Force & Lift Pump RAJASTHAN EXPERIENCE. Present scenario Unclean toilet – closed toiletsone drinking water point – one hand washing point.

Slides:



Advertisements
Similar presentations
Steering Systems Chapter 44.
Advertisements

Sectional Assembly and Installation
CARTRIDGE SEAL INSTALLATION. CHECK PUMP SHAFT FOR BURRS CHECK GLAND BOSS FOR NICKS LUBRICATE SECONDARY SEALS SLIDE SEAL ONTO PUMP SHAFT ASSEMBLE PUMP.
“The Strength of Experience”
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only Publisher The Goodheart-Willcox Co., Inc. Tinley Park, Illinois.
Manual Flo-tap Installation Instructions
Servicing Welch DRYFAST ULTRA Pump Models 2032
Technical support provided by: Highly Pathogenic Avian Influenza Control Programme SOP Use and Maintenance of High Pressure Washer Machine Market chain.
3.1.9 Student Book © 2004 Propane Education & Research CouncilPage Replacing Valves and Fittings in ASME Tanks Replacing ASME tank valves and fittings.
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
Installation. Indoor Unit Installation Typical Installation.
ZIPP 404 BEARING REPLACMENT GUIDE Tools Needed:
Yamaha oil pump rebuild
Chapter 11, Section 4. Changing a Shower Head 1.Turn off the water. 2.Remove the old showerhead. 3.Clean the showerhead stem of any corrosion or buildup.
Lab Equipment Pre-AP Chemistry.
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
WASH Cluster – Groundwater Pumping GWP GWP1 1 Groundwater Pumping Session 1 Handpumps.
Pulleys Vanderbilt Student Volunteers for Science Fall, 2010 Training Refresher.
Gear Drive Flo-tap Installation Instructions Quick Installation Guides: rev. EA – 485 Flanged Flo-tap rev. DB – 485 Threaded.
"AIR COOLER" Heat Exchanger
Component Rebuilds John Richards Cashman Product Support Representative Lyle Kibbe Cashman Service Supervisor A Guided Tour Through Cashman Equipment.
Pump Installation Vigyan Ashram, Pabal.
General idea of a couple of check rod system and adjustments
Installation. Indoor Unit Installation Typical Installation.
Rainwater Harvesting.
CARBURETED FUEL SYSTEM
Hydronic Mechanical Controls
Hydraulics For The Long Term
Submitted by Waris jamal Praveen kumar gautam Shiv pratap singh Ramashwar kumar singh Under the guidence of Prof.safiulla khan.
Plan 2 – Dead-end Seal Chamber Optional Jacket
Lec.16 Underground pipeline irrigation system - structures for underground pipelines.
Floating Head Heat Exchanger
“Fix Tube Sheet” Heat Exchanger
Blade Tuner assembly Instruction for tuner assembly on a cryomodule May
Trade of Plumbing – Phase 2 Module 2 – Unit 9 Module 2: Domestic Hot and Cold Water Services Unit 9 – Valves and Taps Duration – 11 Hours.
Framed Canopy Fitting Instructions Contents – 6- Angled frame fixing brackets 1 x handle pack 6 x self drilling tech screws 3 keys 1x door 6 x coach screws.
© Penn State Food Safety and Sanitation for Food Manufacturers Course Equipment Sanitary Design.
994 2½ ”- 10”. Modification Overview  Production for the 994 began in 1999 and is current.
3.7.7 Student Book © 2004 Propane Education & Research CouncilPage 1 Replacing DOT IM tank valves and fittings requires careful application of precautions.
Interior Design I 9.00 Home Maintenance Explain the benefits of interior home care.
Perforated PVC pipe attached with PVC tank. Folded galvanized sheet as drain tray over metal supports. Dual side operation and use ADVANTAGES · Can be.
ENGINE REASSEMBLY Chapter 12 Classroom Manual page 311
How do we harvest rainwater and why should we.. Why Harvest Rainwater? Decrease the volume of potable water used for irrigation. Recharge the groundwater.
How To Install a Centrifugal Water Pump. Installation Process First of all, consult the manual book to determine the right process of installation.
Sentek Training Presentation © 2003 All rights reserved Sentek Pty Ltd Sentek Sensor Technologies Installation of EasyAG 50 and EasyAG 80.
INSTALLATION MANUAL FATL Machine Installing: ACTIVITY CHECK POINT 1. Minimum two persons required for opening the Machine. 2. Cut the straps & tape. 3.
774X DCDA 21/2”, 6”, 8” 774X DCDA 21/2”, 6”, 8”. Modification Overview  Production began in  The 2 ½” 774X DCDA was discontinued in  The.
AMP 101 Product Line 320 Series Vertical Sump.
The PlayPump COST: $14,000 World Bank Development Marketplace Award Winner, 2000 Description The PlayPump utilizes a modular play wheel mechanism.
Instructions for Diaphragm Replacement Cat. Nos. 2052B-01, 2054B-01
System One Pumps S1-101 Construction and Features
NA62 LAV Anti1 REMOVAL & TESTS
774X 21/2”, 6”, 8”.
2000SS 2½”-12”.
Stop Valve – Types, Application and Working
Servicing the Steering System
What are the Parts Need to Replace For Resolving Transmission Fluid Leaks.
The AfriDev Pump COST: $10,700
Fuel Supply System Service
Floating Head Heat Exchanger
Disassembly and Assembly of A900C-W Electronic Governor Actuator for P8 Fuel Injection Pump
Suryoday Technologies ISO 9001:2015 Co.
774 DCDA 21/2”-12”.
4D-100, 4D-600 2½”- 10”.
VG INSTALATION & MAINTENANCE.
2000SS 2½”-12”.
774 2½”-12”.
3000SE 21/2”, 6”, 8”.
Presentation transcript:

Force & Lift Pump RAJASTHAN EXPERIENCE

Present scenario Unclean toilet – closed toiletsone drinking water point – one hand washing point

Present Scenario in rural schools Only one water point – being used for drinking water & hand washing by number of students Unclean toilets –No water in toilets No proper hand washing facilities –long queue at one water point No power supply –to operate water pump to lift water to over head tanks in case of power pump provision SIMPLE SOLUTION FORCE & LIFT HAND PUMP

Force & Lift pump FEATURES Adaptable to existing India Mark II and India Mark III installation. Uses commonly available components for the adaptation mechanism. Easy operation and maintenance. Lifts water efficiently up to 100 feet above the pump's water tank level. No power connection required Also capable of delivering water at ground level, like standard hand pumps. Standard tools for IM II & IM III sufficient for installation.

Force & Lift pump

eYVh Vsi gS.MiEi ls ikuh 'kkSpky; rd

Installation-1 Replace top ms rod with SS rod Replace threaded spout or threaded nipple welded spout Make provision for water point at ground level Fix non return valve on extended spout

Installation-2 Fix sealing gasket (rubber sheet) below third plate, on water tank to prevent leakage

F & L pump Installation – 3 Replace third plate with modified plate having hub for holding gland rubber ring

Installation-4 gland packing

Installation-5 Improve environmental sanitation

Installation-6 Install water tank on supporting structure or on roof Connect supply pipe from non return to water tank

Always keep tap near HP spout in third plate level to keep gland bush always in water, it will improve its life.

Install drinking water points / hand washing points

Install water points in toilets

Second Type – See & Saw Force & lift System

Make it play pump

Merry-go-round Sea-Saw Rajsamand

Play pumps -2

Play pump -3

Final Check list 1.All nuts & bolts are fully tightened, check nuts provided 2.Free movement of handle 3.No lateral play 4.Discharge minimum Vlom liter/40 stroke/minute Vlom liter/40 stroke/minute IM II 32mm - 12 liter/40 stroke/minute 5.Check for leakage 6.Water tank is clean, chlorinated & properly covered 7.Collect water sample in H 2 S & examine for bacterial contamination

Operation & Maintenance of Pump Correct handling will keep away breakdown Operate HP gently giving long, slow strokes Operate by standing on foot stand, gripping at end only, Do not bang the handle Keep regular watch on gland rubber ring. Ensure no leakage near third plate & water taps Prevent children putting anything inside, Keep platform & drain always clean Inform village mechanic immediately if hp is not functioning properly

Preventive maintenance of pump 1.Operate pump & check discharge Idle strokes not more than five Note any major change in discharge 2.Check HP stand firm on base Handle – play in limit, not rubbing Leakage from rubber gasket / gland packing /water taps 3.Grease the chain, replace gland rubber ring if required, replace washers for taps, clean head assembly 4.Tighten all nuts 5.Clean water tank on regular interval

24 hours water available for drinking for hand washing for toilet use go for FORCE & LIFT HAND PUMP Thanks