Cooling Tower Maintenance Training.

Slides:



Advertisements
Similar presentations
Steering Systems Chapter 44.
Advertisements

CM 4120 Julie King Original Presentation by Todd King and I edited it.
Engine Tune-Up By Jonathan Rollins.
Boiler Operation Procedures
Training Presentation
 Without reference, identify principles relating to Fixed Radiological X-RAY PM with at least 70 percent accuracy.
3.4.5 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Pumps, Strainers and Bypass Systems Knowing how to maintain.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
Engine Maintenance Chapter 10 Emergency Repairs Afloat.
Centrifuges. Topics  Principle of Operation  Diagrams  Applications  Types of Centrifuges  History  Safety  Operation  Preventive Maintenance.
Quad Plus Shredder Drive Maintenance Joe Kowalkowski Engineering Manager – Recycling Industry
Clutch Replacement & Inspection Be sure to mark the Pressure Plate to Flywheel orientation. Loosen bolts in sequence 1/2 turn at a time to prevent warpage.
Vibration Monitoring and Machine Protection Systems 1010 E. Main St., League City, TX Phone: Fax: /
Transportation Tuesday TRANSPORTATION TUESDAY VEHICLE CARE BE AWARE !! Reliable vehicle care = Safety and Dependability.
1 Cooling Towers: Overview CM4120 Spring Topics Introduction Definitions Operating Conditions Basic Components Water Cooling Systems Types.
Maintenance At Your WWTP August 2010
Section 4: Electric Motors
"AIR COOLER" Heat Exchanger
© Goodheart-Willcox Co., Inc.  Cooling system diagnosis  Cooling system problems  Thermostat service  Cooling system hose service  Radiator and.
Vibration Sensors for Cooling Towers Challenges Cooling towers offer the vibration analyst many challenges in sensor selection, mounting and environmental.
ADB 1560 Air Disc Brake This training session will review common problems in the field and general maintenance procedures.
“Pumps” Troubleshooting Guide
Function, Construction and Operation
Introduction to FLUID COPLING.
Introduction to Hydraulics ClassAct SRS enabled. In this presentation you will: identify the fundamental parts of a hydraulic system and safety issues.
Step 1 Park vehicle on a level surface then engage the parking brake and turn off engine. If you cannot comfortably get under the car, raise the front.
Hydronic Mechanical Controls
The Airtex Educational Partnership (AEP) was started several years ago by Airtex Automotive Division as a way to merge corporate automotive expertise with.
Hydraulics For The Long Term
Vibration Monitoring & Machine Protection Systems Copyright 1999, Frank Howard, STI Vibration Monitoring, Inc. League City, Texas USA Reciprocating.
© 2012 Delmar, Cengage Learning Ignition System Service Chapter 38.
Griner Drilling Service
CHAPTER 4 CPB 20004: Plant Utility n Maintenance
COOLING TOWER Prof. Osama El Masry.
A Brief Overview Midwest COOLING TOWERS, INC. A Full Checklist of Products & Services for Your Cooling Tower Project Quality Service Integrity Value Quality.
Optimizing your handpiece life! By The Dentist’s Choice.
INTRODUCTION Definition:
Plant Utility System (TKK-2210) 14/15 Semester 4 Instructor: Rama Oktavian Office Hr.: M-F
Flat Saw Training. Flat Saw Sizes –Low Horsepower Blade diameters range from 8” (200mm) to 18” (450mm) Power ranges from 4 to 25 horsepower.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only.
© 2012 Delmar, Cengage Learning Manual Transmission Diagnosis and Repair Chapter 72.
PRE s ENT TO TRANSFER CASE WORK…….. ALL TO THE GEAR BOX……. -MAINTAINANCE….. -CHANGING OIL GEAR BOX…. -CHECKING OIL GEAR BOX……
2 nd Integrated Seminar COOLING SYSTEM2 INTRODUCTION TYPES OF COOLING SYSTEMS  ONCE THROUGH COOLING  SPRAY PONDS  SPRAY TOWERS 
Why Maintenance Tasks are Important Produced by Joe Marchese.
1-1-Why Maintenance HVAC ? Increases equipment life & reliability Reduces size & scale & number of repairs Lowers maintenance costs through better.
CHILLED WATER AIR-CONDITIONING SYSTEMS
Reconstruction, Upgrade and Repair Reconstruction, Upgrade and Repair Midwest COOLING TOWERS, INC.
1 Encotech Steam Path Audits Presentation. 2 Overview What is a Steam Path Audit? Benefits Cost Chronology of a Steam Path Audit STPE Results.
OILGEAR PVV PUMPS PVV 200 Performance Curves.
Automotive Engines: Theory and Servicing, 7/e By James D. Halderman Copyright © 2011, 2009, 2005, 2001, 1997 Pearson Education, Inc., Upper Saddle River,
TROUBLESHOOTING ELECTRIC MOTORS
Engine Cooling Systems
Temperature Test Allows monitoring of temperature changes.
Mould Maintenance Presented By S.K Mandal.
Clinical engineering Lecture (7).
Internal Training Module
S.T.B.S College of Diploma Engineering, SURAT
CV maintenance works during YETS
Fans & Heaters technical seminar
Tribology at Vattenfall R&D
Ignition Systems Overview
COOLING TOWER.
Student CD for Commercial Refrigeration for A/C Technicians Chapter 12 Ice Machines.
Troubleshooting 11/14/2018 Water King Service Seminar.
TROUBLESHOOTING ELECTRIC MOTORS
Timeline of Key Events B&W Safety Assessment Indicates Head Inspection Being Performed, Sources of Leaks Identified, No Other Inspections Required D-B.
Rajan Bhandari Senior Lecturer
Correct Procedures for Changing, Storing, and Maintaining Saw Blades
Diagnosing Engine Problems
Fluid Power System Maintenance and Troubleshooting
Presentation transcript:

Cooling Tower Maintenance Training

Training Overview Safety First What is a Cooling Tower Cooling Towers Components Structure Inspection / Maintenance Summary Questions / Discussion

Safety First Identify potential hazards Plan ahead Follow safety and health regulations Use personal protective equipment

What Is a Cooling Tower? A cooling tower is a piece of equipment that derives a primary cooling effect from the evaporation of water when brought into direct contact with air. Cooling towers are designed to expose the maximum transient water surface to the maximum air flow.

Types of Cooling Towers Crossflow towers Counterflow towers

Crossflow Cooling Towers Crossflow cooling towers use splash fill media through which the incoming cool air flows horizontally ACROSS the downward flow of hot water from the top distribution basins. These types of towers were predominantly used from the 1950’s through the 1970’s.

Crossflow Cooling Tower

Typical Crossflow Towers

Counterflow Cooling Towers In counterflow cooling towers the incoming cool air moves vertically up through the fill media, COUNTER to the downward flow of hot water coming from the distribution laterals. These types of towers are commonly used in today’s applications.

Counterflow Cooling Tower

Typical Counterflow Towers

Other Types of Cooling Towers

Cooling Tower Components

Cooling Tower Components Counterflow

Cooling Tower Components Crossflow

Fan Stacks Check for cracks Check & tighten any loose hardware Check & clean weep holes

Air Inlet Louvers Reduce splash out & water loss Check for broken arms or rods after winter operation

Distribution System Maintenance interval: Annually Check lateral to header joints for bushing leakage

Distribution Nozzles Maintenance interval: Annual full inspection Monthly ground level visuals Uneven flow Plugged nozzles Repair: clean out

Fill Media Maintenance interval: Annual Inspect for plugging or biological fouling Check for damage to top surface Check bottom of fill for sagging caused by exceeding temperature limitation

Plugged Film Fill

Drift Eliminators Maintenance interval: annual inspection Look for damaged or plugged sections Look for gaps that permit water bypass Repair: replace damaged sections

Mechanical System

Motors Maintenance interval: semi-annual Grease inboard & outboard bearings Motor may have zerk and grease relief vent, or may have plugs

Motors Keep drive shaft installed during operation

Motor Lubricant Use a poly urea base grease with a good grade of petroleum oil, No. 2 consistency If grease vent plug is NOT removed, grease enter motor windings, causing premature motor failure

Drive Shaft & Coupling Maintenance interval: Annual or after high torque event Check alignment Inspect for corrosion, soft spots or cuts in shaft Check flex coupling for protrusions or bumps on surface

Gear Boxes Maintenance interval: change oil after first 500 hours or 4 weeks, then every 2,500 hours or 6 months During shutdown periods: cool down gear box for 4 hours, then run 5 minutes/week until startup Check oil weekly

Gear Box Tips Two-speed motors: switching from High Speed to Low Speed requires coast-down to below Low Speed rpm before activating motor at Low Speed Can be done manually Recommend timer in circuit to permit fan to coast for specified time before Low Speed is activated

Gear Box Tips Variable speed drive operation: Do not operate a standard gear box below 450 rpm due to lubrication problems Inspect case for excessive deposits which may cause overheating

Gear Box Tips Extended Shutdown Fill gear box case with oil to top of case through oil breather port and cover with tarp Before restart: Don’t forget to return oil to correct level prior to operation

Gear Box Vent Lines Maintenance interval: weekly checks Look for blockage in line Repair: clean out Blockage causes pressure build up in case

Fan Assembly Maintenance interval: by opportunity Check fan tip clearance Visually check leading edges for wear Inspect surface for scale build-up Check hub end of blades for cracks Clean weep holes

Fan Hub Maintenance interval: annual Inspect connections between hub and blades Check for loose connection between hub and cover

Vibration Switches Maintenance interval: As required for trip delay set point Brochures available from Midwest Towers

Cooling Tower Structure

What Can Go Wrong?

Deteriorated Structure

Over Tightened Hardware

Structural Failure

Delaminated Fan Deck

Structural Inspection Tips Check for signs of biological or chemical attack annually Check for cracks or deterioration annually Check & tighten any loose hardware annually Replace any damaged structure immediately

Recommended Spare Parts (1) Gearbox (1) Drive Shaft (10) Nozzles (10) Louver Arms (If applicable)

Inspection/Maintenance Summary Weekly Check gear box oil level & drive vent tube Monthly Check nozzles for uneven flow or plugging Semi-Annually Replace motor bearing grease

Inspection/Maintenance Summary Annually Inspect structure for cracks & deterioration Check, clean & if necessary replace distribution nozzles Check & clean fan blades & weep holes Check fill for damage, plugging or biological growth

Inspection/Maintenance Summary Annually Check drift eliminators for damaged sections or gaps Inspect fan stacks for loose hardware Check drive shaft & coupling (also after high torque event) Check fan blades for wear, cracks, scale & tip clearance (also at any opportunity)

Inspection/Maintenance Summary Change gear box lubricant after first 500 hours or 4 weeks, then every 2,500 hours or 6 months of continuous operation

Questions If you are unsure about what to check or have any questions or concerns, please feel free to contact your Midwest Towers representative to schedule a cooling tower inspection.

Midwest COOLING TOWERS, INC Corporate Office: Chickasha, OK Tel 405.224.4622 Fax 405.224.4625 www.mwcooling.com sales@mwcooling.com