PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 1 MPE J. Schubert PACS IHDR.

Slides:



Advertisements
Similar presentations
PACS IIDR, Noordwijk 1-2 Mar 2001 Chopper R. Hofferbert D. Lemke, U. Grözinger, O. Krause, U. Klaas J. Katzer (ZEISS) Max-Planck-Institut für Astronomie,
Advertisements

Manchester 09/sept/2008A.Falou & P.Cornebise {LAL-Orsay}1 CALICE Meeting/ Manchester Sept 2008 SLAB Integration & Thermal Measurements.
MP Prototype 2 1IWF-EXP/ÖAW GRAZ  Smaller Size  Outcome of the test results with MP-P1 was the need for a reduced cross section  Rectangular Shaped.
Reproduction interdite © ALMA EUROPEAN CONSORTIUM Reproduction forbidden Design, Manufacture, Transport and Integration in Chile of ALMA Antennas Page.
PACS IHDR 12/13 Nov 2003 Photoconductor Detector Modules 1 IHDR ASTEQ-GmbH Germany Peter Dinges, Michael Harr, Heribert Krüger, Hilmar Richter, Bernd Zimmermann.
Test Cryostat, OGSE and MGSE PACS IHDR: MPE 12/13 Nov 2003 AIV1 PACS Test Cryostat, OGSE and MGSE Gerd Jakob MPE.
23 October 2005MICE Meeting at RAL1 MICE Tracker Magnets, 4 K Coolers, and Magnet Coupling during a Quench Michael A. Green Lawrence Berkeley Laboratory.
PACS IBDR 27/28 Feb 2002 Photoconductor Detector Arrays1 IBDR Hilmar Richter ANTEC-GmbH Germany Günter Bollmann, Peter Dinges, Otto Frenzl, Heidrun Köppen,
Heat Transfer Overview
Background to the current problem 1. As a result of the high stresses in the bobbin due to the magnet load, the bobbin end plate needs to be increased.
ISHELL Design Review Cryostat & Optics Bench Dan Kokubun 9/11/2013.
Fcal upgrade for sLHC: Cryogenics modifications – TE-CRG/ C.Fabre 1 ATLAS FCal Upgrade for sLHC: Modifications to the Calorimeter Cryogenic.
PACS IHDR 12/13 Nov 2003 PACS FPU Optics: Concept and Alignment R. Graue, D. Kampf Kayser-Threde.
PACS IBDR 27/28 February 2002 PACS DEC/MEC1 Detectors & Mechanisms Controllers (DEC/MEC) J.-M. Gillis Centre Spatial de Liège (B)
PACS IHDR MPE 12/13 November 2003 AIV 1 PACS IHDR Integration, Qualification and Testing Reinhard Katterloher.
PACS IBDR 27/ BOLC/BOLA1 BOLC / BOLA SAp/DAPNIA/DSM/CEA C. CARA WE Design Team: A. BOUERE - N. DEVIN - G. DHENAIN - E. DOUMAYROU M. SEYRANIAN -
TSU F.E ANALYSIS YAIR SOFFAIR. Ojective Dynamic Response Calculation Temperature Distribution LOS Retention due to Temperatures Design Recommendations.
PACS IHDR 12/13 Nov 2003 PACS FPU Distribution Boards and FPU Harness Concept R. Graue, D. Kampf Kayser-Threde.
Presentation EddiCam consortium, FF, Madrid 13/06/2002 Eddington programmatic status Fully approved by SPC as part of ESA’s science program as project.
PACS IBDR 27/28 Feb 2002 PACS Photometer1 PACS PHOTOMETER J.L Auguères L.Rodriguez CEA/DSM/DAPNIA Service d’Astrophysique.
Pixel Support Tube Requirements and Interfaces M.Olcese PST CDR: CERN Oct. 17th 2001.
VELO workshop, Amsterdam, april ‘00M.Ferro-Luzzi Difficulties with current mechanical design recent FEA results: to obtain sufficient stiffness of center.
PACS IIDR 01/02 Mar 2001 Instrument Interfaces1 PACS FPU Opto-mechanical Design Overview and Interfaces J. Schubert MPE.
PACS IHDR 12/13 Nov 2003 PACS FPU FPU Structure, Baffle and Straylight R. Graue, D. Kampf Kayser-Threde.
PACS IBDR 27/28 Feb 2002 IIDR Close-out1 Close-out of IIDR Recommendations A. Poglitsch.
PACS IBDR, Garching 27/28 Feb 2002 Chopper R. Hofferbert D. Lemke, U. Grözinger, O. Krause J. Katzer (ZEISS) Max-Planck-Institut für Astronomie, Heidelberg.
FIRST/Planck 12 December 2000PT The FIRST Mission Implementation Status and Schedule T. Passvogel The Promise of FIRST.
PACS IHDR 12/13 Nov 2003 IBDR Close-out1 Close-out of IBDR Recommendations A. Poglitsch.
What are common results of heat transfer? Case #1, no phase transition or work done. How much does the temperature vary? Heat is energy in transit! Positive,
PACS INSTRUMENT HARDWARE DESIGN REVIEW CEA-Grenoble / DSM / DRFMC / SBT / HSO Cryocoolers/ PACS IHDR1 MPE - November, HSO SORPTION COOLERS Lionel.
PACS IQR 13 Jan 2005 First Assessment1 The PI’s Self-Assessment A. Poglitsch.
PACS SVR 22/23 June 2006 PACS FPU Subunits1 FM FPU Subunits A. Poglitsch.
PACS IQR ESTEC 13 January 2005 Mech Qual Status 1 PACS IQR Mechanical Qualification Status and Plans for PFM Reinhard Katterloher R. Graue, D. Kampf, R.
CLIC Implementation Studies Ph. Lebrun & J. Osborne CERN CLIC Collaboration Meeting addressing the Work Packages CERN, 3-4 November 2011.
Herschel/Planck January 13, 2005PACS IQR - SCI-PT/ ggonzale: Herschel PACS Instrument Qualification Review Review Objectives and Organisation G.Crone/G.Pilbratt.
Spectrometer Solenoid: Plans to Fix Magnet 2 Steve Virostek Lawrence Berkeley National Lab Spectrometer Solenoid Review November 18, 2009.
PACS SVR: 22/23 June 2006 MPE - Ge:Ga Detector Array1/16 Ch. Hartinger / L. Barl Ge:Ga Detector Arrays.
CEA-Grenoble / DSM / DRFMC / SBT / Lionel DUBAND - Instrument Baseline Design Review - PACS and SPIRE Cooler - Feb. 27/ SPIRE & PACS SORPTION COOLERS.
Spectrometer Solenoid Fabrication Status and Schedule Steve Virostek Lawrence Berkeley National Lab MICE RAL October 20, 2008.
PACS IBDR 27/28 Feb 2002 PACS PI Summary1 Where we are and where to go… A. Poglitsch MPE.
PACS IIDR ESTEC 01/02 March 2001 System Engineering 1 PACS Instrument Intermediate Design Review (IIDR) Reinhard Katterloher System Engineering DDVP, Model.
PACS IHDR MPE 12/13 November 2003 System Engineering 1 PACS IHDR Model Philosophy, Budgets, Interfaces and IID-B Reinhard Katterloher.
PACS IQR13 Jan 2005 Warm Electronics Qualification Status1 Martin von Berg PACS IQR.
PACS IHDR MPE, 12/13 Nov 2003 Overall Schedule1 Otto H. Bauer MPE Garching.
PACS IIDR ESTEC 01/02 March 2001 Integration and Testing1 PACS Instrument Intermediate Design Review (IIDR) Reinhard Katterloher Integration and Testing.
1DSM/DAPNIA/SAp – J. MartignacPACS - IHDR - MPE – Nov. 12 – 13, 2003 PACS – IHDR PhFPU Design J. Martignac CEA/DSM/DAPNIA Service d’Astrophysique.
PACS IBDR MPE 27/28 Feb 2002 System Engineering 1 PACS IBDR Model Philosophy / Development Plan Reinhard Katterloher.
Update on Micro Channel Cooling Collaboration Meeting , G. Nüßle.
SC Project Review of NCSX, April 8-10, 2008 NCSX Cryogenics Systems WBS-62 Steve Raftopoulos NCSX Cryogenic Systems WBS(62) Manager.
PACS SVR22/23 June 2006 Warm Electronics1 Warm Electronics: Components/Subsystems Test Results B. Voss PACS SVR.
SRR and PDR Charter & Review Team Linda Pacini (GSFC) Review Chair.
3 He Fridge SPIRE WE Review Dec. 6-7, IFSI 1 3 He Sorption Fridge “Cooler” WE Preliminary Design Presented by: L. Rodriguez / CEA/SAp. Subsystem.
PACS IBDR MPE 27/28 Feb 2002 AIV 1 PACS IBDR Test Cryostat and OGSE Gerd Jakob MPE.
RICH2 support and cooling mechanics status update Massimo Benettoni July 30,
Upgrade PO M. Tyndel, MIWG Review plans p1 Nov 1 st, CERN Module integration Review – Decision process  Information will be gathered for each concept.
PACS IHDR12/13 Nov 2003 Warm Electronics1 Warm Electronics: Overview, Interfaces, Grounding and EMC Martin von Berg PACS IHDR.
BSMIan Pain, UK ATC SPIRE Instrument Intermediate Design Review April 23, RAL 1 Beam Steering Mirror Sub-System IIDR Overview Ian Pain UK ATC Colin.
Solar Orbiter EUS: Thermal Design Progress Bryan Shaughnessy, Rutherford Appleton Laboratory 1 Solar Orbiter EUV Spectrometer Thermal Design Progress Bryan.
PACS IQR Kick-off ESTEC, 13 Jan 2005 PA/QA Status1 O.H. Bauer MPE Garching PA/QA Status.
PACS IIDR ESTEC 01/02 March 2001 Budgets and Interfaces 1 PACS Instrument Intermediate Design Review (IIDR) Reinhard Katterloher Budgets and Interfaces.
PACS IHDR12/13 Nov 2003 Cryo Harness1 Cryo Harness, Test Cryo Harness Martin von Berg PACS IHDR.
ILC : Type IV Cryomodule Design Meeting Main cryogenic issues, L. Tavian, AT-ACR C ryostat issues, V.Parma, AT-CRI CERN, January 2006.
LARP Phase II Secondary Collimator RC1 Review SLAC 12/15/05 RC1 Construction and Test Plan LARP LHC PHASE II COLL REVIEW – RC1.
Aachen Status Report: CO2 Cooling for the CMS Tracker
Mechanics for front-end Electronics Of T2K-II TPCs – A Few Conceptual Ideas D. Calvet, Irfu, CEA Saclay, Gif sur Yvette Cedex, FRANCE.
FP420 Detector Cooling Thermal Considerations
Aachen Status Report: CO2 Cooling for the CMS Tracker
Nov. 19, 2009 prepared by H. Matsuhara, N. Takahashi, T. Nakagawa
SPICA / FPI Mechanical /Optical Issues
Presentation transcript:

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 1 MPE J. Schubert PACS IHDR

12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 2 Content Overview QM FPU, Status and Problem Areas Status PACS Mechanical I/F to S/C Status PACS Thermal I/F to S/C –Allowed Mechanical Loads to Ge:Ga Detector I/Fs –Design and Changes on Cooler L0 I/Fs –Allowed Mechanical Loads to Level 0 Cooler I/Fs –Temperatures of LO I/F to HERSCHEL S/C In Orbit On Ground (IMT, and EQM)

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 3 Overview PACS FPU FPU QM structural parts manufacturing and assembly completed –Housing compartments blackened with KT 70 –Top Optic mirrors integration and alignment started Thermal and Load/Structural Analysis finalized Mechanical, Thermal and Electrical I/Fs to the S/C and to Subunits frozen Warm and Cryo Vibration performed on STM structure with success Subunits delivered (Chopper) or within the end of the AIV phase Extremely tight schedule increases risk for all parties and possibly shifts problem to the FM

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 4 Overview (cont.) Open issues to be worked on Distribution board  qualification/testing of PCB board not finalised, delaminating problem observed, investigation ongoing Mirrors  Gold layer on 3 of 13 mirror batches did not pass the tape test, investigation ongoing Detector Array  Delta cold vibration tests to be performed on Detector Array Components PhFPU  Bolometer Kevlar suspension failed during cold vibration in STM FPU, cold delta vibration test in preparation PhFPU I/F to S/C  a) mechanical load from S/C cooling is critical, b) not enough clearance between back shells of S/C harness and PhFPU connector panel (TBC)

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 5 PACS Mechanical I/F to S/C PACS FPU ICD Drawing Issue 27 DRAFT distributed to ESA & Industry for comment, 04-July-03 Major design changes compared to issue 25 reworked+implemented –Level 0 S/C IF to Ge:Ga detectors, pin to flat I/F (compliant to IID-A) –Mechanical I/F to OB, pin diameter & position (compliant to IID-A) Further detailed information added –Cold/Warm configuration, Mounting & Handling Equipment and Non Flight Items etc., drawing split into ten separate drawings Final release after working in ASTRIUM comments (received 9-Oct-03) –PACS QM manufacturing finished, no further updates beyond Issue 27 foreseen –Further requests/changes beyond Issue 27 are only possible via formal CR to PACS Level 0 Sorption Cooler I/F not reflected in Issue 27 anymore (separate drawing needed by CEA) –Removing I/F-adapter (ECP#6) accepted by ESA and Industry

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 6 PACS Thermal I/Fs to SC GeGa Level 0 I/F (2x) Pin I/F changed to rectangular I/F soldered to pin; Conduct resistance at I/F can be tuned to minimize heating of blue detector Ge:Ga Level 0 GeGa Level 0 PhFPU Level 0 Level 1 Level 1 I/F (3x) Thread distance changed from 33 mm to 37 mm PhFPU/Cooler Level 0 I/F (2x)

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 7 Mechanical Loads to Level 0 Ge:Ga Detectors I/F Amendment to CR, H-P-PACS-ME- 008 issued 29.Oct03, includes also updated mechanical load values for the Ge:Ga Detectors L0 I/F to be in line with the changed mechanical I/F (pin to flat mounting I/F): –Torque, longitudinal bending moment to central copper cold pin. < 1.8 Nm –Torque, rotation moment to the central copper cold pin < 0.2 Nm –Axial force to the central copper cold pin < 500 N –Lateral force to the central copper cold pin < 100 N This IF loads regarded as uncritical For the fixation of the straps a mounting tool is foreseen

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 8 ECP PACS-ME-ECP 06, issued 27-July-03 agreed 16-Oct-03 –Reason for ECP: I/F temperature requirements of 1.85K at the end of the cooler recycling phase, acc. H-P-PACS-CR-0009, cannot be met -> 46h cooler hold time in question –Proposal (agreed): Remove I/F adapter; remaining contribution from PACS side to the overall thermal conductance (He-tank to Evaporator I/F) is now the contact resistance at the I/F to the cooler -> ~ 30% gained in thermal conductivity to the cooler I/F Engineering Change at PACS Thermal Cooler L0 I/F New DesignOld Design

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 9 Mechanical Design at L0 Cooler I/F after ECP Changed Mechanical I/F Design at PACS Cooler S/C strap routing/ integration location of S/C temperature sensors Necessary design change on PhFPU side rerouting PhFPU 2K strap shifting 2K feed through I/F baffle to reduce radiation environment performed already CQM Parts manufactured ! BUT: Mechanical loads from S/C ? S/C Cooling Strap to Pump (cut in drawing, shown partly only) PhFPU Cooling Strap to Bolometer S/C Cooling Strap Evaporator PhFPU Baffles PhFPU Feed Through S/C Temp. Sensors

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 10 Mechanical Loads to Level 0 Cooler I/F Change Request to PACS IID-B: H-P-PACS-ME- 008, Issued 26-Nov-2001, I/F Loads identified as Single point failure –The mechanical loads arising from the level 0 cooling straps to the fixation points of the cooling straps at the PACS FPU must be limited. Impact of no- change: Damage of the mechanically sensitive thermal I/Fs during mounting and/or during launch can happen. –Static load: 50 N –Dynamic load: 50 grams (20.8G rms assumed) CR was not processed further. Reason: missing final design of S/C level 0 cooling strap (under Industry responsibility) Current Design for the S/C cooling strap: –½ mass of cooling strap, pulling at the Level 0 I/F was 312 grams –New ½ mass acc. AIR LIQUIDE study could be grams

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 11 Mechanical Loads to Level 0 Cooler I/F (cont.) First results from FEE on cooler switch I/F done by CEA-SBT (01-Oct-03): –dynamical response of the switch, (e.g. first eigenfrequency) depends on the additional mass fixed at the interface level: -50 grams, the first eigenfrequency is 194 Hz -100grams Hz -300 grams Hz –maximum admissible mass at I/F could be potentially increased to 100 grams. TN on FEE calculation in preparation. S/C cooling strap design needs to be balanced between conductance requirements (reduce cross section, change material TBC) and mechanical load requirements MPE proposes to perform a coupled FEE analysis, to take into account the dynamic behaviour of the S/C cooling strap and to perform a cold vibration test in "full" configuration (PhFPU/cooler/cooler switch + strap) representative to the flight configuration Amendment to CR, H-P-PACS-ME- 008 issued 29.Oct03, but 100 grams can not be guaranteed as long as no detailed FEE analysis is performed.

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 12 HERSCHEL L0 I/F Temperature to the Cooler Evaporator Agreement reached on HERSCHEL Open Tank Solution, HERSCHEL L0 I/F meeting

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 13 Estimation of PACS Level 0 I/F Temperatures in Orbit HERSCHEL Tank Temperature:1.7K Material Pods: Al 1050 Open Pods:Open Tank Solution for the Evaporator I/F Conductance data taken from AIR LIQUIDE analysis HP-2-AIRL-AN-0004 I/FTotal Conductance [W/K] Max Heat Flux [mW] Calculated Temperature at IF [K] Max. Temperature allowed [K] OK Blue Detector0.039 *) Yes Red Detector Yes Cooler Pump Condensation End of Cond. Low Temp  10 ~ 500  N/A Yes Cooler Evaporator Condensation End of Cond. Low Temp  15  Yes *) Can be tuned at the I/F

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 14 Difference between Ground and Orbit Tilt of Cryostat –The temperature of the cooler evaporator I/F at the end of the recycling phase defines the condensation efficiency of the 3 He (hold time of the cooler) –The difference between on ground and in orbit is the convective effect. This only affects the recycling phase. Once the cooler is cold, orientation does not matter. -In orbit: We can assume the in-orbit case corresponds to a 60-90° tilting for the cryostat on ground. At the end of the recycling phase, the power flowing through the evaporator strap is 18 mW (measured 14 mW in the latest test). -On ground: If the cryostat can only be tilted 20°, the power flowing through the evaporator strap at the end of the recycling phase can extrapolate to be about mW !!!

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 15 Difference between Ground and Orbit (cont.) Herschel Tank Temperature Orbit: 1.7K Ground (IMT): 1.7K to 1.8K –Temperature shift at cooler I/F up to 100mK due to warm up after days L1 Temperature (~PACS FPU temperature) Orbit: 3K to 3.5K Ground(IMT): 6.3K to 7.3K –Thermal load from L1 to L0 through switch base increased (0.45mW -> ~2mW) –Impact to hold time (needs further assessment using measured values) –Impact on the Net heat lift at 300mK (needs further assessment using measured values) Thermal Radiation Environment Orbit: 9K –10K Ground (IMT): 8K – 10K –5- 6 K, no impact expected, for 10 K we don't know (hard to calculate) –cooler is pretty much covered by protective baffles and caps (best we could do) It is assumed the heat sink to the cryostat drops back down to 1.8 K once the condensation phase is completed

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 16 Estimation of PACS Level 0 I/F Temperatures IMT Tank Temperature:1.75K Thermal radiation environment:8K-10K, not taken into account Level 1 temperature unknown: 6.3K to 7.3K, not taken into account Conductance data taken from AIR LIQUITE analysis HP-2-AIRL-AN-0004, Al 1050 I/FTotal Conductance [W/K] Max Heat Flux [mW] Calculated Temperature at IF [K] Max. Temperature allowed [K] OK Blue Detector0.27 *) Yes Red Detector (No) Cooler Pump Condensation End of Cond. Low Temp  10  500  N/A No Yes Cooler Evaporator Condensation End of Cond. Low Temp deg tilt 80 (TBC)  35 (TBC)  No Yes *) Can be tuned at the I/F

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 17 Estimation of PACS Level 0 I/F Temperatures EQM Tank Temperature:unknown, used also 1.65K Thermal radiation environment:unknown, should be  5K Level 1 temperature unknown: unknown, should be around 4K to 5K Conductance data taken from AIR LIQUITE analysis HP-2-AIRL-AN-0004 I/FTotal Conductance [W/K] Max Heat Flux [mW] Calculated Temperature at IF [K] Max. Temperature allowed [K] OK Blue Detector0.062 *) Yes Red Detector Yes Cooler Pump Condensation End of Cond. Low Temp  10  1000  N/A No Yes Cooler Evaporator Condensation End of Cond. Low Temp deg tilt 80 (TBC)  35 (TBC)  Yes No Yes *) Can be tuned at the I/F

PACS IHDR 12/13 Nov 2003 Overview and Mechanical/Thermal IFs to FPU 18 Summery on PACS Level 0 I/F Temperatures In Orbit –With the “Open Tank Solution” and with Al 1050 for the HERSCHEL tank pods, PACS Temperature requirements on the L0 I/Fs can by fulfilled. On Ground –It is not clear whether the PACS cooler can be recycled and/or run at 0.3mK with sufficient cooling power during IMT test. –With a cryostat tilt of more than 20 degree, the situation can be improved by a factor 2.3 (for recycling only) –IMT/EQM testing and testing conditions needs further assessments to be performed by all parties. –Lionel Duband (CEA) needs to perform further calculations (tests?) using new validated boundary temperatures for the Ground test.