New Construction Calibration Research Results and Request for Decision Regional Technical Forum March 18, 2014.

Slides:



Advertisements
Similar presentations
New MT Houses with Ground Source Heat Pumps Energy Savings and Costs June 2 nd, 2009 Regional Technical Forum 1.
Advertisements

Sunset Date Extension: Manufactured Homes HVAC Measures Regional Technical Forum November 18 th, 2014.
1 Residential Weatherization Calculator Deriving Realistic Savings Estimates for the “Uninsulated” House.
SEEM Calibration: Revisited Revising the regression to use continuous heat loss variable Regional Technical Forum December 17, 2013.
The Saga Continues: Measure Interactions for Residential HVAC and Wx measures Regional Technical Forum April 23, 2014.
MVP House in Montana Energy Savings and Costs March 2 nd, 2009 Regional Technical Forum 1.
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
NEEM Manufactured Homes Field Test Results David Baylon, Ecotope.
Heat Pump Water Heaters Provisional UES Proposal Regional Technical Forum October 4 th, 2011.
Electric “Grid” Savings and Non-Electric Benefits for Residential HVAC-effected UES Measures Regional Technical Forum March 20, 2013.
Prescriptive Duct Sealing UES Measure Proposal Regional Technical Forum Subcommittee July 8, 2013.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update March 17, 2015.
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
SEEM 94 Calibration to Single Family RBSA Data Regional Technical Forum January 23, 2013 Analysis Performed ByAdam Hadley Cursory Reviews By Tom Eckman,
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
1 Proposed Changes to the RTF’s Heat Pump Specifications Impact on Estimated Deemed Savings and C&R Discount Program Credits.
SEEM Tool Overview Regional Technical Forum Member Orientation January 22, 2013.
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF MH Calibration Subcommittee February 27, 2015.
Direction on Guidelines Savings Definition Path: CONTINUED Remaining Useful Life (RUL) and Measure Interaction Regional Technical Forum February 19, 2014.
Manufactured Homes Calibration: Existing and New Homes Josh Rushton & Mohit Singh-Chhabra RTF Update June 16, 2015.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Creating a DHP UES Measure Ecotope, Inc. July 16, 2013.
SEEM 94 Calibration to RBSA Data Progress Report on Phase 2 (Digging a Little Deeper) Subcommittee Regional Technical Forum March 20, 2013.
DHP for Houses with Electric FAF Research Plan: Revisions Adam Hadley, Ben Hannas, Bob Davis, My Ton R&E Subcommittee February 25, 2015.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Commercial Windows and Insulation RTF November 2, 2010.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
Agricultural Irrigation Pump Variable Frequency Drive Provisional Standard Protocol Proposal Regional Technical Forum April 16, 2013.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Northwest Ductless Heat Pump Pilot Project Impact & Process Evaluation: Billing Analysis Ecotope, Inc. February.
Heat Pump Water Heater Request for Feedback on a proposal to add UES measures with a “Retail – any installation location” delivery mechanism Regional Technical.
QC Follow-up for Single Family SEEM Calibration, HVAC UES Measures, and Weatherization Measures Adam Hadley Regional Technical Forum May 12, 2015.
SEEM Calibration: Phase-2 Adjustments for Failed VBDD Fits Regional Technical Forum August 12, 2014.
Analysis of Weatherization Measures Options for Savings Methodology and Presentation of Costs from 6 th Plan Regional Technical Forum May 4 th, 2010.
SEEM Input Variables for RBSA Calibration Manufactured Homes RTF Subcommittee on SEEM MH Calibration May 9, 2013.
Minimizing Structural Energy Loss Andrew Layman Lisa Phillips.
Andrew Layman Lisa Phillips. What is the primary source of energy loss in a house and what are some solutions to minimize this loss?
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Follow-up from August RTF.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum September 17, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
SEEM Calibration: Phase II Single Family Heating Energy Regional Technical Forum August 20, 2013 Presented By: Josh Rushton and Adam Hadley Subcommittee.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum November 19, 2013.
SEEM Calibration for Manufactured Homes Regional Technical Forum July 15, 2014.
SEEM Calibration: Phase-2 Adjustments for Failed VBDD Fits RTF Calibration Subcommittee July 31, 2014.
Northwest Power and Conservation Council Residential Conservation Resource Assessment Overview of Analytical Process and Major Assumptions April 21, 2009.
Research Strategy Review: Advanced Power Strips MH HVAC Related Measures Jennifer Anziano RTF R&E Subcommittee August 6, 2015.
Guidelines Revisions Defining What RTF Means by “Savings” December 17,
REM as a Compliance Tool Infiltration Trade-off REMRate vs. SEEM February 19th,
SEEM Calibration for Manufactured Housing Regional Technical Forum December 13, 2011 Analysis Performed ByAdam Hadley Cursory Reviews ByTom Eckman, Ben.
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Analysis of Weatherization Measures Savings Methodology and Costs: Updated from 6 th Plan Regional Technical Forum June 1 st, 2010.
Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014.
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
New-Construction Manufactured Homes: Update on the Path to Proven Savings Regional Technical Forum November 10 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Northwest Power Planning Council Residential Space Conditioning and Domestic Hot Water Conservation Resource Assessment Overview of Analytical Process.
Electric “Grid” Savings and Non-Electric Benefits for Residential HVAC-affected UES Measures Regional Technical Forum March 20, 2013.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum October 16, 2013.
PTCS Ducts Inside Single Family New Construction Energy Savings and Cost Regional Technical Forum May 5,
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Multifamily Homes: Calibration Update Regional Technical Forum December 8 th, 2015.
New Construction Calibration Preliminary Research and a Request for Guidance on Issues Raised in December Regional Technical Forum January 22, 2013.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
Where did it go? Lost savings found in real-world data SEEM Calibration for the Northwest Power and Conservation Council’s Regional Technical Forum (RTF)
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
RTF Management Update Jennifer Anziano Regional Technical Forum June 16, 2015.
Planning UES Measures: SF New Construction Heat Pump Upgrades (9.0 HSPF and VCHP) Heat Pump Commissioning Controls and Sizing Adam Hadley Regional Technical.
Planning UES Measures: Prescriptive Duct Sealing SF Performance-based Duct Sealing SF Performance-based Duct Sealing MH Adam Hadley & Josh Rushton Regional.
Extra Slides to Accompany: SEEM 94 Calibration to Single Family RBSA Data Analysis and proposed actions Regional Technical Forum May 21, 2013.
RTF Management Update Jennifer Anziano Regional Technical Forum March 17, 2015.
RTF Management Updates Jennifer Light Regional Technical Forum February 17, 2016.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
Presentation transcript:

New Construction Calibration Research Results and Request for Decision Regional Technical Forum March 18, 2014

Overview Decided in February: Supplemental heat in NC homes (Calibration Phase II) – Use previously approved adjustments (based on RBSA). Today’s topic: SEEM estimates of total heating energy (Calibration Phase I) – Is the heat loss effect captured in the previously approved calibration appropriate for NC homes? 2

Reminder: Calibration Phase I 3 Approved (Modified) by RTF on Dec. 17, 2013 Are the captured effects and approved adjustments right for NC homes? Compared SEEM (69/64°F) energy estimates to billing estimates. Restricted to 429 RBSA homes with well-known characteristics, no non-utility fuels, and clear heating signatures in billing data. Regression used to determine adjustment factors that align SEEM (69/64°F) with billing data. Other RBSA (975) Calibration Sample (429)

The Uo Pattern 4 y > 0 means SEEM 69/64 > VBDD SEEM 69/64 < VBDD for lower-Uo homes SEEM increases relative to VBDD as Uo increases Average SEEM – VBDD difference roughly constant across high Uo values Pre-1992 Post-1992 y-axis: percent difference SEEM 69/64 - VBDD

The Uo Pattern 5 Examples: When Uo (Both) = SEEM 69/64 averages around 25% over VBDD. When Uo (Both) = 0.100, SEEM 69/64 averages about the same as VBDD. When Uo (Both) = 0.075, SEEM 69/64 averages around 25% under VBDD. Pre-1992 Post-1992 What does the pattern mean?

Adjustments to Account for the Pattern 6 Calibration adjustments align SEEM 69/64 with billing data. Primary Heating Equipment Heating Zone Adjustment factor at Uo both* = Adjustment factor at Uo both* = Elec.Res.Zone Elec.Res.Zone Elec.Res.Zone Gas/HPZone Gas/HPZone Gas/HPZone * Uo both includes heat loss due to infiltration.

The Uo Pattern 7 Professional judgment: Can’t know for sure since RBSA data doesn’t go that low. Would downward trend continue to the left or would it flatten out? Right course of action depends on what we think is driving the pattern. Pre-1992 Post-1992 What happens when Uo (Both) < 0.075?

The big questions 8 1.What do we think happens for very low U- values? o Would the downward trend persist, or o Would it flatten out? 2.Should we use different adjustment factors for baseline and efficient cases? o Yes, if trend is caused by Uo (e.g., homes with high heat loss have lower average temperatures). o No, if trend has some other cause. o Have ruled out several non-Uo culprits (vintage, heating system type, lack of duct tightness / infiltration tests, …)

Decision for NC U-value Issue 9 I move that the RTF use RBSA data to calibrate SEEM 94 for single-family new construction, but that the current Phase I model should be modified so that the U variable is constant for Uo (Both) below As applicable, different adjustments will be calculated for baseline and efficient cases. OR I move something else…

Additional Slides 10

Does the calibration sample include Uo values as low as current NC levels? Uo values didn’t change much between 1992 and But they seem to have have really decreased after Graph shows conductive-loss-only Uo

12 Does the calibration sample include Uo values as low as current NC levels? Lots of post-92 sites (137) but few post-08 sites (9) Post-92 sites are fairly well-insulated o Average post-92 ceiling R-value is 30 o About half have ceiling R-value over 38 But few Uo values as low as we’d like o NC measures need Uo-conductive around 0.04 to 0.07 o RBSA sample’s min is o Only 6 below 0.055, 16 below 0.060, 44 below 0.065

Additional Slides: How do the adjustments work in measure calculations? 13

Calibration Adjustment Factors 14 Adjustment factors 0.96 for Uo = for Uo = for Uo = Graph is for Z2 homes with electric resistance heat.

Adjustments and shell measures 15 Example: Shell measure that reduces Uo-both from to in the prototype house. – This would decrease cold-weather heat loss rate by 0.010/0.065 = 15.4%. – Adjustment factors would reduce savings: Efficient case adjustment factor of 0.96; Inefficient case adjustment factor of This knocks about 3 percentage points off the savings rate.

Additional Slides: What’s causing the pattern? 16

Possible Causes 17 Assuming the pattern does persist, should savings calculations be based on efficient- and base-case adjustment factors that differ according to Uo? If pattern is caused by differences in heat loss rates, then a Uo- indexed adjustment factor would be correct. – Ex. 1: Well-insulated homes have higher average inside temperatures (no cool areas on the periphery). – Ex. 2: If SEEM inputs are over-stating internal gains, then SEEM must be under-estimating heating energy; such errors would tend to be larger (in percentage terms) for the better-insulated houses.

Possible Causes 18 Assuming the pattern does persist, should savings calculations be based on efficient- and base-case adjustment factors that differ according to Uo? If pattern is due to something else, then a Uo-indexed adjustment factor would be incorrect. (Shouldn’t debit shell measures for things that are accounted for in other measures.) – Ex 1: Better-insulated homes may tend to have better HVAC CCS than we were able to account for in SEEM runs. – Ex 2: Very well-insulated homes may tend to have tighter ducts than moderately well-insulated homes.

Someone asked if the low-Uo homes might tend to be large recently-built homes in Zone 3. This doesn’t appear to be the case: 19 Uo

Someone asked if the pattern might be due to the fact that a lot of homes didn’t get blower door tests (we imputed infiltration values for these in SEEM input). 20 Doesn’t appear to be the case. If it were, then the pattern should go away for homes that had actual blower door tests.

Someone asked if the pattern might be due to the fact that a lot of homes didn’t get duct tests (we imputed duct leakage values for these in SEEM input). 21 Doesn’t appear to be the case. If it were, then the pattern should go away for homes that had duct blaster tests. (We already knew about the zonal heat effect)

Is it possible that the apparent Uo effect is partially due to heat source cost-efficiency? 22 When cost-efficiency is coarsely coded as “Elec. Res. vs. gas/ HP”, the equipment effect appears to be incremental to the Uo effect.