W e m a k e i d e a s c o m e a l i v e 001IMP120402 For internal use only Flexibility and Precision in Peripheral Arteries 0.035” OTW Self- Expanding.

Slides:



Advertisements
Similar presentations
W e m a k e i d e a s c o m e a l i v e 001SCB For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength.
Advertisements

Engineering Terms Engineers design all structures with enough strength to withstand the force and load that will be placed upon them. Generally loads are.
NITINOL.
Metallurgy of Welding.
Heat Treatment of metals
HVACR316 - Piping Piping and Fitting.
Machine Tools And Devices For Special Technologies Plasma machining Slovak University of Technology Faculty of Material Science and Technology in Trnava.
Balloons and Wires Adam B. Greenbaum, MD Associate Director, Cardiac Cath Lab Henry Ford Heart and Vascular Institute No relationships to disclose in relation.
Subtitle Text Here Zylon Medical Devices Smaller Is Better Supported by NIH SBIR PHASE II Grant # 5 R44 H
W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Not only a peripheral stent available in Renal sizes...
Designing for Stiffness
W e m a k e i d e a s c o m e a l i v e For internal use only Covering all your needs for Fem-Pop Interventions.
Physiological effects of training The skeletal system.
Chapter 5 Ferrous Alloys.
STAINLESS STEEL PIPES. WHAT IS STAINLESS STEEL TYPICAL PROPERTIES Stainless steels are alloys containing iron, relatively low carbon, a minimum 10.5%
MECHANICAL PROPERTIES OF MATERIALS
Self-Expanding Stents VS Balloon-Expanding Stents
Manufacturing technical objects. MATERIALS To decide which materials are suitable for making technical objects, manufacturers must first determine the.
Aluminum bellows for experiments
13.4. GENERAL DESIGN CONSIDERATIONS: PRESSURE VESSELS
2 Introduction Drug-eluting stents have defined a new era in the successful treatment of coronary artery disease However, like any therapy, DES results.
Wires, Catheters & Supplimentary Equipment
1 *Report IIB(R) 27/ The CoStar Stent (Conor) was also tested but is not shown in this report as it only presents the commercially available stents.
UNIT III BULK DEFORMATION PROCESSES FUNDAMENTALS OF METAL FORMING There are four basic production processes for producing desired shape of a product. These.
Confidential: Internal Use only 1 Click to edit Master title style Click to edit Master text styles – Second level Third level – Fourth level » Fifth level.
- heating on at required temperature - dwell at temperature - cooling
Alloys.
Presented by Gokul R 7th semester Mechanical
Metallic Materials.  Types of metallic Materials * Aluminum * Brass * Bronze * Stainless Steel * Carbon Steel * Copper.
POWER TOOLS Electric drills
Mechanical Design of Process Equipment FUNDAMENTAL PRINCIPLES AND EQUATIONS Principal stresses Theories of failure
Product Training Europe July 2002
Welding Inspection and Metallurgy
Foundations of Technology Manufacturing
Renal Intervention by the Radial Approach Josef Ludwig, Erlangen Angiosoft.NET.
Featuring Bifurcation Trans-Radial Approach Technical Issues Martial Hamon Caen, France Provisionnal T stenting With the Frontier stent Main Branch Balloon.
SEMINAR ON SHAPE MEMORY ALLOYS
Design Guidelines Injection Moulding Engineering Design.
Nitinol Copyright © 2012 Board of Trustees, University of Illinois. All rights reserved.
Metals Unit 212/255 – Principles of Fabrication and Welding Technology.
MATERIAL PROCESSING: “ALL THAT IS DONE TO CONVERT STAFF TO THINGS”
Bare Metal Stent Self Expandable Stent Balloon Expandable Stent
Self-Expandable Nitinol Coronary Stent
Valvuloplasty Scoring Balloon for the Treatment of Critical Aortic Valve Stenosis - Design of a FIM Study - Gary Gershony, MD, FACC, FSCAI, FAHA, FRCPC.
William A. Gray, MD DISCLOSURES Consulting Fees
Product Specifications
Shafts and Shaft Components
Direct Flow Medical Experience with a Conformable, Repositionable, Retrievable, Percutaneous Aortic Valve Reginald Low MD University of California,Davis.
Abbott Vascular Bifurcation Program
Opti-Purge® FAST INFLATION PURGE SYSTEM
The REVA Tyrosine Polycarbonate Bioresorbable Stent: Lessons Learned and Future Directions Robert K. Schultz, PhD.
Kadziolka K, Estrade, Leautaud A., W. Mustafa, Pierot L. CHU REMIS
DES Bioabsorbable and DCB Technologies
AUH Connectors PURPOSE:
Emerson TX7 Series Thermostatic Expansion Valve.
Fanelli Laparoscopic Endobiliary Stent Suggested Instructions for Use
Chapter 5 Power Estimation in Extrusion and Wire-rod Drawing
Chapter 2 Material and Manufacturing Properties
ACHF Connectors PURPOSE:
BY SYNDICATE NO 2.
Gasket Fabricators Association Technical Committee Presentation
ACHL Connectors PURPOSE:
Mechanical Properties: 1
Initial experience with the Ventana fenestrated system for endovascular repair of juxtarenal and pararenal aortic aneurysms  Andrew Holden, MD, Renato.
NEW GENERATION STENT COBALT-CHROMIUM SIROLIMUS ELUTING STENT.
Boriding Boronizing, also known as boriding, is a case hardening diffusion process where boron atoms are diffused into the surface of a metal component.
EVAR Overview and stent-graft implantation in complex iliac anatomy
Presentation transcript:

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Flexibility and Precision in Peripheral Arteries 0.035” OTW Self- Expanding Stent System

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only The Reality of Femoral Occlusions

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only In Summary Range of diameter Range of length Usable Catheter length Guide wire compatibility Introducer compatibility Construction & design Entry profile: On-stent Tantalum markers Ø 6, 7, 8, 9, 10, 12 mm 20, 30, 40, 60, 80, 120 mm 80 cm / 120 cm 0.035”6F multisegmented design with reinforced link-elements 0.043” each end

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only The Stent

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Basics on NiTiNOL  NiTiNOL was invented 1962 by the US-Naval Ordnance Laboratory, a department of the US-Navy.  Nickel Titanium Naval Ordnance Laboratory  They were looking for a very hard, anti-magnetic and corrosion resistant material  They melted 45% Titanium and 55% Nickel, which developed the desired properties and even more.  NiTiNOL is a brand name, there are other NiTi-alloys with other names like  Sentinol, Sentalloy,...

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only What is Superelasticity?

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Properties of NiTiNOL  Superelasticity  In reality it is pseudo-elastic  if it is cooled down below  20°C, it becomes inelastic like pure Tin (Zn) so that it can be deformed in all facilities without breaking (Martensitic low temperature phase). If it is rewarmed above  20°C, it moves back in its previous shape.  Over 20°C it can be bended and twisted as desired and immediately it moves back to the old shape (Austenitic high temperature phase).  Depending on the Alloy ingredients, the conversion temperature can vary from -15°C to +80°C.

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Shape NiTiNOL  The material needs to be fixtured and constrained in the desired shape and heat-treated. Typically for superelastic material, a heat treatment in the 500°C range is adequate; the length of heat treatment varies with the equipment used for the heat treatment and the thermal mass of the shaping fixture. In a molten salt bath for example, the heat treatment time is generally between 2 and 5 minutes.

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Stent Design  Highly flexible and conformable stent platform  Laser cut, ultra-polished surfaces  Multisegmented design  well proven zigzag-Nitinol design  oversized connecting links for improved fracture resistance  Surface Quality  Ultra high polished surface  Increased corrosion resistance

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Stent Marker  Two Tantalum markers (one on each end of the stent) for enhanced visibility  High safety, because of Laser-welded markers  Unique inside oriented marker, for improved mechanical properties  Good radiopacity of the stent  Strut thickness: 0.18 mm  Strut width: 0.13 mm

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Mechanical Stent Behaviour Flexure Thin struts for high flexibilityThin struts for high flexibility Expansion Large strut width for sufficient radial strengthLarge strut width for sufficient radial strength Torsion Oversized connecting links for improved fracture resistanceOversized connecting links for improved fracture resistance Best Adaptability to the Vessel Dynamic Requirements Elongation Adequate strut dimensions, number of links and design for dynamic adaptabilityAdequate strut dimensions, number of links and design for dynamic adaptability

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Diameter dependent number of links  Number of link elements:  3 link-elements  Ø 6, 7 and 8 mm  5 link-elements  Ø 9, 10 and 12 mm  Optimized radial strength and response to different mechanical stress by the diameter specific design  Oversized connecting links for improved fracture resistance

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Shortening – a technical answer  Shortening is dependent from the nominal length & diameter of the stent!  When the stent is loaded in the delivery system, it is longer than the nominal length!  Since the proximal marker on the SDS is movable, the stent edges are clearly marked to enable a proper positioning in the lesion.  Even if the stent follows the sheath retraction for some mm, the distal markers stays always behind it.  We have measured a shortening of 3,9% in the worst case

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only The Wallstent Story This mechanical behaviour is HISTORY!

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Metal-to Artery Ratio small  large 

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Model Mix Stent Ø 6.0 mm length 20, 30, 40, 60, 80, 100, 120 mm Stent Ø 7.0 mm length 20, 30, 40, 60, 80, 100, 120 mm Stent Ø 8.0 mm length 30, 40, 60, 80, 100, 120 mm Stent Ø 9.0 mm length 30, 40, 60, 80, 100 mm Stent Ø 10.0 mm length 30, 40, 60, 80, 100 mm Stent Ø 12.0 mm length 30, 40, 60, 80 mm Usable Shaft Length: 80 cm and 120 cm Stent Ø := unconstrained stent diameter length := nominal unconstrained diameter

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only The Stent Delivery System

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only SDS Construction  OTW  0.035” guide wire compatible  Standard guidewire size, 0.018” is more exotic  6F shaft  General accepted size for peripheral interventions  80 and 120 cm usable shaft length  Suitable for antegrade or contralateral approaches  Delivery by holding the stainless steel tube in place and sliding back the Y-piece with Tuohy-Borst Valve  Straight forward technique  Tuohy-Borst Valve, better known as variable hemostatic valve

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Radiopaque Markers on SDS  Proximal marker (1)  Proximal marker acts as the pusher to maintain the stent in place when the outer tube is retracted and the stent is deployed.  Distal marker is integrated in the outer tube (2)  Tip material is radiopaque (mixed with Barium Sulfate) (3) (1)(2)(3)

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only SDS Sheath Construction  Full length braided sheath design  This reinforcement combines pushability and flexibility to enable easy negotiation in tortuous anatomies without kinking  ideal balance for successful contra-lateral approaches  PTFE coating inside the sheath  Reduction of friction between sheath and stent for a gradual, controlled and safe deployment of the stent in the lesion

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Tip Construction / Entry Profile  New Tip design entry profile of 0,043 “ (1.10 mm),  Tip composed of a corrugated tube and a radiopaque overmoulded tube  NEW: edges were rounded to avoid entrapment during retrieval NEW: security seal between white overmoulded tip and blue inner tube.

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only The Pull-Back-Handle  We have chosen the KISS approach! Keep It Simple & Safe  Delivery by sliding back the Y-piece with Tuohy-Borst Valve while holding the stainless steel tube in place  After flushing the inner lumen of the sheath through the side port…  With one hand keep the steel tube in position, with the other hand slide back the Y-piece  It is not a “Black-Box” Handle You see - what you get/do!

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Stent Positioning  Controlled, precise positioning  minimal shortening to obtain an adequate lesion coverage  PTFE inner shaft coating for low-friction stent deployment  low compliant core-tube for direct transition from pull-back handle to sheath retraction

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Product Features  Excellent Flexibility of the Stent Platform and the Delivery System  Inside shaft Teflon-liner for low friction deployment  Optimal balance of flexibility, radial force and strut fracture resistance  Diameter dependent design  Ø 6, 7, 8 mm - 3 links  Ø 9, 10, 12 mm - 5 links  Atraumatic, kink-resistant tip design  Braided outer catheter shaft with Pull-Back Handle

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Clinical Data StudyMARISABSOLTERESILENTFAST StentMarisDynalink+AbsoluteLifeStentLuminexx Mean stented length (mm) 119,8 ± 83,31132±7199.2± (lesion length) 12 month primary patency 81.4% (X-ray)63% (DUS)80% (DUS)68% (DUS)