Engenio 7900 HPC Storage System. 2 LSI Confidential LSI In HPC LSI (Engenio Storage Group) has a rich, successful history of deploying storage solutions.

Slides:



Advertisements
Similar presentations
IBM System Storage DS3000 Express Disk System
Advertisements

Archive Task Team (ATT) Disk Storage Stuart Doescher, USGS (Ken Gacke) WGISS-18 September 2004 Beijing, China.
Oracle Storage Networking Powered by QLogic Optimized for the Oracle Solaris Platform.
IBM Software Group ® Integrated Server and Virtual Storage Management an IT Optimization Infrastructure Solution from IBM Small and Medium Business Software.
PowerEdge T20 Customer Presentation. Product overview Customer benefits Use cases Summary PowerEdge T20 Overview 2 PowerEdge T20 mini tower server.
Module – 3 Data protection – raid
MUNIS Platform Migration Project WELCOME. Agenda Introductions Tyler Cloud Overview Munis New Features Questions.
© 2009 IBM Corporation Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change.
1 Magnetic Disks 1956: IBM (RAMAC) first disk drive 5 Mb – Mb/in $/year 9 Kb/sec 1980: SEAGATE first 5.25’’ disk drive 5 Mb – 1.96 Mb/in2 625.
Chapter 3 Presented by: Anupam Mittal.  Data protection: Concept of RAID and its Components Data Protection: RAID - 2.
An Overview of RAID Chris Erickson Graduate Student Department of Electrical and Computer Engineering Auburn University, Auburn, AL 36849
1© Copyright 2011 EMC Corporation. All rights reserved. EMC SQL Server Data Warehouse Fast Track Solutions Nov 30, 2011 Ling Wu, EMC.
Copyright 2009 FUJITSU TECHNOLOGY SOLUTIONS PRIMERGY Servers and Windows Server® 2008 R2 Benefit from an efficient, high performance and flexible platform.
Chapter 3 Chapter 3: Server Hardware. Chapter 3 Learning Objectives n Describe the base system requirements for Windows NT 4.0 Server n Explain how to.
Intelligent Storage Systems
Native InfiniBand Storage Deployment & Customer Experiences Dave Ellis Director, HPC Architecture LSI Logic IBTA & OFA DevCon San Francisco September 25,
© 2009 IBM Corporation Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change.
© 2009 EMC Corporation. All rights reserved. Intelligent Storage Systems Module 1.4.
Product Manager Networking Infrastructure Choices for Storage.
Intel  modular server building blocks ( built on Intel  Multi-Flex Technology ) Intel  modular server building blocks ( built on Intel  Multi-Flex.
© Hitachi Data Systems Corporation All rights reserved. 1 1 Det går pænt stærkt! Tony Franck Senior Solution Manager.
2730/2730T/5730 Performance Comparison 20 May 2008.
1 © Copyright 2009 EMC Corporation. All rights reserved. Agenda Storing More Efficiently  Storage Consolidation  Tiered Storage  Storing More Intelligently.
MaxTronic International Co., Ltd. May 2013 Focused on Data Protection.
Cluster computing facility for CMS simulation work at NPD-BARC Raman Sehgal.
Storage Survey and Recent Acquisition at LAL Michel Jouvin LAL / IN2P3
1 Storage Refinement. Outline Disk failures To attack Intermittent failures To attack Media Decay and Write failure –Checksum To attack Disk crash –RAID.
Database Services for Physics at CERN with Oracle 10g RAC HEPiX - April 4th 2006, Rome Luca Canali, CERN.
© Copyright 2010 Hewlett-Packard Development Company, L.P. 1 HP + DDN = A WINNING PARTNERSHIP Systems architected by HP and DDN Full storage hardware and.
Nexenta Proprietary Global Leader in Software Defined Storage Nexenta Technical Sales Professional (NTSP) COURSE CONTENT.
Introducing Snap Server™ 700i Series. 2 Introducing the Snap Server 700i series Hardware −iSCSI storage appliances with mid-market features −1U 19” rack-mount.
Nexenta Proprietary Global Leader in Software Defined Storage Nexenta Technical Sales Professional (NTSP) COURSE CONTENT.
Module – 4 Intelligent storage system
DAC-FF The Ultimate Fibre-to-Fibre Channel External RAID Controller Solution for High Performance Servers, Clusters, and Storage Area Networks (SAN)
Storage Systems Market Analysis Dec 04. Storage Market & Technologies.
InfiniSwitch Company Confidential. 2 InfiniSwitch Agenda InfiniBand Overview Company Overview Product Strategy Q&A.
1 U.S. Department of the Interior U.S. Geological Survey Contractor for the USGS at the EROS Data Center EDC CR1 Storage Architecture August 2003 Ken Gacke.
Switched Storage Architecture Benefits Computer Measurements Group November 14 th, 2002 Yves Coderre.
Introducing ULTAMUS TM RAID. The Need for Storage Immediate Accessibility Limited IT Staff Budget Constraints Data Growth Security Levels Retention Characteristics.
© 2010 DataDirect Networks. Confidential Information D D N D E L I V E R S DataDirect Networks Update Mike Barry, HPC Sales April IDC HPC User Forum.
5/8/09 Titanium Performance Update 2 Dot Hill Confidential.
Bosch DSA Storage (based on NetApp E2700)
Forschungszentrum Karlsruhe in der Helmholtz-Gemeinschaft Implementation of a reliable and expandable on-line storage for compute clusters Jos van Wezel.
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. HP Update IDC HPC Forum.
ONStor Pantera 3110 ONStor NAS. Copyright 2008 · ONStor Confidential Pantera 3110 – An Integrated Channel only NAS  Integrated standalone NAS system.
1© Copyright 2012 EMC Corporation. All rights reserved. EMC VNX5700, EMC FAST Cache, SQL Server AlwaysOn Availability Groups Strategic Solutions Engineering.
CERN Computer Centre Tier SC4 Planning FZK October 20 th 2005 CERN.ch.
CERN - IT Department CH-1211 Genève 23 Switzerland t High Availability Databases based on Oracle 10g RAC on Linux WLCG Tier2 Tutorials, CERN,
STORAGE ARCHITECTURE/ MASTER): Disk Storage: What Are Your Options? Randy Kerns Senior Partner The Evaluator Group.
Barriers to IB adoption (Storage Perspective) Ashish Batwara Software Solution Architect May 01, 2007.
SATA In Enterprise Storage Ron Engelbrecht Vice President and General Manager Engineering and Manufacturing Operations September 21, 2004.
Tackling I/O Issues 1 David Race 16 March 2010.
Copyright © 2010 Hitachi Data Systems. All rights reserved. Confidential – NDA Strictly Required Hitachi Storage Solutions Hitachi HDD Directions HDD Actual.
© 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice ProLiant G5 to G6 Processor Positioning.
FusionCube At-a-Glance. 1 Application Scenarios Enterprise Cloud Data Centers Desktop Cloud Database Application Acceleration Midrange Computer Substitution.
YOUR LOGO Retail File 23 May 2016 Valid Until 31 May 2016 or Until Stock Last HP SERVER DL380 G9 2U,6C E GHZ/15MB,16GB(2X8GB)R,P440ar/2GB,2x300GB.
System Storage TM © 2007 IBM Corporation IBM System Storage™ DS3000 Series Jüri Joonsaar Tartu.
E2800 Marco Deveronico All Flash or Hybrid system
EonStor DS 1000.
Ryan Leonard Storage and Solutions Architect
Video Security Design Workshop:
EonNAS.
iSCSI Storage Area Network
Appro Xtreme-X Supercomputers
Cluster Active Archive
Building continuously available systems with Hyper-V
IBM Power Systems.
Cost Effective Network Storage Solutions
FlashSystem 9100 with Epic Workloads
Presentation transcript:

Engenio 7900 HPC Storage System

2 LSI Confidential LSI In HPC LSI (Engenio Storage Group) has a rich, successful history of deploying storage solutions for the HPC market –Over 50 petabytes of LSI storage currently installed in HPC sites LSI is focused on the HPC market as a strategic opportunity –These customers have the most demanding technology requirements and are often a leading indicator for technologies that will soon move into the mainstream Examples include Linux clusters, Global File Systems, and InfiniBand –Making our technology available first to HPC customers benefits our General Purpose Computing, or GPC, products and customers ESG recently established a cross-functional team focused on the HPC market designed to ensure that we maintain our HPC leadership

3 LSI Confidential Robust storage management supports unparalleled configuration flexibility and online administration Scalability up to 480 TB satisfies the most demanding capacity requirements Bullet-proof reliability and availability to ensure continuous high-speed data delivery Flagship storage system designed for compute-intensive applications Engenio 7900 HPC Storage System

4 LSI Confidential The 7900 HPC storage system is uniquely positioned to deliver HPC-class performance with uncompromising uptime to ensure continuous high-speed data access Engenio 7900 HPC Storage System

5 LSI Confidential HPC Performance Industry-leading 6.4 GB/s on sustained reads from disk Lineage of balanced performance excels at mixed workloads Field-replaceable host interface cards adapt to changing infrastructure –4 Gb/s FC –20 Gb/s IB –8 Gb/s FC (future) –40 Gb/s IB (future) Reliability and Availability Proven architecture based on over 30 years of design knowledge and firmware development –Almost 400K systems shipped Uninterrupted data uptime –Five 9s availability –No single point of failure –Fully-redundant data path with automated failover –Battery-backed controller cache mirroring –Proactive drive health monitoring –Hardware-assist RAID 6 –Read parity check Performance + Uptime = Computational Efficiency

6 LSI Confidential Computational analysis Upstream/downstream processing Genomics Satellite ground stations Data-intensive research 3-D computer modeling Seismic processing Data mining Large-scale simulation 7900 HPC Positioning Ideal for environments that store vast amounts of data for high-bandwidth programs

7 LSI Confidential Government labs Biosciences Scientific research & development Energy, weather, climate Oil and Gas Media and entertainment Geospatial companies 7900 HPC Positioning Ideally suited to markets with high volumes of data processing and computing demands

8 LSI Confidential Key Features 7 th -generation XBB2 architecture delivers unprecedented performance, multi-dimensional scalability and unparalleled flexibility Balanced performance supports mixed workloads for applications ranging from transaction-heavy to bandwidth-intensive Fully redundant I/O paths, automated failover, battery-backed mirrored cache, and online administration keep your data accessible Field-replaceable host interface cards adapt to changing infrastructures Support for SATA drives and RAID level 6 allows administrators lower costs without sacrificing data protection Proven architecture benefits from more than 30 years of design knowledge and firmware development

9 LSI Confidential Specification Overview Key new features 7 th generation XBB2 controller technology –Custom ASIC with built-in hardware-assist for RAID 5 XOR and RAID 6 p+q –Four 2 GB/s PCI-Express X8 buses (two host, two drive) deliver 4 GB/s of internal bandwidth –Two dedicated 2 GB/s PCI-E X8 cache mirroring buses –Field replaceable host interface cards Dedicated data cache –Dedicated cache mirroring busses –Battery-backed and destaged to disk after power loss H P C Host/SAN connectivity Sixteen 4 Gb/s FC Eight 20 Gb/s IB Drive channels / drives Sixteen 4 Gb/s FC 480 – FC/SATA (256 initially) XOR and Cache Dedicated XOR engine 8 GB dedicated cache Battery-backed, mirrored Performance 6.4 GB/s sequential disk reads 5.4 GB/s sequential disk writes Dual-controller system specs

10 LSI Confidential Field Replaceable Host Interface Cards

11 LSI Confidential 6998 / 7900 HPC Specification Comparison Dual-controller system (unless noted) H P CImprovement Host channels8 FC16 FC or 8 IB2X Redundant drive channelsEight 4 Gb/sSixteen 4 Gb/s2X Max drives224 FC/SATA480 FC/SATA2X ProcessorIntel Xeon 2.4 GHzIntel Xeon 2.8 GHz--- Processor memory (single controller)Up to 1 GB2 GB2X XOR technologyDedicated ASICDedicated ZIP ASIC--- Bus TechnologyPCI-XPCI-Express2X Internal controller bandwidth (single controller) 1 GB/s4 GB/s4X Data cache (min/max)2 GB / 16 GB8 GB--- Cache Hold-upBattery backedPermanent2X Cache MirroringBack-end loops2 dedicated busses--- Cache bandwidth (single controller)3.2 GB/s17 GB/s5X

12 LSI Confidential 6998 / 7900 HPC Performance Comparison H P CImprovement Burst throughput cache read1,700 MB/s6,400 MB/s3.8X Sustained throughput disk read1,600 MB/s6,400 MB/s4X Sustained throughput disk write (CMD)1,300 MB/s5,400 MB/s4X Burst I/O rate cache reads575,000 IOPS700,000 IOPS1.6X Sustained I/O rate disk reads86,000 IOPS~ 172,000 IOPS (est)2X Sustained I/O rate disk writes22,000 IOPs~ 45,000 IOPS (est)2X ~ Performance numbers are preliminary estimates based on 448 drives and not committed. Actual results based on testing are to be determined. All numbers were done using RAID 5 using switched drive modules.

Questions

14 LSI Confidential 7999 Controller Block Diagram