Luminescence Dissolved Oxygen

Slides:



Advertisements
Similar presentations
O2X – Dissolved Oxygen Meter
Advertisements

Revolutionary Technology in pH Measurement
Mark Ledger MD Agua Africa Mark Titus Product Manager HACH.
Electromagnetic Radiation Cont…. Lecture 3. Dispersion of Radiation If we look carefully at the equation n i = c/v i and remember that the speed of radiation.
(PLEASE SWITCH TO THE SLIDE SHOW MODE)
IC Controls 855 & 802 ppm Dissolved Oxygen System pH / ORP Conductivity Dissolved Oxygen Chlorine Standards R1.0 © 2004 IC CONTROLS.
3.2 More about photo electricity The easiest electrons to eject are on the metals surface And will have maximum kinetic energy Other electrons need more.
An Introduction to Flame Atomic Absorption Spectrometry (FAAS) Steve Badger and Charity Wessel.
MAX PLANCK PHOTOELECTRIC EFFECT © John Parkinson.
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
Flame photometry.
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Edward C. Craig, Ph.D.* Cary B. Jackson, Ph.D. Christopher P. Fair
Dissolved Oxygen and Biochemical Oxygen Demand Analyses
IC Controls 865 ppb Dissolved Oxygen System pH / ORP Conductivity Dissolved Oxygen Chlorine Standards ppb Galvanic Dissolved Oxygen.
Measurement of Dissolved Oxygen with a Luminescence-based Oxygen Quenching Sensor By Cary B. Jackson, Ph.D. Hach Company.
Fundamental Techniques and Measurements  Mass Measurements  Volume Measurements  Preparation of a solution of known concentration  UV-Visible Spectrophotometer.
Fundamental Techniques and Measurements
Advanced Higher Chemistry Unit 1 Spectroscopy. Spectroscopy  Spectroscopy is used to give information regarding the structure of atoms or molecules.
ATOMIC ABSORPTION SPECTROSCOPY
Lesson 2. Galvanic Cells In the reaction between Zn and CuSO 4, the zinc is oxidized by copper (II) ions. Zn 0 (s) + Cu 2+ (aq) + SO 4 2-  Cu 0 (s) +
Spectroscopy (continued) Last time we discussed what spectroscopy was, and how we could use the interaction of light with atoms and molecules to measure.
F L U O F L U O R O P R O B E ® O P R O B E ®. FLUOROPROBE ® –What is Fluorescence? The ability to absorb light at one wavelength (blue) and then to emit.
South Fork Instruments Advances in pH/ORP Measurement – Polymeric Sensors Presented by John Daly South Fork Instruments.
COLORIMETRYCOLORIMETRY Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit Note: A printed description of.
Atomic Emission Spectroscopy
Flame Photometry Flame atomic emission spectrometry
1 Chapter 2 Electic-ight conversion. 2 p-n junction We insert atoms of another material (called dopants) into a semiconductor so that either a majority.
Atomic Absorption Spectrophotometer
Electrons Inside The Atom Ionization and Excitation Franck-Hertz Experiment Energy Levels and Spectra Photoelectric Effect.
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze: Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS Detection.
Flame Photometry The principles.
Technische Universität München Laboratory Experiments using Low Energy Electron Beams with some Emphasis on Water Vapor Quenching A. Ulrich, T. Heindl,
Colorimetry & Spectrophotometry.
The contribution from The contribution from photoluminescence (PL) Gordon Davies, King’s College London.
Fluorometric determination of riboflavin
Fluorometric determination of riboflavin. Introduction.
Fluorometric Analysis
Electrochemical Methods Dr M.Afroz Bakht. Potentiometry Potentiometry is a method of analysis used in the determination of concentration of ions or substances.
Chapter 15 Molecular Luminescence Spectrometry Three types of Luminescence methods are: (i) molecular fluorescence (ii) phosphorescence (iii) chemiluminescence.
Spectrofuorometer lab. 1. Fluorescence spectroscopy or (spectrofluorometry) Is a type of electromagnetic spectroscopy which analyzes fluorescence from.
Colorimeters or photometers
Oxygen Permeation Measurements Across Films using OxySense® luminescence Technology Devinder Saini OxySense Inc S. Eastern Ave Suite 14G Las Vegas,
Fluorimetric Analysis. Absorption of energy Emission of energy Spectroscopy.
Free Residual Chlorine Measurement
SPECTROPHOTOMETRY PRACTICAL 213 PHC INSTUMENTAL ANALYSIS.
Fluorescence spectroscopy, Einstein’s coefficients Consider a molecule with two energy levels S a and S b The rate of transition.
Detection Circuit ENGR Pre Lab.
UV SPECTROSCOPY Absorption spectra.
Chapter 16.  the chemical principles, half-equations and overall equations of simple electrolytic cells; comparison of electrolytic cells using molten.
Fluorometric determination of riboflavin
1 Molecular Luminescence Spectroscopy Lecture 29.
Atomic Absorption Spectroscopy.  Qualitative test for metals in solution  Can also be used for coloured lights  This emission of light is called an.
Life always offers you a second chance. It’s called tomorrow.
Light Sources. Luminescent materials Luminescent materials ~materials that glow when they get excited. ex. most metals, certain gases (neon) Artificial.
Tel: +44 (0) Dissolved Oxygen.
1© Manhattan Press (H.K.) Ltd Continuous spectra Spectra Sun’s spectrum and Fraunhofer lines.
Molecular Fluorescence Spectroscopy
SPECTROFLUORIMETRY Prepared By: HIMANSHU SHARA 2010B2A2196P.
VisiPro™ DO Ex First optical DO sensor with ATEX approval
UV/VIS SPECTROSCOPY.
Colorimeters or photometers
Fundamental Techniques and Measurements
Rapid Lab Systems measuring principle
Colorimeters OR photometers
Warm Up Write your responses in your binder:
Fundamental Techniques and Measurements
Optical Properties (광학적 성질)
Spectroscopy Uses emission and absorption of light by electrons moving between ground and excited state configuration, hence electronic configuration.
AQT90 FLEX Service Training
Presentation transcript:

Luminescence Dissolved Oxygen Lange LDO™ Sensor What does LDO means? Luminescence Dissolved Oxygen an optical and unique way (patent pending) of measuring Dissolved Oxygen eliminates nearly all disadvantages of traditional electro chemical DO measurement

Lange LDO™ Sensor How does it look like? Photo diode red LED blue LED Sensor body Sensor cap Luminophor blue LED red LED Photo diode

Lange LDO™ Sensor How does it works? Sensor Sensor- cap Luminescence indicator- molekules Sensor- cap Sensor The sensorcap is coated with a luminescent polymer. For the measurement the blue LED emits a pulse of light. This passes through the transparent carrier material and transfers part of its radiation energy to this material. Electrons from the luminophore are in this way raised from their initial energy state to a higher energy level.

Lange LDO™ Sensor How does it works? Sensor Sensor- cap Luminescence indicator- molekules Sensor- cap Sensor The electrons return to the initial state via a number of intermediate levels (within ms) The energy difference is emitted as a red radiation. This light is detected by a photo diode.

Lange LDO™ Sensor How does it works? Incident blue light Membrane Photodiode LED Incident blue light Emitted red light Sensor cap with O2-selective fluorescing molecules The intensity of the residual red light is proportional to oxygen concentration Oxygen from sample

Lange LDO™ Sensor How does it works? If oxygen molecules are now in contact with the luminophore, these are able to absorb the energy of the electrons in higher energy levels and make it possible for the electrons to return to their initial state without the emission of radiation. increasing oxygen concentration results in a reduction of the intensity of the red radiation emitted. this causes vibrations in the luminophore, result in electrons leaving the higher energy level more quickly The lifetime of the red radiation emitted is thus shortened.

Lange LDO™ Sensor How does it works? Both aspects are covered by the term quenching. Their effects are shown next page: the pulse of light sent out by the blue LED at time t=0 is incident on the luminophore that then emits red light immediately afterwards. Maximum intensity (Imax) and the decay time for the red radiation are dependent on the surrounding oxygen concentration (the decay time t is defined here are the time between excitation and reduction in the red radiation to 1/e times the maximum intensity). Intensity curve for blue radiation producing excitation and red radiation emitted. To determine the oxygen concentration the life t of the red radiation is analysed. In this way the oxygen measurement is reduced to a purely physical measurement of the time.

Lange LDO™ Sensor t1 t2 How does it works? Sensor cap Luminophor Normed Intensity Exitation puls Sensor cap LED Photo Diode s Emisson profile without O2 t1 with O2 t2 Time [µs] Oxygen Luminophor

„Lifetime of Luminescense“ Lange LDO™ Sensor How does it works? The LDO technology reduces the oxygen measurement to a pure time measuement - the „Lifetime of Luminescense“

Lange LDO™ Sensor How does it works? Sensor cap A red LED is also present in the sensor The red LED acts as an internal standard (or reference) for a comparison to the red light given off by the luminescent coating. Between flashes of the blue LED a red LED of known intensity is flashed on the sensor element. Sensor cap LED Photo Diode

Customer benefits Lange LDO™

Key features of Lange LDO™ Sales arguments for Lange LDO™ No calibration required Stable measurement results Independent from flow rate Reduced cleaning frequency Low maintenance efforts Without interference's No more poisoning of the sensor Short response time No polarisation time Two year warranty on sensor cap

No calibration required Sales arguments for Lange LDO™ Lange LDO™ sensor is very stable as it does not change it’s relevant characteristics ! No anode to consume and no electrolyte to deplete  extremely stable measurements Adjustment of the whole optics due to an internal standard (red LED) Each Lange LDO™ sensor cap is factory calibrated Background:  With Lange LDO™ the customer has not to calibrate his DO system anymore!

Stable measurement results Sales arguments for Lange LDO™ Background: - Lange LDO™ technology means no chemical inter action between the sample and the sensor element - Constant adjustment of all optical parts due to an internal standard (red LED)  With Lange LDO™ the DO measurement results are stable over a longer period of time and thus more reliable

Independent from flow rate Sales arguments for Lange LDO™ Background: - Electro chemical DO meters consume Oxygen during the measurement  Constant need for fresh sample and therefore a min. flow rate required - Lange LDO™ doesn’t consume DO. It requires the presence of a representative DO concentration at the sensor element only  No flow rate required

Reduced cleaning frequency Sales arguments for Lange LDO™ Background: - No DO consumption during the measurement - DO has not to diffuse through a membrane - DO must only be in contact with the luminescent coating on the sensor cap  Dirt has not the same negative influence with the optical method as with the conventional DO sensors

Low maintenance efforts Sales arguments for Lange LDO™ Background:  Only a sensor cap has to be exchanged once every two years : screw on / screw off No membrane to replace No more stretching of Teflon (very old procedure) and worrying about air bubbles No electrolyte to foul or poison No H2S poisoning of the electrolyte No more punctured membranes No more electrolyte depletion No anode or cathode No more coating of electrodes No cleaning of anodes

Without interference's Sales arguments for Lange LDO™ Background: - The Lange LDO™ principle is selective to oxygen only.  No interference with pH swings, waste water chemicals or heavy metals like open galvanic cells  Lange LDO™ is superior compared to (self cleaning) open galvanic DO cells as there are no interference’s

No more poisoning of the sensor Sales arguments for Lange LDO™ Background: - Lange LDO™ principle is not based on a chemical inter action between the sample and the sensor element - Lange LDO™ has been tested to a broad range of other chemicals. The sensor element is not affected by these (see data sheet)  Lange LDO™ can measure reliable even in difficult applications

Short response time Sales arguments for Lange LDO™ Background: - With the optical measuring principle DO only has to be present in front of the sensor element and not to diffuse through a thick (50 µm) Teflon membrane.  Short response time can be programmed (t90 < 30 s) for high dynamic processes

 Switch the instrument on and start measuring! No polarization time Sales arguments for Lange LDO™ Background: - Lange LDO™ is based on a new, optical technology. This technology does not need any “warm-up”. It is ready for use immediately.  Switch the instrument on and start measuring!