Closed Circuit - Positive Pressure Self-Contained Breathing System

Slides:



Advertisements
Similar presentations
General Safety Overview and Information
Advertisements

SKA-Pak Plus Mobile Air Cart Con-Space Link
Compressed Gases Slide Show Notes
Using Gas Welding Equipment
East Carolina University Compressed Gas Safety Training Program
Compressed Gas Cylinder Safety
PPE (Personal Protective Clothing)
Blackwood Fire Company SCBA Refresher. Regulations NJ PEOSH 12: Respiratory protection devices OSHA 29CFR Operating Guideline 7.2 Firefighter.
HVAC523 Soldering.
2 Fire Fighter Qualifications and Safety Skill Drills.
Scott 4.5 Introductory SCBA.
TESTING Dräger PSS 7000 Breathing Apparatus GENERAL TEST
SFFMA Training Objectives: –
Radiation Protection Technology Respiratory Protection Air Sampling Radiological Safety and Response RPT-243-PE-6.
UNIT: Oxy-Fuel Welding, Brazing, Cutting and Heating LESSON: OXY-ACETYLENE EQUIPMENT SAFETY Standard B7.2 – Know how to properly set up, adjust, shut down.
Harkness career center
Oxygen Administration R/C MERT Medic Assistant Lesson V.
Stanley DS11 Diamond Saw.
General Rules Compressed gases and cylinders must be properly stored, transported and used to prevent injury and accidents. Compressed gases and cylinders.
Copyright  Progressive Business Publications Blue Ridge Safety Association Safety Presentations Compressed Gasses.
Oxyacetylene Torches.
Intermediate SFFMA Objectives: – Hrs received.
VRFA 2011 Annual Respiratory Training. Objectives Hazard Recognition Understand current components Review daily, weekly, and after use inspections Review.
A Manual for Repair and Maintenance Technicians 1ST STAGE.
Unit: Oxy-Acetylene; Welding, Brazing, Cutting & Heating
How would you explain this on the 3394? If Fire Erupts on YOUR Boat If Underway, stop the boat Have everyone who is not wearing a PFD put one on Position.
THE M-9 9MM SERVICE PISTOL
What we do and why we do it. Know how to inspect an SCBA bottle for damage prior to fill Know how to use the compressor Know how to document problems.
Oxy Fuel Cutting Systems Basic Setup & Use
Oxy-fuel Welding and Cutting By: John Templeton
Terms and Definitions Base Metal: Metal to be welded Fusion Welding: process that joins metals by heating them to a melting point and allowing them to.
Zettl Group Safety Talk ~Fume Hoods~ 09/28/06 Takashi Ikuno.
SCRAM Emergency Escape Hood.
Bullard PA20 Powered Air Purifying Respirator (PAPR) Training Material
F LOTEC Training Presentation for Authorized Repair Centers This presentation is designed to supplement M-Service Manual InGage Regulator.doc Flotec, Inc.
S.C.B.A. MAINTENANCE By: Lt. Eric Miller Parksville Fire Department.
Powered Air-Purifying PARTICLE Respirator (PAPR) Copyright © 2013 by The S.E.A. Group.
CLASSES OF FIRE Class “A” – combustible materials
Aircraft Systems Oxygen Systems A-4N/TA-4. Aircraft Systems Oxygen System LESSON OBJECTIVES To give the TP information on the Oxygen System to include.
Self Contained Breathing Apparatus (Positive Pressure) Open Circuit SCBA.
Powered Air-Purifying Respirator (PAPR) Copyright © 2015 by The S.E.A. Group.
1. The 3M manufactures 2 types of Powered Air Purifying Respirator (PAPR) to be worn to provide respiratory protection for those staff members who have.
Respirator Safety This Training Covers Respirator Inspection User Fit Checks Respirator Cleaning Respirator Storage.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only Publisher The Goodheart-Willcox Co., Inc. Tinley Park, Illinois.
BioPak 240 Controls, Displays, Checkout Procedure, and donning and use under Normal and Emergency Conditions.
R espiratory Protection In Compliance With: 29 CFR Cummins Southern Plains, Ltd.
Respiratory Safety Public Safety Murray State University.
1 HVACR316 - Piping Soldering. 2 Soldering Copper Tubing The most common method of joining copper tubing in hydronic heating systems is soft soldering.
Orientation and Annual Refresher Training
1 Fire Fighter Qualifications and Safety Skill Drills 2.
1 Skill Drill 2-7 Donning a Face Piece Step 1: Fully extend the straps on the face piece. Step 2: Place your chin in the chin pocket. 2 Step 3: Fit the.
PERSONAL PROTECTIVE EQUIPMENT State of Georgia BASIC FIRE FIGHTER TRAINING COURSE.
FFII Module A Hillcrest Fire Department © 2001
Tempest Blower SECTION: Tools and Equipment ISSUED: REVISED: ##-####
Clearing Procedures. DISASSEMBLY Major Groups Barrel Group Turn the cover latch and raise the cover group Grasp the retracting slide handle with the.
VRFA ANNUAL RESPIRTORY PROTECTION. THE ADMINISTRATOR.
Discover the Dosmatic Difference Maintaining your Dosmatic injector for years of service.
1 RESPIRATORY PROTECTION TRAINING RESPIRATORY PROTECTION TRAINING Information from OSHA Standard And SCOTT 2.2 SCBA Manual Lesson prepared by.
RESPIRATORY TRAINING. Objectives + Why are respirators are necessary + Capabilities & Limitations + Inspecting & Maintaining + Medical Clearance & Fit.
Fire Fighter Safety SCBA CHANGE/REFILL
Rapid Change Technology The following is a presentation to aid Technicians in the replacement of the Rapid Change Technology Block.
Oxyacetylene Fusion Welding Safety Review
Copyright © 2016 by The S.E.A. Group
BASIC GAS METAL ARC WELDING
14 Refrigerant Recovery, Recycling, and Recharging.
Respiratory Protection Training
East Carolina University Compressed Gas Safety Training Program
Part 2 – Supplied-air Respirators
Concorp, Inc. - Respiratory Protection Training. Revision – B
Presentation transcript:

Closed Circuit - Positive Pressure Self-Contained Breathing System BIOMARINE BioPak 240 Closed Circuit - Positive Pressure Self-Contained Breathing System

This Presentation Developed Using the Biopak 240 Operation and Maintenance Manual

Closed Verse Open Circuit Open circuit – Compressed air (79% Nitrogen and 21% Oxygen) is regulated into a face piece for breathing. Exhaled gases are vented to the atmosphere. Closed circuit – Exhaled gases are recycled with 100% Oxygen make up gas added. All CO2 is absorbed with LimePak.

Warnings All users of the BioPak 240 self-contained breathing apparatus must be trained by qualified instructors in donning, operation, inspection, and emergency use procedures. All repairs to the BioPak 240 must be performed by Biomarine Inc, or certified Technician

Warnings Cont….. Medical qualification to wear a respirator is required prior to using the BioPak. A quantitative fit test with the Scott or Interspiro AGA face mask must be passed prior to use of the BioPak.

Warnings Cont….. Warning symptoms that require immediate evacuation from contaminated area are: Nausea, Dizziness, or Illness Severed pressure gauge line Difficulty inhaling or exhaling Over actuation of the demand valve Leaks of any kind

Compressed Oxygen Hazard Always handle oxygen cylinder with care to prevent rupture. Do not permit oil, grease or other combustible material to come in contact with the cylinder or cylinder valve to prevent ignition. Do not open the cylinder valve in the presence of open flame or sparks to prevent ignition. Failure to heed this warning may result in personal injury or death due to sudden release of high pressure oxygen and/or fire. BioPak 240 unit will vent, & may create an enriched O2 atmosphere in close spaces. Do not use in open flame environments.

Oxidizing Agent Hazard Oxygen is a non-flammable gas: however, it enhances the combustion of other materials. Oxygen enrichment decreases the energy necessary for ignition of materials.

Introduction The BioPak 240 is a positive pressure, closed circuit SCBA. The system removes carbon dioxide through LimePak absorption system. An 92db audible alarm will sound for 30-90 seconds when there is approximately 1-hour of breathing time left.

Components The following are the major components of the BioPak 240. All users need to be able to identify and understand the major components prior to use.

O2 Cylinder Cylinder fill pressure 3,000 psi. Only Medical grade oxygen. Hydrostatically tested every 5 years. Ensure tank is never completely emptied. Maintain at least 200 psi, to prevent ambient air & moisture from entering the cylinder. Cylinders at 0 psi must have vacuum pulled to eliminate contaminates.

On/Off knob Pressure gauge Manufacture Information

Finger prints leave behind oils & can be a hazard! Valve seat Finger prints leave behind oils & can be a hazard! Pin safety system

Oxygen Cylinder Replacement Make sure the stat-o-seal is clean, and seated properly on the yoke. Make sure the valve assembly of the oxygen cylinder is clean of any oils, lubricant and dirt, including finger prints. Insert the valve assembly of the oxygen cylinder through the regulator assembly. Align the two-pin safety system, and seat the bottle to the yoke and regulator assembly.

Oxygen Cylinder Replacement Carefully tighten the yoke screw that holds the oxygen cylinder to the regulator. Tighten the Velcro strap on the O2 cylinder. Open the valve on the cylinder. If a leak is heard, repeat steps. If the cylinder continues to leak at the regulator, replace the stat-o-seal. Verify the whistle chirp. If cylinder leaks, tighten yoke screw and/or repeat steps. If yoke area is not protected unit must be stored with O2 bottles installed.

Pressure Gauge BioPak 240 is provided with a luminescent chest mounted pressure gauge. Gauge indicates service life only when O2 cylinder is opened. Gauge will take up to 1 minute to read full pressure, due to flow restrictor. If severed gauge line occurs, flow restrictor will limit flow to 0.5 l/pm to allow safe egress.

Pressure Gauge Approximate pressure readings/safe working time: 3000psig = 4 hours. 2250psig = 3 hours. 1500psig = 2 hours. 750psig = 1 hour.

Yoke Keep Yoke and Regulator area clean!!!!! Check the placement and condition of the STAT-O- SEAL. Pin Safety System.

Regulator Operation Factory adjusted regulator reduces the pressure from the O2 cylinder to approx. 265-275 psig. A flow function test is performed during the the turn-around process. The regulator is designed to fail in the open position. A failing regulator will be identified by an extremely high flow reading during the flow test. User’s are not authorized to adjust, modify, or repair any parts of the regulator.

Yoke can always be stored with the rubber valve cap when not in use.

Emergency Bypass Valve Emergency bypass valve is for emergency use only. The valve will add additional oxygen over and above the constant flow and demand valve. Valve rate is 80-100 l p/m Can be manually operated if the user is not receiving enough O2, allowing O2 to flow directly into the breathing chamber. To operate the bypass valve push button for 2 seconds to add O2 to the breathing chamber.

Emergency Bypass Valve valve button If use of the bypass is necessary the user is to evacuate the zone. Caution, excessive use of the emergency bypass will significantly decrease the duration of the BioPak. Use of the bypass will not clear a fogged face-piece.

Alarm Whistle The BioPak 240 is equipped with a audible 92db alarm whistle. The alarm will sound for 30-90 seconds, when cylinder pressure drops to 600-750 psig, or 20 - 25% of the unit service life. Once alarm sounds user has approx. 1 hour of work time remaining.

Alarm Whistle Alarm whistle When the Biopak 240 is turned on, the user should hear a chirp from the alarm to signal that the alarm is working properly. Alarm will also chirp after unit is turned off, with more than 750 psig remaining in O2 cylinder. Alarm whistle

Cooling System The CO2 absorption process of the BioPak 240 generates heat. This heat is removed by use of the gel tube. Cooling medium is non-toxic “gelled water.” Good for 4 hours at an ambient temp of 75 degrees F. NOT A CORE BODY COOLING SYSTEM. Place canister in standard freezer in a horizontal position for at least 8 hours if completely thawed.

Cooling System Gel tube Foam pad Cooling canister Cap w/O-ring

CO2 Absorbent Canister In the absorbent canister, carbon dioxide (CO2) which is generated by the human body as a by-product of metabolism, is chemically removed from the breathing gas mixture. It is important to remove this out of the recycled breathing gas as it can be toxic over a period of time. The BioPak 240 uses LimePak to absorb CO2 by the following equation: CO2 + Ca(OH)2 = CaCO3 + H2O Or: Carbon Dioxide + Calcium Hydroxide = Calcium Carbonate (limestone) + water Or base + acid = salt

Foam pad Base Cover Limepack

Carbon Dioxide Absorbent Filling Ensure the absorbent canister has been disinfected and the white disk is completely dried. Using LimePak fill the canister with absorbent to the fill line and outer ring line (up hill). Foam pad should be seen protruding from each hole in the stainless steel lid. If movement is felt & heard when canister is lightly shaken, open and top off with more LimePak.

Carbon Dioxide Absorbent Canister Installation Ensure canister o-ring is in place and properly lubricated using DOW 111. Press canister into place in the breathing chamber, and replace stainless steel cover. Ensure all cover snaps are engaged properly, and label is properly orientated.

Absorbent Replacement The absorbent must be replaced: Each time the unit has been used. If ambient air is introduced into the system for more than 1-hour. Units may be stored with filled absorbent canisters for up to 1 year provided the LimePak has not expired.

Units will be stored with the Stainless Steel Lid turned 90°, to identify empty canister

LimePak Shelf life of five years. Once opened the LimePak has a shelf-life of one year. The keg must be marked with the date opened. The spent LimePak is non-hazardous material.

Interspiro AGA Mask

Exhalation side Inhalation side

Interspiro Mask The mask can be fitted with anti-fog insert lens. Coat the lens with anti-fog agent, and allow to dry completely. A slight haze should be seen on the inside lens. Speaking diaphragm use: Talk a little louder than normal. Don’t shout. Enunciate words. Speak clearly and slowly. Do not talk fast.

Pre-use Inspection Obtain BioPak 240 and frozen gel tube insert. Make sure unit is tagged for use. Fill the CO2 absorbent canister, and insert into the breathing chamber. Ensure O2 cylinder is pressurized to a minimum of 3000 psig. Check the alarm whistle for proper functioning. Ensure anti-fog agent has been applied to mask. Insert the frozen gel tube into the cooling canister.

Donning Procedures Place BioPak 240 with the harness up. Lengthen the shoulder straps so that the free ends extend two or three inches. Don the BioPak 240 like a suit coat.

Donning Procedures Bend at the waist and pull the shoulder straps tight onto your shoulders. You may loosen the shoulder straps to let the weight of the unit rest on your hips if desired. Tighten the waist belt. Connect the chest strap, do not over tighten because it will constrict breathing. Don facemask.

Donning Procedures Perform face mask check by blocking the inhalation port with your hand and inhaling. Mask should collapse on to your face. However, if mask leaks when you inhale with the inhalation port covered, adjust mask for better fit or check the exhalation check valve.

Donning Procedures Perform second face mask check by covering the exhalation port with your hand and exhaling. The facemask should push from your face by the pressure of your exhalation. If the mask is not pushed away, check the inhalation valve. Connect the facemask exhalation port (Red) first.

Donning Procedures Connect the inhalation side (Green) next. After the mask is donned and fully connected, open the oxygen cylinder valve fully counterclockwise and back ¼ turn. Verify chest-mounted pressure of 3000 PSIG. Note: it is normal for the gauge to take up to a minute and a half to come up to full pressure due to the flow restrictor in the gauge line.

Emergency Operation The emergency bypass valve is used manually to supply oxygen to the breathing chamber in the event of failure of the demand valve or flow restrictor. Add additional bursts as required to maintain an adequate supply of breathing gas. Remember– Oxygen is your friend. Unnecessary over-use of the Emergency Bypass will shorten your duration.

Emergency Operation Warning: the bypass valve is intended for emergencies only and WILL NOT clear facemask fogging. WASTEFUL use of the bypass valve seriously reduces the duration of the unit.

Emergency Operation Emergency actions: Equipment failure, such as blocked line. Try bypass, exit area. Severed pressure gauge. Exit area. “Over-actuation” of demand valve inside unit. Leak in system – exit area. Bad facemask seal adjust facemask fit, and tighten hoses. User warning symptoms that require immediate attention: Any feeling of nausea, dizziness or illness. Rapid pressure drop on chest mounted gauge. Any difficulty inhaling or exhaling. Smoke or other contaminants in the facemask.

Doffing the BioPak 240 Warning: most breathing apparatus malfunctions are directly traceable to careless handling after use. Many years of trouble-free operations are possible if reasonable care is given to the BioPak. Close the oxygen cylinder valve. Remove facemask by pushing forward on two lower release buckles and continue pushing forward and upward to lift the facemask over the head. Unfasten chest and waist straps and lean forward slightly at the waist. Loosen on shoulder strap, then allow the other shoulder strap to slide from the other shoulder while swinging the BioPak 240 around your front. Remove unit and set it down.

Turn-Around Maintenance Clean the mask and hose as normal using disinfectant. Place the unit on a flat surface and remove the upper housing.

Turn-Around Maintenance Slide the stainless steel lid snap latches away from the four retainer pins and remove the cover by pressing it up around the edges with your fingers and down with your thumbs on the breathing hose connections. Do not pry up on the lid with any objects. This will result in damage to the o-ring and breathing chamber. Lift the carbon dioxide absorbent canister from the BioPak 240 by pressing it up around the edges of the plastic rim with your fingers and down with your thumbs on the breathing chamber. Never attempt to open the canister while in the BioPak.

Turn-Around Maintenance Once removed from the BioPak remove the CO2 stainless steel cover by sliding the snap latch away from the retainer set pin and lifting the cover. Remove the filter pad, empty the contents of the canister into the trash. Check the o-rings on the inside and outside perimeter of the breathing chamber for abrasions or cuts. Wipe the o-ring with a clean cloth to be sure they are clean and dry, then apply a thin film of DOW 111 lubricant to them. Wipe out any particles of carbon dioxide absorbent remaining in the canister well.

Washing and Disinfecting Prepare a disinfecting solution by adding 1 packet of Portion Pak disinfectant agent per gallon of water. First clean the facemask, hoses, breathing chamber lid, and coolant canister & gel tube with disinfectant. These parts may be immersed in the disinfectant, and then rinsed several times.

Washing and Disinfecting Pour 1 about quart of disinfecting solution through the short coolant canister hose. Capping the end of the tube with your hand, move the tube up and down to thoroughly coat the inside of the tube and its corrugations with disinfectant. Allow the disinfectant to flow into the breathing chamber.

Washing and Disinfecting Repeat previous step using the exhalation hose. Take care to protect the flow restrictor assembly from getting wet. Minerals in water can deposit on the restrictor and severely limit its flow. Use a finger cot to protect the top of the flow restrictor. Rotate the unit several times to agitate the solution in the breathing chamber, thoroughly coating it.

Washing and Disinfecting Pour the solution out of the breathing chamber. Repeat this process several times using fresh water rinse. Allow the unit to air dry or connect to dryer unit. Immerse the absorbent canister, absorbent sponge, and the canister lid in the disinfectant. Wait until all other components are sanitized so that any absorbent dust left in the canister does not get onto the other parts of the BioPak. Be sure to squeeze disinfectant through the sponge filter.

Flow Test The oxygen constant flow is preset at the factory to 1.78 LPM. To check the flow: Remove the outer case cover, the breathing chamber lid, and the CO2 absorbent canister. This exposes the flow restrictor which is on the top side of the demand valve assembly. Slip the BioPak flow meter over the flow restrictor. Using two wooden tongue depressors, hold the diaphragm away from the demand valve. Open the O2 cylinder valve and measure the flow. The acceptable flow range should be at a minimum of 1.6 l p/m and a maximum of 2.2 l p/m. If the unit is not within these operating limits RED tag the unit.