2011 MF LRG New Orleans, LA Mobile Facilities Engineering FRC Southwest, North Island Design of MF Configurations Lloyd Bjurman, Lead Pete Vicencio, Electrical.

Slides:



Advertisements
Similar presentations
Water Source Heat Pump Systems
Advertisements

Unit 10 - Electricity.
Refrigeration Systems
USER MAINTENANCE.
Automobile Engine NO.4. NO.1 Mercedes-Benz E-class.
It can be as easy as patching a hose. TEAM UP! FOR COMPRESSED AIR SAVINGS.
“Enerpak” Units » Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners,
Shram Shakti Bhavan / Transport Bhavan Energy Services Performance Contracting Project Summary of annual savings from various EEMs Guaranteed savings -
Refrigerators.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
Chapter #19 Study Guide Answers.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
Engineering Controls and Laboratory Design Session 4 Laboratory Safety Training.
Engineered Products Make-Up Air for Heating and Cooling.
Unit 206: Domestic hot water systems
ROTHENBUHLER ENGINEERING
Engine Systems and Components
KLINGE’S NMR 262 Two Independent Systems Integrated into one Unit This Requires Special Features:  Total Redundancy of Refrigeration Components  Total.
Approved 15-minute eyewash/shower 29 CFR (c)
DHHB, 1ID MAINTENANCE Effects of Cold on Military Vehicles.
The Refrigeration System
2009 Fall MMSC Home Energy Makeover House #1 Chris Baryo Residence 4165 N 850 E Churubusco, Indiana.
LETS SAVE ENERGY! By Dawn J. Gorden. INTRODUCTION  What does energy saving mean to you?  Why is it important?  What are some categories?
2013 NATEF Task Area A-7 Heating, Ventilation, and A/C A. A/C System Diagnosis & Repair B. Refrigeration System Component D & R C. Heating, Ventilation.
Auraria Higher Education Center Case Study John Ismert & Frank Ellis Auraria Higher Education Center Facilities Management.
Unit 3- Schematic Symbols EET 110 Electronics Survey I.
FMTV COOLING SYSTEMS 4/23/2017.
Vacuum system.
Sawyer Environmental Changes Mechanical Engineering Department Capstone Amy R. Dan H. Colby C. Brittany P. Richard G. 1.
Home Electrical Systems. Behavior Objectives  Define the basics of Electrical Systems  Explain the basic principles of Electricity.  Describe the different.
2011 MF LRG San Diego, CA FLEET READINESS CENTER SOUTHWEST Mobile Facilities Configuration & Engineering Site MSgt William Kubik Jim Sorrells / Lloyd Bjurman.
Automotive Heating and Air Conditioning CHAPTER Automotive Heating and Air Conditioning, 7e James D. Halderman | Tom Birch SEVENTH EDITION Copyright ©
01/10/ PHOS Cooling status (1 Oct) Incident happened (ECV failure) 1 Oct at 5 Am cooling plant failure happened: ECV (electrical.
CM27 – 8 th July 2010 LH2 System Progress and Future Plans M Hills T Bradshaw M Courthold I Mullacrane P Warburton.
VCBs are well protected with interlocking switches for its switching device operation with busbar. Switching devices in VCBs have to be disabled or enable.
Direct Hot Water. What Cold Water System is Pictured? What hot Water System is Pictured?
Automotive Engines: Theory and Servicing, 7/e By James D. Halderman Copyright © 2011, 2009, 2005, 2001, 1997 Pearson Education, Inc., Upper Saddle River,
SUBMMITED BY : MOUTRISHNA GAYAN CLASS : VII ROLL. no : 9.
ID week 27 th of April 15 C3F8 cooling- Compressors & C3F8 status O. Crespo-Lopez EN/CV.
Kaeser Direct Drive ESD Rotary Screw Compressor
1 Product Presentation January Normal BinROXELL Bin Old feed Normal bin: ‘centerflow’ feed flows first in center  bridging ‘mass flow’ feed.
BASIC AUTOMATIC CONTROLS UNIT 16 ADVANCED AUTOMATIC CONTROLS
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Duct Sealing and Insulation TRAIN THE TRAINER WEATHERIZATION.
7 A/C System Components, Operation, and Service.
29 CFR Subpart G Related Terminal Operations and Equipment.
STORAGE AND MAINTENANCE OF LARGE FARM EQUIPMENT Prepared by : Von G. Peavy South Region Ag Mechanics.
Flammable Liquids Directorate of Training and Education
Approve Change Order No. 4 for the Caylor Wholesale Meter Modification Item 4B.
EBS-1 # COOLANT FLUID EXCHANGE QUICK REFERENCE ATTENTION: Using the Coolant Fluid Exchange requires the FILL and VAC Valves on the SERVICE.
Tractor Safety, Operation, and Maintenance
Automotive Engines Theory and Servicing
Automotive Heating And Air Conditioning
Chapter 37: Fluid Containment
Tractor Safety, Operation, and Maintenance
Design, Evaluation and Application of a Fuel Cell Vehicle
Electric Wiring & Illumination
Unit 37: Fluid containment Dr
TECHNICAL SPECIFICATION AND REQUIREMENTS
Product Presentation January 2010.
Tractor Safety, Operation, and Maintenance
Electrical Gas Plumbing Heating & Cooling
Unit 37: Fluid containment Dr
Hazardous Areas & Hazards of Electricity
JAMIE GREEN LOGISTICS / PUB MANGEMENT
New product launching Feature & operation introduction
Electric Potential.
Objectives Learn about Electricity Pricing Electric systems.
Objectives Review conductor and conduit selection
Parker domnick hunter. Safety of Electrical and
T-6B On-Board Oxygen Generation System (OBOGS)
Presentation transcript:

2011 MF LRG New Orleans, LA Mobile Facilities Engineering FRC Southwest, North Island Design of MF Configurations Lloyd Bjurman, Lead Pete Vicencio, Electrical Mark Beuster, Mechanical Steve Wilson, Electrical

2011 MF LRG New Orleans, LA LA-02 Sealed Lead-Acid Battery MF (Final) NB-04 New Ni-Cad Battery MF (Preliminary) TB-03/04 Tube Bender SOMF (Preliminary) Lithonia Light Ballast replacement Digital Thermostat connection to R-22 ECU Update on GDIT Ground-Neutral site visits Topics

2011 MF LRG New Orleans, LA 3 LA-02 – Final SLAB MF

2011 MF LRG New Orleans, LA 4 LA-02 – Final SLAB MF

2011 MF LRG New Orleans, LA 5 LA-02 – Final SLAB MF

2011 MF LRG New Orleans, LA 6 LA-02 – Final SLAB MF

2011 MF LRG New Orleans, LA NB03 – Current Ni-Cad MF Charger Booth Designed for “Vented” Ni-Cad Expensive Explosion-proof receptacles Expensive 3-phase explosion-proof fan Has Booths due to Hydrogen produced Booth with Explosion-proof Fan Explosion-proof outlets

2011 MF LRG New Orleans, LA NB03 – Current Ni-Cad MF Problems with current Battery MF Many at MALS are in poor condition Many Parts not in the stock system Complex Design Older Design (1985) Flow Valve Shower Water Tank Booth Door Switches

2011 MF LRG New Orleans, LA 9 NB04 – New Ni-Cad MF

2011 MF LRG New Orleans, LA Bradley Pressurized Drench Hose/Tank Portable Deluge Hose and Tank Can be replaced with NSN number item: Small Air Compressor included to pressurize (also has NSN) Follow Bradley Maintenance Schedule: Every 4 months change water (Saline) Once a month without saline added Used in Army and Air Force mobile battery facility Photo courtesy Safety Storage, Inc NB04 – New Ni-Cad MF

2011 MF LRG New Orleans, LA 11 NB04 – New Ni-Cad MF Durable Stainless Steel Thick, Clear Plexiglass Hinged Front Battery Charging Hood (Proposed) Spill Containment in base Exhaust duct to outside Clear Front. Easy to see charging. Easy to access hinged cover.

2011 MF LRG New Orleans, LA 12 NB03 – Current Ni-Cad MF NB04 – New Ni-Cad MF

2011 MF LRG New Orleans, LA 13 NB04 – New Ni-Cad MF

2011 MF LRG New Orleans, LA Simpler design--Easier for MALS to maintain Alarm made simpler No flow switch or booth switch Eyewash & Drench OSHA/ANSI compliant under 10-second access rule Many Major Parts have NSN-numbers Eyewash Portable Pressurized Drench Tank Air Compressor NB04 – Summary

2011 MF LRG New Orleans, LA New Tube Bender MFs CSE Tube Bender TB-03/04 Preliminary Design

2011 MF LRG New Orleans, LA 16 TB-03/04 Tube Bender MFs TB04

2011 MF LRG New Orleans, LA 17 TB-03/04 Tube Bender MFs

2011 MF LRG New Orleans, LA 18 TB-03/04 Tube Bender MFs TB04TB04

2011 MF LRG New Orleans, LA 19 TB-03/04 Tube Bender MFs

2011 MF LRG New Orleans, LA TB-03/04 Tube Bender MFs TB-03/04 replaces TB-01 at non-V22 MALS (without TB-02) MALS-11, 12, 13, 14, 31, 41, 49 TB-01 remains at MALS that have TB-02 MALS-16, 24, 26, 29, 36, 39

2011 MF LRG New Orleans, LA Old Lithonia Light Ballast Replacement

2011 MF LRG New Orleans, LA 22 Most T12 Magnetic Ballasts discontinued Mandated by Dept of Energy Directive Switching to Electronic to save Energy Old Lithonia Light

2011 MF LRG New Orleans, LA Old Lithonia Light

2011 MF LRG New Orleans, LA Newer Kenall Light

2011 MF LRG New Orleans, LA 25 Replacement Ballast is Electronic Use 2-Lamp Ballast only, NOT 4-Lamp Ballast Part # B232IUNVHP-B NSN: Old Lithonia Light

2011 MF LRG New Orleans, LA 2-Lamp Electronic Ballast T8 Lamp Schematic on Ballast Old Lithonia Light + +

2011 MF LRG New Orleans, LA 27 When installing Electronic Ballast Must also install T8 Lamps T8 Lamps same as those in Kenall Lights Old Lithonia Light

2011 MF LRG New Orleans, LA 28 Yes, T8 Lamps fit into Lithonia sockets Old Lithonia Light

2011 MF LRG New Orleans, LA Authorized Digital Thermostat RobertShaw Model 8425: 2 Stage Heat & 2 Stage Cool Specified in ECU manual NAVAIR , WP Digital Thermostat

2011 MF LRG New Orleans, LA 30 Digital Thermostat – R-22 ECU R-22 ECU Control Box 6-Conductor Cable

2011 MF LRG New Orleans, LA 31 Ground-Neutral Status General Dynamics Site Visits Completed: –MALS-11, 16, 13, & 24 Next Sites to visit for G-N Completion* –MALS-39, -- August –Twentynine Palms, -- August Next Sites to visit for G-N checks* –MALS-49, -- July –MALS-41, -- July –MALS-14, 26, 29, 31 – August * Pending Contract Approval

2011 MF LRG New Orleans, LA 32 Questions ?