Page 1 company presentation 201223/11/2012 One Day National Workshop on Common Effluent Treatment Plants CII - Sohrabji Godrej Green Business Centre, Hyderabad.

Slides:



Advertisements
Similar presentations
Packaged Terminal Air Conditioners
Advertisements

Unit Seven: Pumps and Compressors
Fans and Blowers.
MAGNA3 – “built on a proven foundation”
07/08/2002 PP.AFD.02.MotorBasics 1 of 55 Yaskawa Electric America Motor Basics.
Mini Jet Sample Dyeing M/C Daelim Starlet Co., Ltd.
What is a centrifugal pump?
Propulsion Train & Shaft Line Components
Compressors CM4120 Julie King.
1 Engine Protector Safe Rider Vehicle Technologies (Pty) Ltd PO Box 11376, Rynfield South Africa Tel./ fax Cell:
Pumps, Compressors, Fans, Ejectors and Expanders
Basics of Pump Vigyan Ashram, Pabal.
Motors | Automation | Energy | Coatings. Howest Technical Seminar – 7 th October 2010 – Belgium Sebastião L. Nau.
Electro Mechanical System
Fifteenth Annual Vail Operator Training Seminar Understanding Centrifugal Blower Operation in Wastewater Aeration and Dissolved Oxygen Control Presented.
Distributor Training Session – Planetary Speed Reducers.
Air Compressors.
Pacific school of Engineering , surat A Presentation on
1. Footer Date Apresentação Técnica Compressores Estacionários CPG People. Passion. Performance.
Operation and Maintenance
Water piping design.
Perfect solution for large building
Gas Turbine Theory and Construction
automation 4 me TYPES OF LOAD 1 automation 4 me CONSTANT TORQUE LOAD : PERCENT SPEED NOTE:- A CONSTANT TORQUE LOAD IS NOT NECESSARILY 100% LOAD TORQUE.
Gas Turbine Theory and Construction. Introduction Comprehend the thermodynamic processes occurring in a gas turbine Comprehend the basic components of.
Introduction Compressor is a device used to produce large pressure rise ranging from 2.5 to 10 bar or more. A single stage compressor generally produce.
SURGE Compressor surge is an unstable phenomenon where the gas flow forward and backward across the machine alternatively. This phenomenon occurs at certain.
HYDRAULIC MOTORS.
Parul Institute of Engineering & Technology Subject Code : Name Of Subject : Fluid Power Engineering Name of Unit : Pumps Topic : Reciprocating.
PRINCIPLE & CONSTRUCTION OF HYDRAULIC PUMPS
Introduction to Energy Management. Week/Lesson 10 Air Moving Equipment: Fans and Ducts.
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Energy Saving Measures - 1
A Presentation On Construction Of Turbo Generator
1 ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 6 : PUMPS.
Designing Efficient Blower
Oil-free Vacuum Pump / Compressor Today’s Instruments Co., Ltd.
Positive Displacement Pumps
Chapter 3 – Hydraulic Pumps
AC Hydraulic and Pneumatic Systems1. AC Hydraulic and Pneumatic Systems2 Power train Mechanical power transmission: –Gears –Belt drive –Friction drive.
Prepare by :- Shivkumar Panjabi 1.  Introduction.  Types of compressors.  Positive displacement compressors.  Dynamic compressors.  Reciprocating.
Prepared By Rohit G. Sorte M.Tech
5-year operation experience with the 1.8 K refrigeration units of the LHC cryogenic system G. Ferlin, CERN Technology department Presented at CEC 2015.
FLUID POWER CONTROL ME604C. FLUID POWER MODULE:02 ~ HYDRAULIC SYSTEM COMPONENTS.
Internal Guide : Batch No : 4 Mrs.Punyavathi Madam
Advantages of Rotating Machines Less balancing problems Low lubricating oil consumption Higher reliability.
Kaeser Direct Drive CSD Rotary Screw Compressors
Miscellaneous Hydraulic Machine
1 Synchronous generators with permanent magnets for stabilization the output voltage of the power wind mill installations Tudor Ambros Professor, Technical.
Unit III Class II Pneumatic actuators.
Gas Turbine Theory and Construction
The New C55* CPVSd 10-20hp People. Passion. Performance.
Power Electronics and Control in Wind Energy Conversion Systems
YPPC’s Metallic MAG. DRIVE Process Pumps Product Overview.
Optimum Pump Performance for Process Applications
PNEUMATICS Chapter 3 ROTARY COMPRESSORS
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Ram-air, Superchargers, Turbochargers and Nitrous Oxide
Power Consuming Fluid Machines - II
Hybrid Transaxle.
HYDRAULICS & PNEUMATICS
Fluid Power systems Zonal hydraulics - industrial case 10 October 2017
Electric Machine Induction Motor
SPOC Automation and BECI- who are we?
ME444 ENGINEERING PIPING SYSTEM DESIGN
High Pressure screw compressor
Toshiba S-MMS vs LG MULTI V Plus II
SHANGHAI ROTORCOMP COMPRESSOR ONLY USE.
What is a Turbine ? A Turbine is a device which converts the heat energy of steam into the kinetic energy & then to rotational energy. The Motive Power.
Classification of air compressors. What are compressors? Compressors are mechanical devices that compresses gases. It is widely used in industries and.
Presentation transcript:

Page 1 company presentation /11/2012 One Day National Workshop on Common Effluent Treatment Plants CII - Sohrabji Godrej Green Business Centre, Hyderabad Technical Session II: Treatment Technologies & Monitoring 23 November 2012 Energy Efficient Turbo Blowers for Aeration Kiron C. Pande - Godrej & Boyce Mfg. Co. Ltd. Energy Efficient Turbo Blowers for Aeration Kiron C. Pande - Godrej & Boyce Mfg. Co. Ltd.

Page 2 Effluent Water Treatment

Page 3 Positive Displacement type, Twin Lobe Air Blower

Page 4 VolumetricTurbo Multi stage Turbo blower Low speed Turbo - η Increase over 10% - No Volumetric pulsation Efficiency Increased over 40% Blower Direct driven High Speed - η Increase over 10% -η Increase over 20% - Increase stability Increasing Energy Efficiency High Speed Turbo High Gear Ratio Multi stage Turbo blower Roots blower PD

Page 5 Turbo Blowers

Page 6 Energy Efficiency certified by: Korea Energy Management Corporation

Page 7 User selectable Control Modes with KTurbo Constant Flow Constant Pressure Constant Power D.O. Control

Page 8 User Selectable Control Modes

Page 9 Core Components & Salient Features Permanent Magnet Motor: a) Power required only to rotate & not for magnetizing of rotor; b) Can be started & stopped any number of times; c) High Efficiency even at part load No Gear Box: No transmission loss due to direct drive & no lubrication required. Variable Speed Drive for achieving high speed, smooth starts (reduced starting current) & energy efficient capacity control as part of the Blower package. Air Foil bearing for high speed operation (used in Jet engines) Oil Free air Low Noise: 80 dB against 100 dB of PD blowers Entire range is air-cooled & no need of water for cooling.

Page 10 Comparison with PD Blowers ParameterPD BlowerKTurbo Blower Aero Efficiency55%77% Drive Efficiency (Motor+Coupling+Invertor)82%92% Total Efficiency at 100% Load45%70% Total Efficiency at 50% Load22.5%67% Starting Current compared to Rated Current250%Below 5% MaintenanceOverhaulAir Filters Life5 YearsSemi- permanent Foot PrintLargeSmaller Noise Level dBBelow 80 dB

Page 11 PD Blowers Performance

Page 12  Typical model at 1800 RPM; Average total efficiency is 45% PD Blowers Performance

Page 13 PD Blowers Performance

Page 14 Single Stage Turbo Blowers Performance

Page 15 High Speed Turbo & PD Blower Performance

Page 16 High Speed Turbo & PD Blower Performance

Page 17 KTurbo (Benefits with KTurbo ) 1) Discharge Temperature : Less than 20° C than Roots type. => Change Aerated water temperature: less than 3 ℃ than with Roots blower used earlier 2) Capacity control : Operating 1 ㎥ /min => Protect for excessive aeration 3) Oil-less System => 100% oil-less air 4) Reduce energy consumption: more 40% (Before using roots blower) 5) Noise level : 1m (as against earlier 105dB with Roots blower) Aeration: Coca Cola (Korea)

Page 18 SunRiver: North America installation Before : 2 Units of 100hp Multi Stage After: 1 Unit of TB (70% Operation)

Page 19 Control Configuration for DO (Dissolved Oxygen) Intrinsic Feedback control DO data ( 4 ~ 20mA) Flow Control ※ DO Sensor (Endress+Hauser Co.) Input: ~ 60 ppm Output: 4 ~20mA HMI Display

Page 20 Schematic of KTurbo installation in WWTP plant

Page 21 Picture of KTurbo installation in WWTP plant

Page 22 Picture of KTurbo installation in WWTP plant

Page 23 KTurbo blowers supplying air to WWTP plant

Page 24 InverterPower In Controls Intake Silencer BOV Silencer Construction of Single & Twin Turbo Blowers / Comp

Page 25 PM Motor & Impellers 2 Pole permanent magnet (SmCo) with high strength retaining ring High performance electric core H Class Insulation winding Radial airfoil bearing Thrust disk & Thrust bearing Stainless steel casted Impeller Scroll Intake Discharge

Page 26 Core Technologies (1) Air foil bearings Self-acting hydrodynamic float on air Bump foil acting as a spring The first generation –Axially & circumferentially uniform elastic support elements The second generation –Variable axial OR circumferential compliance characteristics The third generation –Foil support in axial, circumferential AND radial direction

Page 27 History of Foil Bearings Simple Bump Reversed Multi-Layer Multi-Leaf High Capacity, High Speed, High Damping, High Temperature Multi-Pad Bump Third Generation Bump (KTurbo) Radial variation Circumferential variation Axial split/variation MiTi have made major research KTurbo has > 1000 units experiences KTurbo has TC series Teflon-S MoS2 High Temp Solid Lubricant -PS304 ; NASA -KOROLON1350F ; MiTi

Page 28 (2) High-speed & high-power PM motor/driver PM motors –High-speed & high-power (50 hp ~ 600 hp / 20,000 rpm ~ 70,000 rpm) –High efficiency (> 95%) Sensor-less Inverters –Cost-effective –High efficiency (> 97%) Core Technologies

Page 29 Why PM motor ?  No magnetizing power is necessary  Lower heat generation means less cooling loss.  Smaller rotor means less friction loss  No slip means high efficiency even at part load condition.

Page 30 Efficiency of PM motor & Induction Motor

Page 31 1.Stainless Steel SUS630, 17-4PH 2.Optimum Specific Speed Maximum efficiency 3.Optimum back sweep angle Maximum efficiency High Rise to surge Wide operating range 4.Splitter Blade Larger flow capacity Higher efficiency 5.Leaning Higher structural strength (3) Features of KTurbo Impeller Core Technologies

Page 32 Built-in Flow Meter Bell mouth is more accurate than Orifice, because it needs only one sensor.

Page 33 Discharge Duct Blow-off Valve Silencer Blower core Inverter Discharge pressure : P Discharge Temp : T2 Suction Flow rate dP : dP3 Suction Temp : T1 Filter Pressure Drop : dP1 Air Flow measuring Air in Air out Impeller Inlet Reducer T1 dP3 [Differential pressure] + Q ≈ Q (T1, Po, dP3) Measurement System

Page 34 HMI with touch screen

Page 35 HMI: Main Screen

Page 36 HMI: Operating Curves display

Page 37  CF memory is applied Data logging every 1 sec, 1 min, 1hour All event recording HMI: Data Logged every second

Page 38  CF memory is applied Data logging every 1 sec, 1 min, 1hour All event recording HMI: On-line trend display

Page 39 CCR (Central Control Room) SCADA or DCS or PLC MCP1 TB #1TB #2TB #3TB #4 MCP2 TB #1TB #2TB #3TB #4 Multi-Group Control

Page 40 Foundation Anchor bolting case-2 Anchor bolting case-1 Concrete pad

Page 41 Air Filters Pre 10 ㎛ 4-8 weeks Final 10 ㎛ or ㎛ 5-12 months ΔPΔP21-44mmWTR

Page 42 Customers

Page 43 Customers

Page 44 Thank You! Godrej & Boyce Mfg. Co. Ltd. Compressed Air Solutions Godrej | Electrical & Electronics Pirojshanagar, Vikhroli, Mumbai – India Tel.: to 2255 Fax: / s: