when inhaling, corrosive to the eyes, respiratory, skin and flammable at certain conditions. That is why it must be handled carefully, and all the ammonia systems must be designed with safety in mind. 25

In Sweden: NGV (24 h): 20 ppm TGV (15 min): 50 ppm Alarm levels: C: Leakage, non acute: ppm B: Acute: ppm A. High level, plant is stopped = Protection of people > 3000ppm 26

SYNTHETIC REFRIGERANTS 1. CFC (Clorofluorcarbon - a member of the FC family containing only chlorine, fluorine and carbon.) The Montreal Protocol of 1987 has phased out the production of CFC refrigerants. CFC is not to be used at all since January 1, The actual CFC refrigerants are: R 12, and azeotropic blend R

2. HCFC (Hydrofluorocarbon - a member of FC family containing hydrogen, chlorine, fluorine and carbon.) HCFC has limited future for new design. HCFC are not allowed to be used in new installations or to re fill. A total stop is expected from Jan 1, The main HCFC refrigerant is: R 22 and blends with R

3. HFC (Fluorohydrocarbons - a family of chemicals containing fluorine hydrogen and carbon.) HFC refrigerants are the answer to many refrigeration applications. Pure HFC or blends should be avoided for large size food freezing and food preservation. Below some HFC as alternatives to R 22 29

R134a can be an option upon conversion in cases where a power loss can be accepted or if the compressor displacement can be increased enough without other factors adversely affected. Suitable mainly for chilling applications. Oil change required R404a (R507) is usually the best option in the refrigerator and freezer facilities but an increase in power output and higher condensing pressure must be considered. In air conditioning the energy efficiency is reduced and electrical output will increase significantly. Oil change required. 30

31 R407C is a proven alternative in facilities with appropriate heat exchangers but requires that the oil is changed to ester oil except in rotary compressors which typically special low viscosity alkyl benzene oils are recommended. R417A (Isceon 59) is poorly documented but is interesting when the cost of oil change is considered too high while capacity reduction and some uncertainty is acceptable, for example, if the unit is to be replaced relatively soon. R410A is not an option for conversion of existing R22 systems

For small refrigeration plants (~30-50 kW), HFC is attractive since the investment is much less than if installing an ammonia plant. Freon's are not normally considered as dangerous for people, but it is well known that Freon's has a very big impact on the environment. 32

GWP Global warming potential, compared to the GWP of CO 2. All GWP figures here are based on the 100 year time horizon. ODP Ozone Depletion Potential - compared to ODP of R 11 which is defined as 1. RefrigerantODPGWP R 22 HCFC R 134a HFC pure refrigerant01300 R 404A HFC zeotropic blend03800 R 407C HFC zeotropic blend01600 R 410A HFC zeotropic blend01900 R 507 HFC azeotropic blend03800 R 290 propane03 R 600a isobutane03 R 717 ammonia00 R 744 carbon dioxide01 33

34