2-3-1 N uclear B iological C hemical AIRCREW CBR ENSEMBLE Fitting Procedures Chemical Biological Radiological.

Slides:



Advertisements
Similar presentations
Personal Protective Equipment (PPE)
Advertisements

Scope Statement This lesson provides responders with information regarding procedures for selection, inspection, and safe use of appropriate personal protective.
CBRNE Training Academy
1-2-1 N uclear B iological C hemical AIRCREW CBR ENSEMBLE Donning Procedures Chemical Biological Radiological.
CBR-D PPE Mask and Suit.
HAZMAT for ED Staff 2012.
CBR Suit Training Disaster Preparedness and Management Unit.
Decontamination at a suspected radiological incident.
Personal Protective Equipment (PPE)
Pharmaceutical Manufacturing Clean
SWEDISH EMERGENCY DISASTER EQUIPMENT PREPARATION & DONNING PPE.
Respirator Awareness Training CFR
Personal Protective Equipment (PPE) in Healthcare Settings
Powered Air Purifying Respirator (PAPR) Infection Control Unit.
PPE Use in Healthcare Settings: How to Safely Don, Use, and Remove PPE
M40 FIELD PROTECTIVE MASK
2-2-1 N uclear B iological C hemical AIRCREW CBR ENSEMBLE AIRCREW CBR ENSEMBLE CMU-29(V)2/P Overvest Chemical Biological Radiological.
Unit 7.2. Respirator fit testing TB Infection Control Training for Managers at National and Subnational Level.
2 Fire Fighter Qualifications and Safety Skill Drills.
Troubleshooting Guide. Table of Contents 2 Shower Filter 3 Leak Between Top Housing & Filter4 Leak Between Swivel Collar & Housing5 Leak at Top of Swivel.
Servicing Welch DRYFAST ULTRA Pump Models 2032
Radiation Protection Technology Respiratory Protection Air Sampling Radiological Safety and Response RPT-243-PE-6.
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
Intermediate SFFMA Objectives: – Hrs received.
31 Hazardous Materials: Personal Protective Equipment, Scene Safety, and Scene Control.
NBC CTT Tasks Presented by:. NBC CTT Tasks Presented by:
Personal Protective Equipment. Objectives (1 of 2) Describe the role of personal protective equipment (PPE) for firefighters. Define the relationship.
OSHA’s Respiratory Protection Standard 29 CFR
1-3-1 N uclear B iological C hemical AIRCREW CBR ENSEMBLE Emergency Procedures Chemical Biological Radiological.
DONNING & REMOVING Personal Protective Equipment (PPE) for SARS
Donning and Removing Personal Protective Equipment Practicum
AIRCREW CBR ENSEMBLE A/P22P-14(V) Respirators
Donning PPE (with N95) Level The emerging EBOLA preparedness is new for our nation and our organizations. Information changes rapidly, sometimes.
S.C.B.A. MAINTENANCE By: Lt. Eric Miller Parksville Fire Department.
Aircraft Systems Oxygen Systems A-4N/TA-4. Aircraft Systems Oxygen System LESSON OBJECTIVES To give the TP information on the Oxygen System to include.
Fitting of Personal Protective Equipment (PPE) and taking swabs for influenza This presentation is for quick reference only. You must also complete the.
Personal Protective Equipment An Employee Awareness & Training Course
Powered Air-Purifying Respirator (PAPR) Copyright © 2015 by The S.E.A. Group.
Donning PPE (with PAPR) Level The emerging EBOLA preparedness is new for our nation and our organizations. Information changes rapidly, sometimes.
FILTERING MDP. Safety and Safety Gear  When filtering from a fermentation vessel you should never use carbon dioxide to push the beer through the filter,
Personal Protective Equipment
1. The 3M manufactures 2 types of Powered Air Purifying Respirator (PAPR) to be worn to provide respiratory protection for those staff members who have.
ENGINE CLEAN OIL TOOL OIL RX • 999 TRAINING
Personal Protective Clothing and Equipment 1. Introduction Difference between injury and safety determined by personal protective equipment (PPE) PPE.
2-5-1 N uclear B iological C hemical AIRCREW CBR ENSEMBLE Inspections Chemical Biological Radiological.
Respirator Safety This Training Covers Respirator Inspection User Fit Checks Respirator Cleaning Respirator Storage.
Paratech Air Struts SECTION: Tools and Equipment ISSUED: REVISED: ##-####
Personal Safety In Agricultural Mechanics. Objectives State how to create a safe place to work. Recognize hazards in agricultural mechanics Select appropriate.
3-1-1 N uclear B iological C hemical AIRCREW CBR ENSEMBLE Portable Test Kit Chemical Biological Radiological.
1 Fire Fighter Qualifications and Safety Skill Drills 2.
1 Skill Drill 2-7 Donning a Face Piece Step 1: Fully extend the straps on the face piece. Step 2: Place your chin in the chin pocket. 2 Step 3: Fit the.
Automotive Air Conditioning and Repair 7-1 Goals of P2 in Automotive Air Conditioning Service Work n Pollution Prevention Goals –Minimize refrigerant vented.
20051 Surface Rescue Swimmer School Aviation Life Support Systems LT 4.5.
Surface Rescue Swimmer School Mask, Fins, and Snorkel Mask, Fins, and Snorkel LT 4.2.
2-4-1 N uclear B iological C hemical AIRCREW CBR ENSEMBLE Donning Procedures Chemical Biological Radiological.
PUBLIC SAFETY INSTRUCTIONS
CHEMICAL HANDLING Standard Operating Procedures and Personal Protective Equipment For REACT-OX® Program Applications.
Donning and Doffing SCBA Firefighter I. Copyright © Texas Education Agency All rights reserved. Images and other multimedia content used with permission.
Protect Yourself From Chemical/Biological Contamination Using Your Assigned Protective Mask
1 2 3 Terminal Objective Don full O.R. attire and perform visual check of other personnel for attire upon entry/exit from the O.R.
Protect Yourself From Chemical/Biological Contamination Using Your Assigned Protective Mask.
EBS-1 # COOLANT FLUID EXCHANGE QUICK REFERENCE ATTENTION: Using the Coolant Fluid Exchange requires the FILL and VAC Valves on the SERVICE.
Copyright © 2016 by The S.E.A. Group
Fitting of Personal Protective Equipment (PPE) and taking swabs for influenza This PPE module presentation is also accessible on the MLE (Managed Learning.
M40 GAS MASK.
PPE Donning and Doffing
Job Performance Requirement 7-4
2 Fire Fighter Safety.
CBRN Overview SGT Hubbard, Bobbie Lee | 2015.
PPE Donning and Doffing
Presentation transcript:

2-3-1 N uclear B iological C hemical AIRCREW CBR ENSEMBLE Fitting Procedures Chemical Biological Radiological

2-3-2 TERMINAL OBJECTIVE n To familiarize Flight Equipment personnel with the proper procedures for correctly fitting aircrew with all components of the Aircrew CBR ensemble.

2-3-3 ENABLING OBJECTIVES Discuss the procedures for mask fitting Perform procedures for orinasal mask sizing Perform procedures for hood sizing Perform procedures for fitting of nose occluder Discuss final fitting and adjustment procedures Discuss the procedures for BTN fitting.

2-3-4 OVERVIEW n Introduction n Initial sizing, fitting and adjustment –Orinasal mask –Hood –Nose occluder n Final fitting and adjustment n Fitting of BTN

2-3-5 INTRODUCTION n The procedures shall be performed at the designated organizational maintenance level by a qualified Aircrew Survival Equipmentman. NOTE To make up a complete assembly, the appropriate mask assembly and nose occluder kit must be individually requisitioned.

2-3-6 INITIAL SIZING and FITTING n Mask Preparation –Select proper mask size –Remove rubber blanking plugs if nose occluder is to be used. NOTE Retain blanking plugs for future use if mask is converted to variant 1

2-3-7 ATN SIZING and FITTING n Orinasal mask sizing –Invert hood to expose the mask –Hold mask firmly to face –Crimp hoses so no air can be breathed through –Inhale deeply to test mask seal Video

2-3-8 Inverting Mask

2-3-9 Orinasal mask sizing Back

ATN SIZING and FITTING n Hood sizing –Don skull cap and/or headband –Turn pusher fan “ON” –H-manifold knob in horizontal “ON” position. –Hood outlet valve open vs closed –Don the hood Video

Un-inverting Mask

Hood sizing Back

ATN SIZING and FITTING n Nose occluder fitting –Select nose occluder size occluder sizeoccluder size n 60% wear 6L –Apply Krytox to shaft assembly –Lubricate o-ring seals –Insert shaft assemblies –Position stirrup assembly –Check function n Refer to Fitting Flow Diagram for trouble shooting. Diagram Video

Nose occluder fitting

NOSE OCCLUDER

FITTING FLOW DIAGRAM

FINAL FITTING & ADJUSTMENT n Donning for fitting –Don CMU-29(V)1/P or (V)2/P vest –Don skull cap –Turn pusher fan “ON” –H-manifold horizontal “OPEN” –Don the hood (hood outlet valve “OPEN”) –Pusher fan “OFF” –Don helmet

FINAL FITTING & ADJUSTMENT n Donning for fitting (cont.) – Connect intercommunication unit – Pusher fan “ON” – Connect toggle harness assembly to helmet – Flip V-bow down in to flight position – Clamp hood ventilation hose – Wearer holds breath –Check for leaks n Perform location drills and EPs

BTN FITTING n Chemical Under- garments –Check sitting, crouching, and reaching –Avoid issuing a bulky or oversized liner –Correct fit allows proper integration with flight suit

BTN FITTING n Gloves & Inserts (old style gloves) –Issued as a set –Snug but not restrictive fit –Correct fit allows proper integration with flyer’s gloves n Gore HSF liner –Snug but not restrictive fit –Worn with Canadian flight gloves

BTN FITTING n Disposable footwear covers –Find best fit n Chemical protective socks –One size only, no fit required

Lessons Learned n Aircrew should plan on using winter sized flight gear. n Go one to two sizes up on flight gloves (for old system gloves) n Have G-Suit fit check prior to donning. n CPU measurement. Top =flight suit size. Drawers = Jean waist size n Proper ensemble fitting is critical for CBR protection and aircrew comfort. n When fitting recommend leaving 6L nose occluder in mask as 75% wear this size. Have another mask in which you can switch out nose occluder sizes

Questions? n How do you size for the mask? n How do you size for the CPUs? n How do you size for the CBR socks?