Master Streams. Master Stream Training Available...  Awareness and Operations Training  Portable Monitors  Offensive Strategies  Defensive Strategies.

Slides:



Advertisements
Similar presentations
How To Pull A Pre-Connect
Advertisements

Fire Apparatus Pump Theory

Strategy and Tactics with Limited Staffing
Motion - a change in position of an object, caused by an object Force – a push or a pull, caused by another object Force Can – Start Motion Stop Motion.
TFT Blitzfire.
Blitzfire Deck Gun Ground Monitor
Adapted From Cody Fire School Presentations Amsterdam Fire Regular Fire Training February 16, 2009.
Fire Hose and Appliances
Intermediate SFFMA Objectives: – Hrs received.
Nozzle Pressure. Designed Nozzle Pressures  Smooth Bore Nozzle - Handline 50 PSI  Smooth Bore Nozzle - Master Stream 80 PSI  Combination Nozzle - (all.

Fire Streams Geronimo Vol. Fire Dept.. Extinguishing Properties of Water G Water extinguishes fires by G Cooling G Remove heat from the fire G Smothering.
Hydraulic Calculations
Augmenting Fire Standpipe Systems
For The Driver Operator
Engine Company Operations
1 Engine Company Riding Positions Handline Stretching.
Nozzles and Fire Streams 1. Introduction Fires usually extinguished by water Water delivered using nozzles and fire streams Nozzle selection important.
Driver Recert 2013 Topics Review of Water Supply SOG’s MAWW Main St. Tank OOS BlitzFire Deployment with Water Thief Tower Operations Foam System Review.
Riding Assignments Presentation February 28, 2011.
Objective General knowledge in proper operation of Ladder 2807 Ability to recognize safety hazards during ladder operations Demonstrate rescuing a conscious.
AO-AD Unit 41 NYS Department of State Office of Fire Prevention & Control APPARATUS OPERATOR AERIAL DEVICE Outreach Training Course 79.
Unit 5 Use of Water. Unit 5 Objectives b Explain different types of water use operations b Demonstrate laying a wet line with both simple and progressive.
Pumping Apparatus Driver/Operator
CHAPTER 14 LADDERS Copyright© Delmar is a division of Thomson Learning.
Categories of Aerial Ladders Aerial Ladders Aerial Platforms Telescoping Aerial Platform Tele-Squirt Articulating Aerial Platform Quint.
CHAPTER 14 Copyright © 2007 Thomson Delmar Learning 14.1 Ladders.
INTRODUCE SELF AND EXPLAIN GOING TO COVER BASIC
Fire Streams SFFMA Training Objectives: –
Fire Suppression Techniques IFSTA Chapter 14
Nozzles, Fire Streams, and Foam
DALE CITY VOLUNTEER FIRE DEPARTMENT Cluster Homes Firefighting Strategies & Tactical Recommendations.
C L A S #4 Driver Operator Refresher Training.
Pumping Apparatus Driver/Operator
Fire vs. Water Flow. What’s the best size for an “attack line?”  Maximum flow  Maximum mobility  Speed-How fast and how much  Ease of deployment and.
PREINCIDNET PREPARATION. OBJECTIVES Properly calculate required fire flow for structures using the National Fire Academy Fire Flow Formula. FIRE FLOW.
Instructor Lee Lautzenheiser
C L A S #5 Driver Operator Refresher Training.
Pumping Apparatus Driver/Operator
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
TFT Blitzfire.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
UTILITY SHUT DOWN PROCEDURES. Introduction Review with all crew members proper shut down procedures for Natural Gas and Electrical in emergency situations.
Mahoney, Hannig, Fire Department Hydraulics, 2nd Ed. ©2009 by Pearson Education, Inc., Upper Saddle River, NJ Fire Department Hydraulics Chapter 8 Required.
Apparatus Parking on Freeways Capt. Dean L. Sylvies SBFD Jan
MODULE 6: PRIVATE DWELLING SIMULATIONS. OBJECTIVES Module 6 Overview Identify the unique construction factors of single-family dwellings. Recognize the.
Part C  Accordion load  Lay the first length of hose in the bed on edge against the partition with the coupling at the rear of the bed  At the front.
Fixed & Selectable Flow Nozzles. Combination (Fog) Nozzle Development.
21 Fire Suppression Skill Drills. 2 Objectives Apply water using the direct, indirect or combination attack. Use a large handline using the one- or two-
Aerial Apparatus Operator Positioning Aerial Apparatus.
FIRE CONTROL State of Georgia BASIC FIRE FIGHTER TRAINING COURSE.
Aerial Apparatus Operator
Achieving Maximum Flows The Water Triangle.... The FIRE Tetrahedron.
Attack lines and pumping. What lines to pull?  Engineers should be able to understand what hose lines are for what purpose, what GPM they operate at,
TACTICS & STRATEGY II Fire Suppression.
Fire Department Cold Weather Ops Disclaimer: The content in this slide show has not been reviewed by the Department of Labor and Industries for accuracy.
Apparatus Testing Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
Photo by University of Houston Digital Library - Creative Commons Attribution-ShareAlike License with.
Water Shuttle Operations
IFSTA Chapter 16 Fire Streams
Relay Pumping Operations Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
Fire Hose Nozzles & Flow Rates
Firefighting Strategies & Tactical Recommendations
Dual Pumping Definition: An operation where a strong hydrant is used to supply two Engines by connecting the Engines intake-to-intake. The second Engine.
Master Stream Operations
Firefighting Strategies & Tactical Recommendations
Fire Safety & Fire Extinguisher Use
Steps to Interior Attack
Job Performance Requirement 10-32
Presentation transcript:

Master Streams

Master Stream Training Available...  Awareness and Operations Training  Portable Monitors  Offensive Strategies  Defensive Strategies  Current Applications  Attack Strategies  In-Depth Education  Training Aspects  Awareness and Operations Training  Portable Monitors  Offensive Strategies  Defensive Strategies  Current Applications  Attack Strategies  In-Depth Education  Training Aspects

Deck Guns, Portable Monitors & Bomb Lines  High flow for large fires  Can be put into service quickly  For Offensive or Defensive Attacks  Operated from Apparatus  Operated on Ground with Portable Base  High flow for large fires  Can be put into service quickly  For Offensive or Defensive Attacks  Operated from Apparatus  Operated on Ground with Portable Base

Why rethink our attack strategy?  Need for higher flows - Both interior and exterior  Higher fire loading in the structures  More numerous hazardous materials  Modern engines with higher flows  Need for higher flows - Both interior and exterior  Higher fire loading in the structures  More numerous hazardous materials  Modern engines with higher flows

Why rethink our attack strategy?  Changes in manning  How do we improve our flow with less people?  Larger diameter hose for moving water greater distances with less friction loss  Development of small lightweight portable monitors to handle the larger flows  Changes in manning  How do we improve our flow with less people?  Larger diameter hose for moving water greater distances with less friction loss  Development of small lightweight portable monitors to handle the larger flows

Conflicting goals? How are we going to INCREASE FLOWS and EFFECTIVENESS with LESS PERSONNEL? How are we going to INCREASE FLOWS and EFFECTIVENESS with LESS PERSONNEL?

Tactical Choices... What will be your first line pulled?  1 3/4” Preconnect  2 1/2” Preconnect  Preconnected Bomb Line with single 3” Line (2nd line optional) What will be your first line pulled?  1 3/4” Preconnect  2 1/2” Preconnect  Preconnected Bomb Line with single 3” Line (2nd line optional)

Lots of Fire... Minimum Personnel...  1 3/4” - 2 firefighters flow 160 GPM – (80 GPM each)  2 1/2” - 3 firefighters flow GPM – ( GPM each)  Bombline -3 firefighters flow GPM – ( GPM each)  1 3/4” - 2 firefighters flow 160 GPM – (80 GPM each)  2 1/2” - 3 firefighters flow GPM – ( GPM each)  Bombline -3 firefighters flow GPM – ( GPM each)

Options for attack?  1 - 4” Bombline 3 Firefighters  3 - 3” Attack Lines9 Firefighters  /4” Handlines 10+ Firefighters  1 - 4” Bombline 3 Firefighters  3 - 3” Attack Lines9 Firefighters  /4” Handlines 10+ Firefighters For 1000 GPM delivery: equalsequals equalsequals

Monitor Reaction Force...  High flows mean high reaction forces  Portable monitors must be secured to prevent sliding & lifting  Do not exceed manufacturer’s recommended operating flow & pressure  High flows mean high reaction forces  Portable monitors must be secured to prevent sliding & lifting  Do not exceed manufacturer’s recommended operating flow & pressure

Reaction Forces 502 (1 3 / 8 ”SB) 80 psi 227 lb/f 502 (1 3 / 8 ”SB) 80 psi 227 lb/f psi253 lb/f psi253 lb/f psi379 lb/f psi379 lb/f psi505 lb/f psi631 lb/f 502 (1 3 / 8 ”SB) 80 psi 227 lb/f 502 (1 3 / 8 ”SB) 80 psi 227 lb/f psi253 lb/f psi253 lb/f psi379 lb/f psi379 lb/f psi505 lb/f psi631 lb/f Nozzle Pressure Nozzle Reaction Flow(GPM)Flow(GPM)

Comparative Thrust Power (140 H.P.) Equal to a portable monitor flowing 1000 GPM!

Weight has little to do with it Not securing your portable monitor is just asking for trouble! Not securing your portable monitor is just asking for trouble!

Possible Securing Points for Monitors...  Parking Meters  Mailboxes  Trees  Parked Cars  Traffic Signs  Telephone Poles  Front Looped Hoselines  Non-removable Street Drains  Parking Meters  Mailboxes  Trees  Parked Cars  Traffic Signs  Telephone Poles  Front Looped Hoselines  Non-removable Street Drains

Additional Means for Safe Operation...  Use a life safety rope to extend the length of the chains or tie off strap  Interior work; use a long pry bar in doorway  Use the door jam itself  Span two immovable objects with life safety rope, keeping the angle as straight as possible  Use a life safety rope to extend the length of the chains or tie off strap  Interior work; use a long pry bar in doorway  Use the door jam itself  Span two immovable objects with life safety rope, keeping the angle as straight as possible

Elevation Safety Stop Pin...  It is a SAFETY STOP !  NEVER pull (override) in portable mode  Reaction forces will remain within footprint of portable monitor base, unless pulled  Should only be pulled when monitor is mounted on deck pipe on apparatus  Make sure stop pin is engaged when changing from deck mode to portable mode  Always use tie down method to secure monitor  It is a SAFETY STOP !  NEVER pull (override) in portable mode  Reaction forces will remain within footprint of portable monitor base, unless pulled  Should only be pulled when monitor is mounted on deck pipe on apparatus  Make sure stop pin is engaged when changing from deck mode to portable mode  Always use tie down method to secure monitor