Programmable clean lint screen reminder OPT is available in capacities of 50 to 170 lb – Operating cost savings Easy manual programming and infrared using.

Slides:



Advertisements
Similar presentations
Clothing Care Chapter 17 page 258.
Advertisements

Saving Energy, Timer & Automation Best Design Course 30 Minutes Test 10 Minutes TIS Training Program 2012, Rev 1.1
Grain Handler U.S.A..
ELLIOTT BAY INDUSTRIES
IGCSE ICT Control Systems.
Operating Functions.
The Laundry Process As a result of completing this activity you will be better prepared to keep your clothes clean and looking their best longer.
Mass Flow Controller. Function Delivers user specified flow rate of gas. Flow rate is mass flow rate (i.e. number of molecules per sec Mol/sec), not volume.
ENERGY SAVING Product Offering COMPRESSOR MARKETING OPPORTUNITIES.
Kenmore Front Load Washer & Dryer
Thermostats, Pressure Switches, and Other Electric Control Devices
Venstar Thermostats T5800 & T6800 ColorTouch. Residential T5800: 7 day programmable, vacation mode Compatible with almost all types of equipment; HP,
Total HVAC Control from anywhere Easy control that can save a fortune
Energy Service Productivity Management ©2007 ESPM Energy Consultants, L.L.C. All Rights Reserved.
= ( es ) 2 energy savings. 53% SAVINGS* THAN OTHER LEADING INVERTERS! Best Energy Savings! High 11+ EER CASSETTE INVERTER FLOOR STANDING INVERTER HIGH.
HYDRO POWER SOLAR POWER WIND POWER BIO POWER PETROLEUMCOAL NUCLEARNATURAL GAS.
Mrs. Hayes Home & Careers
Laundry 101 Fashion and Textiles. So, you have a huge pile of laundry, now what? You need to sort it!!! But how?
Sustainability is Good for Business HOUSEKEEPING DEPARTMENT.
 Fabrics and Colors  Washing Machine Cycle  Detergents and other Laundry Additives  Dryer Cycle.
Poke Yoke Mistake-proofing.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
Bi Fuel Automotive Technologies Who we Are Fyda Energy Solutions is in a partnership with Prins and American Alternative Fuel bringing practical Alternative.
GENERAL IDEAS IN AIR POLLUTION CONTROL
Engineer Presentation
Department of Energy Energy Savers PowerPoint: Save Energy and Money Today 1 of 12.
Clothing Care Chapter 14 & 15
ELEC 1041 Digital Electronics Tutorial: Word Problems
Settings & Adjustments. Settings & Adjustments.
Temperature Controller for Infrared Paint Curing September 13, 2001 Dec01-11 Team Members Michael Burman, CprE Jonathan Johnson, EE Matthew McMullen, CprE.
Air Conditioning Heating Refrigeration
MCS’S MAGNUM DIAGNOSTICS PACKAGE Visit us at
Quick Start Guide DRAFT. 1.Prepare Laundry Check pockets for small loose items. Close zippers and fasten hooks. Separate whites, darks, light colors,
Power Control System for a Concrete Durability Test Cabinet – Phase 2 Jacob Jameson Madhav Kothapalli Thomas Persinger Andrew Versluys.
Mistake-proofing Methods
EEV-KIT For Single refrigeration system. Preliminary information, all of contents are subject to final confirmation by MHI 2 Contents 1. Single refrigeration.
Day 10 Environmental Systems I Daylight as a primary lighting source Artificial lighting as a secondary source Room 102 Architecture Building.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
New Line 5000 Dryers Dryer T5290 – T5550 – T5675
Click left mouse button to advance, “back” to return Phasefale November 2007 Presscon Network Click left mouse button to advance, “back” to return.
TECHNICAL TRAINING INVERTER-Y
Pressure-Enthalpy and the Variable Refrigerant Cycle
L AUNDRY. Why do we need clean clothes? Why is it necessary to know how to do your own laundry?
Introduction to Energy Management. Week/Lesson 12 Advanced Technology for Effective Facility Control.
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
Service Section Technical Training December 2005.
Charging Cart Instruction & User Manual EnTrans Technology Co., Ltd.
How to do Laundry 1. Check the pockets. 2. Check for tears or rips 3. Check the care label- separate any that say “dry clean or hand wash etc) 4. Pretreat.
Automating Your Water Treatment Program Presented by:
Clothing Care. Two ways you can learn about your clothing:  1. Hang Tags – Are larger tags attached to new garments. Are removed before wearing. Include.
USER GUIDE TEMPERATURE CONTROLLER TR-2006 Hot runner temperature controller ShenZhen TanRex Electronic Co.ltd.
ENERGY SAVING AND EFFICIENCY OF AIR CONDITION & LIGHT SYSTEMS AT PUBLIC BUILDINGS Meitav-tec (Contel group)
Speed Queen Front Load Washer
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
FLoor Heating Controller
FLoor Heating Controller
New Line 5000 Dryers Dryer T5290 – T5550 – T5675
Industrial Assessment Center Database
EnTrans Technology Co., Ltd.
Asahi/America Electric Actuators Series 94.
BRC1E61 – Energy Saving Function
The advantages of going wireless
FINN-POWER e-technology - 14 years of excellence
Dry Kilns for Food.
Sustainability Left click to advance $200 Billion
Humidity Control Applications Flakt Dryers
Millennium touch screen Operated Profiler Series Roaster control
Asahi/America Electric Actuators Series 94.
2015 EPRI Heat Rate Conference
Bathless Tablet Disintegration Instrument with Auto Endpoint Detection
Presentation transcript:

Programmable clean lint screen reminder OPT is available in capacities of 50 to 170 lb – Operating cost savings Easy manual programming and infrared using OPTimum software 30 fully programmable cycles with factory settings – Cycles can be modified and turned off/on based on requirements We offer: timed dry, auto dry (based on first heat cycle), and moisture dry (samples dryness level throughout ENTIRE cycle) Anti-wrinkle feature – Tumbles load every 2 minutes for 60 minutes after cycle ends Less energy usage Optional end of cycle signal output Features of Control

Stack Tumblers Single Pocket Tumblers Controls Easy and intuitive to operate –Select cycle using arrows and press START

3 cycle types –Time Dry Programmable time and temperature –Auto Dry 11 programmable Automatic Dryness Levels and programmable temperature –Moisture Dry (Optional) Will dry to programmed moisture level at programmed temperature Cycle Types

Cycle On/Off Reversing Segment –On/Off –Rotate and Stop Time Drying Segment –Temperature and Time Cool Down Segment –Temperature OR Time Cycle On/Off Reversing Segment –On/Off –Rotate and Stop Time Drying Segment –Temperature and Dryness Level Cool Down Segment –Temperature OR Time Cycle On/Off Material (Cotton, Blend, Bedding, Delicate, Synthetic or Wool) Time Past Target (Advanced Option) Reversing Segment –On/Off –Rotate and Stop Time Drying Segment –Temperature and Moisture Level (0%, 1%, 3%, 5%, 7%, 10%, 15%, 20%, 25%, 30%, 35%, 40%) Cool Down Segment –Temperature OR Time Time Dry Auto Dry Moisture Dry Cycle Types

Temperature Time Time Dry Auto Dry Temperature Dryness Level Moisture Dry Material Temperature Target Moisture Cycle Types

Multiple Drying Segments Theory –Fact: Wet linens can handle more heat than dry linens. –Theory: While linens are wet, dry at high heat and gradually lower temperature to recommended drying temperature as more water evaporates and load gets dryer Multiple Drying Segments Example –Care label says: “Dry at 130°F” Without segment based drying you dry at 130°F –With segment based drying you can dry like this At 190°F until 30% moisture remaining At 160°F until 20% moisture remaining At 130°F until target moisture is reached Multiple Drying Segments

–Auto Dry calculates the drying time on the first heat cycle –OPT determines the remaining moisture based on input from the sensors throughout the ENTIRE cycle The result is that OPT is VERY accurate OPT vs. Auto Dry 75 lb Natural Gas Tumble Dryer

OPT: Over-drying Prevention Technology Reduce Labor Costs Lower Energy/Utility Costs Lower Linen Replacement Costs Maintenance Free Performance ALS Moisture Sensing Survey 79% respondents believe laundries over-dry by more than 8 minutes. 84% respondents believe that only 20% of managers realize they are over-drying.

OPT maximize throughput and minimize operating cost Labor Cost is 50% on Every $1.00 Laundry facilities are less efficient due to over-drying. Reducing over- drying can: – Increase throughput –Decrease cycle times –Reduce utility waste –Lessen the frequency of linen replacement due to reduced fabric wear. OPT is also valuable in WET cleaning applications where accurate moisture is important for fabric conditioning.

Efficiency Drying efficiency is often defined with terms like “gas usage” and “input Btus” –Reducing utilities doesn’t address a laundry most significant expense—Labor On average laundry facilities spend 10 times on labor cost as they do on utilities

Over-drying costs tumblers users utilities and throughput. OPT can reduce utility costs and increase throughput. If a laundry facility is over-drying by 8 minutes per load with a 75 lb tumbler, OPT can save: $883 per year in natural gas utilities $4,867 per year in labor If the laundry can process just one more load per day with a 75 lb tumbler for the duration of a year with a 75 lb: The laundry can process an extra 18,250 lbs per year by the Numbers

The Cost of Over-drying

Linen replacement cost can range between 18-25% of the laundry dollar. When over-drying is eliminated linens experience 31% less fiber loss. Affect on Linens *According to ALS lab tests

How OPT Works OPT measures the conductivity of the load –Measurement is read between a maintenance free electrically isolated lifter and the cylinder wall. As the load dries, conductivity decreases. –The conductivity signal (wetness) of the load is transferred from the rotating cylinder to a rotational switch located in the center of the cylinder bulkhead. – The maintenance free rotational switch transfers the signal to stationary wires. The wires transfer the signal to the control. – The control reads the moisture level of the load. – The control discontinues drying when the user set remaining moisture content is attained

Sensing Layout

Stationary bulk head ADC 2 in 2 of load contact Hard wire 3 moisture level settings Similar in 2 of load contact as IPSO Electrolux/ Wascomat 16+ moisture level settings Brush contactor may degrade over time Competition’s Moisture Sensing

534 in 2 of load contactMaintenance free signal transmission 12+ moisture level settings OPT

New OPL Micro Control- OPT highlights Advanced algorithm allows for moisture level selection of 0,1,3,5,7,10,15,20,25,30,35,40% Additional heat time for fine tuning 6 Load material type selections ADC has 3 general moisture settings Miele, Electrolux/ Wascomat also have multiple settings Lifter Used as Sensors Two entire lifters used for sensing Lifters are isolated from cylinder Load provides conductance from lifter to tumbler Maintenance free ADC momentarily touches the load with one small set of stationary contact strips Miele, Electrolux/ Wascomat use lifters Rotational OPT Switch Assembly Receives constant signal from sensors and sends to micro controller Rotational Switch life expectancy- billions of rotations Maintenance free ADC limited to testing a small sample of the entire load Miele, Electrolux/ Wascomat use external brush contactors susceptible to wear and maintenance