Dialysis Water Treatment Systems

Slides:



Advertisements
Similar presentations
Our World is Water Water treatment in container – with guarantee for quality and performance EUROWATER.
Advertisements

Let’s watch a DVD… DVD Instructor Notes
St. Eustatius drinking water production
Chemistries and Physics of Water Purification
Common Water Treatment Problems Hard Water -Calcium and Magnesium. Soap Scum, and Scale Build-Up. Iron - Clear (Ferrous), Red (Ferric), & Bacteria Related.
WHO - PSM Water –part 3 Workshop on GMP and Quality Assurance of HIV products Shanghai, China 28 Feb - 4 March 2005 Maija Hietava M.Sci.Pharm Quality Assurance.
WHO - PSM Water for Pharmaceutical Use Water –part 2 Workshop on GMP and Quality Assurance of HIV products Shanghai, China 28 Feb - 4 March 2005 Maija.
Water Purification and Treatment
INDIAN RAILWAY INSTITUTE FOR CIVIL ENGINEERS INTEGRATED COURSE, BATCH No 514 Water Treatment Through Reverse Osmosis System Presented by: 1. J. Gowri Shankar,
New Developments in Renal Dialysis WH Seto WHO CC, Hong Kong 5, 2012 Hosted by Prof. Lance Jennings University of Otago,
1 Reminder: Resistivity (ohms) is the reciprocal to conductivity (micro-Siemens)
1 FUNDAMENTAL OF ION EXCHANGE WATER SOFTENING 2 HARD WATER Water containing calcium (Ca+2) and magnesium (Mg+2), the hardness minerals. Water containing.
Water for Pharmaceutical Use Water Purification Engineering Md. Saifuzzaman Associate Professor Pharmacy Discipline, KU.
Technical Manager, Hydropath Holdings Ltd.
Energy Advisory Board Water Treatment Rifle, Colorado - March 1, 2007.
Spray Finishing Operations/Spray Booth March 9, 2009.
WATER PURIFICATION. We all need clean water, water that is free of potentially dangerous contaminants. For our homes we need basic clean and sanitary.
Pharmaceutical Water Systems Alain Kupferman Manufacture of sterile medicines – Advanced workshop for SFDA GMP inspectors, Nanjing, November 2009.
POINT OF ENTRY POINT OF USE BOTTLED WATER
Utility Validation on Validation of Water Treatment Systems for Pharmaceutical Products. Dr. Hetal R. Prajapati H. R. Prajapati1.
Information about Purified water Ten steps to Purified Water Photos of Purified water in process Conclusion.
Waupun Utilities Water Treatment Facility. Treatment Processes Source Water Pretreatment System Reverse Osmosis System Post Treatment System Distribution.
OZONE DRINKING WATER SYSTEM. CONTENTS Properties of Ozone Production of Ozone Water Treatment Plant – 25 m 3 /hr Ozone Generation System.
Water Purification Systems for Clinical Lab Prepared By Farid Khalaf.
Water and Solubility Write a definition for these words: Solute: Solvent: Solution: Atmospheric water vapour Run-off Transpiration Atmospheric water vapour.
THE BASICS of SFR Spot Free Rinse Systems - working to keep your reputation spotless  Spot Free Rinse water must have less than 40 ppm of TDS. Our preferred.
How to obtain fresh water Section - E6.3 Chemistry 12 – SL Isabelle R.
OPG WTP Performance / Trends in High Purity Water Treatment Presented at IAPWS Workshop May 11, 2009 By Gabriel Nicolaides.
Transitions to Surveys with New ESRD Regulations
Reverse Osmosis Feed Treatment, Biofouling, and Membrane Cleaning
Filename: C-CR-10-02Rev00Page 1 of 3Record no.: C-CR-10-02Rev00 Appendix 2(a): Water Treatment Equipment and Sampling Points Guideline for Water Treatment.
1 Practical Tips to Emergency Preparedness John Dahlin CHT, CWS-1 Texas ESRD Emergency Coalition.
Water for Pharmaceutical Use Part 2: Water purification engineering
Processing, distribution and use of water.
Chapter 1.D. Water Cycle.
The Drinking Water Treatment Process
QUALITY ASSURANCE Quality Assurance of Reagents, Supplies, And Laboratory Water.
JEOPARDY Karen Evans RN BSN CHT CBNT NANT President Englewood Dialysis Center/FMC Home Therapies Manager.
Anion Exchange for Drinking Water Treatment
Water and Wastewater Treatment
The Water Cycle. What are some things that you think are in your water?
Water Softener Systems Engineered Water Treatment Solutions.
Water Purifiers Proaudio55 (Own work) [CC BY-SA 3.0 ( via Wikimedia Commons.
SPOT ZERO REVERSE OSMOSIS SYSTEM Welcome to Elite Marine Services.
HOUSEHOLD WATER TREATMENT. Water Quality Problems Recommendations New source Pollution control Maintenance + inspection Treatment Explore all of them.
Water Treatment Fundamentals. Agenda MEP Fundamentals (1 st badge): Ion exchange chemistry Softener designs and options Ion exchange capacity calculations.
How Reverse Osmosis Water Purification Systems Work.
Reverse Osmosis Basics
RO and standards Your title can go in a clear space
RO Basics and System set up
Water Treatment Basics
REVERSE OSMOSIS PLANTS 5-35kl/day
CHAP. 2.2 – WATER TO DRINK.
Engineered Water Treatment Solutions
REVERSE OSMOSIS PLANTS kl/day
Boiler System Make-up Water Primary Secondary Pretreatment
WATER QUALITY (Chapter 22)
MULTIPLE CHOICE QUESTIONS
THE BEST METHOD FOR WATER FILTRATION – REVERSE OSMOSIS.
Volume 76, Issue 6, Pages (September 2009)
Private Homeowner Drinking Water Issues
Troubleshooting 11/14/2018 Water King Service Seminar.
Softening of Water : Softening can be done in two ways
ION EXCHANGE ADSORPTION
POINT OF ENTRY POINT OF USE BOTTLED WATER
Volume 76, Issue 6, Pages (September 2009)
مبانی کار تصفیه‌خانه‌های آب
Treatment – Ion Exchange Filters
C10: Sustainable Development
Terry A. Ring Chemical Engineering University of Utah
Presentation transcript:

Dialysis Water Treatment Systems Rational, Function, Water Testing and Documentation

Introduction AAMI (Association for the Advancement of Medical Instrumentation) since 1982 has set the standards for all Hemodialysis Equipment, Water Treatment, Hemodialysis Concentrates and Hemodialyzer Reprocessing AAMI states that the medical director has ultimate responsibility for the water treatment system and all testing and performance of that system Water Treatment Systems installed after May 30,1997 must are subject to the FDA 510(k) approval process It is imperative that a dialogue be maintained with the feedwater suppliers

Rational Hemodialysis Water Treatment Standards are an evolutionary process dictated by data and information gathered on the effects of water on patient mortality and morbidity. Sadly many patients have died over the years as a result of ignorance, carelessness , bad luck and the failure to follow the standards then in effect. Education of all members of the dialysis treatment team will allow us to be more cognizant of the dangers involved in the treatment process, and encourage us to do our best for our patients

Temperature Blending Valve Mixes hot and cold water to maintain a constant temperature of 77 F or 25 C This prevents harm to patients and damage to the RO (reverse osmosis ) membranes Product water output will decrease as the temperature decreases A temperature gauge is placed downstream and is monitored

Blending Valve and Booster Pump

Booster Pump Maintains a constant flow and pressure to the Pretreatment components and the RO Pressure gauges are placed before and after the pump and are monitored

Sediment Filters Filters larger particles from the feedwater This protects the downstream pretreatment equipment and the RO This system is routinely backwashed at night by the use of an automatic timer and is connected to the RO with lockout protection Pre and post pressure gauges are used and monitored

Sediment Filter

Water Softener Removes Calcium and Magnesium from the feedwater to prevent scaling on the Carbon filters and the RO An ion exchange resin is used that attracts Calcium and Magnesium and releases a Sodium ion The softener is regenerated at night by an automatic timer and is connected to the RO with lockout protection Pre and post pressure gauges are used and monitored Water hardness testing is done and documented at the beginning and end of the treatment day

Water Softener

Carbon Filters Removes chlorine, chloramines and organic compounds by the use of GAC (granular activated charcoal) Two tanks in series are used Feedwater must contact the carbon for a EBTC (empty bed contact time) of at least 10 minutes The carbon cannot be regenerated, but a flushing is done at night with an automatic timer Pre and post pressure gauges are used and monitored Chlorine and chloramine testing must done and documented before each patient treatment

Carbon Filters

Reverse Osmosis System Purifies large volumes of relatively pure water at low cost Usually has a 5 micron filter that removes carbon fines and resin beads Water pump forces pretreated water at high pressure through semi-permeable membranes Efficiently removes > 95% of ions Removes bacteria but not endotoxins Has alarm system to protect patient

RO Data Sheet

RO Control Box

RO Display Screen

DI Deionization is generally used as a backup in case of RO failure Most systems use a dual bed (cation and anion) system of ion exchange resins Produces water purer than a RO but is very expensive Does not remove bacteria or endotoxins Must be regenerated offsite from vendors that deal with medical or food grade systems Resistivity must be continuously monitored to 1 megohm with an audible and visual alarm in patient area and a product stop or divert

DI Control Box and Resistivity Meter

Ultrafilters Used to remove bacteria and endotoxins from product water Required downstream from a DI system

Ultrafilters

Ultraviolet Irradiators Used to control bacteria in a water storage and distribution system The intensity of the UV light must be monitored and alarmed (visual) to insure sufficient kill intensity Ultrafilters are recommended downstream from the UV light

RO Water Storage Tank Water storage tanks are used when a direct feed system isn’t feasible or recommended Must have a conical bottom, tight fitting lid and a hydrophobic 0.2 micron air filter The recirculating pumps run 24/7 to keep bacteria from forming on the walls of the tank and in the The water flow velocity must be at least 3 feet per second (1.5 feet per second for direct feed)

RO Water Storage

Water Testing AAMI Chemical Analysis A test of 21 chemical contaminants performed at least once a year ,and when there are feed water changes. See AAMI standards for limits Bacteria Colony counts Performed monthly per AAMI standards Action Level > 50 CFU/mL Maximum Level 200 CFU/mL LAL Endotoxin Action Level > 1.0 EU/mL Maximum Level 2.0 EU/mL An Action process must de developed to deal with the situation when limits for any water tests are exceeded

Documentation Chemical Contaminants, Bacteria Colony Counts and LAL Endotoxin should be consolidated to allow for trend analysis and government audits A Water Treatment System Log should include but not limited to data from all pressure and temperature gauges, RO data screen, post softener hardness results, brine tank inspection and action, chloramine test results and any action, filter change, cultures performed, cleaning and/or disinfection completed on the water treatment system (see handouts)