Hemodialysis Machine.

Slides:



Advertisements
Similar presentations
Chapter 9 Capacitors.
Advertisements

Transducers PHYS3360/AEP3630 Lecture 33.
An Electronic System Power Supply Example
MOTION CONTROL ECE 105 Industrial Electronics Engr. Jeffrey T. Dellosa College of Engineering and Information Technology Caraga State University Ampayon,
DC Choppers 1 Prof. T.K. Anantha Kumar, E&E Dept., MSRIT
Fundamentals of Circuits: Direct Current (DC)
Alternating Current Circuits
1 Chapter 5 Sensors and Detectors A detector is typically the first stage of a communication system. Noise in this stage may have significant effects on.
Part A: Controlling Oscillation Frequency with Capacitors and Resistors Part B: Diodes and Light Experiment Timer.
Power Electronics Lecture-7 Unijunction Transistor &
Copyright by UNIT III DC Choppers 4/17/2017 Copyright by
Astable multivibrators I
Control System Instrumentation
Power Electronics Introduction Bipolar Transistor Power Amplifiers
OSCILLATORS.
EKT214 - ANALOG ELECTRONIC CIRCUIT II
AccuMax Multi-Point Injection Mechanics
Types of Dialysis  1. Hemodialysis  2. Peritoneal dialysis – just be aware of it’s existence.
EKT314/4 Electronic Instrumentation
Lecture 3: Bridge Circuits
Chapter 22 Alternating-Current Circuits and Machines.
Electrical, Electronic and Digital Principles (EEDP)
CHAPTER 6 VOLTAGE REGULATOR POWER SUPPLIES (VOLTAGE REGULATORS) Fig. 6.1 Block diagram showing parts of a power supply. Power supply Power supply: a.
Thyristor application & photosensitive control circuits
Eulogio Amang Rodriguez Institute of Science and Technology Nagtahan, Sampaloc, Manila Vacuum Tubes Amplifiers.
Chapter 28 Direct Current Circuits 1.R connections in series and in parallel 2.Define DC (direct current), AC (alternating current) 3.Model of a battery.
Topic 28: Direct Sensing 28.1 Sensing devices
Power Supply Design J.SHANMUGAPRIYAN.
Magnetic Contactor For handling large current and voltage.
1 Optocouplers. 2 LED for emitter Air as barrier for isolation Phototransistor for detector Transformer is similar, but only for AC Optocoupler can be.
SEMICONDUCTORS Triacs and Diacs.
PROGRAMMABLE LOGIC CONTROLLER DNT 353/3
Control System Instrumentation
EKT 451/4 SEM 2 Chapter 6 SENSOR & TRANSDUCER SHAIFUL NIZAM MOHYAR
Biomedical Electrodes, Sensors, and Transducers
Name: ________________ Class: _________________ Index: ________________ D.C. Circuit.
STEPPER MOTORS Name: Mr.R.Anandaraj Designation: Associate. Professor Department: Electrical and Electronics Engineering Subject code :EC 6252 Year: II.
CHEM*3440 Operational Amplifiers These integrated circuits form the backbone of modern instrumental methods. Understanding their operation will help you.
Large Signal Amplifier Design Ryan Child 1. Background Large Signal Amplifiers belong to a class of amplifiers that are used for applications where high.
Electronic. Analog Vs. Digital Analog –Continuous –Can take on any values in a given range –Very susceptible to noise Digital –Discrete –Can only take.
AUTOMATIC RAILWAY GATE CONTROLLING AND TRACK SWITCHING
Lecture 3: Bridge Circuits
18240 Element two - Components INPUTS OUTPUTS PURPOSE TYPICAL USE.
Closed Circuits In applications requiring the use of current, electrical components are arranged in the form of a circuit. A circuit is defined as a path.
COMPUTER SMPS POWER SUPPLY
BLDC Motor Speed Control with RPM Display. Introduction BLDC Motor Speed Control with RPM Display  The main objective of this.
Balances The balance is an instrument which measures the mass of a body or substance using the gravity force which acts on that body At present, there.
DESIGN OF MONO-AXIS SOLAR TRACKING SYSTEM USING MICROCONTROLLER BASED STEPPER MOTOR KAMAL J K KOUSHIK VENKATRAMAN N PREM M PRASANTH K Guidance: Mrs.Kavitha.
CHAPTER 5 DC AND AC BRIDGES.
Signal Conditioning Elements (SCE). 6/13/2016Measurement & Transducers2 1. Voltage dividers Example :Potentiometer circuit.
As Unit 1 - Electricity What you need to know..  Current is the rate of flow of charged particles.  In metals these are conduction electrons, most electrons.
Hemodialysis.
Additional information on Passive Probes (10x) Take note that the scope’s input capacitance, C in must falls within the probe’s compensation range For.
EKT 451 CHAPTER 6 Sensor & Transducers.
1 Transducers EKT 451 CHAPTER 6. 2 Definition of a Transducers   Transducer is any device that converts energy in one form to energy in another.  
Different Types of Voltage Regulators with Working Principle.
Half-wave Rectifier.
CHAPTER 6 MESB System Modeling and Analysis Hydraulic (Fluid) Systems
Control System Instrumentation
(2) Bridge Circuits.
Hemodialysis Lecture 3.
Fault detection Lecture (3).
POWER AMPLIFIERS.
Control System Instrumentation
Amplifiers Classes Electronics-II
Control System Instrumentation
Power Electronics Introduction Bipolar Transistor Power Amplifiers
Amplifiers Classes Electronics-II
ENT 318 Artificial Organs Artificial kidney
Presentation transcript:

Hemodialysis Machine

Hemodialysis Machine Basic Functions of Hemodialysis Machine - Mixes the dialysate. - Monitors the dialysate. - Pump the blood and controls administration of anti-coagulants. - Monitors blood for presence of air. - Monitors ultra-filtration rate. Dialysate Temperature Control and Measurement Dialysis normally done at body temperature. Lower than body temperature, dialysis is less efficient and blood has to be warmed before return to patient.

Hemodialysis Machine High temperature (>40oC) will damage components of blood. Thus, temperature of dialysate is monitored and controlled before supplied to dialyzer. Temperature control system used to raise temperature of dialysate to a required value. If temperature exceeds, safety cut-out will ensure heater switched off. Required temperature varied from 36 to 42oC. Two types of circuit for control of temperature : - Bi-metallic thermostat. - Electronic proportional controller. The latter use thermistor for sensing temperature and triac for control of power to heater.

Hemodialysis Machine

Hemodialysis Machine Uni junction transistor off until capacitor charges to a point of breakdown voltage. Then transistor conducts and capacitor discharged through pulse transformer. Thus, triac gets a triggering pulse and switches on the heaters. The triac switches off at the end of each half-cycle and remains so until triggered once again. Thermistor has negative temperature coefficient. When temperature increase from set value, resistance of thermistor decrease which will reduce charge rate of C. So frequency of charge and discharge reduces, less power delivered to heaters which results in reduction in temperature. Temperature can also be controlled by varying resistance R3, therefore any temperature can be set.

Hemodialysis Machine In micrprocessor-based hemodialysis machine, fluid temperature is displayed on monitor and control circuitry will control the heaters. Dual element heater assembly with 150 W and 300 W element are used to heat up fluid and maintain it in operating temperature. When temperature rises within 2.5oC of preset temperature, 300 W heater off and only 150 W heater is used to maintain the set temperature. Enabling of heaters also dependent upon the fluid flow rate. Microprocessor reads the flow pulses and determines if there is adequate flow within the system. If flow inadequate heater elements disconnected. Flow is measured using flow-thru transducer. Sensor assembly includes light source and photo-transistor to provide optical coupling with sensor.

Hemodialysis Machine

Hemodialysis Machine Flow-thru transducer produces precise number of pulses per unit flow. Achieved by monitoring rotation of a disk which contains light reflective white spots. Light pulses from rotating disk transmitted by internal fiber optics. Pulses generated by flow transducer are amplified, filtered and counted to determine flow rate. Conductivity Measurement Conductivity of dialysate is monitored by conducting cell to verify accuracy of proportioning. Result displayed as percentage deviation from the standard. Composition of dialysate is checked by comparing electrical conductivity of dialysate with standard sample of dialysate.

Hemodialysis Machine

Hemodialysis Machine The circuit for conductivity measuring system comprises of a 1.5 kHz oscillator which drives a bridge circuit. One arm of bridge contains conductivity cell. Compensation thermistor placed in another arm of the bridge. Thermistor is placed so that the circuit provide fast response to changes of solution temperature. Without thermistor, change in temperature would affect measurement. Enabling of heaters also dependent upon the fluid flow rate. After amplification, output from bridge capacitively coupled to phase-sensitive detector. The phase is compared with the phase of 1.5 kHz oscillator output. Magnitude and phase from detector determine the direction and amount of deviation from pre-set value.

Hemodialysis Machine Dialysate Pressure Control and Measurement Negative pressure upon dialysate created by effluent pump. Effluent pump is a fixed-flow, motor-driven gear pump. Pressure between zero and maximum by adjustment on machine panel. A relief valve limits maximum negative pressure and minimizing risk of burst in dialyzer membrane. Pressure adjustment should not produce any significant change in flow rate. Pressure measured by strain gauge transducer. Dialysate pressure is measured on one side of membrane and venous pressure on the other side. Effective pressure across membrane is algebraic sum of dialysate pressure and venous pressure.

Hemodialysis Machine This effective pressure important in consideration of filtration and weight control. If pressure goes beyond limit, effluent pump switched off. Dialysate by-passed to drain by way of header tank overflow and waste funnel. Venous Pressure Measurement Measured at bubble trap. A tubing connects the trap to a strain gauge transducer. If pressure beyond limit, power to blood pump will be isolated and pump will not be used. Bubble trap Air embolism is serious hazard in dialysis. Air may be sucked in due to inadequate flow in the line in the pumped dialysis system. Bubble trap is equipped to diminish air embolism.

Hemodialysis Machine Heparin Pump Usually of the plastic syringe type. Pump driven by stepper motor and drive screw mechanism. This drives the plunger of the syringe into its barrel which produces the pumping action. Stepper motor speed determined by computer based on heparin flow rate. Speed of stepper motor monitored using optical encoder. Blood Leak Detector Blood leakage across dialyzer membrane can be detected by using photo-electric transducer. Leak detector examines light absorption of dialysate at 560 nm i.e. absorption wavelength of haemoglobin.

Hemodialysis Machine

Hemodialysis Machine A chopped light system with AC amplifiers is employed. Chopping achieved by driving LED with square wave of current. Compensation thermistor placed in another arm of the bridge. The light is detected with cadmium sulphide photo-conductive cell. Absolute value circuit provides signal whose peak value is proportional to the received 560 nm light. The peak value is compared to a reference voltage which is pre-set. Maximum setting detects blood leaks at rate of 65 mg/l of dialysate. If blood leak is detected, the effluent pump switched off automatically .

Hemodialysis Machine Ultrafiltrate Monitor Used to monitor amount of fluid removed from the patient. Also control the rate at which fluid is removed. Ultrafiltration rate calculated by CPU in hemodialysis machine. The load cell and associated electronics are used to monitor weight changes of fluid in reservoir. The load cell utilizes a strain gauge that produces a differential resistance proportional to the applied force. The differential input connected to instrumentation amplifier which gives gain. Weight signal in DC is changed to a proportional frequency. Pulses corresponding to the weight are then counted and given to the microprocessor.

Hemodialysis Machine

ANALYSIS OF DIALYZER Clearance Complete removal of a solute from blood during a single pass defines the dialyzer clearance for that solute as equal to dialyzer blood flow. Under condition of steady-state dialysis, mass conservation requirement is expressed as N is overall solute transfer rate between blood and dialysate. QB and QD are blood flow and dialysate respectively. CBi, CBo, CDi and CDo are solution concentrations C in blood,B, or dialysate, D, at the inlet, i, or the outlet, o of the machine. Dialyzer clearance is defined as mass transfer rate N divided by concentration gradient prevailing at the inlet of dialyzer.

ANALYSIS OF DIALYZER K is clearance. Mass transfer rate also means the amount of solute from the blood per unit time, which in turn equals to the amount of solute accepted in dialysate per unit time. There are two expressions for dialysance Maximal achievable clearance at any combination of blood and dialysate flow rate without reference to solute concentration.

ANALYSIS OF DIALYZER Filtration Ultrafiltration is defined as difference between blood flow entering the dialyzer and blood flow leaving the dialyzer. Ultrafiltration can be enhanced by increasing resistance to blood flow at dialyzer outlet. Blood compartment pressure will be raised by subjecting dialysate to a negative pressure. When CDi=0 and CBo=CBi, blood dialysance will equal to filtration KB=F

ANALYSIS OF DIALYZER Example A dialyzer has urea clearance 160 ml/min. Urea concentration at blood inlet is 0.2 mg/ml while urea concentration at dialysate inlet is 0 mg/ml. Calculate urea transfer rate, N.

ANALYSIS OF DIALYZER Example Concentration of urea in blood outlet and dialysate outlet are 0.08 mg/ml and 0.06 mg/ml respectively. Given blood flow rate is 200 ml/min and dialysate flow rate is 600 ml/min. Calculate urea transfer rate. Assume dialysate at inlet has zero concentration of urea.

ANALYSIS OF DIALYZER Compartment diagram