Who is Stellar Tech?  Stellar Tech Energy Services is a wholly owned Canadian company  Manufacturer of WellMax Datalogger / Controller  Specializing.

Slides:



Advertisements
Similar presentations
MEDIUM VOLTAGE VFD MOTOR CONTROLLER Liquid Cooled Components Active Front End - No Transformer 3300 – 6900 VAC 700 – 2500 HP Contact:
Advertisements

Ch8 Inverters (converting DC to AC)
New Energy Horizons Opportunities and Challenges Fault Current Contributions from Wind Plants Dean Miller PacifiCorp July 25,
QUALITY AND TECHNOLOGY
Siemens Building Technologies Building Technologies Variable Frequency Drives Harmonics Overview.
Chapter 4 DC to AC Conversion (INVERTER)
RMM Systems, LLC By Sam Rietta RMM Systems, LLC is a manufacturer's representative firm focused on providing value added sales solutions by providing.
Power Quality & Energy Efficiency: A Solution to Climate Change 1 st POWER QUALITY ASIA CONFERENCE November 14 & 15, 2012 SMX Convention Center, Manila.
VARIABLE SPEED DRIVES HARMONIC EFFECTS & EFFECT OF USE WITH LONG CABLES (100 – 300m) Electric Motors & Drives ….OUR VISION, YOUR SOLUTION ……. TOGETHER.
2010 ASHRAE Rocky Mountain Chapter VFD Fundamentals April 16, 2010 Jeff Miller - ABB © ABB Month DD, YYYY | Slide 1 1.
© Copyright 2008 ABB. All rights reserved /29/2008 Results-Driven Roadshow Cincinnati, 2008 Common Cures for Harmonics Larry Stanley RSE,Nashville,TN.
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900E PUBLIC INFORMATION May 2014 TechConnect Genius Webinar AC Variable Frequency.
©2004 Fluke Corporation Introduction to Motor Troubleshooting 1 Introduction to Motor Troubleshooting.
Variable Frequency Drives VFD Basics
This lesson covers the following outcomes Unit 54 P1, P7, P8 Unit 6 P10, P11.
7154 VFD Presentation #3 May 2002 Paul Weingartner.
KW Energy Solutions, LLC Increasing Energy Efficiency Increasing Energy Effectiveness.
Application Types Variable Torque Constant Torque.
PSI Pump Systems Inc. 1(800) PSI Pump Systems Inc. 1(800) Variable Frequency Drives Presented by PSI Pump Systems Inc. “ Your Solutions.
Dry type transformers Zaragoza Traction application
EXCITATION SYSTEM.
PENTAIR 1.
SPEED CONTROL OF THREE PHASE INDUCTION MOTOR WITH ENERGY SAVING
WISA Meeting Help Arrange a Speaker, Write Bio, Introduce
7154/7156 Variable Speed Drives
Three-Phase AC machines Three-Phase Cage Rotor Induction Motor – Electronic Methods of Starting and Speed Control Resource 4.
Chapter 8 Inverters AC Power • Inverters • Power Conditioning Units • Inverter Features and Specifications.
PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
REFLECTED WAVE TRAP - A Quantum Leap in Motor Protection
Considerations for Selecting VFD’s Quentin Nesbitt, PE Agricultural Engineer Idaho Power Company.
Copyright © 2008 Rockwell Automation, Inc. All rights reserved. Direct-to-Drive Technology Product Feature Overview.
ET3380 Principles and Methods of Electric Power Conversion David Morrisson MS,MBA Week 1.
New England Association Of Fire Protection System Designers Rick Dumont.
ECE Electric Drives Topic 10: Cycloconverters Spring 2004.
Diode Theory and Application
2. Terms and definitions1 # Terms and Definitions # Voltage Sags and Interruptions.
InnovationValueTeamwork SHENZHEN INVT ELECTRIC CO., LTD.
7154 VFD Presentation #2 May 2002 Paul Weingartner.
Motor Testing (Motor Only)
Applied Harmonics Control of Harmonics
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
MonoDrive & XT Constant Pressure Controller
Variable Frequency Drives and Irrigation Pumps Stefanie Aschmann Bozeman, MT 11/30/11 1.
COMPACT Variable Frequency Drives. Honeywell Proprietary Honeywell.com  Buildings Consume Massive Amounts of Energy Commercial Buildings consume massive.
Voltimum Expert Topic – Power Harmonics. What are Harmonics? They are waveforms with frequencies that are multiples of the fundamental frequency (Typically.
CUE – Make Any Pump an E-Pump
7/08/2002PP.AFD.07 Harmonic Quality1 of 49 Yaskawa Electric America Harmonic Currents, Voltages and Your Building Power System.
Chapter 9 CAPACITOR.
Power Quality Issues Power Electronics Group.
Yaskawa Training Café Yaskawa Training Café – Through the Combined Efforts of Drives Engineering and Technical Training Services Welcome n To make this.
Variable Speed Fire Pump Controllers - by - James S. Nasby Columbia Engineering.
Copyright © 2009 Toshiba International Corporation. All rights reserved. Hx7+Pack Drive Severe Duty Adjustable Speed Drive Prepared By: ASD Marketing.
Review of ABB Drives. 1.Direct torque control explains what DTC is; why and how it has evolved; the basic theory behind its success; and the features.
Energy Efficient Motors and Variable Speed Drives
Speed control of three phase induction motor
MEDIUM VOLTAGE APPLICATIONS.
Yaskawa Electric America on Variable Torque Loads
SPOC Automation and BECI- who are we?
High Voltage Coil with Extra Insulation on initial turns
DC- AC CONVERTER-INVERTER
APPLICATIONS Reference: Textbook-Chapter 6,8 & 9 'Power Electronics',C
Monitoring Electrical Health of ESPs: What Are Your Measurement Options? By Anthony Thornberry Presented at the Mid-Continent Digital Oilfield Conference.
Robicon Perfect Harmony.
UNIT-8 INVERTERS 11/27/2018.
Switch-Mode DC-AC Inverters
Induction Motor Drives
AC Drives Dr. Adel A. El-Samahy Department of Electrical Engineering University of Helwan.
INVERTERS. What is an Inverter? A static device that converts DC power into AC power at desired output voltage and frequency is called an Inverter. Applications.
Presentation transcript:

Who is Stellar Tech?  Stellar Tech Energy Services is a wholly owned Canadian company  Manufacturer of WellMax Datalogger / Controller  Specializing in the integration and distribution of VFD’s and motors.  Strengths in Pumping Systems  Oil, Water, and Municipal

What we do!  Oil & Gas production pumping  Commercial Pumping  Municipal Pump Controls  Datalogging and Control  Work in a Global Market

Our Capabilities  Variable frequency drive (VFD) systems design and integrator.  Over 15 years experience in drives and automation  Thousands of successful installations  Complete systems integrator with design, manufacturing, start-up and service capabilities

Our Products  WellMax Datalogger  Variable Frequency Drives  Down hole Pressure / Temperature Recorders

Our Strengths  All products are manufactured to the highest quality standards  Knowledgeable customer service representatives and technical support groups  Worldwide commitment to customers with sales and service facilities around the globe

WellMax Datalogger / Optimizer / Controller  Designed and engineered for pumping applications to optimize production  Can be used with VFD’s, Hydraulics or Across the line / Motor starter. Extensive options available  Drive / motor control

WellMax Features  Rod protection  Well OPTIMIZATION  Immediate data storage and retrieval  Fluid level control  Pump off  Multiple communication features and protocols  Trend analysis  Screen for on-site data viewing

Well Conditions WellMax Data Logger and Controller

LEVEL AND RPM CONTROL Equimavenca – Capital Nacional Levantamiento Artificial / Servicio Integral Equimavenca – Capital Nacional Levantamiento Artificial / Servicio Integral

Pump Off – Complete Overview A–SPEED CHANGE B-PRESCO FAULT C-POWER BUMP D-PRESCO E-BROWN OUTS F-PUMPOFF SIGNS G-PUMPOFF OCCURS LEADING UP TO A PUMPOFF CONDITION

A - Speed Change

B - Presco Fault

C - Presco Fault

D - Power Bump

E – Power Brown Outs

F – Signs of Pump-off or Pump Damage

G – Pump-off occurs

Tubing Leak Torque fluctuations are caused by excess volume of gas Significant drop in torque displays tubing leak

Tubing Leak Significant drop in torque displays tubing leak

Tubing Hair line fracture The increase of RPM caused enough pressure to open up the hair line fracture in the tubing, flow decreased but never completely stopped

Sand Avalanche Pump slowly filling with sand Pump is full of sand

Pumped Off Well Pump Off Occurs 80 Ft Lbs 75 Ft Lbs

Waxing Condition

Parted Rods

WellMax Menu Structure

SUMMARY REPORT

NEMA 3R Panel

VERTICAL NEMA 1 Unwired 3 Contactor Bypass Package Showing Fused Disconnect Line Reactor Contactors O/L

IEEE 519 The total harmonic voltage distortion at any point of common coupling with a nominal voltage of less than 66kV shall not exceed 5%. Point of Common Coupling (PCC): That busbar electrically closest to any consumer through which any current must flow to that consumer and one or more other consumers.

Uncontrolled Rectifier Harmonics Line 1 Line 2 Line 3 LOAD D1 D2D3 D4 D5D6 Current in D1 Current D1 & D5 Current D1 & D6

Square Wave Harmonics Content Square wave & Fundamental + 3rd

Types of Harmonic Filters  A VFD with no input reactor or filter may result in 100% THID or more, measured at the VFD input terminals  A 3%Z line reactor will limit THID to 35~ 40%  A 5%Z line reactor will limit THID to 30 ~ 35%  A 5%Z line reactor & 3%equivalent Z DC reactor will limit THID to 25~30%  Tuned 5 th harmonic trap will limit THID to 20 ~ 25%  12 pulse phase shifting will reduce THID to a minimum of full load  18 pulse phase shifting will reduce THID to a minimum of full load  Matrix wide spectrum filter limits THID to 8% or 5% at full load

Input Current – Enhanced 5 th Harmonic Trap (w/VFD input reactor) Load: 100% Input Voltage: balanced Line Impedance: 0.25% Input Reactor: 5% Output Reactor: 1.5% Input Current THID: 23.07%

THID Performance 8% Filter

12 Pulse w/ 1% & 3% Line voltage unbalance Matrix w 1% & 3% Line voltage unbalance Matrix Filters perform better than 12-pulse under Real Life operating conditions (unbalanced line voltages, 0% to 100% loading)

6-pulse VFD with 5% Matrix Filter performs better than 18-pulse drive under normal operating conditions (0% to 100% load, voltage unbalance)

Voltage Unbalance….. ANSI Standard C Reports: 98% of power systems are within 1 - 3% 66% of power systems are within 0 - 1% –all at the point of common coupling Load unbalance within the building power distribution system adds to the utility unbalance at the point of utilization.

Reducing Harmonics  Ensure a low network Impedance  Distribute harmonic generating loads  Use AC line or DC link reactors  Install Harmonic filters

IEEE – 519 Solutions Desired % THID at PCC (IEEE- 519) 3% Line Reactor 5% line Reactor 5% Line + 3% DC Reactors 8% Matrix Filter (M8) 5% Matrix Filter (M5) % Maximum VFD Load if all VFD’s use same Harmonic Mitigation Method

Motor Inverter Compatibility Topics  Reflected Wave Theory  Waveform Analysis with output reactors & filters  Long Motor Leads  Drive Solutions  Motor Solutions

Reflected Wave Theory Mismatch between surge impedance of: Drive-to-motor cable & Motor winding  Cable surge impedance fairly constant through hp range  Motor surge impedance inversely proportional to hp  2 per unit voltage evident on motors up to 500 hp  Motor terminal voltage doubling on leads over 15 feet

Full Voltage, 60 Hz PWM Waveform Half Voltage, 30 Hz PWM Waveform PWM Waveform

VFD Output & Motor Terminal Voltage, Reflected Waves

IGBT VFD, Motor Terminal Peak Voltage & Rise Time Characteristics  Peak voltage = twice DC Bus voltage at critical cable length and longer. DC bus voltage = AC input voltage *  e.g. 600 VAC * = 850 * 2 =1,700 V Peak.  Rise time = 0.015uS to 1uS Depending on IGBT Current Rating  Critical cable length = speed of propagation * rise time.  e.g. 150meters/uS * 0.03uS = 4.5 meters

IGBT VFD, Motor Terminal Voltage, 10 HP, 460 Volt, 6 KHz Carrier Frequency, 60 Hz Output Frequency, No Load Reactor, 10 Feet of Cable, Peak Voltage 1,200 Volts, Rise Time.03uS

IGBT VFD, Motor Terminal Voltage, 10 HP, 460 Volt, 6 KHz Carrier Frequency, 60 Hz, 3%Z Load Reactor, 10 Feet of Cable, Peak Voltage 820 Volts, Rise Time 2uS

IGBT VFD, Motor Terminal Voltage, 10 HP, 460 Volt, 6 KHz Carrier Frequency, 60 Hz Output Frequency, Sine Wave Output Filter, 10 Feet of Cable, RMS Voltage 460 VAC, No Spikes

IGBT VFD, Motor Terminal Voltage, 10 HP, 460 Volt, 6 KHz Carrier Frequency, 60 Hz Output Frequency, No Load Reactor, 250 Feet of Cable, Peak Voltage 1380, Rise Time.05uS

IGBT VFD, Motor Terminal Voltage, 10 HP, 460 Volt, 6 KHz Carrier Frequency, 60 Hz Output Frequency, 3%Z Load Reactor, 250 Feet of Cable, Peak Voltage 1,000 Volts, Rise Time 10uS

IGBT VFD, Motor Terminal Voltage, 10 HP, 460 Volt, 6 KHz Carrier Frequency, 60 Hz Output Frequency, Sine Wave Output Filter, 250 Feet of Cable, RMS Voltage 460 VAC, No Spike

Long Cables  From critical cable length and longer, motor terminal voltage remains at 2 per unit  Time spent at 2 per unit voltage increases with cable length therefore transient energy level much higher  Insulation stress much higher  proportional to transient energy*carrier frequency

NEMA Minimum Design Standards For 3 Phase Induction Motors MG1 part 30 As a minimum motor insulation must withstand  1000 volt  2uS rise time MG1 part 31 As a minimum motor insulation must withstand  1600 volt  0.1uS rise time

VFD Solutions For NEMA MG1 part 30 Motors  No output reactor or filter required for 208/240Volt applications  Use output reactor for 460 volt applications  Use output dv/dt filters for 575 volt applications  Keep motor leads short  Keep carrier frequency low  Keep motor cool

Motor Solutions For NEMA MG1 part 31 Motors  No output reactor or filter required for 208/240 volt applications  No reactor or output filter required for 460 volt applications unless cable length is extreme  Use output reactor for 575 volt applications

END OF PRESENTATION THANK YOU