CHE 185 – PROCESS CONTROL AND DYNAMICS

Slides:



Advertisements
Similar presentations
PID Control Loops Guy Zebrick.
Advertisements

PID Implementation Issues
Chapter 9 PID Tuning Methods.
Tuning PID Controller Institute of Industrial Control,
ERT 210 Process Control & dynamics
PID Controllers and PID tuning
INDUSTRIAL AUTOMATION (Getting Started week -1). Contents PID Controller. Implementation of PID Controller. Response under actuator Saturation. PID with.
Chapter 22. Variable Structure and Constraint Control
Briefing on Process Control and Dynamics Laboratory 20 January 2010.
CHE 185 – PROCESS CONTROL AND DYNAMICS
CHAPTER V CONTROL SYSTEMS
CHE 185 – PROCESS CONTROL AND DYNAMICS
CHE 185 – PROCESS CONTROL AND DYNAMICS
CHE 185 – PROCESS CONTROL AND DYNAMICS
CHE 185 – PROCESS CONTROL AND DYNAMICS PID CONTROL APPLIED TO MIMO PROCESSES.
CHE 185 – PROCESS CONTROL AND DYNAMICS
Feedback Controllers Chapter 8
Enhanced Single-Loop Control Strategies
CONTROL SYSTEM INSTRUMENTATION
© Goodwin, Graebe, Salgado, Prentice Hall 2000 Chapter 11 Dealing with Constraints.
Process Control Instrumentation II
Feedback Controllers Chapter 8.
Chapter 8. The PID Controller Copyright © Thomas Marlin 2013
Chapter 7 PID Control.
Cascade, Ratio, and Feedforward Control
Proportional/Integral/Derivative Control
Hairul Nazirah bt Abdul Halim
ERT 210/4 Process Control & Dynamics
Process Control: Designing Process and Control Systems for Dynamic Performance Chapter 7. The Feedback Loop Copyright © Thomas Marlin 2013 The copyright.
Course Review Part 3. Manual stability control Manual servo control.
CS 478: Microcontroller Systems University of Wisconsin-Eau Claire Dan Ernst Feedback Control.
What is Control System? To answer this question, we first have to understand what a system is Simon Hui Engineer Control and Informatics, Industrial Centre.
PID Controller Design and
ERT 210/4 Process Control Hairul Nazirah bt Abdul Halim Office: CHAPTER 8 Feedback.
Chapter 8 Feedback Controllers 1. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control.
Miss Hairul Nazirah bt Abdul Halim
Implementing PID on a microcontroller
Features of PID Controllers
Chapter - Continuous Control
Feedback Controllers Chapter 8
Control Loops Tune a Fish. Control Loops Tuning of a control loop involves selecting loop parameters to ensure stable control under all operating conditions.
LECTURE #2 PRINCIPLES OF CONTROL SYSTEMS. Control systems integrate elements whose function is to maintain a process variable at a desired value or within.
Automatic Control System V. Performance of steady-state.
Lecture 9: PID Controller.
ChE 433 DPCL Model Based Control Smith Predictors.
Advanced control strategies. CONTROL SYSTEMS The process parameters which are measured using probes described in the previous sections may be controlled.
MISS. RAHIMAH BINTI OTHMAN
Cascade Control Systems (串级控制系统)
ERT 321 – Process Control & Dynamics Feedforward & Ratio Control Ms Anis Atikah Ahmad
Process Control. Feedback control y sp = set point (target value) y = measured value The process information (y) is fed back to the controller The objective.
EEN-E1040 Measurement and Control of Energy Systems Control I: Control, processes, PID controllers and PID tuning Nov 3rd 2016 If not marked otherwise,
ERT 321 – Process Control & Dynamics Feedforward & Ratio Control
Feedback Controllers Chapter 8
Controllers and Positioners
Chapter 12. Controlling the Process
Advanced Control Schemes (Part 2) - Agenda
Feedback Control System
Introduction to process control
Auto-tuning of PID controllers
Electronic Control Systems Week 7 – PID Control
Process Control Engineering
Enhanced Single-Loop Control Strategies
Features of PID Controllers
Introduction to process control
Introduction to Process Control
Feedback Controllers Chapter 8
Control Systems Prof Swanson MECH 3550.
PID Controller Design and
INTEGRATOR (or RESET) WINDUP
Control Systems Prof Swanson MECH 3550.
Presentation transcript:

CHE 185 – PROCESS CONTROL AND DYNAMICS PID IMPLEMENTATION

Reset Windup for PID Controllers Windup results when the manipulated variable is not able to control to the setpoint resulting in sustained offset causing the integral of the error from setpoint to accumulate. When control returns, accumulated error causes an upset. Windup can occur when a control valve saturates or when a control loop is not being used (e.g., select control).

Windup example When deviations exceed maximum http://brettbeauregard.com/blog/2011/04/improving-the-beginner%E2%80%99s-pid-reset-windup/

Windup example Methods to counter – include limits http://brettbeauregard.com/blog/2011/04/improving-the-beginner%E2%80%99s-pid-reset-windup/

Windup example Methods to counter – include output limits http://brettbeauregard.com/blog/2011/04/improving-the-beginner%E2%80%99s-pid-reset-windup/

Reset Windup for PID Controllers Note that controller output saturates causing area “A” to accumulate by the integral action. After the disturbance returns to its normal level, the controller output remains saturated for a period of time causing an upset in y.

ANTI-WINDUP WINDUP OCCURS BECAUSE INTEGRAL CONTROL REMAINS IN EFFECT AFTER A PROCESS HAS REACHED SATURATION. ANTI-WINDUP IS INCLUDED TO PREVENT INTEGRAL CONTROL FROM CONTINUING TO OPERATE AFTER SATURATION HAS BEEN ACHIEVED. ANTI-WINDUP ALLOWS THE SYSTEM TO QUICKLY RETURN TO CONTROL CONDITIONS AT POINTS BELOW SATURATION

ANTI-WINDUP ANTI-WINDUP SHOULD BE INCLUDED IN ALL CONTROLLERS WHERE INTEGRAL IS EMPLOYED. WINDUP CAN BE A FACTOR IN SINGLE LOOP AND MORE COMPLICATED SYSTEMS

Anti-Reset Windup When the manipulated variable saturates, the integral is not allowed to accumulate. When control returns, the controller takes immediate action and the process returns smoothly to the setpoint.

ANTI-WINDUP ALTERNATE STRATEGIES CLAMPING - LIMITS THE CONTROLLER OUTPUT TO A SPECIFIC LEVEL INTERNAL RESET RESULTS IN PI CONTROL AND CAN BE USED WITH CLAMPING TO AVOID SATURATION EXTERNAL RESET USES OUTPUT FROM THE MANIPULATED VARIABLE TO AVOID SATURATION

Internal Reset Feedback

Conventional PI Controller Therefore, internal reset feedback is equivalent to a conventional PI controller. It still has windup, but controller output can be clamped.

External Reset Feedback An extension of internal reset feedback, therefore, it is equivalent to a conventional PI controller. When u saturates, windup will cease preventing windup. Less windup than clamping, but requires umeas.

BUMPLESS TRANSFER BUMPLESS TRANSFER OCCURS WHEN A SYSTEM IS SWITCHED FROM MANUAL TO AUTOMATIC CONTROL THE SYSTEM IS DESIGNED TO SET THE INITIAL OUTPUT EQUAL TO THE MANUAL VALUE THE SYSTEM IS THEN RAMPED UP/DOWN TO THE NEW TARGET VALUE. With bumpless transfer, an internal setpoint is used for the controller and the internal setpoint is ramped at a slow rate from the initial conditions to the actual desired setpoint to order to provide a smooth startup of a control loop.

BUMPLESS TRANSFER Control Performance With and Without Bumpless Transfer.

SPLIT RANGE CONTROL SPLIT RANGE IS USED WHEN THERE IS A NEED FOR MORE THAN ONE CONTROL RANGE THERE ARE TYPICALLY OVERLAPS IN THE RANGES OF OPERATION, BUT ONE ACTUATOR IS USED FOR HIGH FLOWS AND A SECOND IS USED FOR LOW FLOW RANGES USE OF PARALLEL FLOWS FOR HEATING AND COOLING IS ALSO SUGGESTED IN THE TEXT, BUT THIS IS NOT THE SAFEST FORM OF OPERATION BECAUSE IT CAN LEAD TO CONFLICT BETWEEN CONTROLLERS IN THE OVERLAP RANGE

SPLIT RANGE CONTROL Split Range Flow Controller

Example for Split Range Flow Control Uses parallel valves for naoh flow control

Example for Split Range Flow Control Titration Curve for a Strong Acid-Strong Base System Therefore, for accurate pH control for a wide range of flow rates for acid wastewater, a split range flow controller for the NaOH is required

PID FOR MULTIPLE INPUT/MULTIPLE OUTPUT (MIMO) SYTEMS COMPARISON BETWEEN CENTRALIZED AND DECENTRALIZED CONTROL DECENTRALIZED (MULTILOOP) CONTROL HAS SEVERAL SINGLE LOOP CONTROLS IN PARALLEL FOR A SINGLE PROCESS. REACTION SYSTEM EXAMPLE:

PID FOR MULTIPLE INPUT/MULTIPLE OUTPUT (MIMO) SYTEMS THE ALTERNATE TO THIS APPROACH IS CENTRALIZED (COORDINATED) CONTROL AND FOR THE SAME SYSTEM IT WOULD LOOK LIKE: