Beam Diagnostics for ADS Dirk Vandeplassche SCK  CEN EUCARD-2 — MAX Accelerators for ADS CERN, 20-21 March 2014.

Slides:



Advertisements
Similar presentations
MYRRHA Injector at UCL Dirk Vandeplassche Luis Medeiros Romão SCK CEN MAX International Design Review Brussels, November 2012 Dirk Vandeplassche,
Advertisements

Issues in ILC Main Linac and Bunch Compressor from Beam dynamics N. Solyak, A. Latina, K.Kubo.
A U.S. Department of Energy Office of Science Laboratory Operated by The University of Chicago Argonne National Laboratory Office of Science U.S. Department.
1 ITC242 – Introduction to Data Communications Week 12 Topic 18 Chapter 19 Network Management.
SLAC ILC Accelerator: Luminosity Production Peter Tenenbaum HEP Program Review June 15, 2005.
Vegard Joa Moseng BI - BL Student meeting Reliability analysis summary for the BLEDP.
BI SW for LINAC4 On behalf of BE/BI/SW BI software development process Specifications List of BI Systems – Not covered: PSB ring systems Conclusions Lars.
Reliability Modeling of an ADS Accelerator SNS-ORNL/Myrrha Linac (MAX project) EuCARD 2, GENEVA (20-21 March 2014 ) CERN.
URIOT Didier - MYRRHA accelerator 1st International Design Review 11/12/ Instrumentation& operation aspects operation aspects URIOT Didier.
ESS DTL beam commissioning
Drive Beam and CTF 3 International Workshop on Linear Colliders 2010 October 22, 2010 Erik Adli, Department of Physics, University of Oslo and CERN Bernard.
SNS Integrated Control System EPICS Collaboration Meeting SNS Machine Protection System SNS Timing System Coles Sibley xxxx/vlb.
1 st EuCARD 2 annual meeting G Bellodi – CERN WP4 AccApplic Hamburg G Bellodi - CERN / EuCARD2 Annual meeting.
NON-SCALING FFAGs: questions needing answers Andy Wolski The Cockcroft Institute, and the University of Liverpool Department of Physics. BASROC-CONFORM.
Beam tolerance to RF faults & consequences on RF specifications Frédéric Bouly MAX 1 st Design Review WP1 - Task 1.2 Bruxelles, Belgium Monday, 12 th November.
Page 1 Designing for Health; A Methodology for Integrated Diagnostics/Prognostics Raymond Beshears Raytheon 2501 W. University McKinney, TX
Accelerators for ADS March 2014 CERN Approach for a reliable cryogenic system T. Junquera (ACS) *Work supported by the EU, FP7 MAX contract number.
TE-MPE-EP, RD, 06-Dec QPS Data Transmission after LS1 R. Denz, TE-MPE-EP TIMBER PM WinCC OA Tsunami warning:
20-21 March 2014 – EuCARD²/MAX Accelerator for ADS WORKSHOP, CERN D igital L ow L evel R adio F requency (system) for reliability-oriented linacs Christophe.
Controls-related R&D options Etienne CARLIER 18 th ABTEF meeting
Peter Spiller, DIRAC Kick-off meeting Peter Spiller Design Study Group DIRAC kick-off meeting SIS100.
Challenges of Dual Harmonic RF Systems ISIS Synchrotron Group John Thomason.
Luminosity expectations for the first years of CLIC operation CTC MJ.
PLC Workshop at ITER, 4-5 th of December 2014 A. Nordt, ESS, Lund/Sweden.
SPS re-commissioning with beam K. Cornelis PS-SPS days.
This material is based upon work supported by the U.S. Department of Energy Office of Science under Cooperative Agreement DE-SC , the State of Michigan.
Product & Technology Quality. Excellence. Support SIL Explanation 27.JAN 2006 Automation & Safety.
Machine Protection at the 1MW CEBAF Electron Accelerator and Free Electron Laser Facility Kelly Mahoney Presented at the Workshop for.
ESS LLRF and Beam Interaction. ESS RF system From the wall plug to the coupler Controlled over EPICS Connected to the global Machine Protection System.
Copyright © 2015 SCKCEN ADS accelerator developments presently on-going for MYRRHA and possibly for the Chinese-ADS Dirk Vandeplassche 1 Eucard-2 — APAE.
CERN Availability Working Group & Accelerator Fault Tracker Availability Working Group & Accelerator Fault Tracker - Where do we.
Dfernandez Computing & Controls Dec 3/4 MaxIV Control Systems for Accelerators and Automation David Fernández. ALBA Computing & Controls.
Introduction D. Schulte for K. Kubo and P. Tenenbaum.
EuCARD-2 is co-funded by the partners and the European Commission under Capacities 7th Framework Programme, Grant Agreement EuCARD-2, ADS, linacs,
Digital LLRF: ALBA and Max-IV cases RF&Linac Section - ALBA Accelerators Division Angela Salom.
Control System Considerations for ADS EuCARD-2/MAX Accelerators for Accelerator Driven Systems Workshop, CERN, March 20-21, 2014 Klemen Žagar Robert Modic.
Beam Interlock System Technology Evaluation and Design MACS Week 1, 2011 Hannes Pavetits 1 R. Gutleber PR a-HPA, March 28 th, 2011 H. Pavetits.
BEAM INSTRUMENTATION GROUP DEPENDABILITY APPROACH CERN, Chamonix 26th January 2016 William Viganò
Pushing the space charge limit in the CERN LHC injectors H. Bartosik for the CERN space charge team with contributions from S. Gilardoni, A. Huschauer,
Physics Department Lancaster University Physics Department Lancaster University Reliability Rebecca Seviour Cockcroft Institute Dept Physics Lancaster.
Interlock Systems for Machine Protection Manuel Zaera-Sanz Interlocks Engineer – ICS / Protection Systems AD and ICS Retreat mtg December 2014.
RF Commissioning D. Jacquet and M. Gruwé. November 8 th 2007D. Jacquet and M. Gruwé2 RF systems in a few words (I) A transverse dampers system ACCELERATING.
Summary of Session 1 - CLIC MP workshop 6-8/6/2012, R.Schmidt 1.
Machine Protection Systems (MPS) Arden Warner, and Jim Steimel Project X Machine Advisory Committee March 18-19, 2013.
1 & 2 JUNE 2015 – LLRF – BEAM DYNAMICS WORKSHOP URIOT Didier What is taken into account in simulations LLRF – Beam dynamics Workshop.
High-efficiency L-band klystron development for the CLIC Drive Beam High-efficiency L-band klystron development for the CLIC Drive Beam CLIC workshop,
M. Munoz April 2, 2014 Beam Commissioning at ESS.
Design process of the Interlock Systems Patrice Nouvel - CERN / Institut National Polytechnique de Toulouse CLIC Workshop Accelerator / Parameters.
WIR SCHAFFEN WISSEN – HEUTE FÜR MORGEN Steps towards beam commissioning: Low Level RF system group Thomas Schilcher :: Paul Scherrer Institut SwissFEL.
Registered participants participants from outside Cern.
Introduction; Machine protection, experience and challenges: Review of existing solutions and challenges faced by future installations Purpose of machine.
Challenges of Dual Harmonic RF Systems
Experience with beam instrumentation at Linac4
ADS reliability requirements
MPE-PE Section Meeting
Failure analysis at BEPCII
Accelerator Reliability requirements for ADS: the MYRRHA project goals
FAULT TOLERANCE TECHNIQUE USED IN SEAWOLF SUBMARINE
Fault Tolerance & Reliability CDA 5140 Spring 2006
LIPAc Control System Reliability improvements
Emanuele (ESS), Alessandro (CERN), Mikel (Tekniker), Hayley (ISIS)
Energy calibration issues for FCC-ee I. Koop, BINP, Novosibirsk
Challenges and Perspectives of Accelerator Driven Systems (ADS)
Update on Linac4 Status, Reliability Run and Modelling
LLRF Functionality Stefan Simrock How to edit the title slide
Accelerator Physics Technical System Group Review
CSNS Accelerator Control and Beam Instrumentation JIN Dapeng, XU Taoguang … June 9, 2015
Superbeams with SPL at CERN
VELA – CLARA AP (Draft) Goals Software Goals
The SPL-based Proton Driver at CERN
Presentation transcript:

Beam Diagnostics for ADS Dirk Vandeplassche SCK  CEN EUCARD-2 — MAX Accelerators for ADS CERN, March 2014

Introduction: framework 2 Dirk Vandeplassche, Eucard2 — MAX Accelerators for ADS Workshop, CERN, March, 2014 Accelerator for ADS: –modest in terms of beam energy and current performances –challenging for CW and beam-MTBF practical exploitation of a real machine: –ancillary equipment –diagnostic equipment –control system

framework Dirk Vandeplassche, Eucard2 — MAX Accelerators for ADS Workshop, CERN, March, LINAC ancillary equipment diagnostic equipment control layer CW beam MTBF > 250h

framework: present Dirk Vandeplassche, Eucard2 — MAX Accelerators for ADS Workshop, CERN, March, system subsystemdesign studyrealization ancillary classicFEEDindustry cryoACS [MAX]industry RFThales [MAX]industry controls LL slow-PLC-based LL fast, RTCosylab +tbd HL, integrationCosylabindustry diagnostics beamacc. team- othersacc. team- grey: small scale studies only acknowledged issues: industry standards some form of redundancy

Introduction The R&D need for new diagnostic devices is very small 2 main global questions regarding diagnostics: 1.consequences of ADS operation 2.consequences of the reliability goal Dirk Vandeplassche, Eucard2 — MAX Accelerators for ADS Workshop, CERN, March, see: CDT Deliverable D2.4 "Accelerator design related issues", Chapter 5

Global concepts: ADS operation 1.Consequences of the ADS operation of the accelerator onto the diagnostic system ? Dirk Vandeplassche, Eucard2 — MAX Accelerators for ADS Workshop, CERN, March, itemaccelerator design issue diagnostic rolediagnostic systemrequest, action HP CWmin. beam lossMachine ProtectionBeam Loss Monitorsµs-level response, shut off stability(specifications)transverse ctrl longitudinal ctrl BPM bunch length meas. "slow" feedback "fast" feedback currentvarying duty cyclerequested current on target, averaged at 0.1s level N/A on target! upstream current meas., beam centering device "medium" feedback to cycle definition (TS) energyconstant beam energyTOF

Global concepts: reliability Dirk Vandeplassche, Eucard2 — MAX Accelerators for ADS Workshop, CERN, March, Consequences of the accelerator reliability goal onto the diagnostic system ? mission: avoid beam trips — fast recovery from beam trips — foresee beam trips accelerator design issuesrole of diagnostic systemrequest fault tolerance (redundancy) automatic recovery fault detection automatic feedback maximize MTTF all subsystems all components (follow the rule) minimize MTTR(follow the rule) avoid the occurrence of interlocks automated tuning advanced supervision increase interlock confidence level evaluate interlock confidence level high quality analog acquisitions be predictive be highly reliable generate statistics Confidence

reliability How ? –at level of individual diagnostic device MTTF (obvious) include provisions for –self-diagnostics –self-evaluation –self-calibration –self-repair powerful low level controller (FPGA) –at the global level of a given diagnostic system : make the system overdetermined (redundant) –statistics –coherence checks –numerical confidence level generate enough data for predictive algorithms to be applied powerful high level controller Dirk Vandeplassche, Eucard2 — MAX Accelerators for ADS Workshop, CERN, March,

reliability based on : –highest quality hardware –highest quality timing system (WR to be evaluated) –models !! behaviour of individual components global: "virtual accelerator" –matched Control System Dirk Vandeplassche, Eucard2 — MAX Accelerators for ADS Workshop, CERN, March,

foreseeable R&D R&D issues : –availability of experimental platforms is limited –presently envisaged in MYRRHA context: IS + LEBT + RFQ not extensive enough for coherence checks with beam induced signals useful for individual devices: MTTF, self-checks high power SS RF amplifier small scale tests on feedback systems (e.g. beam current regulation) small scale tests on "virtual accelerator" –conceptual developments global models statistical tools Dirk Vandeplassche, Eucard2 — MAX Accelerators for ADS Workshop, CERN, March,

R&D Dirk Vandeplassche, Eucard2 — MAX Accelerators for ADS Workshop, CERN, March,

Conclusion and outlook ADS: diagnostics are facing contradictory requirements –full protection –perfect stability –0 false interlocks keyword: confidence = reliability + coherence border between device and control becomes very fuzzy diagnostic system as a whole to go into the reliability model main message: it is time to consider the diagnostics within the ADS accelerator R&D program. The subject (or items of it) may be of broader interest and profit from possible synergies with other programs. Dirk Vandeplassche, Eucard2 — MAX Accelerators for ADS Workshop, CERN, March,