To learn more click on the selected method! Typical Cable Faults Unbalance Recommended Fault Location Method Disturbing voltage ▼ Murray ▼ Küpmüller ▼

Slides:



Advertisements
Similar presentations
Trouble Shooting with ELQ 30 CROSSTALK BRIDGED TAPS INTERRUPTION UNBALANCE Typical Cable Problems ELEKTR NIKA To learn more click on the selected topic!
Advertisements

ELEKTR NIKA Upstream Power Back Off (UPBO) The Problem is: Upstream bit rates on long loops are dramatically reduced. Very high-speed digital subscriber.
ELEKTR NIKA VDSL 2 Vectoring The Problem: The bit rate of VDSL2 lines is limited by the crosstalk noise. Typical a cable bundle comprises several tens.
Basic Jens Neigaard.

Automatic xDSL Test Sequences of ELQ 30A
ELEKTR NIKA To learn more click on the selected topic! Manual End to End Measuring Modes of ELQ 30A ► ► ► ► ► ► Loss Measurement with MTTS Group Delay.
Automatic Single Sided Test Sequence of ELQ 30A To learn more click on the selected topic! ELQ 30A provides single sided test sequences to estimate the.
FREQUENCY CONTROL MODES OF ET 91 To learn more click on note! END to END Loss Measurement Group Delay Distortion Measurement Frequency Tracking with Sweep.
Chapter : 7 : Mains Electricity
Lecture 6: Measurements of Inductance, Capacitance, Phase, and Frequency 1.
 “A multimeter is an instrument designed to measure electric current, voltage, and usually resistance, typically over several ranges of value.” They.
Trouble Shooting with EFL 10 Insulation Faults Flooded cable R b ≠ R aC b ≠ C a Typical Cable Problems Which one is the Proper Fault Location Method ?
IC Voltage Regulator.
INSULATION TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
Generating and Using Electricity
Arctic RS-485 / RS-422. RS- 485 Also known as RS-485 Half Duplex, RS wire same pair is used to transmit and receive data only one device can transmit.
12. Power Distribution Systems 1) Schematic diagram of part of a house wiring system 1.
Single Ended Measuring Modes of ELQ 30A To learn more click on the selected topic! ELEKTR NIKA Receiving Modes Impulse Noise Measurement Spectrum Analyzer.
Module 5, Unit A Vocabulary Review Game. 2 pt 3 pt 4 pt 5pt 1 pt 2 pt 3 pt 4 pt 5 pt 1 pt 2pt 3 pt 4pt 5 pt 1pt 2pt 3 pt 4 pt 5 pt 1 pt 2 pt 3 pt 4pt.
Kalvin Double Bridge.
Physics Electricity in the home. Direct current (d.c.) is an electric current that always flows in one direction. Made by batteries. Electronic circuits.
P1a internal assessment topic 9. Describe sources of direct current, including batteries and solar cells. Discuss the impact that the electric telephone.
Understanding Electricity
 “A multimeter is an instrument designed to measured electric current, voltage and usually resistance, typically over several ranges of value”.
3200 Electrical Test Equipment Calibrator The Total Solution to Electrical Test Equipment Calibration.
Mains Electricity Van de Graaff Generator Why are birds not electrocuted on power lines?
Automatic Voice Frequency Test Sequences of ELQ 30A To learn more click on the selected topic! The Automatic Master-Slave Measuring mode is intended for.
Which one is the Proper Fault Location Method ?
Single Ended Line Test with Upgraded ECFL 30
PLC Testing with ET 91 Level Test Set To learn more click on note! Pilot Level Measurement on RF Test Point Measurements in Special Tracking Mode Pilot.
Downstream Power Back Off (DPBO)
Cable for UPAMD Steve Sedio Foxconn 8/02/2011. Requirements: Power, 25 milliohms max – AWG selected by worst case resistance and operation at 50C Signal.
LOOP TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
LOCATION OF CABLE FAULTS
P2 - Physics Mains Electricity
PREPARED BY: PREPARED BY: PRATIK PATEL DEEP SANGANI G H PATEL COLLEGE OF ENGINEERING AND TECHNOLOGY.
Single Ended Measuring Modes of ELQ 30A+
Kalvin Double Bridge.
To learn more click on the selected system!
Manual End to End Measuring Modes of ELQ 30A+
Trouble Shooting with EFL 10
Automatic xDSL Test Sequences of ELQ 30A+
Schematic diagram of part of a house wiring system
Quick help for fault location and reliable detection of defects
Trouble Shooting with ELQ 35
1) Schematic diagram of part of a house wiring system
HVI HIPOT TEST SET Pft sERIES.
Direct-Current Bridge.
Single Ended Line Test with Upgraded ECFL 30
Telephone & Exchange Tester ETET 30
Telephone & Exchange Tester ETET 30
Trouble Shooting with ELQ 30
Automatic Voice Frequency Test Sequences of ELQ 30A+
Which one is the Proper Fault Location Method ?
Which one is the Proper Fault Location Method ?
Downstream Power Back Off (DPBO)
Dual-Wire Dual-Operator Programmable Continuous Monitor
Downstream Power Back Off (DPBO)
Single Ended Line Test with Upgraded ECFL 30
Automatic Single Sided Test Sequence of ELQ 30A+
Quick help for fault location and reliable detection of defects
Automatic Test Sequences in Master-Slave Mode
Upstream Power Back Off (UPBO)
Automatic Test Sequences in Master-Slave Mode
Trouble Shooting with ELQ 30A+
Upstream Power Back Off (UPBO)
Presentation transcript:

To learn more click on the selected method! Typical Cable Faults Unbalance Recommended Fault Location Method Disturbing voltage ▼ Murray ▼ Küpmüller ▼ 3-Point (a-b) ▼ 3-Point ▼ Repeated Küpfmüller ▼ Capacitive unbalance ▼ Resistance difference Low level Constant level Intermittent low level Intermittent Strongly changing fault resistance Flooded cable Insulation faults Sensitive Protected Sensitive Protected Which one is the Proper Fault Location Method ? ELEKTR NIKA

Disturbers The expected disturbing voltage depends on: A.) The function of neighboring pairs in the cable Intermittent disturbing voltages are expected if the neighboring pairs are used for POTS DC disturbing voltage is expected if the neighboring pairs are used only for ISDN No disturbing voltage is expected if the neighboring pairs are used only for data transfer B.) The distance to electrical railway High disturbing AC voltage is expected if the cable is very close to the track Low disturbing AC voltage is expected if the cable is fare enough from the track ELEKTR NIKA

Murray Method in Sensitive mode The result of Murray measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE insulation resistance ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results are: ■ Ia and Ib < 450 uA ■ Ф wire a=Ф wire b ■ FbE>1000 x FaE ■ FbE>10 MOhm If the disturbing voltages overload the input repeat the measurement in Protected mode Recommended when: ■ only one wire of a pair is faulty ■ the level of disturbing voltages are low The Murray method consists of 2 measurements: ■ Measurement of disturbing voltages ■ Bridge measurement with strap on the far end ELQ 30A automatically performs the 2 measurements with the help of the remote controlled switch ELC 30 ELEKTR NIKA

Murray Method in Protected mode The result of Murray measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE insulation resistance ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results are: ■ Ia and Ib < 7 mA ■ Ф wire a=Ф wire b ■ FbE>1000 x FaE ■ FbE>10 MOhm Recommended when: ■ only one wire of a pair is faulty ■ the disturbing voltages are not intermittent The Murray method consists of 2 measurements: ■ Measurement of disturbing voltages ■ Bridge measurement with strap on the far end ELQ 30A automatically performs the 2 measurements with the help of the remote controlled switch ELC 30 ELEKTR NIKA

Küpfmüller Method in Sensitive mode The result of Küpfmüller measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE and FbE insulation resistances ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results are: ■ Ia and Ib < 450 uA ■ Ф wire a=Ф wire b ■ 0,5>FaE / FbE>2 ■ FaE + FbE>100 x R loop If the disturbing voltages overload the input repeat the measurement in Protected mode Recommended when: ■ booth wires of a pair are faulty ■ the level of disturbing voltages are low The Küpfmüller method consists of 2 measurements: ■ First measurement with open far end ■ Second measurement with strap on the far end ELQ 30A calculates the Lx/L value from the results of the two measurements The far end can be automatically closed and open with the help of the remote controlled switch ELC 30 ELEKTR NIKA

Küpfmüller Method in Protected mode The result of Küpfmüller measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE and FbE insulation resistances ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results are: ■ Ia and Ib < 7 mA ■ Ф wire a=Ф wire b ■ 0,5>FaE / FbE>2 ■ FaE + FbE>100 x R loop Recommended when: ■ booth wires of a pair are faulty ■ the disturbing voltages are not intermittent The Küpfmüller method consists of 2 measurements: ■ First measurement with open far end ■ Second measurement with closed loop ELQ 30A calculates the Lx/L value from the results of the two measurements The far end can be automatically closed and open with the help of the remote controlled switch ELC 30 ELEKTR NIKA

Repeated Küpfmüller Method in Sensitive mode Recommended when: ■ The level disturbing voltages are low ■ The fault resistances are strongly changing That method is a sequence of repeated Küpfmüller measurements consisting of 15 part measurements alternating : ■ 8 measurements with open loop (L) ■ 7 measurements with closed loop (K) The far end is automatically closed/open with the help of the remote controlled switch ELC 30 When the sequence is completed ELQ 30A selects the acceptable Lx/L results and calculates the average of the accepted results. The unacceptable results are omitted and marked with asterisks. The Lx/L results are displayed in two columns and a histogram ELEKTR NIKA

Repeated Küpfmüller Method in Protected mode Recommended when: ■ The disturbing voltages are intermittent ■ The fault resistances are strongly changing That method is a sequence of repeated Küpfmüller measurements consisting of 15 part measurements alternating : ■ 8 measurements with open loop (L) ■ 7 measurements with closed loop (K) The far end is automatically closed/open with the help of the remote controlled switch ELC 30 When the sequence is completed ELQ 30A selects the acceptable Lx/L results and calculates the average of the accepted results. The unacceptable results are omitted and marked with asterisks. The Lx/L results are displayed in two columns and a histogram ELEKTR NIKA

3-Point (a-b) Method in Sensitive mode Recommended when: ■ the insulation between wires and ground is good ■ the insulation resistance between wires a and b is low ■ some healthy pairs are available ■ the level of disturbing voltages are low The result of 3 Point measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE insulation resistance ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results: ■ Ia and Ib < 450 uA ■ The insulation resistance of auxiliary wires must be thousand time as high than that of the faulty one. If the disturbing voltages overload the input repeat the measurement in Protected mode The 3-Point method consists of 3 measurements: ■ First measurement when the measuring voltage is connected to wire a ■ Second measurement when the measuring voltage is connected to the ground ■ Third measurement when the measuring voltage is connected to wire c ELQ 30A automatically performs the 3 measurements with the help of the remote controlled switch ELC 30 ELEKTR NIKA Healthy auxiliary wires Faulty pairFaE

3-Point (a-b) Method in Protected mode Recommended when: ■ the insulation between wires and ground is good ■ the insulation resistance between wires a and b is low ■ some healthy pairs are available ■ the disturbing voltages are not intermittent The result of 3 Point measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE insulation resistance ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results: ■ Ia and Ib < 7 mA ■ The insulation resistance of auxiliary wires must be thousand time as high than that of the faulty one. The 3-Point method consists of 3 measurements: ■ First measurement when the measuring voltage is connected to wire a ■ Second measurement when the measuring voltage is connected to the ground ■ Third measurement when the measuring voltage is connected to wire c ELQ 30A automatically performs the 3 measurements with the help of the remote controlled switch ELC 30 ELEKTR NIKA Healthy auxiliary wires Faulty pairFaE

The result of 3 Point measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE insulation resistance ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results: ■ Ia and Ib < 450 uA ■ The insulation resistance of auxiliary wires must be thousand time as high than that of the faulty one. If the disturbing voltages overload the input repeat the measurement in Protected mode Recommended when: ■ the gauge of wires in a pair are different ■ some healthy pairs are available ■ the level of disturbing voltages are low The 3-Point method consists of 3 measurements: ■ First measurement when the measuring voltage is connected to wire a ■ Second measurement when the measuring voltage is connected to the ground ■ Third measurement when the measuring voltage is connected to wire c ELQ 30A automatically performs the 3 measurements with the help of the remote controlled switch ELC 30 ELEKTR NIKA Healthy auxiliary wires Faulty wire FaE 3-Point Method in Sensitive mode

The result of 3 Point measurement is: Lx/L In addition ELQ 30A provides: ■ RL loop resistance ■ FaE insulation resistance ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results: ■ Ia and Ib < 7 mA ■ The insulation resistance of auxiliary wires must be thousand time as high than that of the faulty one. Recommended when: ■ the gauge of wires in a pair are different ■ some healthy pairs are available ■ the disturbing voltages are not intermittent The 3-Point method consists of 3 measurements: ■ First measurement when the measuring voltage is connected to wire a ■ Second measurement when the measuring voltage is connected to the ground ■ Third measurement when the measuring voltage is connected to wire c ELQ 30A automatically performs the 3 measurements with the help of the remote controlled switch ELC 30 ELEKTR NIKA Healthy auxiliary wires Faulty wire FaE 3-Point Method in Protected mode

ELQ 30A provides the following results: ■ Ra and Rb wire resistances ■ RL loop resistance ■ Δ R resistance difference ■ % The condition of accurate results is: Ia and Ib < 450 uA If the disturbing voltages overload the input repeat the measurement in Protected mode ELQ 30A automatically performs the measurements with the help of the remote controlled switch ELC 30 The resistance difference measurement is recommended if the balance of the tested pair is poor Resistance Difference Measurement in Sensitive mode ELEKTR NIKA

Resistance Difference Measurement in Protected mode ELQ 30A provides the following results: ■ Ra and Rb wire resistances ■ RL loop resistance ■ Δ R resistance difference ■ % The condition of accurate results is: Ia and Ib < 7 mA That condition is practically always fulfilled. ELQ 30A automatically performs the measurements with the help of the remote controlled switch ELC 30 The resistance difference measurement is recommended if the balance of the tested pair is poor ELEKTR NIKA

ELQ 30A provides the following results: ■ Lx/L ■ CaE and CbE wire capacitances ■ Δ C capacitance difference in nF ■ Δ % capacitance difference in % The condition of accurate results is: Ia and Ib < 450 uA If the disturbing voltages overload the input repeat the measurement in Protected mode The resistance difference measurement is recommended if the balance of the tested pair is poor Capacitance Unbalance Measurement in Sensitive mode ELEKTR NIKA

Capacitance Unbalance Measurement in Protected mode ELQ 30A provides the following results: ■ Lx/L ■ CaE and CbE wire capacitances ■ Δ C capacitance difference in nF ■ Δ % capacitance difference in % The condition of accurate results is: Ia and Ib < 7 mA That condition is practically always fulfilled. The resistance difference measurement is recommended if the balance of the tested pair is poor ELEKTR NIKA

THANK YOU FOR YOUR ATTENTION!