ViewConn ® Pro VC-8200 1.Introducing ViewConn 2.Using ViewConn Pro 3.Optional Integrated Optical Power Meter 4. Specifications.

Slides:



Advertisements
Similar presentations
Each laptop is numbered Each slot in the laptop cabinet is numbered. Be sure to pick up the laptop that has been assigned to you! Getting the Laptops.
Advertisements

An Example of a Portable Computing Device. A PDA as an Example of a Portable Computing Device Recharger and connection to computer for replication Recharger.
Module 3 Configuring Hardware on a Computer Running Windows XP Professional.
Build Your Own Future RC2 Serviceability. Build Your Own Future Safety and Ground Rules Before servicing, always remove A/C power from the unit and disconnect.
Cable Probe. Safety First System can conduct electricity Do not use in flammable atmosphere Use proper personal protective equipment.
Zebra® 105SL™ * Removing and Installing Printhead
CI-1100-A2 1.Introducing the CI-1100-A2 2.Using the CI-1100-A2 3.Accessories.
NORTH POWERED AIR-PURIFYING RESPITATOR (PAPR) INSTRUCTIONS FOR USE Preventive Medicine Industrial Hygiene Service.
The EZ-SAT.
FloormapVS2i.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
ViewConn ® Plus VC-6200-PL 1.Introducing ViewConn 2.Using ViewConn 3.Options 1.Integrated Power Meter 2.Pass / Fail Software 3.Carrying Cases 4.Accessories.
Department of Environmental Conservation 1 DATAMAX PRINTER SETUP MODULE 1.
PRESS C7000/C7000P/C6000 Color Density Control Color Balance
CAN HELP iPC1550KP Keypad and Reprogramming Overview.
All rights reserved. Copyright © 2008 Argox Information Co., Ltd ISO 9001:2000 F1 Commercial & Light Industry Printer.
BBP11 Training BBP11-34L.
LogTag Training January 2015
CLINITEK Status® Plus UACR Operator Training Program
Optical Manufacturing Solutions 1 Probe Assembly.
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
ViewConn® Plus Introducing ViewConn Using ViewConn Options
Digital StarLab Set-Up, Operation, Maintenance, and Teacher Manual for the Digital StarLab are in the links below or on the training tab in the BlackBoard.
1 USDOC41 Rev 0 1/04 Training and Education Program ©2004 HemoCue, Inc. HemoCue ® Training and Education Program The HemoCue Hb System.
StatSensor® Creatinine Operator Training Program
Copyright 2008 Kenneth M. Chipps Ph.D. How to Terminate a Corning Unicam Connector Last Update
Basic fill color R 100 G 160 B 200 Accent 1 ”Logo Blue” R 0 G 39 B 118 Yellow (highlight) R 252 G 217 B 0 Accent 2 R 118 G 118 B 118 OP300 Technical training.
SGI Confidential Copan 400 Installation. SGI Confidential Installation Overview The approximate minimum time to complete this procedure is.
1 Zebra 170 XiIII Plus Removing and Installing Printhead Calibrating Head Resistance Print Quality Adjustments.
User Guide and Trouble-shooting Information. A classroom set of 20 cameras are available for teacher and student use. Capable of taking video, but recommend.
Windows XP Basics OVERVIEW Next.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
AquaGlo Water Detector Kit For Detecting Water in Jet Fuel
Scanning Tunneling Microscope How to use the STM Developed by Malory M. Peterson, Summer 2006 Nanotechnology Grant National Science Foundation #
EPOCH 1000 File Management Data Logging and Reporting
1 Training Manual: KI7400 & 7800 Series Sources Level 1, V2.0 August 2008.
© DIAMOND SA / / 1 CLEANING A focal point in fiber optics.
Chapter 3 Computer Assembly. 3. Introduction Assembling computers is a large part of a technician's job. This Chapter will teach you how to work in a.
© DIAMOND SA / / 1 Quality, Safety and reliability “one-hand” operation VIM DIAMOND VIDEO INSPECTION MICROSCOPE.
Basic Camera & Tripod Safety & Setup. Things to Consider: Camera’s are costly to repair (almost half of purchase price) Camera’s are costly to repair.
Page 1 © 2008 IDEAL INDUSTRIES IDEAL Micro OTDR Oktober 2008 Konstantin Hüdepohl.
The Accentuator A Wireless Annotator on Steroids Projection Perfection A Wireless Remote That Does it All Designed for Professionals.
CH 6 Configuring Server Hardware and power options.
The Mavica for the Maverick: A How-to Guide Operating instructions for the Sony Mavica CD350 Digital Camera An Easy-to-Follow Guide to Everything You Need.
In addition to Word, Excel, PowerPoint, and Access, Microsoft Office® 2013 includes additional applications, including Outlook, OneNote, and Office Web.
CLINITEK Status® Plus UACR Operator Training Program
Using the PDA Links to each of the topics Go to next slide Intro to “Getting Started Changing iPAQ Settings -Setting the Time/Date -Changing Keyboard.
Removing and Replacing the Battery Cover 1. Ensure the phone is turned off. 2. Press the Battery cover locker; lift the battery cover up and away from.
Digital Camera Basics Misty Freeman Georgia CTAE Resource Network 2010.
Photo Story 3 Importing Pictures. When you create a new Photo Story, the first thing that you will do is import pictures. You can import pictures from.
Set Up for Live Streaming Video This presentation will walk you through the set up and delivery for streaming video of a live event over the internet.
Microsoft Access 2010 Chapter 10 Administering a Database System.
Chapter 4 Working with Frames. Align and distribute objects on a page Stack and layer objects Work with graphics frames Work with text frames Chapter.
IOPtiMate™ OT-135P2 Technical Training – Part I System Description, Installation & Operation IOP (07)
Lightel Technologies, Inc.. Background Operation started Jan Based in Seattle, WA Manufacturing in US and China Business: Photonics equipment &
Digital Inspector (DI-1000) 1.Introducing the DI Using the DI Accessories.
FOCIS Flex Introduction to Operation June FOCIS Flex Intro to Operation Outline Controls, Display and Interfaces Connector Adapter Tips Operation.
Quick Start Guide ST30/ST32 Series mobile computer.
How to SWIVl: Using a Gen 2 SWIVL RObot
K TO 12 CHS MODULE FOR GRADE 9, PP
Yeti 400 Reprogram SOP 5/1/2017, Yeti firmware rev. 2.0.
Classroom Digital Camera
Receiving your new Microsoft Surface Pro 4
Chapter 31 Battery Systems.
Meeting In A Box Set Up Guide
About AirPrint AirPrint is an Apple technology that helps you create full-quality printed output without the need to download or install drivers.
1/17/2019.
VEXnet User's Guide.
1.11: Robot Controller.
Chapter 11: Printers IT Essentials v6.0 Chapter 11: Printers
Presentation transcript:

ViewConn ® Pro VC Introducing ViewConn 2.Using ViewConn Pro 3.Optional Integrated Optical Power Meter 4. Specifications

Safety Fiber optic lasers use light wavelengths not visible to the human eye. All Lightel microscopes are eye-safe video microscopes. Nevertheless, all standard safety precautions should be followed.

Inspect at Every Step  Manufacturing  QC and Receiving  System Assembly  Installation  System Testing  Network Testing  Maintenance  Troubleshooting

ViewConn was the first, and only, hand-held, all-in- one inspection and cleaning device. ViewConn’s integrated operation allows users to quickly and easily inspect, clean and reinspect, ensuring connectors are truly clean prior to mating. ViewConn’s large 3.5” display provides clear, sharp images. Introducing ViewConn

The ViewConn Plus dual microscope design, originated by Lightel, lets you easily inspect both male and female mated connector pairs without the time consuming need to change tips. Introducing ViewConn Plus Save Time

ViewConn Pro is an integrated system for fiberoptic connector inspection, evaluation, documentation and cleaning. This hand-held tool provides dual microscopes, touchscreen controls, Pass/Fail analysis and a cleaning cassette all in a single unit. Introducing ViewConn Pro The Comprehensive Solution

ViewConn Pro VC ViewConn adapter tip (INT) 2.ViewConn focus knob (INT) 3.Cursor touch pad 4.Left-click button 5.Right-click button 6.Wrist strap 7.5” color touchscreen 8.Stylus and stylus holder 9.Power button 10.Probe focus knob (EXT) 11.CC-1 cleaning cassette 12.USB port 13.Ruggedized cover 14.Optional integrated power meter

ViewConn Pro ViewConn Pro is designed to fit your work style. With a fold out stand, a wrist strap for support when holding it and neck strap attachments at either top or bottom, ViewConn Pro gives you the flexibility to use it whatever way the job requires. Its Li-Ion battery begins to recharge automatically whenever it is attached to an AC outlet.

When you turn ViewConn Pro on it will be set to inspect male connectors (patchcords and jumpers) ─ the INT setting. Use the large black ViewConn focus knob to focus the image. If you are unable to focus the image, verify that the tip is fully screwed in and the connector is properly seated in the tip. Inspecting Male Connectors Ensure that you have the proper tip in the tip receptacle at the top of ViewConn, then place the connector into the tip.

from the top down on a clean section of the CC-1 cassette. Do not scrub the connector back and forth and do not reuse a section of cleaner. Reinsert the connector in the tip to verify that it is now clean. If clean, make sure that the mated connector is also clean, before installing or reinstalling. If the connector was not clean, repeat the procedure and again recheck. Cleaning Male Connectors Once you have inspected the fiber, if you need to clean it, open the cover of the CC-1 cleaning cassette, and, using moderate pressure swipe the connector ferrule

If you decide you need to wet clean a connector, use a solvent dispenser like the optional Chemtronics Electro-Wash® pen dispenser to lightly wet a clean section of a CC-1 sheet. Less solvent is best. Always go from the wet portion to the clean dry portion. You always want to finish in a dry section of the sheet to be sure the solvent has been removed. Reinspect your connector as before to verify it is clean. Cleaning Male Connectors Wet Cleaning

When you have used all three slots on a CC-1 cleaning sheet, pull the sheet out to advance it to the next sheet. The cassette cover must be open to advance the sheet. If you wish to tear off a sheet, first close the cover. (A quick twisting motion works best to tear off the sheets.) CC-1 Cleaning Cassette To install the CC-1 cleaning cassette, place the tab at the top of the CC-1 in the slot at the top of the cassette holder. Then push the cassette in the space until it clicks into place. If you wish to remove the cassette, push up on the small blue plastic tab at the base of the cassette and lift the cassette out.

Changing ViewConn Tips All ViewConn tips are intended for use strictly with male connectors. Most ViewConn tips are universal tips, either PC or APC, for all connectors with the same ferrule size. All tips work for both single mode and multimode connectors. To install a ViewConn tip, align the tip’s key with the slot in the tip receptacle and seat it. Once seated, screw the tip in clockwise until tight. To remove a ViewConn tip, unscrew it counterclockwise and lift out. Key Slot

Inspecting Male APC Connectors A male APC connector is keyed. The key should be directly to the front of ViewConn to provide the best image. Or you can simply turn the connector until it has the best contrast. APC connectors are angled and need tips designed specifically to view them. (Note the angle on the tip stem.) Improperly Keyed APC ConnectorProperly Keyed APC Connector Key Alignment Mark

Inspecting Female Connectors To inspect female connectors (in bulkheads and patch panels) touch the INT portion of the touchscreen. It will change to read EXT. The image displayed will now be coming from the probe. The Field of View from the probe is wider allowing you to more easily locate the ferrule. With the correct tip installed for the connector type, place the tip of the probe into the adapter and use the focus knob on the probe to focus the image. If you are unable to focus, you may not have the probe tip fully inserted. Make sure it seats fully, and refocus. Remember, when using the probe, focus with the probe focus knob.

Inspecting Female Connectors When you have focused on the ferrule, you can freeze it to examine it, enlarge and automatically center it, and then analyze it. Or you can choose to just immediately analyze it.

Changing Probe Tips Probe tips are held in place with a lock nut. Holding the probe, turn the lock nut counter-clockwise to loosen it fully, and then remove the tip. All tips have a slot and fit into the key at the top of the probe. Slide the new tip in place and slip the lock nut over the tip. Tighten the nut snugly – if the tip is loose, it may not focus properly.

Probe Tips Most probe tips are for female connectors. (Universal male tips are available for the probe for special applications.) Female tips are specific to the type of connector being inspected. All tips work for both single mode and multimode connectors. Probe tips are available in a variety of styles for specialty applications including 60° angled tips extended tips and tips for ribbon connectors. (Visit the Series 2 Tips page on the Lightel website for a list of all current probe tips.)

Using ViewConn Pro ViewConn Pro is simple to use. The main screen provides access to all the ViewConn Pro features and all the controls you need to view, capture and analyze connectors. Or work from the Quick View screen with large simplified controls and a large graphic battery level indicator.

Using ViewConn Pro Capturing an image is as simple as a touch of the screen. With another touch you can shift to the probe and save images from it.

Using ViewConn Pro You can digitally zoom the connector for a closer look. Individualize your power saving settings or set up a Wi-Fi connection.

Using ViewConn Pro Check to ensure you are running the most recent Lightel software update for ViewConn Pro. You can easily go back and view any Analysis Report or image you have saved.

Analyzing Connectors You can analyze connectors with one touch. Simply touch the green Analyze button in Quick View. No calibration is necessary. Just select Single mode or Multimode. The data from each saved report is also automatically saved in a Summary Report. The ConnectorView Plus software can be set to automatically save the Analysis Report or you can choose to save only selected reports. Again it’s as simple as a touch of the screen.

Analyzing Connectors ConnectorView Plus software use IEC as the default standard for its analysis, but the acceptance criteria can be modified to allow for different corporate standards. Multiple standards can be stored and reused. A new Summary Report is automatically generated whenever criteria are changed. The Analysis Report shows that IEC was the standard used for this analysis.

ViewConn Pro Power Meter ViewConn Pro has an optional integrated power meter. This add-in module can be installed by Lightel or can be easily installed by the user. Two versions are available for standard or for higher power ranges. Universal 2.5mm and 1.25mm tips are included with each power meter. These tips work with both PC and APC connectors. Power readings can be taken and saved by themselves or linked to an Analysis Report. VC8-OPM installed in ViewConn Pro

Case ViewConn Pro comes in a reinforced soft case. With both a shoulder strap and handle, there is room enough for additional cleaning supplies and other tools. A tipbox with adjustable compartments capable of holding any ViewConn Pro tip is also included in the package.

ViewConn Pro Specifications ViewConn (Pro) Field of View~464μm x 346m Resolution0.5μm detectable Optical SensorCMOS Light SourceBlue LED LCD Display5” LCD color touchscreen Power Supply ◦ Li-Ion internally rechargeable battery or ◦ 12V DC adapter ◦ Adjustable automatic power saving ◦ Low battery indicator Battery Life≥3 hours (continuous) Electrical Ports ◦ DC adapter plug port ◦ 1 USB2.0 port Dimensions (including ruggedized cover)186mm (H) x 218mm (W) x 44mm (D) Weight (including battery and ruggedized cover) 1.4kg Storage8GB SSD Memory1GB ProcessorAtom Z530 Internet ConnectionWi-Fi Probe Field of View~660μm x 495μm Resolution0.5μm detectable Optical SensorCMOS Light SourceBlue LED Power SupplyUSB2.0 connection with ViewConn OutputUSB2.0 plug Dimensions35mm ø x 175mm (without cap) Software (pre-loaded) Operating SystemWindows XP® ConnectorView TM Plus ◦ Pass/Fail Analysis ◦ Full screen, touchscreen operation Analysis Time~4 seconds (average)