Process Analyzer Sample Probe Assembly (SPA)

Slides:



Advertisements
Similar presentations
A force applied over a surface is pressure.
Advertisements

Malema Excess Flow Valves
Corrosion Products Sampler (CPS)
Manual Flo-tap Installation Instructions
Roger C. Ellis ECE Mechatronics Assignment #1.
Severe Service Metal Seated Ball Valves
Objective of the session.
REMOTE MEASUREMENT OF STRESS IN FERROMAGNETIC PIPELINES Motivation Ageing global pipeline infrastructure Non-invasive, remote, pipeline integrity assessment.
ExSite “ Sharing of Best Practices” The following illustrations of system interconnections are provided only as a guideline. Actual connections are dictated.
Gear Drive Flo-tap Installation Instructions Quick Installation Guides: rev. EA – 485 Flanged Flo-tap rev. DB – 485 Threaded.
New Mexico FFA Agricultural Mechanics Career Development Event Engine Power.
Larox Flowsys T HE S OLUTION Y OU ´ VE B EEN L OOKING F OR.
Hydraulics.
Chapter 11 Keys, Couplings and SealsRJM 3/16/04 Chapter 11 - Keys, Couplings and Seals How attach power transmission components to shaft to prevent rotation.
Gas Transmission Pipelines
Engineering H191 - Drafting / CAD The Ohio State University Gateway Engineering Education Coalition Lab 4P. 1Autumn Quarter Transport Phenomena Lab 4.
Flow Produced Noise & Fluid Mechanical Treatment Flow Produced Noise & Fluid Mechanical Treatment Prepared By: Eng. Ashraf Al-Shalalfeh Mechanical Engineering.
Chemical Engineering 3P04 Process Control Tutorial # 2 Learning goals 1.The feedback cause-effect principle 2. Key element in the loop: The control valve.
New Products for 2012 Wafer Check Valve. New Products for 2012 Wafer Check Valve Design was Initiated to fill void in size range for key end user specifications.
Advanced Manufacturing Laboratory Department of Industrial Engineering Sharif University of Technology Session #19.
DCP Meeting – September 12 th 2010 WP1/4: Leak Search & Repair- Paolo Petagna 1/9 PH-DT - WP1: REMOTE LEAK REPAIR- Update Report on status of leak analysis/quantification.
Lease Automatic Custody Transfer
Compressed Air Piping Systems by Asahi/America
1Furmanite Confidential - 1/9/04 Motor and Pump Base Foundational Repair.
New Mexico FFA Agricultural Mechanics Career Development Event Engine Power.
Thermowell Calculation Guide In accordance with ASME PTC 19.3 TW-2010
D-M-E Hot Runner Solutions D-M-E Hot Runner Capabilities.
HVAC523 Circulator Pumps.
ME421 Heat Exchanger and Steam Generator Design Lecture Notes 6 Double-Pipe Heat Exchangers.
Wedge Flow Element 1.
INTRODUCTION Definition:
Dr. subhash technical campus
Testing and Information
Temperature Control Loop
CXS490 Carbon Dioxide Systems
Use of Residual Pressure Valves - Challenges and Opportunities for Indian subcontinent. Presented By: Rohit Behani.
Mazzei Injector Company, LLC
Artificial Lift Systems
Flow Measurement and Control. Orifice Meter The orifice meter consists of an accurately machined and drilled plate concentrically mounted between two.
EMISSION PROBE PARTS TUBE: 3/8” OD x wall Stainless Steel Length determined by pipe diameter and placement of connecting end to allow easy connection.
Design Steps for Intake & Exhaust Systems
New Products for 2012 Wafer Check Valve. New Products for 2012 Wafer Check Valve Design was Initiated to fill void in size range for key end user specifications.
NCSX VACUUM VESSEL PL Goranson Thermal Insulation Final Design Review July 31, 2006 WBS12 NCSX.
WORKSHOP PRACTICE SAFETY VALVE.
1 HVACR316 - Piping Copper Tubing and Fittings. 2 2 Safety Refrigerant cylinders should be stored and transported in the upright position to keep the.
Mechanical Designs of The Central Detector Jinyu Fu
Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Converting ASME Tanks in Ammonia Service to Propane.
January 5, 2006 at Fermilab1 LAr TPC Wire Experiments B. Hansen.
SC Project Review of NCSX, April 8-10, 2008 NCSX Cryogenics Systems WBS-62 Steve Raftopoulos NCSX Cryogenic Systems WBS(62) Manager.
Esbe Rotary Motorized valves The ESBE Rotary Motorized valves (mixing valves and actuators) are used to control heating and cooling in buildings. We offer.
Valves In Industry (Part 1)
GOVERNMENT ENGINEERING COLLEGE, BHARUCH (014) Chemical Engineering department SEM-iii Sub: fluid flow operation topic: orifice meter & rotAmeter Guid by:
Heat Transfer Su Yongkang School of Mechanical Engineering # 1 HEAT TRANSFER CHAPTER 7 External flow.
L.J.INSTITUTE OF ENGINEERING AND TECHNOLOGY compressors Shah Aadishkumar Aileshbhai (enrollment no ) (div A roll no. 55) Guided by Mr.hemangsir.
PLAN PRESENTATION ABSTRACT. INTRODUCTION This system has been devised and developed by T.D.Williamson Inc. to enable pipeline operators to carry out maintenance,
FLUID FLOW FOR CHEMICAL ENGINEERING Dr Mohd Azmier Ahmad Tel: +60 (4) EKC 212 CHAPTER 8 (PART 2) TRANSPORTATION SYSTEM.
Welcome! Drafting 2345: Advanced Pipe Drafting Andrew Amini Full Time Instructor, HCC.
Presentation Title Presented by Joe Blow Beyond Flow and Pressure By: Tom Cabezut Western Regional Manager.
Fluid Mechanics for Chemical Engineers Arif Hussain (Lecturer)
Target Systems and Monolith Design Update Rikard Linander Group Leader Monolith and Handling April 2, 2014.
Valves.
Chapter 11 - Keys, Couplings and Seals
Chemical Engineering Drawing
GOVERNMENT ENGINEERING COLLEGE, BHARUCH.
Welcome! Drafting 2345: Advanced Pipe Drafting
The BioTector B3500ul TOC analyzer Process Tests
Gasket Fabricators Association Technical Committee Presentation
TRENTON Casing Filler Presentation
Pipe fitting Threads on pipe fittings are tapered and rely on the stress generated by forcing the tapered threads of the male half of the fitting.
Gas Transmission Pipelines
Presentation transcript:

Process Analyzer Sample Probe Assembly (SPA)

Bet this never happens….? WARNING TAG READS: “DO NOT SHUT VALVE WITH PROBE INSERTED”

What is a Sample Probe Assembly? The Conax Sample Probe Assembly or “SPA” is designed to insert and retract a Sample Probe into a closed-loop pressurized process pipeline though a process isolation valve. The use of a Sample Probe facilitates the extraction of a representative product “Sample” (gas and / or liquid) from the process pipeline. The extracted sample is then analyzed to measure its physical and chemical properties. Sample Probes can be either a Retractable or Fixed Design. A retractable design allows the Sample Probe to be completely removed from the process pipeline whereas as fixed probes are permanently installed. Retractable Sample Probes can be replaced in the event they become plugged or corroded. In order to insert / retract a Sample Probe into a pressurized process pipeline, a process isolation valve and Compression Sealing Gland are required. The use of a Conax Packing Gland (PG) with either a Teflon® or Grafoil® Sealant has been the recognized “solution” in the Oil & Gas Industry. A Sample Probe can be either tubing or pipe fabricated from various materials as required by the process conditions. The common rule of thumb is to position the tip of the Sample Probe one-third to one-half into the inside diameter of process pipeline. Under high flow-rate conditions, this immersion depth will need to be reduced and / or supported via a nozzle support.

The angled end of the Sample Probe is typically positioned downstream to flow. Sample Probes with angled ends are designed to exclude dust, pipe-scale, and liquid drops from the extracted sample. The principal is momentum. If the particles and drops are heavier than the process fluid, they will be reluctant to make the sharp turn into the angled-end.

Operator Safety must be always be considered. Conax’s SPA is used to insert a Sample Probe into a pressurized and sometimes caustic closed-loop system, therefore Operator Safety must be always be considered. Conax’s SPA Design takes this under consideration with: Plasma Welded Stop Collar Optional Retaining Chain Kit SST Warning Tag The end-user is ultimately responsible for the operation of the SPA since the Conax PG gland is only rated for static conditions at full torque. Refer to the USER CAUTIONS on Conax’s SPA Bulletin.

What does Conax offer? Single source to insure correct design, materials and fit of the Sealing Gland to the Sample Probe. Capability to supply both the Sealing Gland and Sample Probe from various materials such as 316SST, 316LSST, NACE316SST, Monel, Hastelloy C276 and Hastelloy C22 based process corrosion requirements. Plasma welded machined stop collar. If the SPA is coated or electro polished we weld both sides of the collar eliminating crevices. SPA assemblies are available with an optional Retaining Chain Kit Sample Probes are available with laser markings to indicate installation depth and/or UPSTREAM and DOWNSTREAM orientation relative to the angled end. Experience selling to major Oil & Gas accounts worldwide. A SPA quote request form is available to identify the full range of process conditions such as Velocity, Pressure, Temperature, Physical Dimensions and Material Requirements Stress & Wake Frequency Analysis of probe can be performed to validate the probe design if desired.

PG Gland Body with “Bonda Relief” Counterbore Options… PG Gland Body with “Bonda Relief” Counterbore Integral metal ferrule provides: Secondary Mechanical Support Positive insertion depth stop “Bonda Relief” credited to Mr. Joe Bonda Sr. Analyzer Engineer at ExxonMobil Chalmette, Louisiana

Stress & Wake Frequency Analysis Overview (B) SPA Quote Request Form (C) In-house FEA Capabilities Calculations are based on ASME PTC 19.3 TW-2010 Pipewells and SPA’s fall outside the scope of the ASME PTC specification but methods for predicting the Frequency Ratio and Stress levels within the probe can be applied to the SPA in an effort to validate acceptability of the probe design. To perform the analysis it is vital to have the SPA Quote Request form filled out with key design details noted (i.e., fluid properties, geometry details, materials, etc.) For complex geometries, in-house FEA capabilities are also available for predicting Natural Frequencies & Stress levels. (A) Sample Analysis Report (one per unit)

Laser Marked Sample Probe Laser Markings “---DOWNSTREAM---” and “---UPSTREAM---”

Sample Probe for a Cooling Water-Free Chlorine Analyzer ½” Sch 40 Hastelloy C276 Pipe Sample Probe with Hastelloy C22 Sealing Gland Body and Flange

Sample Probe with Nozzle Support & Tapered Stop Collar

Design Benefits of the Sample Probe Tapered Stop Collar Serrated Flange Face Reduces flow-induced vibration by reducing the unsupported insertion length (“U”) for higher velocity applications Insures the precise insertion of the Sample Probe, Conax supplied Support Nozzle allows for a smaller diameter Sample Probe for Higher Pressure applications (πD2/4 x pressure) Reduces the entry of process fluids into the nozzle and the process valve Dia P(psi) F(lbs) ¼ 100 19.6 ⅜ 29.4 ½ 39.3 ¾ 58.9 1 78.5

Custom Engineered Sealing Glands for Critical Sample Probe Applications Extraction Port Secondary Sealant Primary Sealant

Adjustable Sample Probe with Special PG Body and Integral Kalrez O-Ring

Fixed / Welded Sample Probe Other designs… 1¼” dia. x .120” wall with 2” ball valve Fixed / Welded Sample Probe Injection Quill with Spray Nozzle

Thank you for your time – if you have any questions e-mail SPA@conaxtechnologies.com