Goodman and Amana Furnace Orientation.

Slides:



Advertisements
Similar presentations
Residential Gas – Honeywell Valve - Thermopile Powered Series 300/301
Advertisements

Copyright© 2014 Austin Analytics Group, LLC. Stand Alone System High Temperature System Hazardous Area System Universal/Remote Display System Copyright©
Trane Voyager™ rooftop units
“Enerpak” Units » Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners,
PACKAGE UNITS GPG 10 AND 12 SEER.
Thermostats. I would recommend that as you proceed through this power point presentation that you refer to your textbook, Unit 14, for some great visuals.
HEAT PUMPS.
Mini 24 Presents the new. Wall-hung boiler Self diagnostic system Electronic thermometer Furnace type: open Output power: 22,66 kW Min. 6,7 kW Stars of.
Basic Refrigeration Cycle
Using Copper Water Loop Heat Pipes to Efficiently Cool CPUs and GPUs Stephen Fried President Passive Thermal Technology, Inc.
Engineered Products Make-Up Air for Heating and Cooling.
Welcome. TF Commercial Units Sizes from 150 to 400 MBH Propeller Units Power Vented, Direct Spark Ignition Standard Approved for Commercial & Industrial.
 25,000 BTU per Cell  Cell Halves Edge Seams Folded and Crimped. Individual Cells Welded Together to Form Completed Heat Exchanger Assembly.  20 Gauge.
New 90% Furnaces Features
Objective of the session.
Engineered Products Make-Up Air for Heating and Cooling.
Model “BTU” Model “BRT”  20 Gauge aluminized steel tubes  Single orifice (Model “BRT”) or multiple orifice (Model “BTU”) inshot burner  Tubes expanded.
Who Is ? Comfort-Aire is part of the Heat Controller family which for three-quarters of a century has provided quality products for conditioning.
Furnace Troubleshooting
Clean Air Box Usage & Care CABs RAMs CO Monitors.
Unit 12 Oil Heat Components
The Mondial Forni Mondial and Ecomondial steam tube fixed deck ovens, gas or gasoil heated, are composed of independent decks with standard working height.
DIVATOP 60 New Wall Hung Gas Fired Boiler. Divatop 60: Main Features Leader in wall hung boilers Ferroli Ferroli, in line with its position as a comfort.
Engineer Presentation
Product Introduction.
ST9120U1003 Universal Electronic Fan Timer Training Module
S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module
Table of Contents Safety Circuits Induced Draft Motors Gas Valves
Variable Speed Indoor Blower Motor Robert Helt Technical Conference - Panama City Beach, Fl
» Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners, and Flue Collector.
Pressure Switches. New modulating and multi-stage furnaces are more complex and require that installation instructions and procedures be followed so that.
Daikin Australia Pty. Limited Ducted Split Systems 2011.
Service/Review... Rule # 1: Use the KISS Principle!
Student Handout Packet Go to page A4. Please answer the following questions using page A4.
Gas Furnace Planned Maintenance
Fan Switch and Limit Switch Information. FAN Switch.
Wind Energy Station Directions. Simple Wind Generator 1.Connect the LED to the motor in the pvc stand (using the red and black wires). 2.Place the motor.
7.3.5 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Function and Characteristics of Draft Fans & Controls High efficiency.
MODEL : EDF-102 SERIES 1. APPLICATION The EDF-102 thermostat is designed to provide temperature control of heating or cooling systems in villas, hotels.
CONTROL BOX RMG
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
World Leaders in Combustion Management Solutions Module Gas Setup Introduction The Mk7 E.G.A Cell Status Further Information.
Product Introduction January 2009
Student Handout Packet – Page A7
Unit 8 Gas-Burning Equipment. OBJECTIVES State the difference between a natural gas and an LP gas system. Describe several control sequences for gas heat.
What makes up a Unico System
Rapid Change Technology The following is a presentation to aid Technicians in the replacement of the Rapid Change Technology Block.
We apply 120 VAC to the HM Unit (Remember to check polarity!) Our primary step down T/X provides power to terminal “X” and “COM” on the ignition control.
Air condition installation
Kaeser Direct Drive CSD Rotary Screw Compressors
Welcome to the 13 th Annual TSA Conference, 2016.
E3 HVACR Controls and Devices
Duct Free System.
New Air Handler Platform
Unit 13 Oil-Burning Equipment
Unit 7 Gas Heat: Natural and LP
10 12 and 14 TR Advanced Glycol Chiller
E3 HVACR Controls and Devices
10TR Nominal Glycol Chiller
New Air Handler Platform
CONTROL BOX RMG
CONTROL BOX RMO
CONTROL BOX RMO
Goodman and Amana Furnace Orientation.
ST9120U1003 Universal Electronic Fan Timer Training Module
Universal Interrupted Electronic Oil Primary R7184U Training Module
Presentation transcript:

Goodman and Amana Furnace Orientation

Complete Line of Furnaces 80% AFUE 92 - 95% AFUE

Nomenclature / Summary G M S 8 045 3 A N 1st 2nd 3rd 4th 5th 6th 7th 8th 9th GKS9 GMS/GDS8 GMH8/95 GDH8/GCH9 GME8 GMV95 GCV9 AMH8/95 AMV8 ADV8/ACV9

Goodman Single Stage (S) Patented Aluminized Tubular Heat Exchanger Stainless Steel Secondary Heat Exchanger – 92% Models Norton Mini-Igniter Self Diagnostics LED Four Speed PSC Motor Upflow / Horizontal Downflow – 80% only

Goodman Two Stage (H) Aluminized Heat Exchanger Stainless Steel Secondary HE – 93% to 95% Models Single or Two Pipe Flue – 90% Silicon Nitride Igniter Stored Self Diagnostics Two Stage Gas Valve Upflow / Horizontal / Downflow

Don’t Take Our Word For It

Goodman Two Stage (V) Aluminized Heat Exchanger 90% Models Only Variable Speed Motor – ECM Premium SEER Model Color Coded Connections Silicon Nitride Igniter Self Diagnostics LED Upflow, Downflow & Horizontal Models Available

ECM Motor (V Models) Low Power Consumption Virtually Unlimited Speed Options Dip Switch Speed Orientation Set-Up Designed To Overcome System Static Future Models Allow Communication Features

ECM vs. PSC

Coming Attractions – 80% Impacts The Entire 80% Line Same Features, Just Shorter 1st & 2nd Quarters - 2009 39” 33-1/3”

Amana Two Stage (H) Stainless Steel Tubular Primary Heat Exchanger SS Secondary HE – 90% Single or Two Pipe Flue Silicon Nitride Igniter Stored Self Diagnostics Two Stage Gas Valve Upflow / Horizontal

Amana Two Stage (V) Stainless Steel Tubular Primary Heat Exchanger 80% & 90% Models Variable Speed Motor – ECM Color Coded Connections Silicon Nitride Igniter Self Diagnostics LED Upflow, Downflow & Horizontal Models Available

Unit Replacement Warranties

The Competition

Wrinkle-Bend Technology Manufacturing Stress Including Wall-thinning Is Minimized Wrinkles Promote Turbulence To Aid Heat Transfer Efficiency

Dual-Diameter Muffler-Joint The Large Tube Fits Inside The Small Tube Tubes Are Solidly Joined With A Crimping Process Thermal Growth Ensures A Tight Seal Combustion Air Velocity Is Optimized Efficiency Is Maximized

Clamshell Design Some Competitors Still Use Clamshell But Why? Carrier Clamshell Lennox Clamshell Trane Clamshell Some Competitors Still Use Clamshell But Why?

The Best Heat Exchanger ANSI.Z21.47 Test Began in 1995 Repeated Thermal Cycles From 200F To 1,100F As of August 2008 the Million-Air Heat Exchanger Achieved 1,929,000 Cycles That’s More Than 38 Times Better Than Trane And It’s Still Going! Guess when the Amana heat exchanger hits 2 million cycles for a chance to win big prizes at www.amana-hac.com!!! Goodman HE – 25,510

120-Volt SiNi Ignition System All Models Except Value Models (GMS And GKS) Most Durable And Reliable Igniter In The Industry Seven Times Stronger Than Silicon Carbide More Reliable Than 90-volt Sini Less Sensitive To Grounding

Selectable Single or Two-Stage Furnace Ships as a Single-Stage Unit Flip This Switch To Activate 2-Stage Operation This Switch Adjusts Low-Stage Timing Between 5 Minutes Fixed or Self-Adjusting Mode

Self-Adjusting Low-Stage Call For Heat Call Satisfied Self-Adjusting Low-Stage High Low 1 to 12 min Cold = 1 min Mild = 12 min Off This Switch Adjusts Low-Stage Timing 5 Minutes Fixed Or Self-Adjusting Fixed 5 min Low-Stage

Stored Diagnostics (Last Five Faults) Push and Hold Button For 2 Seconds LED Flashes Out Last 5 Diagnostic Codes Most Recent Fault is Displayed First and Least Recent Fault is Displayed Last

Low Constant Fan Mode All AMH & GMH Furnaces Have Three Operational Speeds: Cooling – High Stage Cool High Heat – High Stage Heating Low Heat - Comes On When The Furnace Operates On Low-Stage Or Constant Fan Speeds Low Heat Cooling High Heat

Color-Coded, Low-Voltage Label Featured On All Goodman and Amana Models Except Value Models (GMS8-B & GKS9) Reduces The Chances of Wiring Error

Compare Us To The Competition And You’ll Be Convinced… Goodman Quality Compare Us To The Competition And You’ll Be Convinced… Why Pay More For Less?