New Groundwater Techniques and Technologies 17 th Annual RETS REMP Conference June 25-27, 2007 Eric L. Darois, CHP EPRI Consultant/RSCS Inc.

Slides:



Advertisements
Similar presentations
Overview of the EPRI Groundwater Assessment Program
Advertisements

Case Study of Subsurface Vapor Intrusion at a Dry Cleaner Site Amy Goldberg Day AEHS Annual East Coast Conference on Soils, Sediments.
COMPARISONS OF SUB-SLAB SOIL GAS MEASUREMENTS TO MODELED EMISSIONS FROM SUBSURFACE CONTAMINATION by John A. Menatti and Robin V. Davis Utah Department.
Multi-Level Ground-Water Monitoring Travis von Dessonneck.
 ideally the disposal methods should meet the following condition:  environment friendly  cause no health hazard  economically less demanding  maximum.
Modeling Atmospheric Releases of Molecular Tritium 2005 RETS/REMP Workshop Jim Key Key Solutions, Inc.
Vapor Intrusion. What is Vapor Intrusion? The migration of volatile chemical vapors from the subsurface to overlying buildings.
© 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies.
Conductivity Testing of Unsaturated Soils A Presentation to the Case Western Reserve University May 6, 2004 By Andrew G. Heydinger Department of Civil.
Dale T Littlejohn Senior Geologist. What is fate and transport in the vadose zone? Vadose Zone Hydrocarbon release from buried pipeline Aquifer Surface.
Features of POLLUSOL Flow model Flow model Homogeneous, Isotropic, Heterogeneous and Anisotropic medium Homogeneous, Isotropic, Heterogeneous and Anisotropic.
1 Groundwater Pollution Week 5 – 0407 Investigating the Site and Monitoring.
1 Hydrologic Cycle is the never ending cyclic exchange of water
Multiphase Extraction for Soil and Groundwater Remediation Nick Swiger Spring 2007.
Groundwater The Unseen Part of the Water Cycle Salt Groundwater Ground Water Reservoir The present-day surface hydrologic cycle. The numbers in parentheses.
1 Soil Vapor Extraction Limitations and Enhancements LeeAnn Racz AgE 558 Semester Project April 2001.
EMSP Workshop, 2003 LA-UR Field-Scale in situ Measurements of Vadose Zone Transport Using Multiple Tracers at INEEL Vadose Zone Research Park Robert.
Groundwater. In the U.S. we use: 400 million gallons of water a day to drink 450 billion gallons of water a day in our homes, agriculture and industry.
.
Vapor Intrusion Guidance Proposed Updates
A Numerical Study of Barometric Pumping Jeff Sondrup AgE 588 Fluid Mechanics of Porous Materials April 11, 2001.
Soils Investigation Soil Investigation
Acquisition and Interpretation of Water-Level Data Travis von Dessonneck.
RETS REMP 2007 Philadelphia, PA June 25 – 27, 2007 Eric L. Darois, CHP
Variation of Natural Radon Flux Density Over the Earth’s Surface: a 2010 Update Stephen Schery NASA/AMES, USA New Mexico Tech 1.
Vadose-zone Monitoring System
Characterization of Pore Structure of Membranes Akshaya Jena and Krishna Gupta Porous Materials, Inc. 20 Dutch Mill Road, Ithaca, NY Akshaya Jena.
Karen Kim Sr. Project Engineer, EPRI
Vapor Intrusion Evaluation Strategy and Modeling Developments
FSA Groundwater Flow and Solute Transport Model Presentation to Scottsdale Citizens Group March 19, 1999.
Vadose Zone & Autosamplers. Autosamplers An autosampler is a programmable liquid sampler that is capable of operating in hostile environments such as.
Soil Water Reading: Applied Hydrology Sections 4.1 and 4.2 Topics
Industrial Air Quality Monitoring. Sampling Protocols Grab vs. Integrated Personal vs. Area.
Enviromental aspects of Brownfield Regeneration Barbara Vojvodíková, Marcela Maturová „This project has been funded with support from the European Commission.
Overview of USGS Groundwater Quality Assessment Activities and Related Data in Alabama 2011 Alabama Water Resources Conference September 9, 2011, Perdido.
DTSC VAPOR INTRUSION GUIDANCE California Industrial Hygiene Council 16 th Annual Conference Dan Gallagher Department of Toxic Substances Control California.
April , 2007 The Effect of Temperature on the Uptake Rates of a New PDMS-Based Permeation Passive Sampler for VOCs in Air Suresh Seethapathy, Tadeusz.
The Analysis of the FACT By Carl Keller Principal Scientist FLUTe.
Groundwater Dr. R. B. Schultz. Groundwater Groundwater is water, which originates from the infiltration of fluids through the soil profile and accumulates.
Lecture Notes Applied Hydrogeology
History and Cleanup at Chemical Commodities, Inc. Jeff Field US EPA Region 7 1.
New Bedford High School & Adjacent Properties Status of Off-Site Environmental Investigations - Public Meeting July 12, 2006.
Procedure for a conceptual design of a separation process 1. Definition of the separation problem 2. Accumulation of data of the substances involved 3.
1 Effective Characterization Technologies Deana M. Crumbling, M.S. Technology Innovation Office U.S. Environmental Protection Agency Washington, D.C. (703)
1 FUNDAMENTAL PRINCIPALS OF In Situ THERMAL TREATMENT Professor Kent S. Udell Department of Mechanical Engineering Department of Civil and Environmental.
Subsurface Water unit volume of subsurface consists of soil/rock, and pores which may be filled with water and/or air total porosity= volume voids/total.
Ground Water. Makes up 0.397% of Earth’s Water. - song.
1 LOCKFORMER ELECTRIC RESISTIVE HEATING CASE STUDY U.S. EPA Emergency Response Branch Steve Faryan, On-Scene Coordinator ,
Groundwater and NAPL Monitoring Oregon DEQ, Hart Crowser, Inc., and GSI Water Solutions 2010 McCormick & Baxter Annual Report.
Porewater: NJDEP Site Remediation Program regulatory perspective
GORE, GORE-TEX and designs are trademarks of W. L. Gore & Associates © 2007 W. L. Gore & Associates, Inc. 1 Environmental Investigations Using Versatile,
Ф Physical change from liquid to gas Ф 600 calories evaporate 1 gram H 2 O Ф Solar Radiation, Air Temperature, Vapor Pressure, Wind all affect rate.
Working With Simple Models to Predict Contaminant Migration Matt Small U.S. EPA, Region 9, Underground Storage Tanks Program Office.
The Water Cycle.
FULL - SCALE IMPLEMENTATION OF A PULSED AIR SPARGE AND SVE SYSTEM FOR TREATMENT OF VOCS, SVOCS, AND ARSENIC Authors: Kale Novalis, Nadira Najib, Omer Uppal,
بسم الله الرحمن الرحيم تلوث المياه الجوفية الناتج عن التسربات من خزانات الوقود المدفونة الخيار بين الوقاية والعلاج.
Groundwater Pollution
Water Cycle 1.Evaporation 2.Condensation 3.Precipitation 1.Liquid → Gas Liquid water changes into water vapor, which is gas. 2.Gas → Liquid Water vapor.
James River at Richmond, VA. Semi-Permeable Membrane Devices (SPMD’s) for Sampling Dissolved Organic Substances from Surface Waters Don Smith Virginia.
Groundwater Supply Dr. Martin T. Auer Michigan Tech Department of Civil & Environmental Engineering.
COMPARISON OF NATURAL SOURCE DEPLETION (NSZD) CHARACTERIZATION METHODS Mark Malander and Harley Hopkins (ExxonMobil) Andy Pennington, Jonathon Smith, and.
1 Groundwater Pollution GW 10 Monitored Natural Attenuation.
Groundwater Pollution
Groundwater KAUSHAL MODI ( ) JAYKUMAR PATEL ( )
Water Cycle and Groundwater
General Principles for Hydrocarbon Vapor Intrusion
Chemical Metals Industries, Inc. (CMI)
Daughter Groundwater Directive
Chemical Metals Industries, Inc. (CMI)
Olusola Ayilara, P.E., P.G. PST-DCRP Section, Remediation Division
Presentation transcript:

New Groundwater Techniques and Technologies 17 th Annual RETS REMP Conference June 25-27, 2007 Eric L. Darois, CHP EPRI Consultant/RSCS Inc.

2 © 2007 Electric Power Research Institute, Inc. All rights reserved. Project Scope Evaluate New and Current Technologies for Groundwater Sampling Evaluate New and Current Technologies for Contaminated Groundwater Detection Evaluate New and Current Technologies for Contaminated Groundwater Remediation

3 © 2007 Electric Power Research Institute, Inc. All rights reserved. Technology Conferences 7th Passive Sampling Workshop and Symposium, Reston Virginia, United States Geological Survey (USGS), April Ground Water Summit, Albuquerque New Mexico, National Ground Water Association (NGWA), April 2007

4 © 2007 Electric Power Research Institute, Inc. All rights reserved. Passive Sampling Technologies SPMD’s –Semi-Permeable Membrane Devices (SPMD’s) –These accumulate contaminants within an absorption media, typically a polyethylene absorption media. The Gore Module –Developed exclusively produced by and for GORE-TEX® –Similar to SPMD’s, does not collect a sample of water, uses a patented absorption material. –Consists of a tube of GORE-TEX® fiber containing absorption beads. –Has pore sizes large enough to allow volatile and semi-volatile gas phase contaminants to diffuse and to accumulate on the absorption material. –Pore size restricts liquid phase water from entering the sampler. PDBS –Passive Diffusion Bag Samplers (low-density polyethylene diffusion bag samplers) –Collects groundwater samples using a tube of Low Density Polyethylene (LDPE). –Fits into a 5 cm dia. well. –Filled with DI Water, sealed at both ends and lowered into Well. –Averages Concentration over 1 – 2 weeks – no additional equipment RCDMS –The Regenerated Cellulose Dialysis Membrane Sampler (RCDMS) –Similar to the PDBS. –Pore size between 5-20 microns. –May Be Susceptible to Degradation

5 © 2007 Electric Power Research Institute, Inc. All rights reserved. Passive Sampling Technologies (con’t) RPP –The Rigid Porous Polyethylene sampler (RPP) –Also Similar to PDBS and RCDMS –Porous polyethylene membrane with pore sizes ranging between 6 and 15 microns. –Limited to 100mL sample The Snap Sampler –Groundwater passive grab sampler. –Device consists of a sample bottle, trigger lines, end caps and springs –Sample Volumes of 40 and 125 mL. The Hydra Sleeve –Groundwater passive grab sampler. –Disposable thin-wall sleeve of polyethylene sealed on the bottom and fitted with a one way reed valve on the top. –Effectively Collects a Core of Water ~1000 mL

6 © 2007 Electric Power Research Institute, Inc. All rights reserved. Passive Sampling Comparisons Diffusion Sampler Grab Sampler Commercially Available Disposable Limited by Sample Volume Easy to Use Snap Sampler XXX RCDMS XX RPP XXXXX Hydra Sleeve XXXX

7 © 2007 Electric Power Research Institute, Inc. All rights reserved. Tritium Groundwater Contamination Detection Soil Vapor Extraction System (SVES) Current EPRI Research Initiative 4 Project Phases –1 Develop Predictive Model –2 Laboratory Testing of Model –3 System Test at a Decommissioning Site with Characterized H-3 Plume –4 System Test at Operating NPP Currently Beginning Phase 2

8 © 2007 Electric Power Research Institute, Inc. All rights reserved. SVES Basis Research Currently at the Armagosa Desert Research Site

9 © 2007 Electric Power Research Institute, Inc. All rights reserved. SVES Principle Extract Soil Vapor from Vadose Zone Condense Vapor, Analyze for H-3 The Vadose Zone H-3 Vapor “Plume” Likely Extends Well Beyond Contaminated Groundwater If the H-3 Vapor is Within the Extraction Zone of Influence, Detection will Occur. System May Provide Early Indication of H-3 Subsurface Leak.

10 © 2007 Electric Power Research Institute, Inc. All rights reserved. Project Objectives Determine Physical System Configuration Requirements Determined Required Data for System Installation Evaluate Sensitivity of SVES to “detect” Groundwater Contamination Provide for Data Assessment Methodologies Prediction of: –Soil Gas Velocity –Radius of Influence –Subsurface Release Activity

11 © 2007 Electric Power Research Institute, Inc. All rights reserved. SVES Model Principal Parameters –Soil Gas Velocity, –Air Permeability, and –Pressure Gradient.

12 © 2007 Electric Power Research Institute, Inc. All rights reserved. Model Assumptions The thickness of the vadose zone is relatively constant, homogeneous and isotropic within the extraction point’s ROI, i.e. construction backfill. An impervious or semi-pervious surface barrier to atmospheric gas transfer and direct infiltration of precipitation to the vadose zone is in place, i.e. pavement or concrete. A detection or change in condensate activity concentration is due to a soil vapor plume entering the ROI of an extraction point and is not the result of diffuse background H-3 activity in the soil. The approximate cross-sectional area OR volume of contaminated soil AND the approximate distance from the extraction point can be determined. Soil vapor within the capillary fringe of the liquid plume has the same activity concentration as the liquid release.

13 © 2007 Electric Power Research Institute, Inc. All rights reserved. Conceptual Design Each Extraction Capable of Covering Large Areas

14 © 2007 Electric Power Research Institute, Inc. All rights reserved. Specific Discharge and Capture Ratio Specific Discharge Within Plume Front Total Discharge at Plume Front, Q r Geometric Capture Ratio,

15 © 2007 Electric Power Research Institute, Inc. All rights reserved. Ideal and Non-Ideal Conditions System is More Effective with Concrete or Asphalt Cover

16 © 2007 Electric Power Research Institute, Inc. All rights reserved. Cylinder-Sphere Model – Non-Ideal Total Surface Area

17 © 2007 Electric Power Research Institute, Inc. All rights reserved. Additional Model Considerations Thick Vadose Zone 3-D Rendering to Determine Shape Surface Areas

18 © 2007 Electric Power Research Institute, Inc. All rights reserved. SVES Benefits Fewer GW Monitoring Wells More Effective Sentry System Onsite Analysis for H-3 More Effective Early Warning Methodology Less Dependent on Precise Placement Less Invasive (Push-Probe Installation Method) than Traditional GW Monitoring Well

19 © 2007 Electric Power Research Institute, Inc. All rights reserved. Project Schedule Phase 1 – Complete Phase 2 – 12/31/2007 Phase 3 & 4 – 12/31/2008