ANALYSIS OF TWO-WAY SLABS WITH BEAMS

Slides:



Advertisements
Similar presentations
Two-way Slabs.
Advertisements

Outline CH1.Introduction CH2.Preliminary Design CH3.3D Model.
Example (10.2): Redesign the stair shown in Example (10.1) if it is a cantilever type of a clear span of 1.6 m. Solution : Minimum stair thickness required.
2.2 STRUCTURAL ELEMENT BEAM
Chp12- Footings.
Design of Concrete Structure I
Reinforced Concrete Design-8
Lecture 9 - Flexure June 20, 2003 CVEN 444.
CEE Capstone II Structural Engineering
Lecture 33 - Design of Two-Way Floor Slab System
Overview Waffle Slab.
Eccentric Shear Welded Connections
Reinforced Concrete Flexural Members
Lecture 15- Bar Development
Lecture Goals Slab design reinforcement.
ONE-WAY SLAB. ONE-WAY SLAB Introduction A slab is structural element whose thickness is small compared to its own length and width. Slabs are usually.
Torsion in Girders A2 A3 M u = w u l n 2 /24 M u = w u l n 2 /10M u = w u l n 2 /11 B2 B3 The beams framing into girder A2-A3 transfer a moment of w u.
CM 197 Mechanics of Materials Chap 14: Stresses in Beams
Reinforced Concrete Design II
786 Design of Two way floor system for Flat slab
Slab Design.
Reinforced Concrete Design II
Weekly Course Distribution
FOUNDATION DESIGN.
Footings.
COLUMNS. COLUMNS Introduction According to ACI Code 2.1, a structural element with a ratio of height-to least lateral dimension exceeding three used.
Composite Beams and Columns
DESIGN FOR TORSION Reinforced Concrete Structures
SHEAR IN BEAMS. SHEAR IN BEAMS Introduction Loads applied to beams produce bending moments, shearing forces, as shown, and in some cases torques. Beams.
Umm Al-Qura University Department of Civil & Structural Engineering 1 Design of reinforced concrete II Design of one-way solid slabs Lecture (1)
Lecture 5 January 31,  Sudhir K. Jain, IIT Kanpur E-Course on Seismic Design of Tanks/ January 2006 Lecture 5/ Slide 2 In this Lecture Impulsive.
University of Palestine
Al-Najah National University Engineering Faculty Civil Engineering Department Graduation Project: Analysis & Design of Warehouses in Jaba’-Jenin.
Reinforced Concrete Design
Compression Component Design
DIRECT DESIGN METHOD “DDM”
Lecture 2 - Fundamentals. Lecture Goals Design Process Limit states Design Philosophy Loading.
1.
FOOTINGS. FOOTINGS Introduction Footings are structural elements that transmit column or wall loads to the underlying soil below the structure. Footings.
7. APPROXIMATE ANALYSIS OF INDETERMINATE STRUCTURES
Chapters Project title : Hirbawi Center A building lies in the east side of Tulkarm, this building consists of five stories of ( m 2 ) A building lies.
Umm Al-Qura University Department of Civil & Structural Engineering 1 Design of reinforced concrete II Design of Flat Slab Floors Lecture (3)
Fordham Place Bronx, NY Aric Heffelfinger Structural Option Spring 2006.
Practical Design of PT Buildings
PCI 6 th Edition Lateral Component Design. Presentation Outline Architectural Components –Earthquake Loading Shear Wall Systems –Distribution of lateral.
Prof. Shrikant M. Harle Asst prof. Dept of Civil Engg PRMCEAM
Built-up Compression Members
Dr Badorul Hisham Abu Bakar
Compression Members.
786 Design of Two Way floor system for Flat Plate Slab
Outline: Introduction: a ) General description of project b) Materials
Flat slab Structures VI.
Supervied by : Eng. Ibrahim Mohammad Prepared by : Atheer Daraghmeh
Slender Columns and Two-way Slabs
Pile Group
An-Najah National University
Chapter-2 Parts of Steel Bridges.
Lecture 39 - Design of Two-Way Floor Slab System
ANALYSIS AND DESIGN OF FLAT SLAB
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg
786 Design of Two Way Floor System for Slab with Beams
Analysis and Design of Multiple story building
Outline CH1.Introduction CH2.Preliminary Design CH3.3D Model.
Design Ribbed and Flat Slabs
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg.
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg
By :Dr. Aeid A. Abdulrazeg
Plain & Reinforced Concrete-1 CE3601
An Najah National University Submitted to : Dr.Munther Diab .
Chapter 13 Concrete Form Design.
Presentation transcript:

ANALYSIS OF TWO-WAY SLABS WITH BEAMS

ANALYSIS OF TWO-WAY SLABS WITH BEAMS In this lecture the moments are determined by the direct design method for an exterior panel of a two-way slab with beams. It is felt that if you can handle this problem, you can handle any other case that may arise in flat plates, flat slabs, or two-way slabs with beams using the direct design method. The requirements of the Code are so lengthy and complex that in Example 16.4, which follows, the steps and appropriate Code sections are spelled out in detail. The practicing designer should obtain a copy of the CRSI Design Handbook, because the tables therein will be of tremendous help in slab design.

ANALYSIS OF TWO-WAY SLABS WITH BEAMS Example 16.4 SOLUTION

ANALYSIS OF TWO-WAY SLABS WITH BEAMS

ANALYSIS OF TWO-WAY SLABS WITH BEAMS

ANALYSIS OF TWO-WAY SLABS WITH BEAMS

ANALYSIS OF TWO-WAY SLABS WITH BEAMS

ANALYSIS OF TWO-WAY SLABS WITH BEAMS

ANALYSIS OF TWO-WAY SLABS WITH BEAMS

ANALYSIS OF TWO-WAY SLABS WITH BEAMS

ANALYSIS OF TWO-WAY SLABS WITH BEAMS

ANALYSIS OF TWO-WAY SLABS WITH BEAMS

ANALYSIS OF TWO-WAY SLABS WITH BEAMS

ANALYSIS OF TWO-WAY SLABS WITH BEAMS

ANALYSIS OF TWO-WAY SLABS WITH BEAMS

ANALYSIS OF TWO-WAY SLABS WITH BEAMS

TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS

TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS On many occasions the maximum load that a two-way slab can support is dependent upon the strength of the joint between the column and the slab. Not only is the load transferred by shear from the slab to the column along an area around the column, but also there may be moments that have to be transferred as well. The moment situation is usually most critical at the exterior columns. If there are moments to be transferred, they will cause shear stresses of their own in the slabs, as will be described in this section. Furthermore, shear forces resulting from moment transfer must be considered in the design of the lateral column reinforcement (that is, ties and spirals), as stated in Section 11.11.1 of the Code. When columns are supporting slabs without beams (that is, flat plates or flat slabs), the load transfer situation between the slabs and columns is extremely critical. Perhaps if we don’t have the flexural reinforcing designed just right throughout the slab as to quantities and positions, we can get by with it; however, if we handle the shear strength situation incorrectly, the results may very well be disastrous.

TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS The serious nature of this problem is shown in Figure 16.20, where it can be seen that if there is no spandrel beam, all of the total exterior slab moment has to be transferred to the column. The transfer is made by both flexure and eccentric shear, the latter being located at a distance of about d/2 from the column face. Section 13.6.3.6 of the Code states that for moment transfer between the slab and edge column, the gravity load moment to be transferred shall be 0.3Mo (where Mo is the factored statical moment). When gravity loads, wind or earthquake loads, or other lateral forces cause a transfer of an unbalanced moment between a slab and a column, a part of the moment equal to γfMu shall be transferred by flexure, according to ACI Section 13.5.3.2. Based on both tests and experience, this transfer is to be considered to be made within an effective slab width between lines that are located 1.5 times the slab or drop panel thickness outside opposite faces of the column or capital. The value γf is to be taken as

TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS

TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS

TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS

TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS

TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS Example 16.5

TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS Example 16.5 SOLUTION

TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS Example 16.5 SOLUTION

TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS Example 16.5 SOLUTION

TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS Example 16.5 SOLUTION

TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS Example 16.5 SOLUTION

TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS Example 16.5 SOLUTION

Factored Moments in Columns and Walls TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS Factored Moments in Columns and Walls If there is an unbalanced loading of two adjoining spans, the result will be an additional moment at the connection of walls and columns to slabs. The Code (13.6.9.2) provides the approximate equation listed at the end of this paragraph to consider the effects of such situations. This particular equation was derived for two adjoining spans, one longer than the other. It was assumed that the longer span was loaded with dead load plus one-half live load and that only dead load was applied to the shorter span.

Factored Moments in Columns and Walls TRANSFER OF MOMENTS AND SHEARS BETWEEN SLABS AND COLUMNS Factored Moments in Columns and Walls If there is an unbalanced loading of two adjoining spans, the result will be an additional moment at the connection of walls and columns to slabs. The Code (13.6.9.2) provides the approximate equation listed at the end of this paragraph to consider the effects of such situations. This particular equation was derived for two adjoining spans, one longer than the other. It was assumed that the longer span was loaded with dead load plus one-half live load and that only dead load was applied to the shorter span.