OhioLumex Co. RA915+ Mercury Joseph Siperstein 1-888-876-2611 www.OhioLumex.com Mercury Spill Response Workshop Lansing, Michigan.

Slides:



Advertisements
Similar presentations
Solid and Hazardous Waste
Advertisements

Radiochemical Methods and Data Evaluation
Brian DeGennaro Physical Properties- Molecular Weight: Chemical Formula: Hg Atomic Number: 80 Appearance: Silver-white, heavy, mobile, liquid metal.
Ronald L. Baker Robert Peters Edul Chikhliwala EcoChem Analytics
Simplifying Hg Ohio Lumex 915 J Mercury Process Monitor.
Further Site Investigation Sutton Walls Former Landfill
Although this monitor is owned and operated by the State of Missouri, significant research was conducted with this technology for fence-line monitoring.
ATOMIC ABSORPTION SPECTROMETER
I n t e g r i t y - S e r v i c e - E x c e l l e n c e Headquarters U.S. Air Force 1 Direct Sampling Ion Trap Mass Spectrometry Rob R. Smith Oak Ridge.
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
Lumex is a manufacturer of analytical and scientific instrumentation
Mercury Monitoring The FDEP Laboratory Perspective Timothy W. Fitzpatrick (850)
Conversion Factors Different ways to express length
Coal to Coke at the Avenue. The Avenue Coke Works Processed coal to produce coke Coke used as a smokeless fuel and in the steel-making industry Wastes.
.
1 VACUUM ATMOSPHERES Co NEW PRODUCT ANNOUNCEMENT November 28, 2001.
.
Characteristics of Asian Pollution at Mt. Bachelor Observatory during Spring 2004 Peter Weiss-Penzias UWB Data Workshop, Oct. 14, 2004.
Pollution Prevention for Light Industry and the Service Industry P2 Ideas for Urban Environments.
IR – Infrared Spectroscopy. What is IR Spectroscopy? Infrared spectroscopy is the analysis of infrared light interacting with a molecule. IR spectroscopy.
Total X-ray Fluorescence Spectroscopy (TXRF) Contact: World Agroforestry Centre (ICRAF), P.O. Box Nairobi, Kenya. Tel:
COMPANY PRESENTATION TO: MONTH XX, Agenda Who we are Our experience Benefits of measuring with light The Prozess Technologie solution Identify YOUR.
Long-Term Remote Water Quality Sensor System For more information, contact the ENERGY lab Dustin L.
Field Methods of Monitoring Atmospheric Systems Chemical Analysis of Particulate Matter Copyright © 2006 by DBS.
Assement of radionuclide concentration in various samples by gamma spectrometry and LSC J. Berzins, D.Riekstina, O. Veveris Institute of Solid State Physics.
Industrial Air Quality Monitoring. Sampling Protocols Grab vs. Integrated Personal vs. Area.
Monitoring Station Location and Siting Initially on a residential porch at Marina Towers, aligned with the Mirant Potomac River Generating Station (PRGS)
2537A Tekran Mercury Analyzer
WLTP-DTP-AP Validation of N 2 O measurement WLTP-DTP-AP Subgroup Additional Pollutants Validation of N 2 O measurement.
PORTABLE HIGH-SPEED GAS CHROMATOGRAPH
An Autonomous Inexpensive Robust CO 2 Analyzer (AIRCOA) Britton Stephens, Andrew Watt, and Gordon Maclean National Center for Atmospheric Research, Boulder,
Welcome Acklands-Grainger April 16, Technology Applications Advantage: VX500.
2007 Measurement Technology Workshop September 11, 2007 EPA Update on the Development of Alternative Reference Methods for Mercury and Testing Equipment.
Navi Rutgers University 2012 Design Presentation
Akshaya Jena and Krishna Gupta Porous Materials, Inc. NY, USA Fuel Cells R&D Enhancing Performance through Pore Structure.
Mercury Spill Response Instrumentation. Mercury Vapor Analyzers Jerome 431-X MVA (gold film) Lumex 915+ MVA (Atomic Absorption) Jerome J405 MVA.
Continuous Particulate Monitoring Using Light Scatter Photometers.
1 Saxony-Anhalt EU Twinning RO 04/IB/EN/09 State Environmental Protection Agency Wolfgang GarcheWorkshop European Standards Requirements of.
Solid and Hazardous Waste Chapter 21 “Solid wastes are only raw materials we’re too stupid to use.” Arthur C. Clarke.
Field Analytical Methods. Considerations for Field Analytical Methods Which parameters are anticipated to occur at the site? What media will be analyzed?
Lecture 1 – What is Analytical Chemistry? & What is the Analytical Method?
Field Methods of Monitoring Atmospheric Systems Remote Sensing Copyright © 2006 by DBS.
Ultra-trace Mercury Monitoring in Air. Company History Founded in 1989 to develop custom instrumentation for environmental analysis Founded in 1989 to.
1 / 9 When things get rough you need new stuff William Lipps Analytical & Measuring Instrument Division July, 2015.
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
Measurement of Acrylonitrile in Ambient Air AMTAC April 12, 2011 John Bricarello California Air Resources Board.
Malé Declaration Joint Training on Regional Refresher Course and Soil Acidification Asian Institute of Technology (AIT), Bangkok, Thailand from
© 2006 MSA VaporLab™ 700 Gas Analyzer. © 2006 MSA Product Description  Rack mount, turn-key gas analyzer  Analyzes a complex matrix for trace quantities.
LUMEX ANALYTICAL EQUIPMENT Head office: , Saint-Petersburg, Moskovsky pr. 19 Tel: (812) , (812) Fax: 812) , (812)
William Telliard U.S. EPA Office of Science and Technology
TRL-TOC CONFIGURATIONS JUNE 2014, ANKARA Bülent ATAMER.
RIGHT SOLUTIONS | RIGHT PARTNER HRMS Centre of Excellence Brief introduction of the HRMS laboratory.
High-resolution spectroscopy and light source technology laboratory Institute of Atomic Physics and Spectroscopy University of Latvia, Riga Presentation.
SPECTRAL PRODUCTS INTRODUCTION 111 Highland Drive, Putnam, CT 06260, USA (East Office) 2659A Pan American Freeway NE, Albuquerque, NM 87107, USA (West.
Prof. Jiakuan Yang Huazhong University of Science and Technology Air Pollution Control Engineering.
Evaluating the Use of Many Low-Cost Sensors for Monitoring NO 2 Gradients Presented by Timothy S. Dye, David L. Vaughn, Alison E. Ray, and Paul T. Roberts.
Vapor Study Informational Meeting General Mills/Henkel Corp. Superfund Site Van Cleve Recreation Center November 12, 2013 Minnesota Department of Health.
Ambient air sampling and monitoring Topic 5 Ms. Sherina Kamal.
The world leader in serving science For Research Use Only. Not for use in diagnostic procedures Quantitative Analysis of 4 Immunosuppressant Drugs in Whole.
Motivation Chemiluminescence Method Heteropoly Blue Results Due to the harmful health effects of respirable crystaline silica, the National Institute of.
Green Power Tools: Assessment Tools to Support Green Remediation Goals April 5,
Laboratory Decommissioning : Essential Tools and Lessons Learned Jim Carscadden Division of Environmental Protection Office of Research Facilities.
 FT-IR stands for Fourier Transform Infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR radiation is passed through.
Energy measuring Instruments
PORTABLE HIGH-SPEED GAS CHROMATOGRAPH
The Analysis of Soils and Waters in Accordance with U. S
30 miles in 1 hour 30 mph 30 miles per hour
Calibration in the Ambient Air Quality Monitoring Network
Long-Term Remote Water Quality Sensor System
Environmental Catalogue Introduction
Presentation transcript:

OhioLumex Co. RA915+ Mercury Joseph Siperstein Mercury Spill Response Workshop Lansing, Michigan

MERCURY DETERMINATION mercury content in ambient air, detecting mercury spills mercury determination in aqueous samples, EPA method 1631 direct (no digestion) analysis of soil,complex matrixes, EPA method 7473 mercury monitoring for indoor air (‘Instant’ NIOSH 6009 results) mercury determination in natural gas or industrial emmisions monitoring FIELD or LABORATORY APPLICATIONS with RA Air – 2 ng/m 3 range mg/m 3 liquids – 0.5 ng/l solids – 0.5 µg/kg background correction Zeeman effect with HF polarization modulation size and weight 460x210x110 mm; 7.5 kg power supply 220/110 Vac, 50/60 Hz; 10/14 Vdc RP91 RP91C RA 915+or “Light”

DIRECT MERCURY DETERMINATION IN THE FIELD MERCURY DETERMINATION with RA Gas production site Landfill siteSpill ANALYTICAL INSTRUMENTATION

MERCURY DETERMINATION FIELD LABORATORY Insertion of a sample in the instrument. Analysis time 1 minute. No autosampler required. Throughput up to 30samples per hour.

MERCURY DETERMINATION with RA ANALYTICAL INSTRUMENTATION MERCURY DETERMINATION with RA Multifunctional mercury spectrometer Due to the low power consumption (15 W) and low weight (16 Lb. with built-in batteries) the spectrometer can be used for mercury determination in air and natural gas, samples of soils, rocks, water in laboratory as well as in field conditions. FIELD MERCURY VAPOR “SNIFFER” FIELD MERCURY VAPOR “SNIFFER”

ANALYTICAL INSTRUMENTATION MERCURY DETERMINATION with RA Real Time mercury Spectrometer with Zeeman correction for interferences. 2. Lowest Detection Limit, 2ng/M 3 3. Real time measurements with MS Windows dataloging. 4. Wide measurement range, mg/M 3 5. Field performance verification cell 6. Simple to operate 7. Low maintenance with 48 hours repair/replacement policy

ANALYTICAL INSTRUMENTATION MERCURY DETERMINATION with RA No Effect of interfering gases Gases in (high) concentration have no interfering effect exceeding 100 ng/m3 or mg/m3.

ANALYTICAL INSTRUMENTATION MERCURY DISTRIBUTION IN AIR MERCURY DETERMINATION Mercury distribution along the profile crossing the area of an unidentified ore mine and a smelter. M –mine C – central part of mine S – smelter W – waste dump Figure shows the results of mercury determination along the profile of a mine, smelter and a waste dump. The RA analyzer was placed in a car, and ambient air was continuously pumped through the instrument at a rate of 20 l/min. As can be seen, with the speed of the car at about 35mph, two high peaks were detected in the central part near the mine, smelter, and dumps. C, ng/m 3 with RA Time, sec

ANALYTICAL INSTRUMENTATION MERCURY DETERMINATION with RA Performance characteristics and field study examples of three indoor air mercury measurement methods. Swartzendruber, P. and Prestbo, E.M. Frontier Geoscience, USA (poster) - 6th International conference on mercury as a global Pollutants, , Minamata, Japan. Lumex RA 915+ vs. Tekran 2537

No sample preparation “DIRECT” testing of FISH samples, results in 30 seconds! MERCURY DETERMINATION with RA-915 +

ANALYTICAL INSTRUMENTATION MERCURY DETERMINATION IN THE AQUEOUS SAMPLES MERCURY DETERMINATION Time, sec S, arb.un with RA – 2 ng/l, 6-8—10ng/l Calibration Mercury concentration, ppt S, arb.un Detection limit 0.2 ppt

MERCURY DETERMINATION to Lumex Clancy-a Zeemanless competition to Lumex with RA Clancy, the first US mercury sniffing dog employed at the Minnesota Pollution Control Agency. Lumex RA 915 analyzer present on the right.