Cleaner water – Greener environment

Slides:



Advertisements
Similar presentations
Advanced Wastewater Treatment Plants.
Advertisements

Contents: Cover
Australian water filter.
Newcastle Water Pollution Control Plant
AEC advanced environmental control aps
Internationally renowned for localised service High efficient, economic and flexible Waste Water Treatment with Biofiltration 3 rd Generation.
1 Seair Diffusion Systems Inc. Pulp & Paper Solutions June 2009.
INTRODUCTION TO THE TREATMENT OF TANNERY EFFLUENTS
Sewage and Effluent Treatment 2-4 November 2002 Seán Moran -The first few slides.
Salsnes Filter Overview
Treatment of Slaughterhouse Wastewater
Soneva Gili Resort Comments on existing STP 27. August 2008.
An-Najah National University Civil Engineering Department
Techniques in post treatment of ABR effluents in treating municipal wastewater A literature review of appropriate technologies for Nepal Sanita Dhaubanjar’13.
GENERATION OF ADDITIONAL REVENUE FROM PRODUCTS OF
Membrane Processes For Waste Water Treatment By: Rohit Chaurasia 3 rd B. Tech. Civil Engineering 71/08.
Trickling Filters and Rotary Biological Contactors
Intel Water Reclaim Project Final Report 5/25/05.
The AFC Process What Is AFC? Key Operations are  Balancing of incoming waste streams  Thermophilic activated sludge (AFC) to oxidise the organic.
Upgrade of Sana'a WWTP1 Upgrade of the Sana‘a Wastewater Treatment Plant Presentation of the Design Implementation of the New Preliminary Wastewater.
© 2006, Koch Membrane Systems, Inc. All rights reserved. MBR Technology for Water Reuse in Municipal & Industrial Applications Christoph Kullmann Business.
The Quality Company - Worldwide SOUTH WEST WASTE MINIMISATION GROUP 3 RD JUNE 2009.
Antunes Water Filtration Technologies Introduces to You:
I-MBR Side-stream, in vitro MBR system for Water Treatment About i-MBR Modules PHILOSEP i-MBR is in vitro, cased and decompression type membrane modules.
Process biotechnology application to industrial wastewater treatment plants PROF AVN SWAMY, Vice Principal, JNTUACE Pulivendula.
By Shantanu Mane Vaidehi Dharkar Viral Shah
OZONE DRINKING WATER SYSTEM. CONTENTS Properties of Ozone Production of Ozone Water Treatment Plant – 25 m 3 /hr Ozone Generation System.
Siemens sans siemens sans bold siemens sans italic siemens sans italic bold siemens sans black siemens black italic Siemens Building Technologies.
Tel: +44 (0) Turbidity Application and Product Data.
Increasing Energy Efficiency at the Allegan WWTP MWEA/AWWA Joint Annual Conference August 19, 2010.
Phosphorus Removal in a Membrane Reactor System— A Demonstration Study Wayne Lorenz, P.E. and Matthew J. Gavin Wright Water Engineers, Inc. and Newell.
Volvo Group North America, LLC Reuse of Wastewater - A Manufacturer’s Experience Steve Pierett, Env.Mgr. CEM, CRM, CP EnMS-Industrial.
Reverse Osmosis Ultrafiltration Microfiltration
SCI-Pak Sustainable and Cleaner production in the manufacturing industries of Pakistan FUNDED BY THE EUROPEAN COMMISSION 1 SCI-Pak Sustainable.
Automatic and energy efficient dewatering unit for waste water treatment: SAV Ulf Johansson, Stigebrandt Hydroteknik AB, Sweden.
High Rate Thermophilic Anaerobic Membrane Bioreactor for Wastewater Treatment by Kaushalya C. Wijekoon Master Student (st107821) EEM/SERD Wastewater Ξ.
SEWAGE TREATMENT.  Sewage is the mainly liquid waste containing some solids produced by humans, typically consisting of washing water, urine, feces,
Human Waste Disposal  More than 500 pathogenic bacteria, viruses, and parasites can travel from human or animal excrement through water.  Natural Processes.
Supplier Event Innovation Steve Kaye – Manager of Innovation Anglian Water.
Practical period in Windhoek
Smartcool Systems Inc. Providing effective and reliable energy efficiency solutions for HVAC-R customers around the globe.
Network Appurtenances Major operations within a water transport and distribution systems are: 1. Transmission. 2. Storage. 3. Pumping.
Deborah Helstrom, P.E. Industrial Permits Team Wastewater Permitting Section Membrane Bioreactors Treatment.
MEMBRANE BIOREACTORS AS - MBR Vs MBBR - UF EEC GLOBAL OPERATION By: C.S. Umre Technical Director.
Environmental Engineering (Wastewater treatment) Core Course Laboratory of Environmental Engineering & Planning Department of Civil Engineering Aristotle.
APC-MB05 IS ADVANCED IN WASTEWATER TREATMENT SYSTEMS APC Wastewater Treatment System.
Components of Water Networks Eng. Mona Al-Gharbawi Eng. Ayman Al-Afifi
KHWAHISH Water Solutions.
Compressed Air System Optimization Rebate
Membrane Bioreactors for Wastewater Treatment.
Energy Efficiency and Competitiveness with Advanced Wastewater Treatment How a wastewater treatment plant can be more efficient and achieve better results?
WATER MANAGEMENT.
Sludge water recycling unit UFOX 10
Pulp and Paper Mill Waste Water Decolouration with Ozone Brendan van Wyk, Alexis Metais, Jens Gebhardt, Narain Madhaven.
Mintie Technologies, Inc. ECU Product Introduction and Demo/Training Virginia Presentation.
GPAEE New Technologies Blitz 960 Brook Road, Unit 3, Conshohocken, PA * Phone: (610) * Fax: (610) * Feb 18, 2016.
I-RACH range I-RACH range I-RACH range I-RACH range High efficiency air/water heat pump with INVERTER scroll compressor Range Modularity Components Highlights.
Rastlinske čistilne naprave
5th Annual Water and Sanitation Workshop
Advanced Technologies Decentralized Recovery and Reuse
Containerized desalination based on RO:
Engineered Water Treatment Solutions
Self Aspirating Turbine Aerator for all kind of liquid
Pilot testing services and a case study to reduce organics Devendra Borikar, Laura Zettler, Jeff Avedesian, Lindsay Ariss, Luc Léonard, Denis Dolbec,
Methods for Wastewater and Sludge Treatment
City of Delphos Waste Water Treatment Plant
Improving Energy Reliability & Performance
Improving Energy Reliability & Performance
Laboratory Animal Professionals Control the Outcome
The Application of Membrane Technologies in Wastewater Re-use
Presentation transcript:

Cleaner water – Greener environment GRUNDFOS BIOBOOSTER GBB YWPDK | March 2015 | Anne Barslund Click to edit Master text styles

Trend in Danmark Centralized waste water treatment Pumping water long distance Transport system with a payback time at 75 years Bound for investment for 75 years -> How is the situation in Denmark in 2090? Example where they want to centralize a city with 240 PE 15,6 kilometers away. It require a new transport system and a large investment. Decentralized waste water treatment Require a robust treatment plant Outlet at least as clean as central waste water treatment plant Low need for man power

Why Grundfos BioBooster ? Growing population and increasing stress on natural resources Increasing demand for environmental protection & sustainable use/re-use of water Growing need for decentralized solutions Robustness/ease of operation, better treatment performance and competitive life cycle cost will be required

Focus segments Municipal segment Hospital segment Industrial segment Complete municipal plants for 1000 – 10000 PE greenfield and upgrade projects Complete plants for resorts, hotels, golf courses etc. 100 - 2500 m3/day. Hospital segment Complete plants for removing pharmaceuticals for hospitals with 300 – 2000 beds Industrial segment Plants to F&B IKA’s (Arla, CocaCola, Pepsico, Nestle, Unilever, Carsberg etc.) from 100 – 2000 m3/day.

Grundfos Wastewater treatment plant concept 2. Process tanks Skids for integration into existing building/basement in a new building a climate shield 4. Optional Ozone + GAC post treatment for hospitals 5. Optional Sludge drying to 90% dry matter for larger plants 3. Ceramic membrane filtration Good service access for operation and maintenance chemcial exchange by-product removal 6. Optional air treatment/closed tanks for odour/patogen removal in residential areas 1. Mechanical pre-treatment

Grundfos Membrane Filtration Unit (MFU) Ceramic membrane discs with an effective membrane area of 34 m2 per MFU. Ultrafiltration 200 nm pore size for bacteria free effluent Safe and reliable fouling elimination based on unique rotating filter discs Enables MLSS: 3-30 g/m3 operating interval. Enables more biological processes in one tank (aerobic, anaerobic, anoxic) (as no air used) Each filter unit has a peak capacity of 65 m3/day and annual average of 32 m3/day. No need for membrane replacement - discs can be reburned. Permeate 0-2 bar TMP control Process tank 3 – 30 kg MLSS/m3 Sludge 4-6% DM 2-4 x Recirculationsflow

MFU performance Peak flux test (6 weeks from Monday to Friday) Flux 40 during weekends and receiving 1 x CEB 86 lmh has been demonstrated on 6°C cold wastewater in Norway.

Grundfos MFU skid 8 Membrane Filtration Units per 1 MFU skid Dimensions 1,1 m x 11,5 m x 2,5 m skid Key features of GRUNDFOS MFU skid Peak capacity up to 518 m3/day over 5 days per MFU skid Automatic fine-grained flow capacity adjustment for optimum energy consumption by using MFU idling function. Integrated sludge de-watering functionality up to 4-6% dry matter Online leakage control and auto shut-off of each single MFU Fully automated operation of MFU skid incl. recovery cleanings Competitive life cycle cost when compared with other membrane systems for 1000 – 10000 PE plants

ODIN optimizer Operator inDependent intellIgent operatioN Example from testplant Rapid flux drop – ODIN automatically reacts by: Increasing the TMP Shortening the cycle (17 min  8 min) Increasing RPM (100 RPM  130 RPM) ODIN Sludge Quality module registered the change in sludge properties! Recovery: - Cycles get longer - TMP stabilizes - RPM drops

MFU energy optimization by ODIN Manual trim of parameters (TMP, RPM, backwash interval, time and pressure) Automatic adjustment of all parameters using ODIN algorithm

Automatic fouling estimation/CEB Case Hemsedal

Grundfos BioBooster WWTP concept Key features Industrialized and modular built-up concept provides a high quality product with a short project execution time and limited onsite works. Skids allows for integration into building, or climate shield directly on skids Robust design and highly automated operation ensures low operator and service requirements Concept suits Design, Build and Turnkey type of contracting and brings low risc and savings to the employer.

More on why BioBooster Consider a decentralized Grundfos BioBooster MBR systems: Environmental drivers to maintain an aquatic life in smaller local water streams to ensure compliance with stricter effluent requirements – (P <1 and N <8 mg/litre) to protect receiving waters for recreational purposes (bathing and fishing eg.) against bacteria when the effluent is reclaimed for re-use in golf courses, agriculture and the like. to prevent antibiotic resistant bacteria and micropollutants from entering the environment and to make the plant future-proof. Technical drivers when loadings are seasonal fluctuating, eg. due to tourism when cold weather conditions are normally too cold for nitrification when the plant needs to be prepared for future increased load rates. when operations needs to be highly automated and require minimum staff attention when space is limited or the the plant is close to odour sensitive neighbours

References Click to edit Master text styles

Municipal application Bjerringbro Wastewater Works, Denmark Full scale test site for membrane technology and biological processes . GBB test confirms : Flux: 40/80 l/m2h Power 0,6 kwh/m3 Easy to operate Operational since spring 2012 Municipal application

Municipal application Ulsåk Wastewater Plant Hemsedal, Norway Upgrade to secondary treatment 17 m3/h UF filter capacity. 2000 PE biological capacity COD outlet < 30 mg/l P-tot outlet < 0,3 mg/l Handed over to Customer Feb. 2013 after trial/rebuild period 2 skids with Membrane Filter Units: Municipal application

Industrial application Arla Foods, Vimmerby, Sweden Full mechanical and biological treatment of dairy wastewater. Capacity: 400 m3/d CODtot mg/L 3200 in - 30 out Ntot mg/L 300 in - <5 out Ptot mg/L 25 in - 0,35 out Order November 2012 Delivery 11 March 2013 Start operation 23 April 2013 Handover to customer June 2013

Hospital application Herlev Hospital Denmark Private-Public Innovation project First project in Denmark developing decentralized technologies for removal of micro pollutants from hospitals wastewater. Capacity: 900 beds, 560 m3/d Commissioned May 2014 COD 10 mg/l N-tot 2-6 mg/l P-tot 2 mg/l (just Bio-P)

Thank you for your attention Click to edit Master text styles