Analyzing the forces within unilateral transtibial prosthetic sockets and design of an improved force minimizing socket Christine Bronikowski, Amanda Chen,

Slides:



Advertisements
Similar presentations
Prosthetic Technology
Advertisements

Load Cell &DP Cell 2007-CHEM-17.
Force Sensitive Resistor October 19th, 2009 Johnnie Chang.
TF SOCKET BIOMECHANICS
Ankle Joint It consists of a deep socket formed by the lower end of the tibia & fibula , into which is fitted the upper part of the body of the talus .
Changing Seasons “The hardest thing about learning something new, is unlearning the way you know it now.”
Amanda Neves URI Biomedical Engineering.  Fit of the prosthesis is extremely important for the comfort of the limb and prevent skin irritation or pain.
Bryan Humble CPO/LPO Precision Prosthetics
This slide to be displayed before Webinar begins.
Ankle-Foot Orthoses (AFOs)
The Effect of Transtibial Prosthesis Suspension on Residual Limb Pistoning Austin Balogh MSPO Research Presentation April 23, 2008.
Seating and Positioning. Let’s talk about Safe walking first.
SKIN INTEGRITY SHARON HARVEY 23/03/04. LEARNING OUTCOMES THE STUDENT SHOULD BE ABLE TO:- ILLUSTRATE THE STRUCTURE AND FUNCTION OF MAJOR COMPONENTS OF.
1 Embedded Stroke Evaluation System Amanda Sweeney, 4ECE Supervisor: Martin Glavin.
QUICK TIPS (--THIS SECTION DOES NOT PRINT--) This PowerPoint template requires basic PowerPoint (version 2007 or newer) skills. Below is a list of commonly.
Position Sensing Glove Barbara Tuday Nathan Schreppler Lauren McIlwain Michael Nolan Team 6:
Check-out procedure (PP Lower Limb Prosthesis) Polypropylene Technology International Committee of the Red Cross.
Mentor, John R. LaCourse: Nicholas Parrott: Erick Janampa: Project Definition “ The goal of this project.
Lower Limb Prostheses Description
Lower limb. Consists of thigh, leg, ankle and foot.
Shear Definitions, Relationships and Measurements Geoff Taylor – VP Research and Development, Vista Medical Inc. Winnipeg Canada.
Transtibial Amputation
Seminar/seminar /ming.ppt 1 Tacking the challenges to professional education arising from the pace of technological development and the need for.
November 17, 2009 Introduction to Cognitive Science Lecture 19: Robotics 1 Robotics environment agent ? sensors effectors Robots have physical sensors.
Biomechanical correlates of exercise – areas of interest, endeavor, & contribution Design/analysis of fitness programs Design of fitness exercises –are.
INTELLIGENT ROBOT WALKER. AVAILABLE DEVICES The PAM-AID Reactive device Basic obstacle avoidance Not supportive more an aid for the blind The SMARTCANE.
Analyzing the forces within unilateral transtibial prosthetic sockets and design of an improved force minimizing socket Christine Bronikowski, Amanda Chen,
Intervensi Ortotik Prostetik Pada Diabetik Foot IOPI Konferense Solo 2010 Markku Ripatti.
The Skeletal System – OrganizationDay 2
Dr. Waseem Bahjat Mushtaha Specialized in prosthodontics
Neuroprosthetics Week 6 Design Issues. Neuroprosthetic Devices Three basic types Three basic types 1. Use neural signals as an input, possibly to control.
SDMAY11-01 Advisor: Dr. Ajjarapu Team Members: Luke Rupiper Shonda Butler Andrew Nigro Ryan Semler Chad Hand.
Track & Field: Warm-up, Stretching, & Flexibility
Wheelchair Seating and Positioning Sarah Crosbie, MS.Ed, OTR/L.
Examination of balance PTP 565. Quote of the day The greatest crime is not developing your own potential. When you do what you do best, you are helping.
Analyzing the forces within unilateral transtibial prosthetic sockets and design of an improved force minimizing socket Christine Bronikowski, Amanda Chen,
Determining Level of Postural Control in Young Adults Using Force-Sensing Resistors Student ID : M Student : Kun-Hong Lee Adviser : Ming-Yuan Shieh.
Improved Lower Limb Prosthesis
Elevated Vacuum Suspension
ALTERNATIVE TREATMENT IN PATIENTS WITH
Components of Physical Fitness. Physical Fitness  Physical fitness is the entire human organism’s ability to function efficiently and effectively. It.
Arm as Good as New Ethan Leavell Sulamita Staroverova Jalen VanTrease Tolu Amudipe.
Targeted Muscle Reinnervation for Control of Myoelectric Arm Prostheses By. Rory Makuch.
Part 1: Assessment for Prosthetic Use & Stump Management.
PROSTHETIC LEG PRESENTED BY:-AWAIS IJAZ HASNAT AHMED KHAN.
Chapter 10 Health-Related Fitness and Conditioning 10 Health-Related Fitness and Conditioning C H A P T E R.
Lower Limb. Sartorius Origin Anterior superior iliac spine Insertion Medial/anterior tibia (pes anserine) Action Flexes and laterally rotates the hip.
Chapter 6/7 Tibia and Fibula Distal Femur. Proximal Tibia Condyle Medial Lateral Intercondylar Eminence Tibial Plateau Tibial Tuberosity Anterior Crest.
LOOP TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
BRACE & LIMB LABORATORY. Processes of making a Transtibial prosthesis.
Preventing Injury in the Lower Leg and Ankle Achilles Tendon Stretching –A tight heel cord may limit dorsiflexion and may predispose athlete to ankle injury.
BY Parmar Anjali Singh Sweta
Chapter 42 Lower Extremity Amputation
SAFE USE OF DIATHERMY RACHEAL AFOLABI, RN, RM, H. Dip. PERI-OPERATIVE NURSING, H.Dip. HEALTH SYSTEM MANAGEMENT.
Ankle Evaluation. HI(O)PS History History Inspection/Observation Inspection/Observation Palpation Palpation Special Tests Special Tests.
Assessment of Soft Artificial Skin with Pressure Sensibility Southeastern Louisiana University.
Assessment of Soft Artificial Skin with Pressure Sensibility Southeastern Louisiana University.
Date of download: 6/23/2016 Copyright © ASME. All rights reserved. From: Optimization of Prosthetic Foot Stiffness to Reduce Metabolic Cost and Intact.
Physical Exam of the Knee
Hemostatic Compression Device Jill Doyle Reed Gioe Christopher Miller Aut Singhchinsuk.
Prosthesis in Transtibial Amputation
In and Out Line Monitoring System for Volleyball
Knee.
Date of download: 10/16/2017 Copyright © ASME. All rights reserved.
Prosthetic limbs.
Date of download: 10/25/2017 Copyright © ASME. All rights reserved.
Christine Bronikowski, Amanda Chen, Jared Mulford, Amy Ostrowski
Assessment of Soft Artificial Skin with Pressure Sensibility
Presentation transcript:

Analyzing the forces within unilateral transtibial prosthetic sockets and design of an improved force minimizing socket Christine Bronikowski, Amanda Chen, Jared Mulford, Amy Ostrowski Advisor: Aaron Fitzsimmons, The Surgical Clinic

Problem Statement Lack of research in the socket interface between the artificial limb and the residual limb, specifically force profiles ▫ Majority of research based on models with historically proven success and qualitative assessments

Current Process for Constructing a Transtibial Socket 1.Transtibial Patient Evaluation a.Limb measurements b.Skin type and integrity c.Range of motion d.Hand dexterity e.Fine and gross motor skills f.Cognition 2.Gel Liner Interface Material Selection a.Most common: Urethane, thermoplastic elastomer, silicone 3.Fit Gel Liner to Patient

Current Process for Constructing a Transtibial Socket (cont.) 4.Cast and measure over gel liner 5.Modify negative model a.Computer modeling b.Hand modification 6.Fabricate positive check socket 7.Fit positive check socket – static and dynamic assessments 8.Fit final laminated socket

Problems with Current Models ▫Skin abrasion ▫Pain or discomfort ▫Tissue breakdown at the skin surface and within deep tissues ▫Pressure ulcerations and resultant infections at the socket interface Many of these problems arise from forces at prosthetic interfaces

Project Goals Acquire accurate measurements of perpendicular forces acting on the residual limb of transtibial amputee during various movements Pinpoint regions with highest forces Design a socket system (combination of foot, liner, and socket) in which forces are optimally distributed throughout the residual limb-socket interface

Forces Acting on the Limb Shear– resulting from frictional forces between skin and socket ▫Can be minimized using socket liners Perpendicular

Method of Force Analysis Force Sensing Resistor (FSR) placed between liner and socket Very thin– will not cause variation in force determination Decrease in resistance with increasing force, which leads to increasing output voltage

Circuit Design Circuit design: current to voltage converter

Design/Safety Considerations Wire thickness ▫Thin enough to prevent interference with force data ▫Thick enough to remain durable during movement FSR-wire connection: 2 types of epoxy used ▫Needs to withstand dynamic forces within socket ▫Must be safe to place in contact with skin Power Supply ± 12 V limited to 5 V by voltage regulator

Placement of FSRs Impractical to cover every area of the residual limb with sensors Used one FSR in each area of clinical interest Pressure Sensitive (6) Fibula Head (7) Distal Tibia (8) Tibial Tubercle Pressure Tolerant (1) Tibialis Anterior (2) Distal End of Limb (3) Medial Tibial Flare (4)Mid Patella Tendon (5) Gastrocnemius

Testing Combinations 3 Sockets\Liners Urethane (Otto Bock) Silicone (Evolution) Thermoplastic Elastomer (Ohio Willow Wood) 3 Feet Each Flex-Foot & Multi-axial Ankle SACH Vertical Shank ESF Several Conditions Liner Only Standing on Normal Limb Only Standing on Both Limbs Standing on Prosthetic Limb Only Walking 2mph

Recent Work Created new LabView program to record data Calibrated each FSR Created Excel template to convert voltage readings into pressure data Tested 9 combinations of feet and liners

LabView Program

FSR Calibration

Excel Template File

Current Status Analyzing Results With Our Advisor…

Future Work Analyze results, determine regions containing peak forces Based on results, test several new sockets with Cody Make specific regions of each trial socket more flexible or rigid as needed to optimally distribute forces Design and develop final socket: provide more cushioning in areas of greatest force Determine success from patient feedback and peak force reduction in critical regions

References