AN-NAJAH NATIONAL UNIVERSITY FACULTY OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING.
Advertisements

Heating, Ventilating, and Air-Conditioning
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Heating, Ventilating, and Air-Conditioning (HVAC)
Granulation Project 2 MECHANICAL SYSTEMS IN BUILDINGS IBN SENA HOSPITAL IBN SENA HOSPITAL Prepared by: Abdullah Hasayen Mazin Khalid Moath Ayyash Mohammad.
MECHANICAL SYSTEMS IN BUILDINGS selfeEt mall selfeEt mall Prepared by: Bilal Qzq Abdel Rahman Abu Salama Oraib Awad Moamen Hatab Supervisor: Dr. Ramiz.
Components of HVAC System
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
Heating and Air Conditioning I
AN-NAJAH NATIONAL UNIVERSITY FACULTY OF ENGINEERING DEPARTEMENT OF MECHANICAL ENGINEERING MECHANICAL SYSTEMS OF AL-OYOON HOSPITAL-NABLUS Graduation Project.
Introduction Enthalpy Wheel
HVAC SYSTEM DESIGN Businessmen Club Supervisor: Dr Salameh Abdulfattah
1 Meeting ASHRAE Fundamentals, Standard 55 & 62.1 with Chilled Beams Displacement Ventilation.
HVAC 7ab CNST 305 Environmental Systems 1 Dr. Berryman
PROJECT NAME: “Mechanical System for school of optical” (An-Najah university College) Prep ared by: Abdulla Alawneh Islam Salahat Mohammed Jaber Majdi.
HEAT LOAD ESTIMATING USING THE SHORT COMPREHENSIVE METHOD © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
The students: Mohammad Shabaro ( ) Mahmoud Mousa ( ) Yosri Asfour ( ) Supervisor: Dr. Iyad Assaf 1.
Energy Conserving Alternatives HVAC 15a CNST 305 Environmental Systems 1 Dr. Berryman.
Heat Loss and Gain Heat Loss and Gain
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
Lecture Objectives: Model HVAC Systems –HW3 Asignemnet Learn about eQUEST software –How to conduct parametric analysis of building envelope.
Equation solvers Matlab Free versions / open source codes: –Scilab MathCad: Mathematica:
Conditioning of Moist Air
Ductless Heat Pumps Sizing Example
Ductwork Systems and Supply Arch 432. What You Need To Know Become familiar with the materials sizing ductwork Understand sizing units.
Prepared by : Hashem Ihasn Janajreh Mohammad Abu Sarah Sari Khaled Sobeh Ahmad Medhat Attiyah Supervisor : Dr. Iyad.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
Drugs Addicts Rehabilitation Center
Prepared by : Ameed mahmoud qzaih Mohammad mustafa yaseen Samer abdelrazaq khanfar Supervisor : Dr. Eyad Assaf.
Prepared by : Abd Aljabbar Rabaya Ammar Salloum Sameh Shawahni Supervisor : Dr. Eyad Assaf 1.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
Graduation Project Mechanical system for Building of_ al Kuwait Surgery Specialized Hospital.
EXAMPLE EXERCISE CALCULATING HEAT LOSS & HEAT GAIN  Several exhibits in the class packet are necessary to understand the entries into the Heat Loss /
INTRODUCTION TO HEAT LOAD HEAT LOAD12 3 TOPICS COVERED INTRODUCTION DESIGN CONSIDERATIONS DEFINITIONS/CONCE PT/FORMULA THE FORM LOAD COMPONENTS –External.
HEATING AND COOLING SYSTEMS
Introduction to Energy Management. Lesson 4 Determining the Loads on the HVAC System.
Ductwork Systems and Supply Arch 432. What You Need To Know Become familiar with the materials sizing ductwork Understand sizing units.
Technical Seminar on Application and Technical Specification June 2016
Energy and Heat. What is Energy? When something is able to change its environment or itself, it has energy Energy is the ability to change Energy has.
SECTION 7 AIR CONDITIONING (COOLING) UNIT 35 COMFORT AND PSYCHROMETRICS.
Design & Analysis of Psychrometric Processes Various ways of Generating A Comfort… BY P M V Subbarao Associate Professor Mechanical Engineering Department.
Maria’s Restaurant Chapter 2 Section 9
HEAT GAIN CALCULATIONS
Under floor Heating Graduation Project submitted By: Adli Mosleh
RESIDENTIAL HVAC (HEAT LOSS & GAIN)
Heating, Ventilating, and Air Conditioning
PROJECT NAME: “Mechanical System for school of optical” (An-Najah university College) Prepared by: Abdulla Alawneh Islam Salahat Mohammed.
CONFIDENTIAL Technical Seminar on Application and Technical Specification 21 June 2016 Rezza Arif Bin Mustapa Kamal Senior Engineer Project And Application.
HVAC SYSTEM DESIGN ALMAQASED HOSPITAL
Heat Loss and Gain Heat Transfer Winter Heat Loss Summer Heat Gain
Al-Najah National University Mechanical engineering department
Graduation Project 2 Redesigning a Villa
Conduction Cooling Loads
Heating, Ventilating, and Air-Conditioning
Graduation Project – 2 Mini-Mall
Psychrometry & Air-conditioning
Course Name: Air-conditioning: Introduction Prof. A. D. Kale
Heat Loss and Gain Heat Loss and Gain
Heat Loss and Gain Heat Loss and Gain
Introduction.
FBE03: Building Construction & Science
Refrigeration & Air-Conditioning
Lecture Objectives Psychrometrics Define Heating and Cooling Loads
PROJECT NAME: HVAC AND MECHANICAL SYSTEMS DESIGN
Mechanical Systems Design for Al-Bahrain Hospital
Mechanical Systems For Al-Zakah Hospital
Heat Loss and Gain Heat Loss and Gain
Maria’s Restaurant Chapter 2 Section 9
Heat Loss and Gain Heat Loss and Gain
Presentation transcript:

AN-NAJAH NATIONAL UNIVERSITY FACULTY OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING

Five star hotel in Nablus Students name : Fadi ghssan foqha. Tareq Mousa. Ayman abo alshwareb. Motaz ‘abed . Supervisor: Dr :ahmed al ramahe Five star hotel in Nablus

Five star hotel in Nablus MECHANICAL SYSTEMS IN BUILDINGS Five star hotel in Nablus Five star hotel in Nablus

Five star hotel in Nablus The aim of this project is to design the Following Mechanical Systems to five star hotel in Nablus: Heating Ventilation and air conditioning (HVAC). Plumping system (Sanitary drainage system& potable water system). Fire Fighting system. choosing elevators for the hotel. Five star hotel in Nablus

Five star hotel in Nablus Note : We discus the Plumping system (Sanitary drainage system and potable water system) in project 1 . Five star hotel in Nablus

Five star hotel in Nablus HVAC System The main objective of air conditioning is to maintain the environment in enclosed space at conditions that induce the feeling of comfort to human. Five star hotel in Nablus

WINTER INSIDE AND OUTSIDE DESIGN CONDITIONS Five star hotel in Nablus Outside temperature To=4.7 ˚C. Inside temperature Ti=21 ˚C. Outside Relative humidity Фo=72% . Inside Relative humidity Фi=50%. Outside Moisture content Wo =8.4 g of water/ Kg of dry air. Inside Moisture content Wi =4 g of water/ Kg of dry air. temperature for the unconditioned spaces Tun=13.35 ˚C. Temperature for the ground Tg=12 ˚C. Five star hotel in Nablus

Five star hotel in Nablus HEATING LOAD EQUATIONS: Qs,cond = U A (Tin – To) . Q S,vent = 1.2 Vvent (Tin – To). Q L,vent = 3 Vvent (Wi- W o). Qtotal = Qs,cond + Qs,vent +QL,vent. Five star hotel in Nablus

Five star hotel in Nablus HEATING LOAD RESULTS: Floor Q)total .(w) Q)total .(kw) Q)total .(ton) Under ground 145986.66 145.987 41.73 Ground 118910.3 118.91 33.97 First 129917.3 129.91 identical Floor)9 )Floor 141972.25 141.97 40.564 Five star hotel in Nablus

The boiler is the main source of heating process, selection of boiler depends on its capacity. selection of boilers from Mansur company. The total amount of heat in our project equal to 2508.8 KW. Use catalog then the selected boiler according to catalog is MS30 found in the under ground floor in mechanical room . Where: H=2.45 m, D=2.05m ,L=3.38m, I=2.98m

SUMMER INSIDE AND OUTSIDE DESIGN CONDITIONS Outside temperature (To) be 30˚C. Inside temperature (Ti) be 24 ˚C. Outside Relative humidity (Фo) is 44%. Inside Relative humidity (Фi) is 50%. Outside Moisture content (Wo) is 12.5 g of water/ Kg of dry air. Inside Moisture content (Wi) is 9.4 g of water/ Kg of dry air temperature for the unconditioned spaces Tun=28˚C. Temperature for the ground Tg=26 ˚C.

COOLING LOAD EQUATIONS Qs = U × A × CLTD corr. For Wall And Ceiling. CLTD corr = ( CLTD + LM ) K +( Tin -25.5 ) + ( To – 29.4 ). Qs) conduction)glass = A × SHG × SC × CLF . For glass. Qs) convection)glass = U × A × ( CLTD ) correction. Qs)ven = 1.2 × A × ( To – T in ) . Q latent)ven = 3 × A ×( W o –W in ). Qs) people = sensible heat gain/person × number of person × CLF Ql) people = number of person × latent heat gain/person Qs) lighting = watt/m2 × CLF × Area Qs) equipment = qs * CLF Ql) equipment = ql Ventilation people

COOLING LOAD RESULTS Floor. No Q(Total) (Kw) (Ton) Under ground floor 146.08336 41.738 Ground 231 66 second Floor 434 124 Identical Floor)9 )Floor 276.5 79

The Chiller Code is: WPS a 960 3 S The chiller is the main source of cooling process, our selection depends on PETRA COMPANY. The cooling load in our project is 942.74 Ton. . So we select 960 ton R 134-a chiller it's manufactured with three compressors and with the same compressors type. The Chiller Code is: WPS a 960 3 S

DUCT DESIGN There are two methods for duct design : Equal pressure drop method. Velocity method. All the results of duct design based on equal pressure drop method .

PIPES DESIGN The total cooling load was calculated for the floor. The mass flow rate for the water calculated (m). The pressure head was estimated in (Kpa) . The longest loop from the boiler to the farthest fan coil unit and return to the boiler was calculated multiplying by (1.5) due to fittings. The pressure head per unit length is calculated and it should be between range from (200< ∆p/L<550). Then the diameter of pipe entering to the floor is estimated .

AIR HANDLING UNIT SELECTION The Air Handling Units were selected from PETRA COMPANY using PETRA catalogue: The ahu in this project are choosing according to the above code as in the following table:

Underground floor Name Load(WATT) CFM module number #1 21441 4100 PAH HC 50 C 6 H2 X2 # 2 17105 3020 PAH HC 30 C 6 H2 X2 #3 20242 3574.4 PAH HC 40 C 6 H2 X2 # 4 17715 1611.17 PAH HC 24 C 6 H2 X2 # 5 9124.1 3128.2 PAH HC 32 C 6 H2 X2 #6 9857 1740.6 GROUND FLOOR 1 119000 21013.4 PAH HC 250 C 6 H2 X2 SECOND FLOOR 2 161000 28430 PAH HC 320 C 6 H 2X2 3 98000 17305 PAH HC 200 C 6 H 2X2 4 42000 7417 PAH HC 80 C 6 H 2X2 IDENTICAL FLOORS 73500 1298.9 PAH HC 150 C 6 H 2X2

FAN COIL UNIT SELECTION In Our project we need Ducted FCU and to ensure the high level of comfort we need the filtered FCU our selection from Petra catalogs is CBP type. The FCU in this project are choosing according to the above code as in the following table(for the identical floors): Identical floor FCU Application Q TOTAL (KW) # 0f FCU Model # of FCU Bed room 7 29 RAC 12 CBP H/C 3

Pump selection: Our selection for pump depends on Evrot company For the building the selection of pumps were been as the following: Pumps for HVAC system for chiller and boiler FCE-FCS series: 65-1602/220 [Qb= 1134L/min, H= 95 m]. [Qchiller=1558.7L/min, H=67.5m] .

Fire Fighting system: We use in this project type of Wet Pipe System because wet standpipes may be used by building occupants may fight fires quickly. We used both of landing valve and cabins , and use ( NFPA) Code to be followed through designing . Main pipe passes with water flow of up to 500 gpm. And (4”) the main sizing pipe . Designed for landing valve and cabinet ,the designing on the farthest landing valve ,Is the supply line leading to it take ( 250gpm) and the Pipe leading to it were (2.5’’). The cabinet branch pipe (1.5”) , the flow rate (100gpm).

Pump selection: For our project firefighting pump was selected as a flow rate = 150m3/h, head= 14PSI, the model no. is from A-C Fire Pump Systems and pump series is 2000 model 4x3x9f.

ELEVATORS: Elevators Type in hotel is Geared-traction elevator. the speed is 450 feet per minute Gearless-traction The size of elevators in hotel is 6 feet8 inches wide by 5 feet5 inches deep; 3,500 pounds .