Total Hydronic Balancing

Slides:



Advertisements
Similar presentations
DuraDrive VBB/VBS Series Ball Valves and Actuators
Advertisements

Refrigeration Systems
Packaged Terminal Air Conditioners
HVAC 11a CNST 305 Environmental Systems 1 Dr. Berryman
Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
Customer Service – International dept. STAR 24 3 E.
“Enerpak” Units » Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners,
Thermostats, Pressure Switches, and Other Electric Control Devices
Objectives Control Terminology Types of controllers –Differences Controls in the real world –Problems –Response time vs. stability.
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
 Established in 1995  Located in Wilmington, NC with a 40,000 Sqft facility.  Specializes in the design and manufacturing of connection solutions. 
CV2000LS – Post Compensated Valve CV2000LS Post Pressure Compensated Flow Sharing Valve.
HVACR316 - Piping Piping and Fitting.
Using Copper Water Loop Heat Pipes to Efficiently Cool CPUs and GPUs Stephen Fried President Passive Thermal Technology, Inc.
737 PNEUMATICS MENU PRINCIPAL.
Engineered Products Make-Up Air for Heating and Cooling.
Presentation of product. Production capacity New heater For 15 years VTS Clima Group has been a leader in industrial heating engineering. Volcano VR.
Engineer Presentation
Welcome to the HYCOA Solution
Skilled Trades 1201 Residential Plumbing.
Actuators.
Sand media filtration is one of the oldest filter processes in the world. Water Tool Modular Filters have made extensive improvements to what is presently.
CONTROL VALVE - THEORY & SIZING
8/10/20151 THE BASICS OF INFRATECH HEATER CONTROLS.
STEAM HEATING.
Hydronic Mechanical Controls
Lecture Objectives: Learn about automatic control Use life-cycle cost analysis integrated in eQUEST.
Hydronic Balancing „Cocon Q “ Pressure independent dynamic control valve.
Air-Source Heat Pumps I North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed. Airsource Heat Pump 1.
Steam System Operation and Distribution System Optimization Affordable Comfort National 2013 Denver, Colorado.
HVAC523 Circulator Pumps.
HVAC523 Basic Subsystems.
Unit 208: Central heating systems
Temperature Control Loop
2010.
HVAC523 Piping and Fittings.
Ejector with Pad ZHP Series Confidential Internal use onlyConfidentialConfidential.
Introduction to Energy Management. Week/Lesson 11 Control Systems for Occupant Comfort.
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Direct Hot Water. What Cold Water System is Pictured? What hot Water System is Pictured?
Series Loop Concept Adv Dis.
Esbe Rotary Motorized valves The ESBE Rotary Motorized valves (mixing valves and actuators) are used to control heating and cooling in buildings. We offer.
Water Heaters 101 Residential Gas and Electric. Outline Basic water heater features Residential gas overview Residential electric overview Q&A.
B26 The AsyMatrix Condenser for Heat Pumps Powerful, just smaller.
BASIC AUTOMATIC CONTROLS UNIT 16 ADVANCED AUTOMATIC CONTROLS
Boiler Energy Saver Advanced Boiler Controls. Most boiler controls at present consist of a switch!
EMERGING TECHNOLOGIES AVAILABLE TO REDUCE COMPRESSED AIR DEMAND Double Acting Air Cylinder Double Acting Air Cylinder Air Operated Diaphragm Pumps Air.
MENU PRINCIPAL. THIS PRESENTATION INCLUDES THE SOURCES OF AIR, THE MAJOR SYSTEM COMPONENTS AND THE WAY THE CONTROLS AND INDICATORS ARE USED TO OPERATE.
“Beyond the loop layout”.  Jeremy Neven, C.B.C.O. ◦ Chief Building Official ◦ Plumber ◦ HVAC Designer ◦
UniTrane™ Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line
Under floor heating Designing underfloor heating (UFH) system must always comply with the system suppliers instructions.
Fan Coil Controller FC/S 1.1
Grotherm Thermostatic Rough-in Valve
AUTOMOTIVE COOLING SYSTEMS
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
© Copyright, HQT-SV Control System
Asahi/America Electric Actuators Series 94.
Outcome 1 (part 1) Types of domestic central heating systems installed in domestic dwellings Unit 208: Central heating systems.
HBLT-wire Product Introduction September 21, 2018.
منطقه چهار عمليات انتقال گاز عمليات بهره برداري خطوط لوله گاز
Customer Presentation
Asahi/America Electric Actuators Series 94.
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
SCITEQ End closure series
Presentation transcript:

Total Hydronic Balancing 11.04.2017 Valves + Systems Total Hydronic Balancing Comfort and Energy Savings for Heating and Cooling Systems

German Engineered Quality and Value Hydronic Balancing 11.04.2017 Valves + Systems German Engineered Quality and Value Application Guides Electrothermal Actuators Non Electric Actuators Pressure Activated Bypass Zone Valves Distribution Stations Balancing Valves Thermostatic Radiator Valves Diverting and Mixing Valves

Energy Saving Integrated Packages Hydronic Balancing 11.04.2017 Products and Applications Energy Saving Integrated Packages Mechanical Systems for the 21st Century Energy Efficient Hydronic Heating & Cooling Balancing Energy Solar Energy Award Winning Quality and Value Administration Building in Melbourne, Australia European Parliament In Strasbourg, France

Oventrop‘s Profile Founded in 1851 Owned by the same family today Hydronic Balancing 11.04.2017 Oventrop‘s Profile Founded in 1851 Owned by the same family today Quality engineering and manufacturing Products distributed all over the world 8 Sub Corporations Oventrop Corporation US Since 2004 East Granby, CT USA Main factory in Olsberg, Germany Production Facility in Brilon

Awards for Excellence Good design means Hydronic Balancing 11.04.2017 Design Awards Awards for Excellence Good design means excellent quality and good value North Rhine Westfalia Industrial Forum Design Hannover Design Centre Essen German Institute for Copper Berlin Pragotherm Prague Design Laboratory Hamburg Design Museum London

Oventrop Radiator Valves and Thermostatic Operators Hydronic Balancing 11.04.2017 Oventrop Radiator Valves and Thermostatic Operators Unique and Quality Components

Oventrop Radiator Valves and Thermostatic Operators Hydronic Balancing 11.04.2017 Oventrop Radiator Valves and Thermostatic Operators Liquid Filled Diaphram Thermostatic Operator Radiator Valve Valve Insert

Oventrop Radiator Valves and Thermostatic Operators Hydronic Balancing 11.04.2017 Oventrop Radiator Valves and Thermostatic Operators Liquid filled diaphram hand calibrated Expand- Close Contract- Open connection Thermostat Connection M30 x 1.5 Radiator Valve Closed- no flow Open- modulating flow

Oventrop Radiator Valves and Thermostatic Operators Hydronic Balancing 11.04.2017 Oventrop Radiator Valves and Thermostatic Operators Thermostatic Operators Standard model Uni XH and Uni XD Appearance Uni LH Compact Vindo Slow Reaction Uni DH Exclusive Uni SH Lockshield Uni LBH Electronic R-Tronic Remote Control Uni FH and Uni FD

Radiator Valve Thermostats Hydronic Balancing 11.04.2017 Radiator Valve Thermostats Modulating Thermostat Control with liquid sensor Thermostat Uni XH threaded model For Oventrop radiator valves M 30 x 1.5 threaded valves M 30 x 1.0 threaded valves Thermostat Uni XD squeeze on model for Danfoss valves and Buderus panel radiators Series RA squeeze connections Temperature setting may be limited or locked 0 setting = positive off X setting = freeze protection Temperature range 42 - 84ºF #3 setting = 68º ºF with remote sensor 6 1/2 ft. or 16 ft.

Thermostats 3 = 68ºF Collar nut Settings Base Numbers Hydronic Balancing 11.04.2017 Thermostats High/Low Temp Guides Collar nut Settings Base Numbers represents 8ºF each increment Minor Graduations represents 1.8ºF Setting 3, 68ºF Memory Disc 1 = 53ºF 2 = 60ºF 3 = 68ºF 4 = 75ºF 5 = 82ºF 0 = complete shut off found on thermostats with symbol  = Frost protection symbol, valve opens automatically when room reaches 44

Radiator Valve Thermostats Hydronic Balancing 11.04.2017 Radiator Valve Thermostats Modulating Thermostat Control with liquid sensor Thermostat Uni LH For Oventrop radiator valves M 30 x 1.5 threaded valves M 30 x 1.0 threaded valves Sleek appearance Hidden Locks for min/max settings adjustable only by removing ring requires ring removal tool to set locks Powder White or Chrome for Series E Radiator Valves

Radiator Valve Thermostats Hydronic Balancing 11.04.2017 Radiator Valve Thermostats Modulating Thermostat Control with liquid sensor Thermostat Vindo M 30 x 1.5 threaded or Squeeze connection Sleek appearance Economical Benefits Compact lockable limitable

Radiator Valve Thermostats Hydronic Balancing 11.04.2017 Radiator Valve Thermostats Thermostat Uni DH M 30 x 1.5 threaded valve Best for slow reaction time Great for steam applications Thermostat with wax Sensor Temperature setting may be limited or locked. Wax filled sensor reacts slower than liquid filled sensors Good Match for Steam Systems with remote sensor 6 1/2 ft.

Radiator Valve Thermostats Hydronic Balancing 11.04.2017 Radiator Valve Thermostats Modulating Thermostat Control with liquid sensor Thermostat Uni SH M 30 x 1.5 threaded valve Match with Series E Radiator Valves Perfect thermostat for towel bars Sleek appearance Chrome or White Ring

Radiator Valve Thermostats Hydronic Balancing 11.04.2017 Radiator Valve Thermostats Modulating Thermostat Control with liquid sensor Thermostat Uni LHB For Oventrop radiator valves M 30 x 1.5 threaded valves M 30 x 1.0 threaded valve Lockshield Configuration Integrated anti-theft Device Increased Flextional Strength Accessory: Setting Key to set the nominal temperature value at the thermostat

Radiator Valve Thermostats Hydronic Balancing 11.04.2017 Radiator Valve Thermostats Electronic Radiator Control R-Tronic Programmable electronic controller for individual room For Oventrop radiator valves M 30 x 1.5 threaded valves Adjustable Timed program Battery operated Child-proof lock, frost protection Auto-off with open window function Temperature range: 41 - 86 °F

Radiator Valve Thermostats Hydronic Balancing 11.04.2017 Radiator Valve Thermostats Thermostats with Remote Control Thermostat Uni FH white model For Oventrop radiator valves M 30 x 1.5 threaded valves 6 1/2 ft. capillary 16 ft. capillary 33 ft capillary Thermostat Uni FD white model squeeze on connection for Danfoss valves and Buderus panel radiators Series RA squeeze connections 6 1/2 ft. capillary Wall thermostats are better for control of comfort and ease of adjustment Radiators that are placed within enclosures need a remote thermostat to eliminate undue cycling

Radiator Valve Thermostats Hydronic Balancing 11.04.2017 Radiator Valve Thermostats Thermostats with Remote Control and remote sensor Thermostat Uni LH white model with remote sensor M 30 x 1.5 threaded valves 6 1/2 ft. capillary 16 ft. capillary Remote sensor allows for average temperature reading at sensor and wall thermostat Wall thermostats are better for control of comfort and ease of adjustment Radiators that are placed within enclosures need a remote thermostat to eliminate undue cycling

Hot Water Valves for Thermostats Radiator Valve Hydronic Balancing 11.04.2017 Valves for Thermostats Series AZ Hot Water Radiator Valve M 30 x 1.5 threaded 30mm diameter 1.5 thread pitch brass, nickel plated highest Cv at 1.28 These valves can be used with 4 types of actuators 1. Manual adjuster (included) 2. Thermostatic (non-electric) 3. Thermostatic remote capillary (non-electric) 4. 24 V electric for on/off control

Valves for Thermostats Hydronic Balancing 11.04.2017 Valves for Thermostats Series AZ Manual adjuster Valve Patterns Angle Pattern Valve Sizes: 1/2, 3/4, 1, 1-1/4 inch Straight Pattern Valve Sizes: 1/2, 3/4, 1, 1-1/4 inch Reverse Angle Pattern Angle Sizes: 1/2, 3/4 inch

Valves for Thermostats Hydronic Balancing 11.04.2017 Valves for Thermostats Series AZ Valve Patterns Double Angle Pattern: Thermostat extends from valve forward horizontally Double Angle Pattern Left 1/2 inch Double Angle Pattern Right 1/2 inch

Valves for Thermostats Service Valves for Return Side of Radiator Hydronic Balancing 11.04.2017 Valves for Thermostats Service Valves for Return Side of Radiator Combi 2 Balancing and shut off NPT x NPT SWT x SWT Sizes in 1/2 and 3/4 inch Combi 4 Balancing with memory, filling, draining, and shut off Combi 2 Combi 4 Nickel Plated Angle and Straight Pattern

Hydronic Balancing 11.04.2017

Hydronic Balancing 11.04.2017

Hydronic Balancing 11.04.2017

Thermostatic operator with wall thermostat and remote sensor Hydronic Balancing 11.04.2017 Thermostatic operator with wall thermostat and remote sensor

Valves for Thermostats Hydronic Balancing 11.04.2017 Valves for Thermostats Exclusive Designer Series E Radiator Valve Series E M 30 x 1.5 threaded angle or straight pattern chrome or white Perfect for towel bar warmers Include return side Service valve Combi E for radiator or towel rack matching appearance isolating, balancing fill and drain Available in 1/2 inch

Valves for Thermostats Hydronic Balancing 11.04.2017 Valves for Thermostats Thermostat location Series E Valve Patterns 1/2 inch valves Angle Pattern Valve Double Angle Pattern Right Straight Pattern Valve Double Angle Pattern Left

Valves for Thermostats Hydronic Balancing 11.04.2017 Valves for Thermostats Return Side Service Valve Combi E Valve Patterns 1/2 inch valves Angle Pattern Valve Straight Pattern Valve

Steam Valves for Thermostats Radiator Valve Hydronic Balancing 11.04.2017 Valves for Thermostats Series S for low pressure steam max. 15 psi Steam Radiator Valve Includes Stainless Steel Cartridge long service life Competitors such as Danfoss use EPDM valve seats for both hot water and steam radiators valves. Steam and high temperatures corrode EPDM over time. A Stainless Steel valve insert should be used in steam systems.

Valves for Thermostats Hydronic Balancing 11.04.2017 Valves for Thermostats Series S (Steam) Valve Patterns Angle Pattern Valve Sizes: 1/2, 3/4, 1, 1-1/4 inch Straight Pattern Valve Sizes: 1/2, 3/4, 1, 1-1/4 inch Reverse Angle Pattern Angle Sizes: 1/2, 3/4 inch

Steam Valves for Thermostats Radiator Valve One-pipe Steam Hydronic Balancing 11.04.2017 Valves for Thermostats One-pipe Steam airvent port Steam Radiator Valve Includes Stainless Steel Cartridge long service life Room Thermostat Control for a one pipe steam radiator systems The 1/8 inch air vent on a one pipe steam radiator can be removed and replaced with a one pipe steam radiator valve The air vent is reinstalled vertically into the one pipe radiator valve.

One Pipe Steam Radiator Valve and Thermostat Hydronic Balancing 11.04.2017 Oventrop Radiator Valves One Pipe Steam Radiator Valve and Thermostat Air vent 1/8 inch NPT into radiator vent Oventrop One-pipe Steam with wax sensor Thermostat UNI DH

Convert One Pipe Steam to Hot Water Hydronic Balancing 11.04.2017 Valves for Thermostats Convert One Pipe Steam to Hot Water One Pipe Radiator Injection Valves 1/2 inch to radiator 1/2 copper or pex Verticle insertion tube Horizontal insertion tube most popular Extend injection water tube into radiator with copper or pex tubing Cut in an airvent at top of radiator when converting radiator

One Pipe Radiator Injection Valve with constant bypass and shut off Hydronic Balancing 11.04.2017 Oventrop Radiator Valves One Pipe Radiator Injection Valve with constant bypass and shut off Cut in radiator vent Convert steam radiator to two pipe hot water

Muliflex Fittings for integrated panel radiators Hydronic Balancing 11.04.2017 Panel Radiator Valves Muliflex Fittings for integrated panel radiators Designed for Buderus panel radiators DiaNorm panel radiators Uni XH with trim piece Multiflex Vindo Pipes only through floor at one end No TRV body seen only the connector below the rad and the head on the side TBOE is the recommended connection method for rads to achieve the most efficient output. Rad has internal baffles to get the best flow path R 20 connections Multiflex fitting

Panel Radiator Valves Diverter Valves for one pipe systems Hydronic Balancing 11.04.2017 Panel Radiator Valves Multiflex fittings Diverter Valves for one pipe systems for series loop systems radiators piped in series Connection 1/2 x 3/4 inch thread 90 degree angle straight pass

Panel Radiator Valves 2- pipe systems isolating valves Hydronic Balancing 11.04.2017 Panel Radiator Valves 2- pipe systems isolating valves pipe radiators in parallel Multiflex fittings Connection 1/2 x 3/4 inch thread 90 degree angle straight pass Compression Fittings for Multiflex Transition to Pex or Copper

Vandal Guard Protects from thermostat removal Hydronic Balancing 11.04.2017 Assessories Vandal Guard Protects from thermostat removal Right Angle Adapter for threaded and squeeze connection

Function: Cv value : Application: Valve Inserts Hydronic Balancing 11.04.2017 Valve Inserts Insert Type "AZ" Function: Standard valve insert with hot water valves. This valve insert has the highest Cv of all inserts. Cv value : 1.28 Application: Standard for most radiator valve applications 41

Function: Cv value : Application: Valve Inserts Hydronic Balancing 11.04.2017 Valve Inserts Insert Type "AV 6" Key for flow rate setting AV 6 inserts Function: Adjustable Cv value insert, allows technician to balance flow rate with six different settings. Cv value : 0.75 Application: This insert is used where radiator return balancing can not be used. 42

Function: Cv value : Application: Valve Inserts Hydronic Balancing 11.04.2017 Valve Inserts Insert Type "ADV 6" Landlord model Key for flow rate setting AV 6 inserts Function: Adjustable Cv value insert with six settings. If thermostat is removed from the valve the flow will be restricted to 5% of normal flow. Cv value : 0.75 Application: This insert is used where radiator return balancing can not be used and vandalism is an issue. 43

Function: Cv value : Application: Valve Inserts Hydronic Balancing 11.04.2017 Valve Inserts Insert Type "Stainless Steel Seat" Function: This insert has a stainless steel valve seat for steam applications. Cv value : 0.70 Application: This insert is used for steam applications. 44

Function: Cv value : Application: Valve Inserts Hydronic Balancing 11.04.2017 Valve Inserts Insert Type "Special" Function: This insert has a low Cv value. Cv value : 0.52 Application: The low Cv value is used to correct reversed supply and return hookup. 45

Function: Cv value: Application: Valve Inserts Hydronic Balancing 11.04.2017 Valve Inserts Insert Type "TM" Function: This insert is has a maximum pressure differential of up to 40 psi. Cv value: 1/2 inch- 1.1 3/4 inch- 1.2 1 inch- 1.3 1-1/4 inch- 1.6 Application: Used for commercial baseboard applications. 46

Hydronic Balancing 11.04.2017 Demo-Bloc Special tool for replacing Oventrop valve inserts under working conditions Demo-Bloc Radiator valve drain port Step 1: screw demo-bloc into radiator valve Step 2: remove valve insert with demo-bloc stem handle, open drain port for stem handle retraction Step 3: close demo-bloc ball valve, remove stem with attached valve insert, remove valve insert Valve insert Step 4: Install new valve stem back into radiator valve, remove demo-bloc

Valves for Thermostats Hydronic Balancing 11.04.2017 Valves for Thermostats Custom to US market Zone / Radiator Valves 1/2” and 3/4” SWT x SWT Angle Pattern Straight Pattern Reverse angle pattern #1 selling non electric valve for baseboard control Application Non electric Baseboard control

Valves for Thermostats Zone / Radiator Valves Valve Patterns Angle Pattern Valve Sizes: 1/2, 3/4 inch Straight Pattern Valve Sizes: 1/2, 3/4 inch Reverse Angle Pattern Angle Sizes: 1/2, 3/4 inch

Non Electric Wall Thermostats Hydronic Balancing 11.04.2017 Non Electric Wall Thermostats Thermostat Uni LH 6 1/2 ft. capillary 16 ft. capillary 33 ft capillary Application Non electric baseboard control Wall Thermostat For ease and convenient control

Oventrop Actuators Application 24VAC zone valve model zone valves Hydronic Balancing 11.04.2017 Oventrop Actuators 24VAC zone valve model 2 models with normally open actuator with normally closed actuator Application zone valves baseboards Proportional Temperature Control 0 - 10 v proportional signal actuator Better temperature control Comes separately

Electrothermal Actuators 24VAC on/off Models: 1 - Normally closed, with end switch 2 - Normally closed 3 - Normally open M30x1.5 threads standard Slow acting to prevent water hammer Low profile, compact design 24V, 2 watt Adapter for M30x1.0 threads For use with: Diverting valve Radiator valves Manifolds

Electromotive Actuators Proportional Actuator 24 VAC Proportional actuator for temperature mixing and flow control For use with: Three-way mixing valve Radiator valves Manifolds 0 – 10v input signal

Valve Thermostats Non-electric actuator Proportional Regulator Non-electric actuator with strap on sensor and transfer unit. For use with two- and three-way valves. The control range may be limited and locked. Connection thread M 30 x 1.5 Handwheel scale 1 2 3 4 5 6 7 Temperature setting in F 86 95 104 113 122 131 140

Oventrop Zone Valve 24 VAC Zone Valve 24 VAC to open 2 wire actuator Hydronic Balancing 11.04.2017 Oventrop Zone Valve 24 VAC Zone Valve 24 VAC to open 2 wire actuator with manual lever 3.3 CV value Zone valve motor can be attached to M30 x 1.5 Oventrop radiator valve

Oventrop Balancing Valves Hydronic Balancing 11.04.2017 Great Hydronic Balancing Energy Savings and Indoor Comfort Oventrop Balancing Valves Maximize energy savings and attain a comfortable indoor climate with a comprehensive approach to balanced water flow. The flow of energy through a hydronic system must be balanced to optimize comfort and increase the efficiency of the HVAC system. Oventrop high quality balancing valves are an essential element of the total hydronic heating or cooling system.