Interference Analysis 2K Newly Improved Features :  Imperial & Metric Versions.  Verifies known Bushing O.D. & Housing I.D. values thus providing added.

Slides:



Advertisements
Similar presentations
Interference Analysis 2K Newly Improved Features : Imperial & Metric Versions. Imperial & Metric Versions. Verifies known Bushing O.D. & Housing I.D. values.
Advertisements

E2 Management Suite Employee Scheduling & Sales Forecasting
Access 2007 ® Use Databases How can Microsoft Access 2007 help you structure your database?
HX-Net HX-Net can extract stream connection information, physical properties and heat transfer coefficients from a HYSYS case. One can modify this information.
Stack-up Verification 2K Features :  Quick selection of Standard Parts via pull down menu lists.  Pop-ups prompt you to decide whether the extra washers.
FireRMS Credentials. Credentials  Objectives Customize Credentials Credentials Earned Scheduling and Tracking for Credentials.
What is GT MASTER WHAT IS GT MASTER? Thermoflow, Inc.
What is GT MASTER While GT PRO is the design program for combined cycles, GT MASTER is the corresponding simulation program for off-design calculations.
1 Authority on Demand Flexible Access Control Solution.
Linear Programming. Introduction: Linear Programming deals with the optimization (max. or min.) of a function of variables, known as ‘objective function’,
MACREX Indexing Software. Getting Started: Basic Basics.
A1 Acoustic Rhinometer The following presentation gives an overview of the main functions of the A1Acoustic Rhinometer, it’s accessories and normal operational.
Lesson 14 Creating Formulas and Charting Data
Housing Extranet RGI Calculation Forms By Dan Douglas Section 48 and Section 49.
Measuring tools Modern engines use thinner casting and require more precise measuring Selectively fit engines All parts are measured and marked according.
Introduction to Upgraded Version of UTS(T-Pax) PSC Travel Branch.
Selection of measuring instruments
Introduction to Structured Query Language (SQL)
ISO Method to Determine Tolerance
1 Seventh Lecture Error Analysis Instrumentation and Product Testing.
Rolling element bearings A. Lozzi 09
Database Design IST 7-10 Presented by Miss Egan and Miss Richards.
 A data processing system is a combination of machines and people that for a set of inputs produces a defined set of outputs. The inputs and outputs.
1 Editing A Power Architect Tree What if a user specifies a specific tree configuration?
Input Design Objectives
Computer Literacy BASICS
Database Applications – Microsoft Access Lesson 2 Modifying a Table and Creating a Form 45 slides in presentation Accessibility check 9/14.
EaTIS Vendor Training - FY EaTIS Training for Vendors – Process Overview EaTIS Version 3.01 Last Modified on April 5, 2007.
Chapter 3 Single-Table Queries
What is Sure BDCs? BDC stands for Batch Data Communication and is also known as Batch Input. It is a technique for mass input of data into SAP by simulating.
Encoding, Validation and Verification Chapter 1. Introduction This presentation covers the following: – Data encoding – Data validation – Data verification.
1 Lesson 19 Creating Formulas and Charting Data Computer Literacy BASICS: A Comprehensive Guide to IC 3, 3 rd Edition Morrison / Wells.
General Tolerance and Hole Fit
Chapter 3 PART 2 - SPREADSHEET CMPF 112 : COMPUTING SKILLS CALC FOR LINUX.
Ryan Kardell WFO Springfield.  Purpose of the Database  Data Sources  User Guide  Formulas Used for Scoring.
Cascade and Ratio Control
1 ADVANCED MICROSOFT EXCEL Lesson 9 Applying Advanced Worksheets and Charts Options.
CENTURY CONSULTANTS USER CONFERENCE 2009 MAY 13 TH – 14 TH.
CREATING TEMPLATES CREATING CUSTOM CHARACTERS IMPORTING BATCH DATA SAVING DATA & TEMPLATES CREATING SERIES DATA PRINTING THE DATA.
1 Single Table Queries. 2 Objectives  SELECT, WHERE  AND / OR / NOT conditions  Computed columns  LIKE, IN, BETWEEN operators  ORDER BY, GROUP BY,
T062:Q10. A metal rod has a length of 7.30 m at 15  C and a length of 7.40 m at 95  C. What is the temperature of the rod when its length is 7.21.
Touchstone Automation’s DART ™ (Data Analysis and Reporting Tool)
Access 2007 ® Use Databases How can Microsoft Access 2007 help you structure your database?
An Object-Oriented Approach to Programming Logic and Design Fourth Edition Chapter 4 Looping.
Derek Snow 6/13/2009.  What is Form?  Creating Forms  Form Views  Calculated Controls.
CSC 240 (Blum)1 Introduction to Access CSC 240 (Blum)2 Click on the Access desktop icon or go to Start/Programs/Microsoft Office/Microsoft Office.
Machine Design Under Uncertainty. Outline Uncertainty in mechanical components Why consider uncertainty Basics of uncertainty Uncertainty analysis for.
Animal Shelter Activity 2.
Project 2: Heat Exchanger Design Group Members: Brian Schludecker Phillip Palmer Adam Spindler Mike Hay Joe McGuire Presented 12/12/2006 to Dr. Toksoy.
TAX-AIDE Refund/Tax Owed Pub 4012 – Pages H-3 and K-3 Pub 4491 – Part 7 – Lesson 31.
Skill Editor. When you see a Red circle or a next button, like this, that means we want you to click on something. These are the same steps you’ll take.
EXCEL DECISION MAKING TOOLS BASIC FORMULAE - REGRESSION - GOAL SEEK - SOLVER.
PolyTech developed WinTXU Screw Configuration Manager in 2004 as the future Windows interface for TXS. In the meantime, WinTXU has been highly successful.
Jet Fuel Vaporization and Condensation: Modeling and Validation Robert Ochs and C.E. Polymeropoulos Rutgers, The State University of New Jersey International.
Chapter 3 Data Control Ensure the Accurate and Complete data is entering into the data processing system.
Project Setup and Execution For PMPlan Enterprise Presented by AlNik Solutions Copyright ©
EXCEL DECISION MAKING TOOLS AND CHARTS BASIC FORMULAE - REGRESSION - GOAL SEEK - SOLVER.
Information Technology Project Management, Seventh Edition.
USER GUIDE TEMPERATURE CONTROLLER TR-2006 Hot runner temperature controller ShenZhen TanRex Electronic Co.ltd.
1 DATA ANALYSIS, ERROR ESTIMATION & TREATMENT Errors (or “uncertainty”) are the inevitable consequence of making measurements. They are divided into three.
Questionnaire-Part 2. Translating a questionnaire Quality of the obtained data increases if the questionnaire is presented in the respondents’ own mother.
Page 1 TQC Mechanical Model Igor Novitski / Rodger Bossert May 24, 2006 Results of MM#4 and MM#5.
Sourcing Event Tool Kit Matrix Pricing & Tiered Pricing User Guide
Tunner / Halvorsen Parts Order Guide
Using the Excel Creation Template to Create a Variable Parameter Problem (Macro Enabled “Alpha 1.4.2”) Getting started – Example 1 Note – You should be.
Building Configurable Forms
Fun gym Cambridge Nationals R001.
Replacement Grade for Heating Curve Graph
Aleph Circulation Loans & Returns Version 19
This presentation document has been prepared by Vault Intelligence Limited (“Vault") and is intended for off line demonstration, presentation and educational.
Presentation transcript:

Interference Analysis 2K Newly Improved Features :  Imperial & Metric Versions.  Verifies known Bushing O.D. & Housing I.D. values thus providing added crucial information such as Interference, Liquid Nitrogen & Dry Ice Shrinkage, Insertion Clearance & Heated Housing Expansion if required based on those input values.  If input values are unknown, sheet 2 allows the user to input an approx. Pin Ø or Housing Ø to start, thus automatically activating toleranced output values for Housing I.D., Bushing O.D., Bushing I.D., Pin O.D. and the before chrome/H.V.O.F. Pin O.D. Fine tuning will then take place on sheet 1 whereby final values will be based on the final selection of materials, guided by listed remarks to achieve acceptability. Fine tuning will then take place on sheet 1 whereby final values will be based on the final selection of materials, guided by listed remarks to achieve acceptability.  Verifies whether an interference condition could exist between the Pin O.D. vs. Bushing I.D. over working temperature ranges. This is crucial pre-emptive information whereby the Bushing I.D. may have to be modified thus averting an interference fit when the aircraft is exposed to that required working temperature range. This is crucial pre-emptive information whereby the Bushing I.D. may have to be modified thus averting an interference fit when the aircraft is exposed to that required working temperature range.  If rework is required, on sheet 2 input the new Housing I.D. reworked size, thus a new Bushing O.D will be stated where an interference check is to follow. In this case the Bushing I.D. stated is to be ignored because the original values would be retained.

Imperial Version sheet 1

Imperial Version sheet 2

Example Step 1. (when Bushing O.D. & Housing I.D. values are unknown) Let’s say due to loads, a 3” Ø 300M Pin is required. The joint will be greased thru’ the lug, thus the bushing would require inner & outer grooves. The Housing material is 300M & the Bushing material is Alum. Nickel Bronze.

Example Step 2.

Example Step 3.

Resultant Bush O.D., Housing I.D., Interference and ‘Insertion clearance’ provided when ‘Liquid Nitrogen’ is used. Also insertion clearance for ‘Lined Bushings’ whereby ‘Dry Ice’ would be used. If there’s an interference shown at the insertion clearance, the Bush O.D. could be altered to avoid that interference, provided a minimum of.001” interference is maintained for the Bushing O.D. vs. Housing I.D. required working temperature ranges. If 158º is to be the max. temp. considered, then ignore the 194º block that some programs require. Example Step 4.

Example Step 5. (Pin O.D. vs. Bushing I.D. clearance verification) (*B) 2)Select appropriate button and the Pin & Bush I.D. values will be transferred from sheet 2. (Different values can be typed in) 1)Select buttons to change from Bushing & Housing Material to Pin & Bush./Housing Material and adjust materials selection as req’d. Actual* Bushing Effect Resulting clearance between the Pin O.D. vs. Bushing I.D. throughout temperature ranges. Ensure to alternate between the Bush./Housing Material Selection to obtain worst case values (Pin lowest clearance or interference) before Bush I.D. mod. 3) In order to obtain the worst case scenario (Pin lowest clearance or interference), alternate the Bush./Housing material. Then it’s just a matter of increasing the Bushing I.D. to ensure a Pin clearance. “ To obtain actuals, refer to the materials expansion & shrinkage rates shown on ‘sheet 2’. Take into account the bushing & housing effects.” (See Actuals) (Contact me if further explanation is required) *(Bushing ‘Al.Ni.Br.’ Effect shown) (See ‘Example Step 6‘ for Housing Effect)

Example Step 6. (Pin O.D. vs. Bushing I.D. clearance verification) (*H) Actual* Housing Effect 1)Select buttons to change from Bushing & Housing Material to Pin & Bush./Housing Material and adjust materials selection as req’d. Resulting clearance between the Pin O.D. vs. Bushing I.D. throughout temperature ranges. Ensure to alternate between the Bush./Housing Material Selection to obtain worst case values (Pin lowest clearance or interference) before Bush I.D. mod. 2)Select appropriate button and the Pin & Bush I.D. values will be transferred from sheet 2. (Different values can be typed in) 3) In order to obtain the worst case scenario (Pin lowest clearance or interference), alternate the Bush./Housing material. Then it’s just a matter of increasing the Bushing I.D. to ensure a Pin clearance. “ To obtain actuals, refer to the materials expansion & shrinkage rates shown on ‘sheet 2’. Take into account the bushing & housing effects.” (See Actuals) (Contact me if further explanation is required) *(Housing ‘300M’ Effect shown) (See ‘Example Step 5’ for Bushing Effect)

The Bushing Part Number can be entered. No limit to the quantity of Alpha Numerical characters. The more characters the smaller the size of the characters. Example Step 7.

Reference showing available ‘Double Groove’ bushing option.

Reference showing available ‘Single Groove’ or ‘No Groove’ bushing option.

Reference showing available ‘Housing I.D. Min.’ option. (Also used for ‘Rework’).

Metric Version sheet 1 (M)

Metric Version sheet 2 (M)

Final Remarks: Final Remarks: This is a very flexible interference analysis program, it allows the user to input known values or modify calculated program values prior to the output. This is a very flexible interference analysis program, it allows the user to input known values or modify calculated program values prior to the output. Though it calculates most of the toleranced values automatically and provides guiding remarks to achieve acceptability including control of maximal interference, the nature of material coefficients does have limits and when trying to achieve acceptable interferences in large diameters with certain materials there will be cases where it is not possible to attain an acceptable interference due to various factors. Though it calculates most of the toleranced values automatically and provides guiding remarks to achieve acceptability including control of maximal interference, the nature of material coefficients does have limits and when trying to achieve acceptable interferences in large diameters with certain materials there will be cases where it is not possible to attain an acceptable interference due to various factors. Generally interferences beyond 158ºF./70ºC. are considered special cases. Generally interferences beyond 158ºF./70ºC. are considered special cases. This program provides (as reference only) 400ºF./204ºC. in the event interferences are required in the brakes vicinity. This program provides (as reference only) 400ºF./204ºC. in the event interferences are required in the brakes vicinity. In conclusion, this program would be an asset to an organization that wants to: In conclusion, this program would be an asset to an organization that wants to: 1) Improve accuracy. 1) Improve accuracy. 2) Improve consistency. 2) Improve consistency. 3) Observe all results from only a simple Bushing O.D., Housing I.D. & Materials input. 3) Observe all results from only a simple Bushing O.D., Housing I.D. & Materials input. 4) Obtain automatic fit results from an approx. Pin Ø or a Housing Ø input. 4) Obtain automatic fit results from an approx. Pin Ø or a Housing Ø input. 5) Modify values on the fly to suit a specific output as the tables adjust automatically. 5) Modify values on the fly to suit a specific output as the tables adjust automatically. 6) Save many hours on analysis, it would only take minutes to obtain an accurate result. 6) Save many hours on analysis, it would only take minutes to obtain an accurate result. I may be contacted as follows: I may be contacted as follows: A license for use is available. A license for use is available.