LIMITS OF DETECTION OF AN TOTAL REFLECTION SYSTEM WITH DOUBLE REFLECTION MODULE V. F. Nascimento Filho 1,2, V. H. Poblete 3 P., P. S. Parreira 1,4, E.

Slides:



Advertisements
Similar presentations
VIRGÍLIO F. NASCIMENTO FILHO Departamento de Ciências Exatas/ESALQ
Advertisements

LIMITS OF DETECTION OF AN TOTAL REFLECTION SYSTEM WITH DOUBLE REFLECTION MODULE V. F. Nascimento Filho 1,2, V. H. Poblete 3 P., P. S. Parreira 1,4, E.
Solution Concentration Read 281 – 283. Try questions 1 – 8 (show work) Concentration = quantity of solute quantity of solution (not solvent) There are.
1 Copyright © 2011, Elsevier Inc. All rights Reserved. Size Analysis and Identification of Particles Chapter 4 Roger W. Welker.
Influence of Ageing and Temperature on the Polarization/Depolarization Current Behaviour of Paper Immersed in Natural Ester Jian Hao 1, 2*, Ruijin Liao.
Teledyne Analytical Instruments
Gas Chromatography Vaporization of sample Gas-solid
Developments in Process Gas Analysis Robert Wright, Thermo ONIX.
The Effect of Microgravity on Brine Shrimp Development
Cruces-Blanco, C., Gamiz-Gracia, L., Garcia-Campana A.M., Applications of Capillary Electrophoresis in Forensic Analytical Chemistry Trends in Analytical.
Instruments & Radiopharmaceutical Production
E VERY L IFE H AS A P URPOSE… Chemgard TM Infrared Gas Monitor.
Edoardo Cardelli – Dipartimento di Fisica – Università di Cagliari Università degli Studi di Cagliari Dipartimento di Fisica Detector Quality Control Edoardo.
1 Density Calculations In this section, you will learn how to find the molarity of solution from two pieces of information (density and percentage). Usually.
Lecture 11. Microscopy. Optical or light microscopy involves passing visible light transmitted through or reflected from the sample through a single or.
An Introduction to Flame Atomic Absorption Spectrometry (FAAS) Steve Badger and Charity Wessel.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
PROVIDED BY EMAD BEHDAD SPECIALIZED PROTECTION AND CORROSION OF MATERIALS LECTURERS H.MONAJATI,PHD JAFARI,PHD ISLAMIC AZAD UNIVERSITY OF NAJAFABAD BARANCH.
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
IDDepth δ 13 CCarbonNitrogenδ 13 C Depth: (cm)(‰)(%) (‰)(cm) Gr. 3-5A %0.17% Gr %0.12% Gr %0.09%
Atomic Absorption and Atomic Fluorescence Spectrometry Wang-yingte Department of Chemistry
AA and Atomic Fluorescence Spectroscopy Chapter 9
Flame photometry.
E nergy D ispersive X -ray Fluorescence Spectrometer E nergy D ispersive X -ray Fluorescence Spectrometer EDX-720 Training.
Atomic Absorption Spectroscopy (AAS)
Spectroscopy Chapter 7.
Lead Content in Toys Katrina Nowak Chemistry 4101 Fall 2008.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Atomic-Absorption (AA) Spectroscopy 
Concentrations and Consumer Products. Percentage Volume/Volume (% v/v) Commonly used when both the solute and the solvent are liquids volume/volume =
Atomic Absorption Terry A. Ring Chemical Engineering University of Utah.
Field Methods XRF Copyright © 2013 by DBS. Atomic Spectroscopy for Metal Analysis Introduction to the Principles of Atomic Spectroscopy Atomic spectroscopy:
Workshop PET/SPECT/RADIO-ISOTOPES in Greece 26 June 2006 The XRF method: Development and Applications Ch. Zarkadas and A.G. Karydas N.C.S.R. “Demokritos”,
Total X-ray Fluorescence Spectroscopy (TXRF) Contact: World Agroforestry Centre (ICRAF), P.O. Box Nairobi, Kenya. Tel:
The determination of lead by MD-HG-AFS in APMP*-QM-P3 comparison Lu Xiaohua, Lu Hai, Ma Liandi, Cui Yanjie National Research Center for Certified Reference.
Atomic Absorption Spectrometry
Density Lab Introduction to Quantitative Measurement: Critical Question: Is density a characteristic property of a substance? Hypothesis: Materials Procedure.
Chem X-ray Crystallography X-ray crystallography is an experimental technique that exploits the fact that X-rays are diffracted by the periodic.
FISICA AMBIENTALE 1 Radioattività: misure 1 Lezioni Marie Curie.
Fluorometric determination of riboflavin
Fluorometric determination of riboflavin. Introduction.
Parts per Million Concentration. Parts per Million (ppm) is the ratio of the number of grams of solute for every one million grams of solution. parts.
Nuclear Instrumentation Laboratory Federal University of Rio de Janeiro -BRAZIL X-ray Fluorescence and X-ray Transmission Microtomography Imaging System.
COMPARISON OF DIFFERENT ANALYTICAL TECHNIQUES FOR ENVIRONMENTAL MONITORING OF CONTAMINATED SOILS Metodi Mladenov, Daria Ilieva University of Chemical Technology.
Seeing Enzymes in Action with Laser T- jump Time-resolved XAS/XPE/XWAS Jung Y. Huang Keywords: liquid phase, metalloproteins,
1 Analytical Chemistry CHEM 2310 Prof. Monzir S. Abdel-Latif.
G4GeneralParticleSource Class: Developed by ESA as the space radiation environment is often quite complex in energy and angular distribution, and requires.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Atomic-absorption spectroscopy
A TOMIC - ABSORPTION SPECTROSCOPY. Atomic absorption spectroscopy (AAS) is a technique for determining the concentration of a particular metal element.
Module 1 Biotechnology Basics Copyright © Texas Education Agency All rights reserved.
Atomic-absorption spectroscopy Lab3 Atomic-absorption spectroscopy.
Fluorometric determination of riboflavin
Geiger counter NTHU General Physics Laboratory
A TOMIC - ABSORPTION SPECTROSCOPY Lab no. 3 Done by : Iman Al Ajeyan.
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Chemistry 20  concentration: a ratio that compares the quantity of solute to the quantity of solution  A dilute solution has a relatively small quantity.
8.8 Concentration and Consumer Products. Recap: The amount concentration of a solution is the amount of solute per unit volume of solvent: c= n V where.
A cost effective scheme for detector pulse processing State machine operational flow Hardware implementation The embedded pulsed reset as a cost effective.
EBB 245. Materials Characterisation Lecture 3 X-ray Fluorescence Spectrometry (XRF) Dr Zainovia Lockman PPKBSM, USM (lecture presentations/notes.
By Maryum Atique M.Phill chemistry University of Agriculture.
QIAmp kit can also be used for samples of less than 180 mg (e.g., forensic samples). In such cases, follow one of the standard protocols, without.
Sampling Oil-Filled Transformers
Analytical Chemistry II ChEm 321
Flowcytometry.
Spectroscopy Chapter 7.
Separating Mixtures Lesson 5: Extracting Salt
iCAP OES Analysis of Trace Elements in Hair
Instrument Parameters in WDXRF
Characteristic physical properties
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Presentation transcript:

LIMITS OF DETECTION OF AN TOTAL REFLECTION SYSTEM WITH DOUBLE REFLECTION MODULE V. F. Nascimento Filho 1,2, V. H. Poblete 3 P., P. S. Parreira 1,4, E. Matsumoto 5, S. M. Simabuco 5, E. P. Espinoza 1 V., A. A. Navarro 1 1 Laboratório de Instrumentação Nuclear/CENA/USP 2 Departamento de Física e Meteorologia/ESALQ/USP 3 Laboratório de Fluorescencia de Rayos X/CCHEN, Chile 4 Departamento de Física/CCE/UEL 5 Departamento de Recursos Hídricos/FEC/UNICAMP Financial support: FAPESP

INTRODUCTION CHARACTERISTICS OF THE TECHNIQUE: •MULTIELEMENTAR, SIMULTÂNEOUS AND INSTRUMENTAL •ATOMIC NUMBER > 13 •HIGH GEOMETRIC EFFICIENCY DETECTION •LOW SAMPLE VOLUMES •MATRIX EFFECT CORRETION NOT NECESSARY •LOW LIMITS OF DETECTION •CAN BE USED FOR : ENVIRONMENTAL MONITORING BIOLOGICAL FLUIDS CONTROL QUALITY OF HIGH PURITY PRODUCTS SOLID SAMPLES (AFTER DIGESTION)

Photo and scheme: Total reflection fluorescence system (TXRF): visualization of the tower with the X-ray tube (XRT), high voltage generator (HVG), X-ray detector (XRD) and the total reflection module (TRM).

CONCLUSIONS LIMIT OF DETECTION volume of the sample on the support: 50 microliters excitation/detection time: 1000 seconds CHROMIUM IRON COPPER ZINC liquid samples: ppb solid sample: 10 mg digestion; 1 ml final volume ppm aerosol filter: 10 m 3 collected volume; digestion; 1 ml final volume ng/m 3 Financial support: FAPESP

RELATIVE SENSITIVITY

LIMITS OF DETECTION

REGRESSION LINES