Motor Starter Coordination

Slides:



Advertisements
Similar presentations
Control Circuit Protection Supplementary Protectors vs
Advertisements

Electrical Installation
1 Building a New Electric World How can your LV electrical installation be rapidly designed and optimized?
SWITCHES, FUSES, & CIRCUIT BREAKERS
Three-Phase AC machines
Fuses vs Circuit Breakers for Low Voltage Applications
RMM Systems, LLC By Sam Rietta RMM Systems, LLC is a manufacturer's representative firm focused on providing value added sales solutions by providing.
© ABB Ltd - ATLV /26/2015 Insert image here Fuses vs Fuseless Technology.
Amp-Trap ® 2000 Fuse Family. 2 Amp-Trap 2000 ® When there’s absolutely no time for downtime.
Electrical Safety and Grounding Essentials Copyright © Texas Education Agency, All rights reserved.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
Proposed Design and the Operation of a Disconnecting Device for Small EG Installations Prepared by Hendri Geldenhuys.
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
Controlling Hazardous Energy
Flanders Electric – Engineering Division Welcomes Youto an Overview of Reconditioned Switchgear.
Protective Measures (CLUES) Proper G Proper G Use F, CB and GFCI G live parts G live parts L or T P U of flexible cords P U of flexible cords C electric.
Electrical Fundamentals
Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
SECTION 4 ELECTRIC MOTORS UNIT 19 MOTOR CONTROLS.
Section 4: Electric Motors
Vigyan Ashram, Pabal. Starter is a device which connects with motor in series to decrease the current at starting time and increase current after starting.
Chapter 3 Manual Starters.
Troubleshooting Electric Control Devices
Vidhyadeep Institute Of Management & Technology, Anita, Kim Electronics & Communication Department Guided by Mr. Vicky Paperwala.
Scheduled Versus Event Driven Testing of Distribution Protection IEDs Dr. Alexander Apostolov, Benton Vandiver, Will Knapek, OMICRON electronics.
ELECTRICAL HAZARDS Electricity is an essential of modern life Some work directly with electricity (Engineers, circuit assemblers) Some work indirectly.
Electrical Installation 2
Electrical Power Systems
7.1.3 Student Book © 2005 Propane Education & Research CouncilPage Applying a Systems Approach to Gas Appliance Troubleshooting Troubleshooting.
IP Other safety devices © Oxford University Press 2011 Other safety devices.
Grounding, bonding, and ground fault currents
Copyright  Progressive Business Publications Electrical Safety.
Residential Solutions New Square D QO ‘All-in-one’ & ‘Stand-alone’ Generator Panels Offer
Need for protection Power system must be kept in operation continuously without major breakdowns This can be achieved in two ways: 1.Implement a system.
Objectives Review conductor and conduit selection Learn about protection systems (basic rules) Learn to design Residential Electrical Systems.
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
Isolation Lock-Out Room Johns River Quarry Site Contact: Blake Ardrey, Quarry Manager, BCM, Johns River Quarry Phone:
SmartMQn Motor Horner APG, LLC September 9, 2008.
Basic Lockout Guidelines
Air Blast Circuit Breaker
What is Mechatronics? The portmanteau "Mechatronics" was first coined by Mr. Tetsuro Mori, a senior engineer of the Japanese company Yaskawa, in 1969.
Circuit Protection Unit 9.
Understanding Olympian Generator Set Schematics
Mersen’s Fused Coordination Panelboard
Circuits Electrical Wiring.
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
Overcurrent Protection— Fuses and Circuit Breakers
Agenda Introduction of Protective Relays
EET 323 – Electrical System Design Lecture 9: Grounding
Amp-Trap® 2000 Fuse Family.
Reduce Customer Down Times to a Maximum
Control of Hazardous Energy
Objectives Review conductor and conduit selection
The smart choice for demanding motor switching
Electrical components and systems
UL1077 UL508 UL489 They all look alike? What’s the difference?
0 Air Blast Circuit Breaker under the guidance of:- Presented By:- Mr. B.R.Reddy Anuj Kumar Pandey EN-3 rd year Roll No Unrestricted.
Basic Electric 3 HVAC Electric Components
Amp-Trap® 2000 Fuse Family.
Fuses vs Circuit Breakers for Low Voltage Applications
Presentation transcript:

Motor Starter Coordination -Implications -Benefits M Butler July 05

Coordination -A practical definition: “Selection of starter components: The short circuit protection element, (eg:Fuses/ Circuit breaker) The switching (Contactor)element The motor protection (Thermal Overload/ circuit breaker)element ..such that the occurence of a short circuit fault will result in a predictable outcome”. However different levels of coordination will lead to different results following a short circuit fault M Butler July 05

Type 2 coordination- Definition according to BS/EN 60947-4-1 « Effective limitation of the fault condition with no damage resulting to the components of the motor starter other than light tack welding of contactor main contacts which can easily be broken» However: 3 levels of coordination are considered by the standards Type 1 coordination to BS EN 60947-4-1 Type 2 coordination to BS EN 60947-4-1 Total coordination to BS EN 60947-6-2 M Butler July 05

BS/EN 60947-4-1 minimum requirements: Type 1 coordination Type 2 coordination Allows damage to all components when confined within their enclosure Allows tack welding of main poles (easily broken) and a change of O/L characteristics Allows only tack welding of main poles (easily broken) M Butler July 05

Type 1 coordination -minimum performance required following a short circuit fault: Damage to / destruction of starter components is acceptable, but there must be: No danger to personnel eg: ejection of damaged components from the enclosure (Note risk if panel door open & panel live) No damage to external installation, Effect of a short circuit fault: Downtime to replace components/ rebuild starter will be significant M Butler July 05

Type 2 coordination- minimum performance required after a short circuit Weld of contactor main contacts acceptable, provided weld is easily broken, and there must be: No damage to the installation No danger to personnel No need to replace components Effect of a short circuit fault: Downtime reduced, compared to type 1 coordination Checking contactor main pole contacts ( breaking tack welds if necessary) & replacing fuse links where used is required M Butler July 05

Total coordination is now a practical possibility To achieve type 2 coordination selection of the correct components is vital! Proven Type 2 coordination is the minimum requirement to ensure safety- But technology has moved on…….. Total coordination is now a practical possibility M Butler July 05

Requirements for Total Coordination for compliance with BS EN 60947-6-2 Starter must be a CPS (Control and Protective Switching) device. No damage to starter assembly acceptable Ongoing electrical life must be guaranteed No damage to the installation acceptable No danger to personnel acceptable Equipment may immediately be reset and restarted, once short circuit fault removed Effect of a short circuit fault: Minimal downtime. -Removal of fault followed by resetting and restarting of equipment is all that is necessary M Butler July 05

Telemecanique independently certified CPS Motor starters with Total coordination Single product solution TeSys model U up to 32A Single product solution with diagnostics Tesys model U with Multi- function module Single product solutions with AS-I capability Tesys model U with AS-i module Single product solutions with diagnostics and full communications capabiilty Tesys model U with Multifunction module and Modbus or Canbus coms module M Butler July 05

Tesys model U provides unique benefits enabling maximisation of machine uptime Total coordination Minimum downtime following fault No damage to installation following a fault No reduction in service life Easier selection of correct components to ensure integrity of the installation Diagnostics capability- Retention and downloading of data: Last 5 trip occurences Reason for trip- (short circuit or thermal) Total no hours run No of operations M Butler July 05

Summary Effective coordination of starter components is essential for safety and minimum downtime following a short circuit fault Type 1 coordination must be considered unacceptable for all but the simplest installations where downtime in the event of a fault is not critical Type 2 coordination can reduce downtime in the event of a short circuit fault, but requires careful selection of components Total coordination virtually eliminates downtime due to short circuit faults. Selection of a CPS device is simple M Butler July 05