Mass Spectrometer Autosampler Jake Ahrens Stephen Pearson Kyle Sala Seth Yellin Project Mentor: Professor Jane Hill.

Slides:



Advertisements
Similar presentations
Mass Spectrometer Auto Sampler Kyle Sala Jake Ahrens Stephen Pearson Seth Yellin.
Advertisements

Seth Yellin Kyle Sala Stephen Pearson Jake Ahrens.
Controller Tests Stephen Kaye Controller Test Motivation Testing the controller before the next generation helps to shake out any remaining.
Next Home Visio2 troubleshooting guide Start the slide show then click Next.
Sampling and Measurement for Volatile Organic Compounds
Lecture 8b Gas Chromatography.
Gas Chromatography, GC L.O.:  Explain the term: retention time.  Interpret gas chromatograms in terms of retention times and the approximate proportions.
What is Arduino?  Arduino is a ATMEL 168 micro-controller kit designed specially for small projects  User friendly IDE(Integrated Development Environment)
Chromatography Integration and Trouble-shooting
Mechatronics Department Graduation Project II. OutlineIntroduction. Methodology. Mechanical Design. Control Design.
An Introduction to Flame Atomic Absorption Spectrometry (FAAS) Steve Badger and Charity Wessel.
ORYX Microbatch Screening Ran Meged -1-. Microbatch oil protein & reagent solution -2-
INTRODUCTION TO ROBOTICS INTRODUCTION TO ROBOTICS Part 4: Sensors Robotics and Automation Copyright © Texas Education Agency, All rights reserved.
Happy Home Helper Jeremy Searle Apr 28, 2004 A Learning Home Automation System.
AquaGlo Water Detector Kit For Detecting Water in Jet Fuel
Jake Ahrens Stephen Pearson Kyle Sala Seth Yellin.
Jake Ahrens Stephen Pearson Kyle Sala Seth Yellin.
Kyle Sala Jake Ahrens Stephen Pearson Seth Yellin.
© Swagelok Company, 2006 IFPAC Miniature Modular Stream Selection Valves Switching Valve CPAC NeSSI Workshop May 11, 2006.
Methods Monitoring Polar Compounds Using Membrane Extraction and High-Speed Gas Chromatography Authors: Jonathan Maurer, Dr. Anthony J. Borgerding* Department.
University of Massachusetts Amherst InteLock TM Advisor: Professor Ganz Team: Emmanuel Seguin Christos Tsiokos Josh Coffin Anh-Kiet Huynh Remote Access.
Team 12 Amelia House Paul Jaffa Johanna Miller Brian Ortega.
Feeds Computer Applications to Medicine NSF REU at University of Virginia July 27, 2006 Paul Lee.
Gas Chromatography And Mass Spectrometry
Gas Liquid Chromatography
Electro-Pneumatics Module 1
Monitoring Well Sampling. SAP (Sampling Analysis Plan) SAP (Sampling Analysis Plan) Frequency Frequency Purging Purging Pumps and Bailers Pumps and Bailers.
Section 2.1 Controlling the Flow of Electrical Current.
Project # Team Members: Jeff Youngs, ME Jon Schneider, ME Ashish Rathour, EE Glenn Carroll, EE Tai To, EE Mayank Rathour, EE Faculty Advisors: Faulty.
Patrick Lazar, Tausif Shaikh, Johanna Thomas, Kaleel Mahmood
By, Blessy Babu. What is Gas Chromatography?  Gas spectroscopy is a technique used to separate volatile components in a mixture.  It is particularly.
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
© Process Analysis & Automation 2005 Short Course “I want to Automate that Process” Malcolm Crook.
Wearable Sensors Final Presentation Problem Background Inferred Transmission (short range) Bulky Design, hard to wear 20 Samples per second.
Qualitative Data Analysis. 2 In This Section, We Will Discuss:  How to load data files.  How to use Signal Options for data display.  How to apply.
Raul Garcia-Sanchez Research Investigator: Dr. Paul R. Mahaffy Code 699, NASA Goddard Space Flight Center Research Mentor: Dr. Prabhakar Misra Department.
Circuits and Electronics. Circuits A circuit is a closed path through which a continuous charge can flow. A circuit is a closed path through which a continuous.
ICP Shutdown. Pump Flush the nebulizer spray chamber with acid for 5 minutes by choosing the location of the 3% HNO3 and moving the sample needle “position”.
4-2 Sources of DNA.
IChemExplorer iChemExplorer ™ Chemistry Screening Tools.
Home Guard Security System. Introduction & Basic Ideas Home Guard Security System.
Development of a headspace solid-phase microextraction method coupled to gas chromatography (HS-SPME GC-MS) to capture and analyze the volatile organic.
Thermoelectric Energy Conversion Roberto Dimaliwat, Galena Park High School Galena Park ISD Professor/mentor Choongho Yu, PH.D Mechanical Engineering.
P16221 – FSAE Shock Dynamometer System Level Design Review September 29, 2015.
Mass Spectroscopy By Sandip, Amy & Jocelyn. Steps of Mass Spec The steps in the mass spec include: Ionisation: atoms are ionised by knocking one or more.
HPLC – High Performance Liquid Chromatography
Incoming Power Grid Monitor TEAM #3: JAMES MCCORMICK, ZHIHOUG QIAN, JACOB JEBB, VICTOR EZENWOKO, ALEX LANGE FACILITATOR: DR. ASLAM SPONSOR: GREAT LAKES.
INTRODUCTION TO ROBOTICS INTRODUCTION TO ROBOTICS Part 4: Sensors Robotics and Automation Copyright © Texas Education Agency, All rights reserved.
Created with MindGenius Business 2005® Instrumentation (1) Instrumentation (1) Origins Preparative column chromatography (Glass columns) Internal diameter:
LCMS-325 TQ Operation Chem 115 Paul Hrvatin Winter 2013.
1/16/2016The GC-in-a-PC 1 Pneumatic Focusing Gas Chromatography PFGC Robert O’Brien, Portland State Univ. & VOC Technologies The GC-in-a-PC Development.
CHROMATOGRAPHY Chromatography is used to separate and analyse small amounts of mixtures Methods involve a stationary phase and a mobile phase. There are.
Fluid Power Control.
Virtual Lab on Automation Systems A Proposal under Mechatronics Laboratory Presented By Tanuja Sheorey PDPM IIITDM Jabalpur.
BioTector COD TOC TN analyzer
The BioTector B7000i TOC analyzer with integrated oxygen concentrator
GC Trouble shooting.
Pneumatic schematic of the Dräger Infinity V500 intensive care ventilator. A. Gas-mixture and gas-metering assembly. Gas from the supply lines enters the.
Chapter 10 Systems Implementation and Operation
How do we get those numbers? Or What’s in the “Black Box”?
Diagnostics Analytical 920 LC Semi-Prep 940 LC
BOP FLUID FLUSHING SIMON McMANUS WM CANNING LTD.
Introduction to the NGC Chromatographic System
Automating the Cell Culture Sampling Process
CHROMATOGRAPHY.
AquaGlo Water Detector Kit For Detecting Water in Jet Fuel
Presentation transcript:

Mass Spectrometer Autosampler Jake Ahrens Stephen Pearson Kyle Sala Seth Yellin Project Mentor: Professor Jane Hill

Project Background Mass Spectrometer – Highly sensitive device that analyzes volatile organic compounds (VOC) Pathogen bacteria – Mass spectrometry is used to identify different pathogen bacteria Identification – Every pathogen has a specific VOC profile

Project Background Pathogen Library – Build a database of pathogen bacteria profile under various conditions. Unknown identification – Ultimately will be used to identify unknown bacteria in human lungs, by comparing the mass spectra of the humans breath, to the pathogen bacteria database

Project Motivation Currently, each sample must be connected by hand, tested, and then disconnected and cleaned. To build a large database, the sampling process needs to be automated The sampler will reduce bacterial aerosol & person contact Reduce sample contamination Increase data reproducibility

+ = ? Design an autosampler to be integrated with a mass spectrometer. This device would allow the user to hook up multiple samples, and then test them all sequentially. Problem Objective

Project Goals Maintain temperature of samples at 37°C Sample bottles need be 100ml System needs to be air tight Flow rate needs to remain constant at 2 L/min System flushing and headspace replacement Stay within $5000 budget

Method of Sampling

Before the Autosampler…

Project Progression 1.Cartesian Robot 2.Valves, Needles, and Septa Bottle Tops 3.Manually Connect Bottles to Valves 4.Incubator  Cost  Fluid Dynamics in Needles  Familiar Set-up with Current Bottles and Tops  Acquired Instead of Built an Enclosure

Our Device

Circuit Board

Major Features Valve System Microcontrollers ▫Code Incubator

Valve System 3-Way Solenoid pinch valves Used to control the path of Air and CO2

Microcontrollers 2 Independent microcontrollers Push button switches used to open all valves to replace tubing for cleaning

Valve Code Written in C Uses subroutines for each phase ▫Flushing ▫Collect CO2 and medium spectra Constants for these times defined in beginning Easy for user to change time constants depending on the tests they are running

Incubator Temperature accurate within 1% of target temp Samples need to be at constant temperature for growth and testing

2 Sample Schematic Valves

Initial Flush of Main Line

Collect CO2 Spectrum

Collect Medium Spectrum

Sample 1

Air Replacement

Flushing/Collect CO2 Spectrum

Collect Medium Spectrum

Sample 2

Sequence of Operation 1.Flush the main line with CO2 2.Collect CO2 spectrum 3.Collect medium spectrum 4.Collect sample 1 5.Replace headspace of sample 1 with air 6.Flush main line 7.Collect CO2 spectrum 8.Zero medium spectrum 9.Collect sample 2 10.Replace headspace of sample 2 with air 11.Flush main line Repeat…

Operation of device Attach sample bottles to the valve system (one inlet and one outlet per bottle) Turn on CO2 and Air supplies Turn the power switch on Save spectrum graphs for the samples

Operation Loading of sample bottles

Design Demonstration Three samples, all contain water ‘Bubbles’ depict the CO 2 flow into and out of the sample bottles Three subsequent tests ▫Testing with standard compounds that bacteria could produce in natural environment. The two we used are acetone and indole.

Test #1 Volumetric flow rate (2 L/min) Ran auto-sampler with all 9 sample bottles in place ▫Testing the code that controls the valves and subsequent gas flow Flushing and sampling sequences ▫Simulated in complete fashion Successful Test!

Test #2 Demonstration of TIC (total ion chromatograph) of sampling process Having the mass spectrometer effectively read samples from the autosampler Three sample test ▫One background control and two standard compounds ▫Water and two samples of acetone  Acetone – Commonly produced by bacteria Successful Test!

Test #2 Results Demonstration TIC (Total ion chromatograph) of sampling process of one background control and two standard compounds Step 3: Start collect sample 1 Step 5: Start collect sample 2 Step 4: CO2 flush Step 6: CO2 flush Step 1: Water background collection Step 2: CO2 flush Time (min) Intensity (%)

Mass spectrum of step 1 (signal response to bottle 1 – water) Intensity (%) Mass/charge

Mass spectrum of step 3 and 5 (signal response to bottles 2 and 3 – acetone)

Test #3 Second demonstration of TIC (total ion chromatograph) of sampling process Sampling the more volatile compound of indole in varying bottle positions ▫Indole – characteristic compound from E.Coli bacteria Able to get a momentary reading in the first bottle position and a successful reading in the last (ninth) bottle position Why is the mass spectrometer not reading this compound?

Test #3 Results Indole test at valve position 1 Short time response of Indole (peak 118) in position 1

Indole test at valve position 9 Stable response of Indole (peak 118) in position 9

Test Results Auto-sampler mechanically works and operates like it was designed too!! Effectively samples and flushes bottles Maintains volumetric flow rate (2 L/min) Able to send samples to mass spectrometer for identification But… Some compounds, as seen with indole, cannot be successfully read ▫Possible problem could be chemical interactions with the valves’ silicone tubing

Desirable Attributes Outcome Effectiveness ▫Temperature Control – Incubator (~37°C) ▫Constant CO 2 flow rate – 2 L/min ▫Automation – effectively samples nine bottles sequentially, with some user interaction Ease of Use ▫Setting up sampler – familiar process of manually connecting the tubing ▫Simplicity to operate – flipping a switch Economy ▫Cost of parts – under budget (< $5,000) ▫Replacement cheapness (cost to replace the parts that did not break because of the ones that did)– instructions from an annotated user manual, easy to replace parts

Project Outcome Sampling process automated, to build large library The sampler will reduce bacterial aerosol & person contact Reduce sample contamination Increase data reproducibility

Future Development Reduce dead space tubing for better results More samples to be taken Tube track to prevent any pinch points and allow for easier tube exchanges More chemically inert tubing Higher levels of automation ▫Computer automation

Future Development Computer automation: Develop a program to allow interface with sampler and mass spec Mass spec uses Analyst software that can communicate with other windows programs to create databases of samples

Beta

Acknowledgements Yin-Ming Kuo – Post Doctoral Fellow in The Hill Lab Jiangjiang Zhu – Ph.D student in The Hill Lab Professor Stephen Titcomb Paul Sala

Questions and Discussion