EEE 529 Microsystems Amperometric Biosensors

Slides:



Advertisements
Similar presentations
OFFLINE COMPOSITION MEASURING SENSORS
Advertisements

Fig. 22-1a (p.629) A galvanic electrochemical cell at open circuit
A galvanic cell is made from two half cells. In the first, a platinum electrode is immersed in a solution at pH = 2.00 that is M in both MnO 4 -
PH 0101 Unit-5 Lecture-61 Introduction A fuel cell configuration Types of fuel cell Principle, construction and working Advantage, disadvantage and application.
Summary of Potentiometry:
Experiment #10 Electrochemical Cell.
Electrode measuring principle
Electricity from Chemical Reactions
MLAB 2401: C LINICAL C HEMISTRY K ERI B ROPHY -M ARTINEZ Designs in Instrumentation Electrochemistry.
Unit 11- Redox and Electrochemistry
3-D reconstructions based on electron micrographs of isolated mitochondria taken with a large depth of field, at different tilt angles have indicated.
Oxidation Reduction Reactions
Standard Reference Electrode Standard Hydrogen Electrode (SHE) SHE: Assigned V Can be anode or cathode Pt does not take part in reaction Difficult.
PH pH is a unit of measure which describes the degree of acidity or alkalinity (basic) of a solution. It is measured on a scale of 0 to 14. The formal.
ELECTROCHEMISTRY Chapter 17. W HAT IS ELECTROCHEMISTRY Electrochemistry is the science that unites electricity and chemistry. It is the study of the transfer.
Chem. 133 – 3/5 Lecture. Announcements Lab –Set 2 Period 2 Labs Set to Finish 3/10 –3/12 will be make up day (for both Period 1 and Period 2 labs) –Set.
Dr. Marc Madou, UCI, Winter 2012 Class V Potentiometric and Amperometric Sensors (I) Electrochemistry MAE-295.
Oxidation Reduction Chemisty: Redox Chemistry
Amperometric Biosensors. Introduction Enzyme Catalyzed redox reactions The function of the enzyme is to generate or consume an electroactive species in.
Nanobiosensors Sara Huefner November 6, Outline Biosensor Background –What is a Biosensor? –Components of a Biosensor –Principles of Detection Biosensors.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 15 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Electroanalytical Chemistry
Electrochemical Thermodynamics and Concepts Sensitivity of electrochemical measurements Measurements of electrochemical processes are made by measuring.
Fundamentals of Electrochemistry Introduction 1.)Electrical Measurements of Chemical Processes  Redox Reaction involves transfer of electrons from one.
POTENTIOMETRY 8th lecture
Zn  Zn2+ + 2e- (oxidation) Cu e-  Cu (reduction)
1. Voltammetry AIT.
Electrochemistry Chapter 4.4 and Chapter 20. Electrochemical Reactions In electrochemical reactions, electrons are transferred from one species to another.
Aim Redox 1 – Why is redox so important in your life?
Summer Course on Exergy and Its Applications EXERGY ANALYSIS of FUEL CELLS C. Ozgur Colpan July 2-4, 2012 Osmaniye Korkut Ata Üniversitesi.
Fundamentals of Electrochemistry Introduction 1.)Electrical Measurements of Chemical Processes  Redox Reaction involves transfer of electrons from one.
Chapter 22 REDOX.
Ch. 2 CHEMISTRY. Matter: has mass and takes up space Mass: quantity of matter an object has.
Coulometric Methods A.) Introduction:
Life depends on chemistry –all living things are made from chemical compounds which are used in chemical reactions to keep organisms alive ELEMENT – made.
1. Blood or Fluid Analysis Using carried out in central labs with problems of time delay costs and potential misslabeling Drive toward more bedside or.
CHEM 163 Chapter 21 Spring minute review What is a redox reaction? 2.
6/2/20161 CHAPTER 2 CORROSION PRINCIPLES Chapter Outlines 2.1 Oxidation and Reduction Reactions 2.2 Standard Electrode Half- Cell Potentials 2.3 Standard.
Oxidation and Reduction Lecture 9. Law of Mass Action Important to remember our equation describes the equilibrium condition. At non-equilibrium conditions.
Polarization.
CHAPTER 11 ELEMENTS OF ELECTROCHEMISTRY Introduction to Analytical Chemistry.
Chapter 17 Corrosion and Degradation of Materials.
PTT 202 ORGANIC CHEMISTRY FOR BIOTECHNOLOGY Lecture 4: Electroanalytical Methods Zulkarnain Mohamed Idris Semester /2014.
A.) Introduction : 1.) Coulometry: electrochemical method based on the quantitative oxidation or reduction of analyte - measure amount of analyte by measuring.
Section 13 Analytical Voltammetry.
Electricity from chemical reactions Galvanic Cells Chapter 14.
Electrodes and Potentiometry Introduction 1.)Potentiometry  Use of Electrodes to Measure Voltages that Provide Chemical Information - Various electrodes.
Electrochemistry. What is “electrochemistry”? The area of chemistry concerned with the interconversion of chemical and electrical energy. Energy released.
Commercial Use of Enzymes
Chemistry of Life Matter-anything that occupies space and has mass Mass -quantity of matter an object has Weight -force produced by gravity acting on mass.
Chem. 133 – 3/3 Lecture. Announcements Homework Set 2 (pass out) Grading –Working to get the Electronics labs and exam 1 graded by next Tuesday Lab –today.
Ch. 21 Potentiometry 1. General principles
Chapter 6 Biology The Chemistry of Life. 6.1 Elements Elements are substances that can’t be broken down into simpler substances Elements are substances.
In the name of GOD.
Composition of Matter Section 1. Matter and Mass Matter - anything that occupies space and has mass Mass – quantity of matter an object has – Mass is.
Introduction to Biomedical Sensors BME 301 Biomedical Sensors Lecture Note 1 BME 301 Biomedical Sensors - Ali Işın 2014.
Electrochemistry MAE-212
Biosensors Definition
Basic Chemistry, Electrochemistry & Corrosion Theory
Basic Corrosion Theory
Objectives Understand how a fuel cell makes electricity
Rapid Lab Systems measuring principle
PH pH is a unit of measure which describes the degree of acidity or alkalinity (basic) of a solution. It is measured on a scale of 0 to 14. The formal.
Basic Corrosion Theory
Fundamentals of Electrochemistry
Instructions: Glue in your warm-up sheet on the back of your Characteristics of Life foldable page Answer the Characteristics of Life warm-up (1st box.
Electrochemistry Lesson 3
18.2 Balancing Oxidation-Reduction Equations
Presentation transcript:

EEE 529 Microsystems Amperometric Biosensors Agamyrat Agambayev 520112003

Contents: Introduction to Biosensors Definitions Amperometric Biosensors Generations of Amperometric Biosensors Performance factors Applications References

MULTIDISCIPLINARY NATURE OF BIOSENSOR:

INTRODUCTION BIOSENSORS : Compact analytical devices that bring together the use of a biological, a biologically-derived or a biomimic element to recognize the analyte.

INTRODUCTION Biosensor = biorecognation element + transducer. a biomolecule that recognizes the target analyte Transducer converts the recognition event into a measurable signal The uniqueness of a biosensor is that the two components are integrated into one single sensor 

INTRODUCTION Biosensor = biorecognation element + transducer. 

Biosensor = biorecognation element + transducer. Transducer. A transducer should be capable of converting the biorecognition event into a measurable signal . Typically, this is done by measuring the change that occur in the bioreceptor reaction. For example, the enzyme glucose oxidase (used as a bioreceptor in a glucose biosensor) catalyzes the following reaction: Glucose + O2 --------> Gluconic acid + H2O2

An oxygen sensor that measures oxygen concentration  To measure the glucose concentration, 3 different transducers can be used: An oxygen sensor that measures oxygen concentration A pH sensor that measures the acid (gluconic acid) production A peroxide sensor that measures H2O2 concentration. Note: An oxygen sensor is a transducer that converts oxygen concentration into electrical current. A pH sensor is a transducer that converts pH change into voltage change. A peroxidase sensor is a transducer that converts peroxidase concentration into an electrical current.

The choice of the biological recognition element is the crucial decision that is taken when developing a novel biosensor design. It is important to define criteria for, for example, a suitable redox enzyme for a specific biosensor. Most importantly, the enzyme needs to selectively react with the analyte of interest. The redox potential of the primary redox center needs to be within a suitable potential window (usually between − 0.6 and 0.9 V vs. Ag/AgCl). The enzyme needs to be stable under the operation and storage conditions of the biosensor and should provide a reasonable long - term stability.

Advantages and Disadvantages of using Enzymes in sensors Highly selective Catalytically active improve sensitivity Fairly fast-acting One of the most known biological components Expensive A loss activity when immobilized on a transducer Tending to lose activity after a relatively short period time

Considerations for biosensor development Selection of a suitable biorecognation molecule Selection of a suitable immobilization method Selection of a suitable transducer Designing of biosensor considering measurement range, linearity, and minimization of interference Packaging of biosensor

Biosensors are classified according to the parameter that is measured by the physicochemical transducer of the biological event as: Optical, Electrochemical ---- > Amperometric Acoustic, Thermal. Amperometric Biosensors: the oldest ones, which have led to the higher number of ready to- use devices, are based on the monitoring of electron-transfer processes

Redox (reduction-oxidation) reactions include all chemical reactions in which atoms have their oxidation state changed. 

Amperometric Biosensors produce a current proportional to the concentration of the substance to be detected. The most common amperometric biosensors use the Clark Oxygen electrode. In the glucose Amperometric Biosensor, the Clark Oxygen electrode is separated from glucose by a membrane, that is permeable to oxygen. A biocatalyst Glucose Oxidase(GOD) is housed between this membrane and another membrane that separates it from the glucose. This membrane that separates GOD and glucose is permeable to both Oxygen and Glucose.

In effect, the enzyme GOD is immobilized between two membranes, the top being permeable only to oxygen and the bottom to both Oxygen and Glucose. The Glucose that enters the membrane is Oxidised in presence of the enzyme GOD, to produce Glucuronic acid and Hydrogen Peroxide. glucose + O2 – >  glucuronic acid + H2O2 Hence the concentration of oxygen decreases as it moves up through the membranes to reach the cathode. This decrease in Oxygen concentration is reflected as a decrease in current between the electrodes.

Alternatively, the decrease in the concentration of Hydrogen Peroxide can also be used to find the concentration of glucose, by changing the voltage applied between the electrodes to +0.68 V relative to the Ag/AgCl electrode causing the reactions: Pt anode     H2O2 -- > O2 + 2H+ + 2e- Ag cathode     2AgCl + 2e- -- > 2Ag0 + 2Cl-

Principle of Amperometry (Polarography) Polarogram. When an electrode of noble metal such as platinum or gold is made 0.6 to 0.8 V negative with respect to a suitable reference electrode such as Ag/AgCl or an calomel electrode in a neutral KCl solutionhe oxygen dissolved in the liquid is reduce at the surface of the noble metal. This phenomenon can be observed from a current-voltage diagram - called a polarogram - of the electrode

Principle of Amperometry (Polarography) As shown in Fig. 2.2a, the negative voltage applied to the noble metal electrode (called the cathode) is increased, the current increases initially but soon it becomes saturated. In this plateau region of the polarogram, the reaction of oxygen at the cathode is so fast that the rate of reaction is limited by the diffusion of oxygen to the cathode surface

Principle of Amperometry (Polarography) When the negative bias voltage is further increased, the current output of the electrode increases rapidly due to other reactions, mainly, the reduction of water to hydrogen. If a fixed voltage in the plateau region (for example, - 0.6V) is applied to the cathode, the current output of the electrode can be linearly calibrated to the dissolved oxygen (Fig. 2.2b). It has to be noted that the current is proportional not to the actual concentration but to the activity or equivalent partial pressure of dissolved oxygen, which is often referred to as oxygen tension. A fixed voltage between -0.6 and -0.8 V is usually selected as the polarization voltage when using Ag/AgCl as the reference electrode.

DO Sensor. When the cathode, the reference electrode , and the electrolyte are separated from the measurement medium by a polymer membrane, which is permeable to the dissolved gas but not to most of the ions and other species, and when most of the mass transfer resistance is confined in the membrane, the electrode system can measure oxygen tension in various liquids. This is the basic operating principle of the membrane covered polarographic DO probe (Fig 2.3).

Signal Conditioning.  To read the output from the sensor, the current from the sensor is first converted to voltage by the circuit shown in Fig (the first 1/2 of an operational amplifier LF412). This circuit has a gain of 10,000,000: Therefore, 0.1 micro ampere sensor current will produce an output of - 1V at pin 1 of LF412 (note that R1 can be changed to obtain other amplifier gains). The next stage is an inverting amplifier with gain. The output from this stage is: where R2 is the resistance in the feedback loop which can be adjusted. The application of the polarization voltage is done by a 79L05 voltage regulator that converts its input voltage of -12V to -5V. At the output of 79L05, a voltage divider (R3) is used to convert -5V to -0.7V, which is then applied to the + input of LF412. The voltage output V2 can be read either by a voltmeter or by a computer equipped with an analog-to-digital converter.

Electrode Reactions. For polarographic electrodes, the reaction proceeds as follows: Cathodic reaction:: O2 + 2H2O + 2e- --> H2O2 + 2OH- H2O2 + 2e- -->2OH- Anodic reaction:: Ag + Cl- --> AgCl + e- Overall reaction:: 4 Ag + O2 + 2H2O + 4 Cl- --> 4 AgCl + 4 OH- the reaction tends to produce alkalinity in the medium together with a small amount of hydrogen peroxide.

Number of Electrons Involved Number of Electrons Involved. Two principal pathways was proposed for the reduction of oxygen at the noble metal surface. One is a 4 electron pathway where the oxygen in the bulk diffuses to the surface of the cathode and is converted to H2O via H2O2 (path a in Fig. 2.5). The other is a 2 electron pathway where the intermediate H2O2 diffuses directly out of the cathode surface into the bulk liquid (path b in Fig. 2.5). The oxygen reduction path may change depending on the surface condition of the noble metal. This is probably the cause for time-dependent current drift of polarographic sensors. Since the hydroxyl ions are constantly being substituted for chloride ions as the reaction starts, KCl or NaCl has to be used as the electrolyte. When the electrolyte is depleted of Cl-, it has to be replenished.

1st generation: the normal product of the reaction diffuses to the transducer and causes electrical response

1st generation: the normal product of the reaction diffuses to the transducer and causes electrical response

1st generation: the normal product of the reaction diffuses to the transducer and causes electrical response

1st generation: the normal product of the reaction diffuses to the transducer and causes electrical response

2nd generation: involves specific mediators between reaction and transducer to generate improved response

2nd generation: involves specific mediators between reaction and transducer to generate improved response

2nd generation: involves specific mediators between reaction and transducer to generate improved response

2nd generation: involves specific mediators between reaction and transducer to generate improved response

2nd generation: involves specific mediators between reaction and transducer to generate improved response

2nd generation: involves specific mediators between reaction and transducer to generate improved response

3rd generation: reaction itself causes the response

3rd generation: reaction itself causes the response

AMPEROMETRIC BIOSENSORS Substrate Bioreceptor Product detected Range, mM choline choline oxidase H2O2 500 ethanol alcohol oxidase 0 - 10 formaldehyde f. dehydrogenase NADH 10-3 glucose glucose oxidase H2O2, O2 0-7 g/L glutamine glutamine oxidase 0-25 glycerol g. dehydrogenase NADH, O2 hypoxanthine x. oxidase 4-180 lactate lactate oxidase 1-40 oligosaccharides glucoamylase, glucose oxidase 0.1-2.5 phenol polyphenol oxidase quinone

PERFORMANCE FACTORS Selectivity Sensitivity Accuracy Response time Recovery time Lifetime

PERFORMANCE FACTORS

References A.G. Elie,Principles of Potentiometric and Amperometric Biosensors,University of Virginia,(2002) P.V. Climent, M.L.M.Serralheiro, and M.J.F. Rebelo, Pure and Applied Chemistry 73, pp.1993-1999, 2001 http://www.lsbu.ac.uk.html http://www.gatewaycoalition.org/files/Hidden/sensr/tocsenf.htm http://techramble.wordpress.com/2009/08/03/amperometric-biosensors/ http://www.lbb.ethz.ch/Education/Biosensors/2011FSlesson4TZ

Thank You