RMM Systems, LLC By Sam Rietta RMM Systems, LLC is a manufacturer's representative firm focused on providing value added sales solutions by providing.

Slides:



Advertisements
Similar presentations
POWER QUALITY BACKGROUND & ELEC-SAVER TVSS
Advertisements

Inspection & Preventive maintenance of breakers
Three-Phase AC machines
07/08/2002 PP.AFD.02.MotorBasics 1 of 55 Yaskawa Electric America Motor Basics.
E2 Motors and Motor Starting (Modified)
Refrigerators.
Power Quality & Energy Efficiency: A Solution to Climate Change 1 st POWER QUALITY ASIA CONFERENCE November 14 & 15, 2012 SMX Convention Center, Manila.
Motors & Motor Starters
Flanders Electric – Engineering Division Welcomes Youto an Overview of Reconditioned Switchgear.
Generator Protection. Amount of Protection Rated power of the generator Ratio of its capacity to the total capacity of the system Configuration of the.
PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
©2004 Fluke Corporation Insulation Resistance Testing 1 Insulation Resistance Testing.
1111Challenges for reliable offshore transformersTRANSFORMING YOUR NEEDS INTO SOLUTIONS Challenges for Reliable Offshore Transformers Dr. Jan.
SECTION 4 ELECTRIC MOTORS UNIT 19 MOTOR CONTROLS.
PRESENTED BY Toshiba International: Mike Tharp Hupp Electric Motors: Dave Patterson.
Department of Mechanical Engineering HumilityEntrepreneurshipTeamwork LearningSocial ResponsibilityRespect for Individual Deliver The Promise BS&H, GMR.
Section 4: Electric Motors
Take 5 for Safety E. Lessard April 14, Power Disturbance on Sixteen 3-Phase Motors Failed due to “Single Phasing” 2 Arrow pointing to.
EGD ELECTRICAL ELECTRICAL SYMBOLS.
AC MOTOR INDUCTION MOTOR.
Chapter 3 Manual Starters.
Motor Control Center MNS iS with Condition Monitoring
Chapter 2 Transformers.
Troubleshooting Electric Control Devices
Motor Start Theory ME00107A.
Two Minute Drill #8 Copyright 2005 Ted "Smitty" Smith Practice Code Look Up.
Electrical Installation 2
UNIT 18: APPLICATIONS OF MOTORS
Motor Testing (Motor Only)
Chapter 17 DC Motors. Objectives After studying this chapter, you will be able to: Explain the principles upon which DC motors operate Describe the construction.
POWER SYSTEM PROTECTION
Electric Motors Applications of Motors North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed., CMHE Motors - 1.
Misalignment of sheaves and couplings
Why Maintenance Tasks are Important Produced by Joe Marchese.
Utility Engineers, PC.  Generation  Transmission  Distribution.
23,000 students trained since 1980 Electrical maintenance, troubleshooting and safety courses Safety programs, procedures and arc flash studies Leadership.
DEMAS ENGINEERING SERVICES LIMITED. The Condition Based Monitoring maintenance Experts Our Vision To be the most sought after provider of high quality,
Introduction to switchgears
SERVICE ENTRANCE EQUIPMENT
SmartMQn Motor Protective Functions Ken Jannotta Jr. Horner APG, LLC.
Modern Maintenance. Management
EFFECTS OF VOLTAGE IMBALANCE ON 3-PHASE INDUCTION MOTORS DESIGN TEAM 3.
April Motors 1011 of 55 Dykman Electrical 5 April 2013.
SARDAR VALLABHBHAI PATEL INSTITUTE OF TECHNOLOGY PREPARED BY: 1)BALDIWALA ALIABBAS ( ) 2)PARTH GUPTA ( ) 3)ANIL KHATIK ( )
REDA Production Systems
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
Design of starters for AC motors C.K. PITHAWALA COLLAGE OF ENGINEERING & TECHNOLOGY Group no - 3 Name Enrolment no Chaudhari Darshan M Chaudhari.
Power Quality Issues Power Electronics Group.
6/30/2016EMC: AC Motors Roger Enns1 AC 6/30/2016EMC: AC Motors Roger Enns2 AC Motors Summary.
TITLE- BUCK BOOST TRANSFORMER BY- NEERAJ S ABHYANKAR SEMINAR GUIDE- H.O.D.Mrs.M.H.DHEND.
III ALTERNATING CURRENT Electricity is generated, transmitted, and used in the form of three-phase alternating current (AC). The current strength of AC.
Protection and Relay Schemes
Unit – IV Starting and Speed control of Three phase Induction motor
Electric Machine Induction Motor
Induction motor control
2017 Fall Educational Forum Bruce A. Tagg, ALCM
ACTIVE LEARING ASSIGNMENT
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
Why is starter necessary for a three-phase induction motor?
Engineering Project Cable Management.
UNIT II APPARATUS PROTECTION.
Agenda Introduction of Protective Relays
Equations, Performance, Electrical Equivalent Circuits
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Presentation transcript:

RMM Systems, LLC By Sam Rietta RMM Systems, LLC is a manufacturer's representative firm focused on providing value added sales solutions by providing customer service, technical support and application assistance to our customers, design engineering firms and specification authorities. It is our goal to provide a high degree of professionalism to complement the image and objectives of the leading manufacturer's of electrical equipment we represent.

Have you ever lost a motor? Caused a loss of production? After a storm? Same motor over and over again? While you were away from the plant? Something happened on the power company side. Didn’t know why?

Why Do Motors Fail? Common Causes of Motor Failures

Costs Associated with Motor Failures Equipment downtime $$$$ Loss of production Collateral equipment damage Equipment replacement Work in process damage Overtime for repair crews

Motor Windings Breakdown Thermal Mechanical Environmental

Thermal Breakdown Rule of thumb: A 10 o C temperature rise above rated temperature will half the life of a motor Motor operating temperature is based on: 40 o C ambient temperature Class B Insulation limit is 130 o C Class F Insulation limit is 155 o C

Thermal Breakdown Causes: Overload Voltage Variations Single Phasing Short Cycle Lightning and Surges Improper Ventilation Dirt & Dust Accumulation

Mechanical Breakdown Causes: Bearing failure resulting in rotor or stator rubbing insulation off Vibration Improper Alignment

Bearing Failure Causes Improper lubrication Excessive belt tension Mis-alignment

Environmental Breakdown Causes: Moisture / Water Corrosion/ Chemicals Rodents & Insects Age

Causes of Motor Failures 44 % of all motors failures are due to overloads and single-phasing.

Why Motors Fail... * Based on 9,000 failure events researched by the Electric Motor Manual which was written by Robert Lawrie in conjunction with the staff at Electric Construction and Maintenance Magazine. Rotor Failures 5% Failures Bearing 13% Contaminants 19% Overload 30% Misc 9% Single Phasing 14% Old Age 10%

Number One Motor Failure… Overload! Overload 30%

Overloads “ It is practically impossible to burn out a motor from overload when it is protected by properly sized and maintained motor protection devices”. William P. Maples, P.E.

Motor Service Factor Motor service factor of 1.15 means that the temperature rise of a motor will not exceed design temperature even if the motor is carrying a continuous overload of 15%

U.L and IEC Test Procedures U.L. 508 Determines test procedures for motor starters. U.L. Short Circuit test procedures –Starter door cannot be blown open –Contacts must not disintegrate –Overload burnout is allowed with breaker tests.

Short Circuit Protection of Motor Controllers

IEC Standards IEC Publication 947 “Low Voltage Switchgear and Control”

IEC Levels of Motor Starter Protection Type 1 Protection. –No discharge of parts beyond the enclosure is allowed –Damage to the contactor and overload relay is acceptable

IEC Levels of Motor Starter Protection Type 2 Protection. –No damage is allowed to either the contactor or overload relay –Light contact welding is allowed, but must be easily separable

Voltage Voltage Variations Phase imbalance Phase loss (Single Phasing)

Voltage Variation Nema Standards states that motors shall operate successfully at rated load under the following conditions: +/- 10% variation of rated voltage at rated frequency Any voltage drop below 10% will reduce starting torque which can be serious because starting times may increase beyond allowable limits. Winding failure from extreme voltage variations are identical to those of overloads because the input current is uniformily excessive.

Low Voltage… Cause Demand for power is greater than the supply Long cable runs Overloaded transformers Distribution system

Low Voltage… Effect Reduced efficiency Reduced life expectancy Increased temperatures Increased current Lower torque

High Voltage… Definition Operating a motor above 110% of nameplate voltage

High Voltage… Cause Poor line regulation Incorrect transformer tap Utility demand down

High Voltage… Effect Reduced efficiency Reduced power factor Increased power consumption Increased current Increased temperature

Voltage Unbalance Percent voltage unbalance = 100 x Maximum voltage deviation from average voltage average voltage

Voltage Unbalance example: Assume voltages to a motor are 228 V to Phase A, 220V to Phase B and 236 V to Phase C. The average voltage is 228 V. The voltage unbalance is as follows: Voltage imbalance = x 100 = 3.5% 228

Effect of Voltage Unbalance on Motor Longevity

Effects of Voltage Unbalance Horsepower Derating

Another Rule of Thumb …………. A 3.5% voltage unbalance will cause a 25% temperature rise. An increase in temperature rise in the phase with the highest current is 2 times the square of the voltage imbalance

Causes of Voltage Unbalance: Unequal loading of a three phase system Unequal tap settings on transformers Loose connections in the power system Damaged starter contacts Open delta transformer systems Storms (wind, fallen trees, lightning) Poor regulation by utility

Example of heat rise due to voltage variations 50 HP Motor Heat rise 60 o C Ambient Temperature 40 o C 8% Unbalance Effect: 76 o C (8x8=64 x 2= 128% x 60 o C= 76 o C) 176 o C Result: Motor Failure

14% of All Motor Failures - Single Phasing Single Phasing 14%

Secondary Single Phasing

Causes of Secondary Single Phasing Damaged motor starter contact Burned open overload relay Damaged switch or circuit breaker Blown fuse Open cable or bus on transformer secondary Open motor winding Open transformer winding

Primary Single Phasing

Causes of Primary Single Phasing Open line on primary –Storm (wind, ice, fallen trees, lightning) –Vehicle striking utility pole –Construction mishaps Blown Primary fuse Open contact on utility contactor or re-closer Open winding on transformer

In conclusion : Motors will last a long time if operated within their design parameters. ( Voltage, current & temperature) Identify the cause of your motor failure When replacing motors also consider changing overloads and motor start contacts For critical motors incorporate the latest motor monitoring products. RMM Systems

Thank you! From RMM Systems